HomeMy WebLinkAboutP000 - SYMBOLS AND ABBREVIATIONSSTORM DRAIN
CONDENSATE DRAIN
SANITARY WASTE (W)
SANITARY GREASE
SANITARY FORCED MAIN
SANITARY VENT (V)
ACID WASTE
ACID VENT
DRAIN
INDIRECT WASTE
PUMP DISCHARGE
DOMESTIC COLD WATER (CW)
DOMESTIC HOT WATER SUPPLY (HW)
DOMESTIC HOT WATER RETURN (HWR)
140°F HOT WATER
140°F HOT WATER RETURN
NON-POTABLE WATER
CONDITIONED SOFT WATER
CHLORINATED WATER
DISTILLED WATER
DEIONIZED WATER
FIRE SUPPRESSION
NATURAL GAS (WC OR PSIG)
GAS VENT
LIQUID PETROLEUM
MEDICAL COMPRESSED AIR (WC OR PSIG)
MEDICAL VACUUM
OXYGEN
NITROGEN
NITROUS OXIDE
CARBON DIOXIDE
WET VACUUM CLEANING
DRY VACUUM CLEANING
COMPRESSED AIR (WC OR PSIG)
TEMPERED WATER SUPPLY
SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA
FOR ADDITIONAL INFORMATION.
KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR
ADDITIONAL INFORMATION.
DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL
INFORMATION.
DRAWING BLOCK TITLE
INDICATOR:
REFERENCE DRAWING MODULE LOCATION FOR
ADDITIONAL INFORMATION.
MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL
INFORMATION.
REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR
ADDITIONAL INFORMATION.
EQUIPMENT INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL
INFORMATION.
TU-XL.##
ø DIAMETER, PHASE
°F DEGREES FAHRENHEIT
EEW EMERGENCY EYEWASH
A COPRESSED AIR
EWC ELECTRIC WATER COOLER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OSD OPEN SITE DRAIN
AD AREA DRAIN, ACCESS DOOR
EX EXISTING
OZ OUNCE
AFF ABOVE FINISHED FLOOR
P PUMP
AGA AMERICAN GAS ASSOCIATION
FCO FLOOR CLEANOUT
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
FD FLOOR DRAIN, FIRE DAMPER
PE POLYETHYLENE
FDC FIRE DEPARTMENT CONNECTION
PH PHASE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
PIV POST INDICATOR VALVE
FH FUME HOOD
PPM PARTS PER MILLION
AP ACID PROOF, ACCESS PANEL
FHC FIRE HOSE CABINET
PRV PRESSURE REDUCING VALVE
APPROX. APPROXIMATELY
FLR FLOOR
PSI POUNDS PER SQUARE INCH
ARCH ARCHITECT
FM FACTORY MUTUAL
PSIG POUNDS PER SQUARE INCH GAUGE
FPM FEET PER MINUTE
PVC POLYVINYL CHLORIDE
FSC FIRE SUPPRESSION CONTRACTOR
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
FT FOOT, FEET
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
FTG FOOTING
RCP REINFORCED CONCRETE PIPE
AUTO AUTOMATIC
G NATURAL GAS
RD ROOF DRAIN
AVG AVERAGE
GA GAGE OR GAUGE
AVS ACID VENT STACK
GAL GALLON
AW ACID WASTE
GC GENERAL CONTRACTOR
AWWA AMERICAN WATER WORKS ASSOCIATION
GPD GALLONS PER DAY
RM ROOM
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
RPM REVOLUTIONS PER MINUTE
BF BARRIER FREE
BFC BELOW FINISHED CEILING
BHP BRAKE HORSEPOWER
GT GREASE TRAP
BLDG BUILDING
HB HOSE BIBB
HD HEAD (FT.)
