HomeMy WebLinkAboutS0-4B-STANDARD ELEVATED POST-TENSIONED CONCRETE DETAILSW 1.5T1.5T W HT. + 1.5T HT. + 1.5T MILD REINFORCEMENT TO BE DISTRIBUTED WITHIN THE DIMENSION LINES EA. WAY MILD REINFORCEMENT TO BEDISTRIBUTED WITHIN THEDIMENSION LINES EA. WAY1 12 FOR 7" SLABS OR MORE, PLACE ANCHOR UPRIGHT @ MIN 3" O.C. FOR 6 1/2" SLAB OR LESS, PLACE ANCHORS SIDEWAYS @ MIN 6" O.C. 2 STRANDS MIN @ UNSUPPORTED SLAB EDGE, PARALLEL TO DISTRIBUTED TENDONS SLAB EDGE TOP REBAR TYP. @ MAX 12" O.C. DISTRIBUTED TENDON SPACED @ 6X SLAB THICKNESS OR 48" O.C. MAX BANDED TENDONS MAX 4 PER BUNDLE MAX CURVATURE PER DET 30NOTE TWO STRANDS TO PASS DIRECTLY OVER EA. COLUMN EA. WAY LEGEND T = SLAB THICKNESS W = COL. WIDTH H = CAP/DROP DEPTH BELOW SLAB SOFFIT AT FACE OF COLUMN TOP REINF.2 7/8"15 TOP REINFORCEMENT AT EXTERIOR COLUMNS NOT TO SCALE 2' - 2 3/4 "5 1/4" 1' - 4 7/8"4 5/8" 4 3/4" 1' - 4 3/8" 4 5/8" 2' - 1 7/8" LEGEND T = SLAB THICKNESS W = COL. WIDTH H = CAP/DROP DEPTH BELOW SLAB SOFFIT AT FACE OF COLUMN 16 TOP REINFORCEMENT AT INTERIOR COLUMNS NOT TO SCALE MILD REBAR TO BE PLACES WITHIN DIM. LINES EA. WAY MILD REBAR TO BEPLACES WITHIN DIM.LINES EA. WAYDISTRIBUTED TENDONS SPACED @ 6 X SLAB THICKNESS OR 48" O.C. MAX. UNO BANDED TENDONS. MAX. 4 STRANDS PER BUNDLE TOP REBAR MAX 12" O.C. TOP REBAR (TYP) STAGGER 12" E.W. UNO NOTE: TWO STRANDS MIN. TO PASS DIRECTLY OVER COLUMN EA. WAY3 1/4" 4" 1.5THT. +W 1.5THT. +1 ' - 9 7/8 " 1.5T HT. +W 1.5T HT. + 1' - 9 1/2" 17 SECTION -BANDED TENDONS AT MID-SPAN NOT TO SCALE UNIFORM TENDONS SUPPORT BAR OR SLAB BOLSTER BANDED TENDONS BOTTOM REINF. RE: PLAN 1 #4 CONT.RE: SPECSEQ EQ SUPPORT WIDTH CLR. 2" MIN. A1 B1 C1 A3 B3 C3 A2 B2 C2 TRANSITION TENDON BANDS SLAB NOTE:THE SPAN OF THE TRANSITION TENDON CHANGES FROM L1 AT LINE 1 TO L2 AT LINE 2. PLACE TRANSITION TENDON WITH ITS CONTROL POINTS A3, B3 AND C3, EACH VARYING LINEARLY FROM 1 TO 2 BETWEEN THEIR RESPECTIVE VALUES AT 1 AND 2. TENDON ORDINATES SHOWN ON PLAN TENDON ORDINATES SHOWN ON PLAN GRID GRID L1 2' - 2 3 /8"EQ EQ L2 18 PLACEMENT OF TENDONS IN SPANS OF VARYING LENGTH NOT TO SCALE 2'-6" OVERLAP MIN. BETWEEN #4 BARS. BOTTOM BARS SHALL BE TIED TOGETHER W/ BINDING WIRE @10" O.C. MAX ALONG THE LAP 3/4"2"3/4 V-GROOVE BOTH SIDES OF POUR STRIP 2~#4 X CONT. 1" CLR OF P.T. ANCHOR CUT STRAND AND CAP ANCHORS 