HomeMy WebLinkAboutP000 - SYMBOLS AND ABBREVIATIONSSTORM DRAIN CONDENSATE DRAIN SANITARY WASTE (W) SANITARY GREASE SANITARY FORCED MAIN SANITARY VENT (V) ACID WASTE ACID VENT DRAIN INDIRECT WASTE PUMP DISCHARGE DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER SUPPLY (HW) DOMESTIC HOT WATER RETURN (HWR) 140°F HOT WATER 140°F HOT WATER RETURN NON-POTABLE WATER CONDITIONED SOFT WATER CHLORINATED WATER DISTILLED WATER DEIONIZED WATER FIRE SUPPRESSION NATURAL GAS (WC OR PSIG) GAS VENT LIQUID PETROLEUM MEDICAL COMPRESSED AIR (WC OR PSIG) MEDICAL VACUUM OXYGEN NITROGEN NITROUS OXIDE CARBON DIOXIDE WET VACUUM CLEANING DRY VACUUM CLEANING COMPRESSED AIR (WC OR PSIG) TEMPERED WATER SUPPLY SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. EQUIPMENT INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. TU-XL.## ø DIAMETER, PHASE °F DEGREES FAHRENHEIT EEW EMERGENCY EYEWASH A COPRESSED AIR EWC ELECTRIC WATER COOLER OD OUTSIDE DIAMETER OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED OSD OPEN SITE DRAIN AD AREA DRAIN, ACCESS DOOR EX EXISTING OZ OUNCE AFF ABOVE FINISHED FLOOR P PUMP AGA AMERICAN GAS ASSOCIATION FCO FLOOR CLEANOUT PC PLUMBING CONTRACTOR PD PRESSURE DROP FD FLOOR DRAIN, FIRE DAMPER PE POLYETHYLENE FDC FIRE DEPARTMENT CONNECTION PH PHASE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE PIV POST INDICATOR VALVE FH FUME HOOD PPM PARTS PER MILLION AP ACID PROOF, ACCESS PANEL FHC FIRE HOSE CABINET PRV PRESSURE REDUCING VALVE APPROX. APPROXIMATELY FLR FLOOR PSI POUNDS PER SQUARE INCH ARCH ARCHITECT FM FACTORY MUTUAL PSIG POUNDS PER SQUARE INCH GAUGE FPM FEET PER MINUTE PVC POLYVINYL CHLORIDE FSC FIRE SUPPRESSION CONTRACTOR ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS FT FOOT, FEET ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS FTG FOOTING RCP REINFORCED CONCRETE PIPE AUTO AUTOMATIC G NATURAL GAS RD ROOF DRAIN AVG AVERAGE GA GAGE OR GAUGE AVS ACID VENT STACK GAL GALLON AW ACID WASTE GC GENERAL CONTRACTOR AWWA AMERICAN WATER WORKS ASSOCIATION GPD GALLONS PER DAY RM ROOM GPH GALLONS PER HOUR GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE BF BARRIER FREE BFC BELOW FINISHED CEILING BHP BRAKE HORSEPOWER GT GREASE TRAP BLDG BUILDING HB HOSE BIBB HD HEAD (FT.) SAN SANITARY BOP BOTTOM OF PIPING Hg MERCURY BSMT BASEMENT BT BATHTUB HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR BTM BOTTOM BtuH BRITISH THERMAL UNIT PER HOUR HP HORSEPOWER, HEAT PUMP CA COMPRESSED AIR HR HOUR(S) SK SINK CB CATCH BASIN HYD WALL HYDRANT Hz HERTZ CD CONDENSATE DRAIN SPEC SPECIFICATION CO CARBON DIOXIDE ID INSIDE DIAMETER IE INVERT ELEVATION CFM CUBIC FEET PER MINUTE IN INCH, INCHES INT INTERIOR SS SERVICE SINK, STAINLESS STEEL INV INVERT STD STANDARD CI CAST IRON IPS INTERNATIONAL PIPE STANDARD CMP CORRUGATED METAL PIPE IW INDIRECT WASTE CO CLEANOUT KEC KITCHEN EQUIPMENT CONTRACTOR kW KILOWATT LAB LABORATORY TEMP TEMPERATURE CP CICRULATOR PUMP CPVC CHLORINATED POLYVINYL CHLORIDE L LAVATORY LBS POUNDS TMV THERMOSTATIC MIXING VALVE LF LINEAR FEET LP LIQUID PETROLEUM TP TRAP PRIMER TS TAMPER SWITCH CW COLD WATER CWP CONDENSER WATER PUMP MAX MAXIMUM TYP TYPICAL DBP DOMESTIC BOOSTER PUMP MB MOP BASIN DCVA DOUBLE CHECK VALVE ASSEMBLY MBH