HomeMy WebLinkAboutP501 - PLUMBING DETAILSBALL VALVE REDUCED PRESSURE BACKFLOW PREVENTER, MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. BALL VALVE TO SYSTEM FROM WATER SUPPLY SOURCE AIR GAP DRAIN FUNNEL PIPE DISCHARGE TO FLOOR DRAIN OR MOP SINK SINK SHUT-OFF VALVE REDUCER GARBAGE DISPOSAL 5/8" DRAIN HOSE 1 -1/2" VENT 2" SAN DISHWASHER 1/2" HW CW SUPPLY HW SUPPLY COUNTERTOP INSTALL AS HIGH AS POSSIBLE UNDER COUNTERTOP CODE APPROVED AIR ADMITTANCE VALVE R HW DOMESTIC TANK TYPE ELEC. WATER HEATER (DWH-1 & DWH-2) HVAC FURNACE CW HW CWHWCWUNIT MECHANICAL CLOSET TO FIXTURES IN UNIT 3/4"CW 3/4"HW 3/4"CW 3/4"CW 3/4"HW 3/4"CW WALL THERMOMETER WALL SEE FLOOR PLAN AND DETAIL ON P-501 FOR SIZE OF COLD WATER PIPE MAINS CEILING 3"X2" HUB DRAIN FINISH FLOOR DRAIN PAN FULL SIZE DRAIN VALVE FULL SIZE TO HUB DRAIN ASME T&P RELIEF VALVE HEAT TRAPS WATER HAMMER ARRESTOR STRAIGHT PIPING FOR UNIT SUBMETER (OFCI) BALL VALVE WITH RELIEF VALVE EQUAL TO WATTS #LFBRV DRAIN TUBE TO HUB DRAIN SLOPE RISER PIPE SAME AS SEWER 18"x18"x4" THICK CONCRETE PAD ROUND FLANGED HOUSING W/ HEAVY DUTY CAST IRON COVER LIKE J.R. SMITH 4251 CLEANOUT PLUGFINISH GRADE AT REFRIGERATORS -12" AFF. REFRIGERATOR ICE MAKER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO OATEY SERIES RECESSED WALL BOXES. ANGLE STOP VALVE WITH THREADED CONNECTION FOR ICE MAKER TUBING 1/2"CW FLOOR LINE BFP 4"CW FLOOR TYPICAL DRAIN FUNNEL WITH AIR GAP, TERMINATE DRAIN LINE OVER NEAREST FLOOR DRAIN PIPE SUPPORTS TYPTHRUST BLOCK INCOMING SERVICE GATE VALVE REDUCED PRESSURE ZONE TYPE BACKFLOW PREVENTER (BFP) TYP. NOTE: 1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'S REQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED.MAX.MOUNTINGHEIGHTOF 5'-0"ABOVEFLOORPRESSURE GAUGE PIPE DOUBLE SUPPORT NUT LOCKING NUT HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUTCLEVIS HANGER 14 GAUGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG PIPE INSULATION INSULATION PREFORMED PIPE SUPPORT INSERT, SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS PURPOSE.12"PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR BASED ON CARLISLE U-8-A. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOK DECK -SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION.OPENING IN DECK BY PLUMBING CONTRACTOR. SEE DRAWINGS FOR SIZE INCREASER AS REQUIRED PIPE SIZE PER DRAWINGS FIRST FLOOR ROOFSECOND FLOOR NOTE: PROVIDE SHUTOFF VALVES AS SHOW. THIRD FLOOR 3/4"CW TO RESIDENTIAL UNIT. REFER TO DETAIL #2 ON SHEET P-501 FOR ADDITIONAL INFORMATION 1 1/2" COLD WATER BRANCH FROM MAIN IN CORRIDOR TO RESIDENTIAL UNITS1"CW 3/4"CW TO RESIDENTIAL UNIT. REFER TO DETAIL #2 ON SHEET P-501 FOR ADDITIONAL INFORMATION 3/4"CW TO RESIDENTIAL UNIT. REFER TO DETAIL #2 ON SHEET P-501 FOR ADDITIONAL INFORMATION 3/4"CW 3/4"CW FIRST FLOOR ROOFSECOND FLOOR THIRD FLOOR 3/4" COLD WATER BRANCH FROM MAIN IN CORRIDOR TO RESIDENTIAL UNITS 3/4"CW 3/4"CW TO RESIDENTIAL UNIT. REFER TO DETAIL #2 ON SHEET P-501 FOR ADDITIONAL INFORMATION 3/4"CW TO RESIDENTIAL UNIT. REFER TO DETAIL #2 ON SHEET P-501 FOR ADDITIONAL INFORMATION 3/4"CW 1" COLD WATER BRANCH FROM MAIN IN CORRIDOR TO RESIDENTIAL UNITS.MIN OF 10"FINISH HEIGHT OF ROOF HYDRANT TO BE MIN OF 3'-0" A.F.R. ROOF MEMBRANE 1/8" N.P.T. DRAIN HOLE CONNECT TO 1/2" DRAIN PIPE AND TERMINATE OVER FLOOR DRAIN 3/4" COLD WATER PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOF DECK -SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION OPENING IN DECK BY PLUMBING CONTRACTOR HEAD CASTING DUAL CHECK VALVE 3/4" HOSE CONNECTION HANDLE WATER TIGHT SEAL UNDER DECK FLANGE MOUNTING BOLTS (4) CONTROL PANEL AND VFD'S TYPICAL FLEXIBLE CONNECTOR FLOOR CONCRETE HOUSEKEEPING PAD NORMALLY OPEN FULL LINE SIZE BY-PASS SHUT-OFF VALVE AND CHECK VALVE TYPICAL SHUT OFF VALVE TYPICAL CHECK VALVE CW TO BUILDING SERVICE CW FROM BFP'S, AND WATER METERS NOTE: REFER TO SCHEDULE FOR ACTUAL QUANTITY AND TYPE OF PUMPS. TYPICAL PUMP 12" = 1'-0" Backflow Preventer Detail 1 NOT TO SCALE Dishwasher/Disposal and Sink Detail3 NOT TO SCALE Domestic Electric Water Heater in Unit Mech. Closet Detail2 NOT TO SCALE Exterior Cleanout Detail4 12" = 1'-0" Ice Maker Recessed Wall Box Detail 5 NOT TO SCALE Multiple Water Meter Piping Detail6 NOT TO SCALE Pipe Hanger Detail 8 NOT TO SCALE Vent Through Roof Detail 9 NOT TO SCALE Typical Residential Unit CW Supply Riser 10 NOT TO SCALE Notch and Bored Holes In Wall Studs Detail 7 NOT TO SCALE Roof Hydrant Detail 11 12" = 1'-0" WATER BOOSTER PUMP PIPING DETAIL 12 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET P501PLUMBING DETAILS NORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE 1 BID DOCUMENT 01/15/2021 1 07/08/21