SAN SANITARY
BOP BOTTOM OF PIPING
Hg MERCURY
BSMT BASEMENT
BT BATHTUB
HO HUB OUTLET
SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR
BTM BOTTOM
BtuH BRITISH THERMAL UNIT PER HOUR
HP HORSEPOWER, HEAT PUMP
CA COMPRESSED AIR
HR HOUR(S)
SK SINK
CB CATCH BASIN
HYD WALL HYDRANT
Hz HERTZ
CD CONDENSATE DRAIN
SPEC SPECIFICATION
CO CARBON DIOXIDE
ID INSIDE DIAMETER
IE INVERT ELEVATION
CFM CUBIC FEET PER MINUTE
IN INCH, INCHES
INT INTERIOR
SS SERVICE SINK, STAINLESS STEEL
INV INVERT
STD STANDARD
CI CAST IRON
IPS INTERNATIONAL PIPE STANDARD
CMP CORRUGATED METAL PIPE
IW INDIRECT WASTE
CO CLEANOUT
KEC KITCHEN EQUIPMENT CONTRACTOR
kW KILOWATT
LAB LABORATORY
TEMP TEMPERATURE
CP CICRULATOR PUMP
CPVC CHLORINATED POLYVINYL CHLORIDE
L LAVATORY
LBS POUNDS
TMV THERMOSTATIC MIXING VALVE
LF LINEAR FEET
LP LIQUID PETROLEUM
TP TRAP PRIMER
TS TAMPER SWITCH
CW COLD WATER
CWP CONDENSER WATER PUMP
MAX MAXIMUM
TYP TYPICAL
DBP DOMESTIC BOOSTER PUMP
MB MOP BASIN
DCVA DOUBLE CHECK VALVE ASSEMBLY
MBH THOUSAND Btu PER HOUR
MC MECHANICAL CONTRACTOR
UL UNDERWRITERS LABORATORIES
DH DRENCH HOSE
MCA MINIMUM CIRCUIT AMPS
UON UNLESS OTHERWISE NOTED
UR URINAL
DIA DIAMETER
MFR MANUFACTURER
DN DOWN
MH MANHOLE
V VOLTS, VENT
MIN MINIMUM
VAC VACUUM
DS DOWNSPOUT
MISC MISCELLANEOUS
DW DISTILLED WATER
VB VACUUM BREAKER
DWG DRAWING
DWV DRAIN, WASTE & VENT
N NITROGEN
NA NOT APPLICABLE
EA EACH
NC NORMALLY CLOSED
VFD VARIABLE FREQUENCY DRIVE
NEC NATIONAL ELECTRIC CODE
VTR VENT THROUGH ROOF
EC ELECTRICAL CONTRACTOR
NFC NATIONAL FIRE CODE
ECO EXTERIOR CLEANOUT
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
W WASTE, WATT
WC WATER COLUMN, WATER CLOSET
NIC NOT IN CONTRACT
NO NORMALLY OPEN, NITROUS OXIDE
EFF EFFICIENCY
NOM NOMINAL
WCO WALL CLEANOUT
NP NON-POTABLE WATER
EL ELEVATION
NTS NOT TO SCALE
O OXYGEN
ES EMERGENCY SHOWER
YD YARD DRAIN
FLOW DIRECTION ARROW, PITCH DIRECTION ARROW
PIPE RISE
PIPE DROP
PIPE CAP
PIPE CONTINUES (REFERENCE ELSEWHERE)
PIPE GUIDE
PIPE ANCHOR
EXPANSION LOOP
UNION, FLANGED UNION
GATE VALVE
BALL VALVE
GLOBE VALVE
BUTTERFLY VALVE
PLUG VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
REDUCED PRESSURE BACKFLOW PREVENTER
DOUBLE CHECK BACKFLOW PREVENTER
DOUBLE DETECTOR CHECK VALVE ASSEMBLY
ANGLE VALVE
RELIEF VALVE
VALVE WITH OUTSIDE STEM & YOKE
SOLENOID VALVE
FLOW SWITCH
PRESSURE SWITCH
AQUASTAT
BALANCE VALVE
STRAINER
STRAINER WITH CAPPED BLOWDOWN
MANUAL AIR VENT
AUTOMATIC AIR VENT
VACUUM BREAKER
TEMPERATURE/PRESSURE TAP
THERMOMETER
PRESSURE GAUGE
AIR FILTER/DRYER
INLINE PUMP
WATER HAMMER ARRESTER WITH SCHEDULE TYPE
P-TRAP AND RISER
FLOOR DRAIN WITH SIZE & SCHEDULE TYPE
END OF PIPE CLEANOUT
FLOOR CLEANOUT
WALL CLEANOUT
EXTERIOR CLEANOUT OR RODDING HOLE
HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE
WATER METER
GAS METER
ROOF DRAIN, OVERFLOW DRAIN WITH SIZE
POST INDICATOR VALVE
FIRE DEPARTMENT CONNECTION
VALVE TAMPER SWITCH
UPRIGHT SPRINKLER HEAD
PENDANT SPRINKLER HEAD
DRY PENDANT SPRINKLER HEAD
CONCEALED SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS TO REMAIN.
