HomeMy WebLinkAboutM501 - MECHANICAL DETAILSFINISHED INTERIOR MIN. 32" SQUARE DOOR MIN. 30" WATER HEATER PAN WATER HEATER MECHANICAL EQUIPMENT PLENUM CLEARANCE CPVC CONDENSATE DRAIN W/ TRAP; ROUTE TO HUB DRAIN WITH AIR GAP MAIN SHUT-OFF WATER HEATER PAN SLEEVE FLEX CONN. FIRE DAMPER SIMILAR TO RUSKIN CFD7 FAN COIL WATER HEATER HW CW VALVE SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN FOR UNITS, REFER TO MECHANICAL AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER (TYP.) MIN. 20" REFRIGERANT SUCTION / LIQUID; ROUTE TO CONDENSING UNIT METAL SHELF RETURN AIR GRILLE, SEE PLANS SECURE AIR HANDLER TO WALL WITH Z PANEL CLIPS / HANGERS AND ANGLE BRACKETS 10"X10" ACCESS PANEL NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON MECHANICAL DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOISTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING AND FLOOR. 6. WOOD SHELF/DRYWALL DIVIDER CAN BE OMITEED IF ALL MATERIALS CONTAINED WITHIN MECHANICAL CLOSET HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. FINISHED INTERIOR MIN. 32" SQUARE DOOR MIN. 30"MECHANICAL EQUIPMENT PLENUM CLEARANCE CPVC CONDENSATE DRAIN; ROUTE TO HUB DRAIN FLEX CONN. DUCT FIRE DAMPER W/ACCESS PANEL FAN COIL SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN FOR UNITS, REFER TO MECHANICAL AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER (TYP.) MIN. 20" NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON MECHANICAL DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOISTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING AND FLOOR AND THROUGH AHU SUPPORT. 6. ALL MATERIALS CONTAINED WITHIN MECHANICAL CLOSET HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. REFRIGERANT SUCTION / LIQUID; ROUTE TO CONDENSING UNIT RETURN GRILLE, SEE PLANS 10" X 10" ACCESS PANEL R.A. DUCT WALL MOUNT EQUIPMENT OUTSIDE AIR CONNECTIONRSRLEVAPORATOR COIL THERMAL EXPANSION VALVE SIGHTGLASS REFER TO AIR COOLED CONDENSING UNIT SCHEDULE FOR REFRIGERANT LINE SIZES AIR COOLED CONDENSING UNIT WITH FACTORY INSTALLED: 1. LIQUID LINE FILTER DRIER 2. SUCTION AND DISCHARGE LINE REFRIGERATION CHARGING CONNECTIONS FIELD BRAZED CONNECTIONS ISOLATION VALVE, TYP. WALL WALL PULL OUT DOOR DRYER BOX FLOOR 4"Ø ALUMINUM OR FOIL FLEX DUCT TO DRYER 4"Ø RIGID DUCT SECONDARY LENT TRAP IN VERTICAL DUCT RISER CAULK AROUND DUCT PENETRATION. RIGID DUCT UP WALL WALL EXHAUST FAN, SEE PLANS WALL CAULK/SEAL LINESET (1 PER SLEEVE) 3" MIN. FIRECAULK (INSIDE AND OUTSIDE SLEEVE) 3" METAL SLEEVE 20 GA MIN. TAPE CUT ENDS (TO PREVENT SHARP EDGES) FLOOR ASSEMBLY SUBFLOOR WOOD TRUSS CEILING ASSEMBLYFIRECAULK (INSIDE AND OUTSIDE PIPE) 8" MIN.2"2"GENERAL NOTES: 1. DO NOT INSTALL IN CORNERS 2. SLEEVES AT TOP FLOOR CEILING ROD 3. SLEEVES TO BE FASTENED IN PLACE BEFORE DRYWALL / LINESET INSTALL 4. MIN 8" FROM SIDEWALL AND 4" FROM BACK WALL. 16GA. GALV. DISCHARGE PLENUM STORM COLLAR SECURED & CAULKED TO DUCT CURB BY G.C. CURB CAP-SECURE TO DUCT & CAULK WATER TIGHT SEE PLAN FOR DUCT CONT. COVER OPENING WITH 1/2"x1/2" MESH HARDWARE HOLE THRU ROOF TO BE 1" LARGER THAN DUCT (BOTH WAYS)36"(PRIMARY) CONDENSATE DRAIN WITH VENTED P-TRAP. TYPICAL ALL UNITS. PROVIDE VENT @ TOP OF CONDENSATE 3/4" 3/4" FIFTH FLOOR CEILING FCU CEILING FLOOR PENETRATIONS TO BE FIRE RATED TYPICAL ALL UNITS. 3/4" 3/4" FOURTH FLOOR FCU CEILING 3/4" 3/4" THIRD FLOOR FCU CEILING 3/4" 3/4" SECOND FLOOR FCU CEILING NOTE: CONDENSATE PIPING IN PLENUM TO BE COPPER. ALL WIRING AND PIPING TO BE PLENUM RATED. INSTALL BOT. OF UNIT NOM. 7" ABOVE CEILING, SAME AT ALL LOCATIONS EXH. VENT TERMINATION, SEE PLANS CAULK/SEAL WALL FLANGE & WATER -TIGHT SEAL REFER TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET M501MECHANICAL DETAILS NORTH ENDAPARTMENTSCARMEL, IN12" = 1'-0" MECHANICAL ROOM DETAIL 1 12" = 1'-0" MECHANICAL ROOM DETAIL (CORRIDOR)2 12" = 1'-0" REFRIGERATION PIPING DETAIL3 12" = 1'-0" VERTICAL DRYER EXHAUST DUCT DETAIL4 12" = 1'-0" WALL MOUNTED BATH EXHAUST FAN DETAIL5 12" = 1'-0" LINESET SLEEVE DETAIL 6 12" = 1'-0" LINESET HOOD DETAIL TO SIDE WALL7 12" = 1'-0" GOOSENECK DETAIL8 12" = 1'-0" CONDENSING UNIT DETAIL 10 12" = 1'-0" AIR HANDLING UNIT RISER DIAGRAM9 12" = 1'-0" VENT TERMINAL DETAIL11 6" = 1'-0" PENTHOUSE ELEVATOR VENT12 # DESCRIPTION DATE 07/08/21