HomeMy WebLinkAboutP501 - PLUMBING DETAILSBALL VALVE
REDUCED PRESSURE BACKFLOW
PREVENTER, MAXIMUM
MOUNTING
HEIGHT OF 5'-0" ABOVE FLOOR.
BALL VALVE
TO SYSTEM
FROM WATER
SUPPLY
SOURCE
AIR GAP DRAIN FUNNEL
PIPE DISCHARGE TO FLOOR DRAIN OR MOP SINK
SINK
SHUT-OFF VALVE
REDUCER
GARBAGE
DISPOSAL
5/8" DRAIN
HOSE
1 -1/2" VENT
2" SAN
DISHWASHER
1/2" HW
CW SUPPLY
HW SUPPLY
COUNTERTOP
INSTALL AS HIGH AS
POSSIBLE UNDER
COUNTERTOP
CODE APPROVED AIR
ADMITTANCE VALVE
R
HW
DOMESTIC
TANK TYPE
ELEC. WATER
HEATER
(DWH-1 & DWH-2)
HVAC FURNACE
CW
HW
CWHWCWUNIT
MECHANICAL
CLOSET
TO FIXTURES
IN UNIT
3/4"CW
3/4"HW 3/4"CW
3/4"CW
3/4"HW
3/4"CW
WALL
THERMOMETER
WALL
SEE FLOOR PLAN
AND DETAIL ON P-501
FOR SIZE OF COLD
WATER PIPE MAINS
CEILING
3"X2" HUB DRAIN
FINISH FLOOR
DRAIN PAN
FULL SIZE DRAIN VALVE
FULL SIZE TO HUB DRAIN
ASME T&P RELIEF VALVE
HEAT TRAPS
WATER
HAMMER
ARRESTOR
STRAIGHT PIPING FOR
UNIT SUBMETER (OFCI)
BALL VALVE WITH RELIEF VALVE
EQUAL TO WATTS #LFBRV
DRAIN TUBE TO HUB DRAIN
SLOPE
RISER PIPE SAME AS SEWER
18"x18"x4" THICK CONCRETE PAD
ROUND FLANGED HOUSING
W/ HEAVY DUTY CAST IRON
COVER LIKE J.R. SMITH 4251
CLEANOUT PLUGFINISH GRADE
AT REFRIGERATORS -12" AFF.
REFRIGERATOR ICE MAKER
RECESSED WALL BOX WITH
FACE PLATE; EQUAL TO OATEY
SERIES RECESSED WALL BOXES.
ANGLE STOP VALVE WITH
THREADED CONNECTION
FOR ICE MAKER TUBING
1/2"CW
FLOOR LINE
BFP
4"CW FLOOR
TYPICAL DRAIN FUNNEL WITH
AIR GAP, TERMINATE DRAIN
LINE OVER NEAREST FLOOR
DRAIN
PIPE
SUPPORTS TYPTHRUST BLOCK
INCOMING
SERVICE
GATE VALVE
REDUCED PRESSURE ZONE
TYPE BACKFLOW
PREVENTER (BFP) TYP.
NOTE:
1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH
UTILITY COMPANY'S REQUIREMENTS. WATER METER
FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED.MAX.MOUNTINGHEIGHTOF 5'-0"ABOVEFLOORPRESSURE GAUGE
PIPE
DOUBLE SUPPORT NUT
LOCKING NUT
HANGER ROD HANGER ROD
LOCKING NUT
SUPPORT NUTCLEVIS HANGER
14 GAUGE ZINC
COATED
SHEET STEEL SADDLE
AT LEAST 12" LONG
PIPE
INSULATION
INSULATION
PREFORMED PIPE SUPPORT INSERT,
SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS
PURPOSE.12"PENETRATION BOOT & FLASHING TO
MEMBRANE ROOFING BY ROOFING
CONTRACTOR BASED ON CARLISLE
U-8-A. REFER TO MANUFACTURER'S
RECOMMENDATIONS FOR INSTALLATION.
PROVIDE STAINLESS STEEL
CLAMPING BAND
SURE SEAL WATER CUT-OFF MASTIC
ROOK DECK -SEE
ARCHITECTURAL
DRAWINGS FOR CONSTRUCTION.OPENING IN DECK BY
PLUMBING
CONTRACTOR.