INTERMEDIATE DASHED LINETYPE INDICATE EXISTING ITEMS TO BE
REMOVED.
INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE NEW
ITEMS.
THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE.
INDICATES POINT OF NEW CONNECTION TO EXISTING EQUIPMENT, PIPING
OR MATERIALS.
INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING
OR MATERIALS.
PIPING LINE SYMBOLS
REFERENCE SYMBOLS
ABBREVIATIONS AND TERMS PIPING IDENTITY SYMBOLS
LINETYPE DESIGNATORS
DRAWING BLOCK TITLE
SECTION LOCATION
IN DRAWING MODULE
SECTION LOCATION AT SUBSET SHEET
DETAIL LOCATION IN
DRAWING MODULE
DETAIL LOCATION AT
SUBSET SHEET
LARGE SCALE VIEW LOCATION IN
DRAWING MODULE
LARGE SCALE VIEW
LOCATION AT SUBSET SHEET
KEYNOTE INDICATORS
EQUIPMENT TYPE
NUMERIC CHARACTER RELATES TO ITEM
ALPHANUMERIC CHARACTER RELATES
TO ASSOCIATED AIR HANDLER (OPTIONAL)
AREA LEADER
LINE LEADER
POINT LEADER
DRAWING MODULE LOCATION
(IDENTIFYING LOWER LEFT OF MULTIPLE MODULES)
REVISION CLOUD
REVISION INDICATOR
NUMERIC SCALE
SEE P-102
REFER TO ADDITIONAL
SHEET FOR CONTINUATION
FLOOR PLAN OVERLAP
BEYOND AREA
EXTENSION
PLAN
PLAN
NUMERIC CHARACTER
RELATES TO ITEM
NORTH ARROW
BEYOND AREA
EXTENSION
ALPHANUMERIC CHARACTER RELATES TO
BUILDING LEVEL (OPTIONAL)
SCALE: 1/8" = 1'-0"
M
G
CO
4"RD 4"OFD
DVC
WVC
N0
N
0
MV
MA
GV
LP
G
F
DE
DI
CL
CSW
140°F
140°F
PD
D
AV
AW
CD
ST
FM
SG
IW
A
TW
CO
NPW
FD
HB-1 WH-1
FCO
2"FD-1
WCO
WHA-A
M
S
P
T
F
TS
X
XX X X
X
X
X
X
X X
2
N
WB WASHER BOX
ECO
DF DRINKING FOUNTAIN
HW HOT WATER
HWR HOT WATER RETURN
GW GREASE WASTE
HX HEAT EXCHANGER
OW OIL WASTE
PP POLYPROPYLENE
PW PURE WATER
RPBP REQUIRED PRESSURE BACKFLOW PREVENTER
SG SPECAIL GAS
SH SHOWER
TD TRENCH DRAIN
T TURRET
TDH TOTAL DYNAMIC HEAD
TET THERMAL EXPANSION TANK
GENERAL NOTES
WSB WATER SUPPLY BOX
A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS
OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL
CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE
CONTRACT DOCUMENTS AS IF REPEATED HEREIN.
B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND
DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING
APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON
BOTH.
C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED
TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE
PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES
PRIOR TO SUBMITTING A BID PROPOSAL.
D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS
POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND
IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL
FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE
AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR.
E. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE
ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT
DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF
ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE
ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT
WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE
DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS
ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK.
ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS
SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO
ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER.
F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO
SCALE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS
AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF
DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED
FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT
DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE.
G. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN.
WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE
DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH THE WORK.
H. ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE
CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND
ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS.
I. ALL CONFLICTS, WHICH MAY PREVENT THE COMPLETION OF WORK AS
INTENDED, SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. THE
CONTRACTOR SHALL NOT PROCEED WITH ANY RELATED WORK UNTIL ALL
CONFLICTS ARE RESOLVED AND THE CLARIFYING INFORMATION IS ISSUED TO
THE CONTRACTOR BY THE ARCHITECT.