THOUSAND Btu PER HOUR MC MECHANICAL CONTRACTOR UL UNDERWRITERS LABORATORIES DH DRENCH HOSE MCA MINIMUM CIRCUIT AMPS UON UNLESS OTHERWISE NOTED UR URINAL DIA DIAMETER MFR MANUFACTURER DN DOWN MH MANHOLE V VOLTS, VENT MIN MINIMUM VAC VACUUM DS DOWNSPOUT MISC MISCELLANEOUS DW DISTILLED WATER VB VACUUM BREAKER DWG DRAWING DWV DRAIN, WASTE & VENT N NITROGEN NA NOT APPLICABLE EA EACH NC NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF EC ELECTRICAL CONTRACTOR NFC NATIONAL FIRE CODE ECO EXTERIOR CLEANOUT NFPA NATIONAL FIRE PROTECTION ASSOCIATION W WASTE, WATT WC WATER COLUMN, WATER CLOSET NIC NOT IN CONTRACT NO NORMALLY OPEN, NITROUS OXIDE EFF EFFICIENCY NOM NOMINAL WCO WALL CLEANOUT NP NON-POTABLE WATER EL ELEVATION NTS NOT TO SCALE O OXYGEN ES EMERGENCY SHOWER YD YARD DRAIN FLOW DIRECTION ARROW, PITCH DIRECTION ARROW PIPE RISE PIPE DROP PIPE CAP PIPE CONTINUES (REFERENCE ELSEWHERE) PIPE GUIDE PIPE ANCHOR EXPANSION LOOP UNION, FLANGED UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE PLUG VALVE CHECK VALVE PRESSURE REDUCING VALVE REDUCED PRESSURE BACKFLOW PREVENTER DOUBLE CHECK BACKFLOW PREVENTER DOUBLE DETECTOR CHECK VALVE ASSEMBLY ANGLE VALVE RELIEF VALVE VALVE WITH OUTSIDE STEM & YOKE SOLENOID VALVE FLOW SWITCH PRESSURE SWITCH AQUASTAT BALANCE VALVE STRAINER STRAINER WITH CAPPED BLOWDOWN MANUAL AIR VENT AUTOMATIC AIR VENT VACUUM BREAKER TEMPERATURE/PRESSURE TAP THERMOMETER PRESSURE GAUGE AIR FILTER/DRYER INLINE PUMP WATER HAMMER ARRESTER WITH SCHEDULE TYPE P-TRAP AND RISER FLOOR DRAIN WITH SIZE & SCHEDULE TYPE END OF PIPE CLEANOUT FLOOR CLEANOUT WALL CLEANOUT EXTERIOR CLEANOUT OR RODDING HOLE HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE WATER METER GAS METER ROOF DRAIN, OVERFLOW DRAIN WITH SIZE POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION VALVE TAMPER SWITCH UPRIGHT SPRINKLER HEAD PENDANT SPRINKLER HEAD DRY PENDANT SPRINKLER HEAD CONCEALED SPRINKLER HEAD SIDEWALL SPRINKLER HEAD THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS TO REMAIN. INTERMEDIATE DASHED LINETYPE INDICATE EXISTING ITEMS TO BE REMOVED. INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE NEW ITEMS. THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE. INDICATES POINT OF NEW CONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. PIPING LINE SYMBOLS REFERENCE SYMBOLS ABBREVIATIONS AND TERMS PIPING IDENTITY SYMBOLS LINETYPE DESIGNATORS DRAWING BLOCK TITLE SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET KEYNOTE INDICATORS EQUIPMENT TYPE NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO ASSOCIATED AIR HANDLER (OPTIONAL) AREA LEADER LINE LEADER POINT LEADER DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) REVISION CLOUD REVISION INDICATOR NUMERIC SCALE SEE P-102 REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN PLAN NUMERIC CHARACTER RELATES TO ITEM NORTH ARROW BEYOND AREA EXTENSION ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) SCALE: 1/8" = 1'-0" M G CO 4"RD 4"OFD DVC WVC N0 N 0 MV MA GV LP G F DE DI CL CSW 140°F 140°F PD D AV AW CD ST FM SG IW A TW CO NPW FD HB-1 WH-1 FCO 2"FD-1 WCO WHA-A M S P T F TS X XX X X X X X X X X 2 N WB WASHER BOX ECO DF DRINKING FOUNTAIN HW HOT WATER HWR HOT WATER RETURN GW GREASE WASTE HX HEAT EXCHANGER OW OIL WASTE PP POLYPROPYLENE PW PURE WATER RPBP REQUIRED PRESSURE BACKFLOW PREVENTER SG SPECAIL GAS SH SHOWER TD TRENCH DRAIN T TURRET TDH TOTAL DYNAMIC HEAD TET THERMAL EXPANSION TANK GENERAL NOTES WSB WATER SUPPLY BOX A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS AS IF REPEATED HEREIN. B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. H. ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. I. ALL CONFLICTS, WHICH MAY PREVENT THE COMPLETION OF WORK AS INTENDED, SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. THE CONTRACTOR SHALL NOT PROCEED WITH ANY RELATED WORK UNTIL ALL CONFLICTS ARE RESOLVED AND THE CLARIFYING INFORMATION IS ISSUED TO THE CONTRACTOR BY THE ARCHITECT. J. PROVIDE NFPA APPROVED FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. K. FIELD VERIFICATION: CONTRACTOR SHALL INSPECT AND VERIFY ALL EXISTING FIELD CONDITIONS, CLEARANCES AND DIMENSIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF EXISTING CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT ARCHITECT/ENGINEER BEFORE PROCEEDING WITH ANY WORK. GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL PLUMBING NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. NOTATION DESIGNATORS DEMOLITION NOTES A. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. B. CONTRACTOR SHALL COORDINATE SHUT DOWN OF ANY PLUMBING SYSTEM WITH THE OWNER AND ANY AUTHORITY HAVING JURISDICTION. C. CONTRACTOR SHALL PROVIDE TEMPORARY CAPS FOR ALL SERVICES AS REQUIRED SO EXISTING SYSTEMS WILL REMAIN OPERATIONAL. D. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING CONSTRUCTION. ANY FACILITIES DAMAGED OR DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION. E. CONTRACTOR SHALL REPAIR OR REPLACE PIPE INSULATION DAMAGED DURING DEMOLITION OR RENOVATION WORK TO MATCH ORIGINAL CONDITION. F. CONTRACTOR SHALL COORDINATE WITH APPROPRIATE TRADE TO CUT AND PATCH FINISHED AREAS AS REQUIRED, UNLESS OTHERWISE NOTED ON DOCUMENTS. G. CONTRACTOR SHALL REMOVE AND REPLACE CEILINGS, LIGHT FIXTURES, ETC. IN EXISTING BUILDING AS REQUIRED TO PERFORM DEMOLITION AND RENOVATION WORK. AFTER WORK IS COMPLETE, DAMAGED ITEMS SHALL BE REPAIRED TO ORIGINAL CONDITION OR REPLACED. H. CONTRACTOR SHALL REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEW CONSTRUCTION AND/OR RENOVATION. I. CONTRACTOR SHALL THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK. ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COST TO OWNER. J. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. FIRE PROTECTION NOTES A. ALL FIRE PROTECTION WORK ON THE DRAWINGS IS NEW AND BY THIS CONTRACTOR UNLESS OTHERWISE INDICATED. B. THE FIRE PROTECTION CONTRACTOR SHALL FURNISH ALL REQUIRED LABOR AND PROVIDE ALL MATERIAL, EQUIPMENT INCLUDING ALL CONTRACTOR'S SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF THE REQUIRED SYSTEMS IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED INSTALLATION SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR COMPLETE AND OPERATIONAL SYSTEMS. C. FIRE PROTECTION SYSTEM FOR BUILDING SHALL BE DESIGNED FOR LIGHT HAZARD, 0.10 GPM PER SQUARE FOOT OVER 1,500 SQUARE FEET. MECHANICAL, STORAGE AND LAB AREAS SHALL BE DESIGNED FOR ORDINARY HAZARD, 0.15 GPM PER SQUARE FOOT OVER 1,500 SQUARE FEET. D. SPRINKLER SYSTEM SHALL BE HYDRAULLICALLY CALCULATED, FULLY SUPERVISED AND INSTALLED ACCORDING TO NFPA 13. E. THE FIRE PROTECTION CONTRACTOR SHALL OBTAIN FLOW TEST DATA BY MEANS OF A FLOW TEST PRIOR TO DESIGN HYDRAULIC CALCULATION OF SPRINKLER SYSTEM. F. CUTTING AND PATCHING, AND CORE DRILLING FOR FIRE PROTECTION WORK SHALL BE THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR. G. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE AND DESIGN. H. PROVIDE UPRIGHT HEADS IN UNFINISHED SPACES (I.E.: THOSE WITH EXPOSED STRUCTURE), RECESSED PENDENT HEADS IN FINISHED SPACES (I.E.: THOSE WITH LAY-IN OR HARD CEILINGS), SIDEWALL HEADS WHERE IMPRACTICAL TO INSTALL PENDENT OR UPRIGHT TYPE, OR AS INDICATED OTHERWISE ON THE DRAWINGS. I. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF CEILING MOUNTED ITEMS. J. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDING WALK-THRU'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE END OF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL AND IS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEM REQUIRED AS A RESULT OF THIS BUILDING INSPECTION. K. SEISMIC RESTRAINTS: IF THE SEISMIC DESIGN CATEGORY FOR THE BUILDING IS "C" OR WORSE, THEN THE FIRE PROTECTION SPRINKLER SYSTEM AND SUPPORTS SHALL BE DESIGNED AND INSTALLED FOR THE SEISMIC FORCES IN ACCORDANCE WITH THE BUILDING CODE. L. ELEVATOR EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS THROUGH ELEVATOR EQUIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR EQUIPMENT ROOMS, DO NOT ROUTE OVER ELEVATOR EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS. M. ELECTRICAL EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS OVER ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS. N. DO NOT ROUTE ANY SYSTEMS ABOVE ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. PLUMBING NOTES A. ALL WORK ON THE PLUMBING DRAWINGS IS NEW AND BY THIS CONTRACTOR UNLESS OTHERWISE INDICATED. B. THE PLUMBING CONTRACTOR SHALL INCLUDE IN HIS BID ALLOWANCES, FEES, AND COSTS TO COMPLETE THIS PROJECT. C. THE PLUMBING CONTRACTOR SHALL FURNISH ALL REQUIRED LABOR AND PROVIDE ALL MATERIAL, EQUIPMENT INCLUDING ALL CONTRACTOR'S SERVICES NECESSARY TO COMPLETE INSTALLATION OF THE REQUIRED SYSTEMS IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED INSTALLATION SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR COMPLETE AND OPERATIONAL SYSTEMS. D. ALL PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF THE INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH THE LATEST INDIANA AMENDMENTS). E. ALL SOIL, WASTE, VENT, AND STORM PIPING SHALL BE INSTALLED AT THE FOLLOWING MINIMUM SLOPE:1/8" (1%) PER FOOT GRADE FOR PIPE SIZES 3" AND LARGER. 1/4" (2%) PER FOOT GRADE FOR PIPE SIZES 21/2" AND SMALLER. F. CUTTING AND PATCHING, AND CORE DRILLING FOR PLUMBING WORK SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR. G. PIPING AND/OR EQUIPMENT SHALL NOT BE SUPPORTED FROM STRUCTURAL MEMBERS WITHOUT PRIOR REVIEW AND APPROVAL FROM THE STRUCTURAL ENGINEER. H. ALL DOMESTIC WATER PIPING SHALL BE INSULATED. REFER TO INSULATION SCHEDULE IN SPECIFICATIONS. I. ALL PLUMBING FIXTURES AND EQUIPMENT SHALL CONFORM TO ALL APPLICABLE