SEE DRAWINGS FOR SIZE
INCREASER AS REQUIRED
PIPE SIZE PER DRAWINGS
FIRST FLOOR
ROOFSECOND FLOOR
NOTE: PROVIDE SHUTOFF
VALVES AS SHOW.
THIRD FLOOR
3/4"CW TO RESIDENTIAL UNIT.
REFER TO DETAIL #2 ON SHEET
P-501 FOR ADDITIONAL
INFORMATION
1 1/2" COLD WATER BRANCH FROM
MAIN IN CORRIDOR TO RESIDENTIAL
UNITS1"CW
3/4"CW TO RESIDENTIAL UNIT.
REFER TO DETAIL #2 ON SHEET
P-501 FOR ADDITIONAL
INFORMATION
3/4"CW TO RESIDENTIAL UNIT.
REFER TO DETAIL #2 ON SHEET
P-501 FOR ADDITIONAL
INFORMATION
3/4"CW
3/4"CW
FIRST FLOOR
ROOFSECOND FLOOR
THIRD FLOOR
3/4" COLD WATER BRANCH FROM MAIN
IN CORRIDOR TO RESIDENTIAL UNITS
3/4"CW
3/4"CW TO RESIDENTIAL UNIT.
REFER TO DETAIL #2 ON SHEET
P-501 FOR ADDITIONAL
INFORMATION
3/4"CW TO RESIDENTIAL UNIT.
REFER TO DETAIL #2 ON SHEET
P-501 FOR ADDITIONAL
INFORMATION
3/4"CW
1" COLD WATER BRANCH
FROM MAIN IN CORRIDOR
TO RESIDENTIAL UNITS.MIN OF 10"FINISH HEIGHT OF
ROOF HYDRANT TO BE
MIN OF 3'-0" A.F.R.
ROOF MEMBRANE
1/8" N.P.T. DRAIN HOLE
CONNECT TO 1/2"
DRAIN PIPE
AND TERMINATE OVER
FLOOR
DRAIN
3/4" COLD WATER
PENETRATION BOOT & FLASHING TO
MEMBRANE ROOFING BY ROOFING
CONTRACTOR. REFER TO MANUFACTURER'S
RECOMMENDATIONS FOR INSTALLATION
PROVIDE STAINLESS STEEL
CLAMPING BAND
SURE SEAL WATER CUT-OFF MASTIC
ROOF DECK -SEE
ARCHITECTURAL
DRAWINGS FOR
CONSTRUCTION
OPENING IN DECK BY
PLUMBING
CONTRACTOR
HEAD CASTING
DUAL
CHECK
VALVE
3/4" HOSE CONNECTION
HANDLE
WATER TIGHT SEAL
UNDER DECK FLANGE
MOUNTING BOLTS (4)
CONTROL PANEL
AND VFD'S
TYPICAL FLEXIBLE
CONNECTOR
FLOOR
CONCRETE HOUSEKEEPING PAD
NORMALLY OPEN FULL
LINE SIZE BY-PASS
SHUT-OFF VALVE
AND CHECK VALVE
TYPICAL SHUT OFF VALVE
TYPICAL CHECK VALVE
CW TO
BUILDING
SERVICE CW FROM BFP'S, AND
WATER METERS
NOTE: REFER TO SCHEDULE FOR ACTUAL QUANTITY AND TYPE OF PUMPS.
TYPICAL
PUMP
12" = 1'-0"
Backflow Preventer Detail 1
NOT TO SCALE
Dishwasher/Disposal and Sink Detail3
NOT TO SCALE
Domestic Electric Water Heater in Unit Mech. Closet Detail2
NOT TO SCALE
Exterior Cleanout Detail4
12" = 1'-0"
Ice Maker Recessed Wall Box Detail 5
NOT TO SCALE
Multiple Water Meter Piping Detail6
NOT TO SCALE
Pipe Hanger Detail 8
NOT TO SCALE
Vent Through Roof Detail 9
NOT TO SCALE
Typical Residential Unit CW Supply Riser 10
NOT TO SCALE
Notch and Bored Holes In Wall Studs Detail 7
NOT TO SCALE
Roof Hydrant Detail 11
12" = 1'-0"
WATER BOOSTER PUMP PIPING DETAIL 12 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID SET
P501PLUMBING DETAILS NORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE
1 BID DOCUMENT 01/15/2021
1
07/08/21