J. PROVIDE NFPA APPROVED FIRE STOPPING WHERE PIPES PENETRATE FIRE
RATED FLOORS AND WALLS.
K. FIELD VERIFICATION: CONTRACTOR SHALL INSPECT AND VERIFY ALL
EXISTING FIELD CONDITIONS, CLEARANCES AND DIMENSIONS BEFORE
STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES
ACCEPTANCE OF EXISTING CONDITIONS. SHOULD DIFFERENT CONDITIONS
BE ENCOUNTERED, CONTACT ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH ANY WORK.
GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES
WITHIN THE DRAWING SET.
GENERAL
PLUMBING NOTES:
NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN
THE DISCIPLINE.
GENERAL SHEET
NOTES:
NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET
ON WHICH THEY APPEAR.
SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET
ON WHICH THEY APPEAR AND USE A KEYNOTE
INDICATOR TO IDENTIFY ITEMS.
NOTATION DESIGNATORS
DEMOLITION NOTES
A. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES PRIOR
TO INSTALLATION.
B. CONTRACTOR SHALL COORDINATE SHUT DOWN OF ANY PLUMBING SYSTEM
WITH THE OWNER AND ANY AUTHORITY HAVING JURISDICTION.
C. CONTRACTOR SHALL PROVIDE TEMPORARY CAPS FOR ALL SERVICES AS
REQUIRED SO EXISTING SYSTEMS WILL REMAIN OPERATIONAL.
D. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING
CONSTRUCTION. ANY FACILITIES DAMAGED OR DISCONNECTED BY
CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS
OPERATING AND APPEARANCE CONDITION.
E. CONTRACTOR SHALL REPAIR OR REPLACE PIPE INSULATION DAMAGED
DURING DEMOLITION OR RENOVATION WORK TO MATCH ORIGINAL
CONDITION.
F. CONTRACTOR SHALL COORDINATE WITH APPROPRIATE TRADE TO CUT AND
PATCH FINISHED AREAS AS REQUIRED, UNLESS OTHERWISE NOTED ON
DOCUMENTS.
G. CONTRACTOR SHALL REMOVE AND REPLACE CEILINGS, LIGHT FIXTURES,
ETC. IN EXISTING BUILDING AS REQUIRED TO PERFORM DEMOLITION AND
RENOVATION WORK. AFTER WORK IS COMPLETE, DAMAGED ITEMS SHALL BE
REPAIRED TO ORIGINAL CONDITION OR REPLACED.
H. CONTRACTOR SHALL REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS
A RESULT OF NEW CONSTRUCTION AND/OR RENOVATION.
I. CONTRACTOR SHALL THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY
DEMOLITION WORK. ANY DEVICES REMOVED ACCIDENTALLY WILL BE
REPLACED AT NO ADDITIONAL COST TO OWNER.
J. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL,
STATE AND FEDERAL REGULATIONS.
FIRE PROTECTION NOTES
A. ALL FIRE PROTECTION WORK ON THE DRAWINGS IS NEW AND BY THIS
CONTRACTOR UNLESS OTHERWISE INDICATED.
B. THE FIRE PROTECTION CONTRACTOR SHALL FURNISH ALL REQUIRED LABOR
AND PROVIDE ALL MATERIAL, EQUIPMENT INCLUDING ALL CONTRACTOR'S
SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF THE REQUIRED
SYSTEMS IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES.
THE FINISHED INSTALLATION SHALL BE FUNCTIONAL AND COMPLETE IN
EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR COMPLETE AND
OPERATIONAL SYSTEMS.
C. FIRE PROTECTION SYSTEM FOR BUILDING SHALL BE DESIGNED FOR LIGHT
HAZARD, 0.10 GPM PER SQUARE FOOT OVER 1,500 SQUARE FEET.
MECHANICAL, STORAGE AND LAB AREAS SHALL BE DESIGNED FOR ORDINARY
HAZARD, 0.15 GPM PER SQUARE FOOT OVER 1,500 SQUARE FEET.
D. SPRINKLER SYSTEM SHALL BE HYDRAULLICALLY CALCULATED, FULLY
SUPERVISED AND INSTALLED ACCORDING TO NFPA 13.
E. THE FIRE PROTECTION CONTRACTOR SHALL OBTAIN FLOW TEST DATA BY
MEANS OF A FLOW TEST PRIOR TO DESIGN HYDRAULIC CALCULATION OF
SPRINKLER SYSTEM.