ENERGY CONSERVATION CODES. J. ALL PIPING, VALVES, AND ACCESSORIES SERVING EQUIPMENT SHALL CONFORM TO ALL APPLICABLE ENERGY CONSERVATION CODES. K. ANCILLARY SYSTEMS NOT ASSOCIATED WITH EQUIPMENT SHALL NOT BE INSTALLED SO AS TO INHIBIT SERVICING AND/OR REMOVAL OF SAID EQUIPMENT. L. STERILIZE DOMESTIC WATER PIPING SYSTEM IN ACCORDANCE WITH STATE AND LOCAL CODES, AND BASE BUILDING SPECIFICATIONS. M. PRIOR TO THE INSTALLATION, FABRICATION, REMOVAL, OR RELOCATION OF ANY WORK, THE CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE ACTUAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND SHALL FULLY COORDINATE ALL WORK WITH THE ARCHITECTURAL PLANS, BUILDING STRUCTURE, AND WORK OF ALL OTHER TRADES. CONTRACTOR SHALL VERIFY EXISTING INVERTS PRIOR TO CONSTRUCTION. N. FOUNDATION AND FOOTINGS SHALL NOT BE DISTURBED WITHOUT OBTAINING PERMISSION FROM THE ARCHITECT AND/OR STRUCTURAL ENGINEER. PROPER UNDERPINNING METHODS SHALL BE USED TO PROTECT AFFECTED FOUNDATION COMPONENTS. O. PROVIDE PIPE ESCUTCHEONS AT EXPOSED PIPE PENETRATIONS AT ALL FINISHED WALLS AND CEILINGS. P. PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHT WALLS. Q. PROVIDE A CHECK VALVE ON HOT AND COLD WATER BRANCH LINES SERVING ALL MOP SINKS. R. PROVIDE WATER HAMMER ARRESTERS PRIOR TO QUICK-CLOSING VALVES (ie: ELECTRIC, PNEUMATIC, SPRING LOADED VALVES OR DEVICES, QUICK HAND CLOSURE VALVES OR FIXTURE TRIM). SIZE ARRESTERS PER SCHEDULE ON DRAWINGS AND PDI-WH 201 CERTIFIED STANDARD. S. INSULATE ALL PLASTIC PIPING IN RETURN AIR PLENUMS TO MAINTAIN 25/50 FIRE SMOKE RATING AND AS DIRECTED IN SPECIFICATIONS. INSULATION MATERIAL SHALL BE 1/2" CLOSED CELL ELASTOMERIC, UNLESS OTHERWISE INDICATED IN PART 3 OF SPECIFICATION SECTION 220700. T. COORDINATE VENT PENETRATIONS WITH MECHANICAL ROOF TOP EQUIPMENT, REFER TO "H" SERIES DRAWINGS. OFFSET VENTS AS REQUIRED TO MAINTAIN MINIMUM 10'-0" SEPARATION FROM AIR INTAKES. U. PROVIDE "LEAD-FREE", "NO-LEAD", AND/OR "LOW -LEAD" PLUMBING FITTINGS COMPLIANT WITH THE FEDERAL LAW IN EFFECT ON JANUARY 4, 2014 - MAXIMUM 0.25% LEAD CONTENT. V. PROVIDE FREEZE PROTECTION FOR ALL DOMESTIC WATER PIPING AND TRAPS INSTALLED IN UNHEATED AREAS. USE ELECTRIC HEAT TRACE CABLE AND INCLUDE ALL ACCESSORIES FOR A COMPLETE AUTOMATIC OPERATING FREEZE PROTECTION SYSTEM. COVER WITH INSULATION. ALL HEAT TRACING COMPONENTS SHALL BE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR. FINAL CONNECTION TO THE ELECTRICAL SYSTEM SHALL BE MADE BY THE ELECTRICAL CONTRACTOR. W. ELEVATOR EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS THROUGH ELEVATOR EQUIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR EQUIPMENT ROOMS, DO NOT ROUTE OVER ELEVATOR EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS. X. TELECOMMUNICATIONS ROOMS:(MDF AND IDF) DO NOT ROUTE ANY SYSTEMS OVER EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS. Y. ELECTRICAL EQUIPMENT ROOMS:DO NOT ROUTE ANY SYSTEMS OVER ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCESS. Z. DO NOT ROUTE ANY SYSTEMS ABOVE ELECTRICAL EQUIPMENT OR ELECTRICAL COMPONENTS. W V RADON R NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET P000SYMBOLS ANDABBREVIATIONSNORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE 07/08/21