F. CUTTING AND PATCHING, AND CORE DRILLING FOR FIRE PROTECTION WORK
SHALL BE THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR.
G. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL
COORDINATION, LAYOUT, CODE COMPLIANCE AND DESIGN.
H. PROVIDE UPRIGHT HEADS IN UNFINISHED SPACES (I.E.: THOSE WITH
EXPOSED STRUCTURE), RECESSED PENDENT HEADS IN FINISHED SPACES
(I.E.: THOSE WITH LAY-IN OR HARD CEILINGS), SIDEWALL HEADS WHERE
IMPRACTICAL TO INSTALL PENDENT OR UPRIGHT TYPE, OR AS INDICATED
OTHERWISE ON THE DRAWINGS.
I. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
OF CEILING MOUNTED ITEMS.
J. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDING
WALK-THRU'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE END OF THE
1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL AND IS
RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEM REQUIRED
AS A RESULT OF THIS BUILDING INSPECTION.
K. SEISMIC RESTRAINTS: IF THE SEISMIC DESIGN CATEGORY FOR THE BUILDING
IS "C" OR WORSE, THEN THE FIRE PROTECTION SPRINKLER SYSTEM AND
SUPPORTS SHALL BE DESIGNED AND INSTALLED FOR THE SEISMIC FORCES
IN ACCORDANCE WITH THE BUILDING CODE.
L. ELEVATOR EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS THROUGH
ELEVATOR EQUIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR
EQUIPMENT ROOMS, DO NOT ROUTE OVER ELEVATOR EQUIPMENT OR
ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS.
M. ELECTRICAL EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS OVER
ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER
SERVICE ACCESS.
N. DO NOT ROUTE ANY SYSTEMS ABOVE ELECTRICAL EQUIPMENT OR
ELECTRICAL COMPONENTS.
PLUMBING NOTES
A. ALL WORK ON THE PLUMBING DRAWINGS IS NEW AND BY THIS CONTRACTOR
UNLESS OTHERWISE INDICATED.
B. THE PLUMBING CONTRACTOR SHALL INCLUDE IN HIS BID ALLOWANCES, FEES,
AND COSTS TO COMPLETE THIS PROJECT.
C. THE PLUMBING CONTRACTOR SHALL FURNISH ALL REQUIRED LABOR AND
PROVIDE ALL MATERIAL, EQUIPMENT INCLUDING ALL CONTRACTOR'S
SERVICES NECESSARY TO COMPLETE INSTALLATION OF THE REQUIRED
SYSTEMS IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES.
THE FINISHED INSTALLATION SHALL BE FUNCTIONAL AND COMPLETE IN
EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR COMPLETE AND
OPERATIONAL SYSTEMS.
D. ALL PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF
THE INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH
THE LATEST INDIANA AMENDMENTS).
E. ALL SOIL, WASTE, VENT, AND STORM PIPING SHALL BE INSTALLED AT THE
FOLLOWING MINIMUM SLOPE:1/8" (1%) PER FOOT GRADE FOR PIPE SIZES 3"
AND LARGER. 1/4" (2%) PER FOOT GRADE FOR PIPE SIZES 21/2" AND SMALLER.
F. CUTTING AND PATCHING, AND CORE DRILLING FOR PLUMBING WORK SHALL
BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR.
G. PIPING AND/OR EQUIPMENT SHALL NOT BE SUPPORTED FROM STRUCTURAL
MEMBERS WITHOUT PRIOR REVIEW AND APPROVAL FROM THE STRUCTURAL
ENGINEER.
H. ALL DOMESTIC WATER PIPING SHALL BE INSULATED. REFER TO INSULATION
SCHEDULE IN SPECIFICATIONS.
I. ALL PLUMBING FIXTURES AND EQUIPMENT SHALL CONFORM TO ALL
APPLICABLE ENERGY CONSERVATION CODES.
J. ALL PIPING, VALVES, AND ACCESSORIES SERVING EQUIPMENT SHALL
CONFORM TO ALL APPLICABLE ENERGY CONSERVATION CODES.
K. ANCILLARY SYSTEMS NOT ASSOCIATED WITH EQUIPMENT SHALL NOT BE
INSTALLED SO AS TO INHIBIT SERVICING AND/OR REMOVAL OF SAID
EQUIPMENT.
L. STERILIZE DOMESTIC WATER PIPING SYSTEM IN ACCORDANCE WITH STATE
AND LOCAL CODES, AND BASE BUILDING SPECIFICATIONS.
M. PRIOR TO THE INSTALLATION, FABRICATION, REMOVAL, OR RELOCATION OF
ANY WORK, THE CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE
ACTUAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND
SHALL FULLY COORDINATE ALL WORK WITH THE ARCHITECTURAL PLANS,
BUILDING STRUCTURE, AND WORK OF ALL OTHER TRADES. CONTRACTOR
SHALL VERIFY EXISTING INVERTS PRIOR TO CONSTRUCTION.
N. FOUNDATION AND FOOTINGS SHALL NOT BE DISTURBED WITHOUT OBTAINING
PERMISSION FROM THE ARCHITECT AND/OR STRUCTURAL ENGINEER.
PROPER UNDERPINNING METHODS SHALL BE USED TO PROTECT AFFECTED
FOUNDATION COMPONENTS.
O. PROVIDE PIPE ESCUTCHEONS AT EXPOSED PIPE PENETRATIONS AT ALL
FINISHED WALLS AND CEILINGS.
P. PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHT WALLS.
Q. PROVIDE A CHECK VALVE ON HOT AND COLD WATER BRANCH LINES SERVING
ALL MOP SINKS.
R. PROVIDE WATER HAMMER ARRESTERS PRIOR TO QUICK-CLOSING VALVES (ie:
ELECTRIC, PNEUMATIC, SPRING LOADED VALVES OR DEVICES, QUICK HAND
CLOSURE VALVES OR FIXTURE TRIM). SIZE ARRESTERS PER SCHEDULE ON
DRAWINGS AND PDI-WH 201 CERTIFIED STANDARD.
S. INSULATE ALL PLASTIC PIPING IN RETURN AIR PLENUMS TO MAINTAIN 25/50
FIRE SMOKE RATING AND AS DIRECTED IN SPECIFICATIONS. INSULATION
MATERIAL SHALL BE 1/2" CLOSED CELL ELASTOMERIC, UNLESS OTHERWISE
INDICATED IN PART 3 OF SPECIFICATION SECTION 220700.
T. COORDINATE VENT PENETRATIONS WITH MECHANICAL ROOF TOP
EQUIPMENT, REFER TO "H" SERIES DRAWINGS. OFFSET VENTS AS REQUIRED
TO MAINTAIN MINIMUM 10'-0" SEPARATION FROM AIR INTAKES.
U. PROVIDE "LEAD-FREE", "NO-LEAD", AND/OR "LOW -LEAD" PLUMBING FITTINGS
COMPLIANT WITH THE FEDERAL LAW IN EFFECT ON JANUARY 4, 2014 -
MAXIMUM 0.25% LEAD CONTENT.
V. PROVIDE FREEZE PROTECTION FOR ALL DOMESTIC WATER PIPING AND
TRAPS INSTALLED IN UNHEATED AREAS. USE ELECTRIC HEAT TRACE CABLE
AND INCLUDE ALL ACCESSORIES FOR A COMPLETE AUTOMATIC OPERATING
FREEZE PROTECTION SYSTEM. COVER WITH INSULATION. ALL HEAT
TRACING COMPONENTS SHALL BE PROVIDED AND INSTALLED BY THE
PLUMBING CONTRACTOR. FINAL CONNECTION TO THE ELECTRICAL SYSTEM
SHALL BE MADE BY THE ELECTRICAL CONTRACTOR.
W. ELEVATOR EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS THROUGH
ELEVATOR EQUIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR
EQUIPMENT ROOMS, DO NOT ROUTE OVER ELEVATOR EQUIPMENT OR
ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS.
X. TELECOMMUNICATIONS ROOMS:(MDF AND IDF) DO NOT ROUTE ANY
SYSTEMS OVER EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER
SERVICE ACCESS.
Y. ELECTRICAL EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS OVER
ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER
SERVICE ACCESS.
Z. DO NOT ROUTE ANY SYSTEMS ABOVE ELECTRICAL EQUIPMENT OR
ELECTRICAL COMPONENTS.
W
V
RADON R
NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID SET
P000SYMBOLS ANDABBREVIATIONSNORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE
07/08/21