3/4" TOOLED JOINT WITH SEALANT BOTH SIDES OF POUR STRIP FOR UP TO 8" THICK SLABS: 6~#4 TOP & BOTTOM FOR SLABS THICKNESSES GREATER THAN 8": 8~#5 TOP & BOTTOM POUR STRIP -PLACE NOT LESS THAN 28 DAYS AFTER FULLY STRESSING P.T. SLAB TENDONS P.T. TENDONSEE NOTE 4 #4 @ 20" O.C. -TOP (EA. SIDE) & #4 @ 12" O.C. -BOT. (EA. SIDE) KEY CONT. OR KEY BETWEEN TENDON ANCHORS VERIFY STRETCHING RAM NOSE CLEARANCE WITH PT SUPPLIER TYP. KEY DETAIL TENDON ANCHOR FOR BANDED OR DISTRIBUTIVE TENDONS REQ'D. PER STD. ANCHORAGE DETAILS SECOND POURFIRST POUR NOTES: 1. AT POUR STRIP, USE FIBER REINFORCED (FORTA FIBER OR EQUIVALENT @ 1.5 LBS/CU. YD.) CONCRETE. 2. AT TOP OF POUR STRIP, PROVIDE 3/4" DEEP TOOLED JOINTS, FILLED WITH SEALANTS, IN TRANSVERSE DIRECTIONS AT 4'-0" O.C. 3. ROUGHEN SLAB EDGES TO 1/4" AMPLITUDE OR PROVIDE SHEAR KEYS BETWEEN ANCHORS, CONTRACTOR OPTIONS. 4. TOP AND BOTTOM LONGITUDINAL BARS IN POUR STRIP TO BE CHAIRED DURING PLACEMENT OF ADJACENT SLABS. RE: BLOW-UP ADD'L #4 BARS EA. SIDE (T&B) 4'-6" MIN. EMBED FOR 19 SLAB POUR STRIP DETAIL NOT TO SCALE MAX. 5'-0" WIDE POUR STRIP 1' - 8 1/2" SDFGHSH CONCRETE HAS ATTAINED DESIGN STRENGTH SLAB TO REMAIN SHORED UNTIL POUR STRIP 3 5/8"RE: PLANADD'L #4 BARS EA. SIDE (T&B) 4'-6" MIN. EMBED FOR 5 1/4"EQEQ 2 1/4" 4 1/2" 1 1/2" 3'- 0"3'- 0"7'-0" 6'-0" 2~ #5 TOP & BOTTOM AS SHOWN TYP. UNO 7 1/4" 7 1/4"20 TRIM BARS AT RE-ENTRANT CORNERS NOT TO SCALE 2'-0"32" 32" 5 #5 12'-0" @ 18"O.C. TOP 5 #5 @ 16" O.C. BOTTOM 1 #5 TOP & BOTTOM CONT. SUPPORT BELOW CONT. SUPPORT BELOW 3 3/4" 21 TRIM BARS AT SUPPORTED SLAB EDGES NOT TO SCALE < 12"18" MIN. RE: PLAN DRAWINGS 12" MIN.3'-0" MIN.2 ~ #5 TOP & BOTTOM TYP. ADDED REINFORCEMENT UNO RE PLAN FOR ADD'L. REINF. 1' - 2 1 /8" 11 3 /8"1' - 0 1/2" 3' - 3 3/4" 22 TRIM BARS AT CANTILEVERED SLAB NOT TO SCALE 1' - 10 1/2" NOTE: UNLESS NOTED OTHERWISE, STAGGER ALL BARS (ALL CONDITIONS) 12" UNLESS SPACE INSUFFICIENT IN WHICH CASE FIELD ADJUST TO LESS STAGGER. BOTTOM REBARS WHERE OCCUR SEE PLAN (EXTEND 1/4 OF INTERIOR SPAN BARS AND 1/3 OF EXTERIOR SPAN BARS (UNLESS NOTED OTHERWISE ON PLAN) CONTINUOUS TO COLUMNS OR SUPPORTS TOP REBAR AT SUPPORT TYP. SUPPORT MID-SPAN SUPPORT STAGGER EQ EQ RE: PLAN STAGGER STAGGER EQ EQ RE: PLAN STAGGERSTAGGER 23 PLAN VIEW -ARRANGEMENT OF REINF. BARS IN SLAB NOT TO SCALE EQ EQ RE: PLAN STAGGER 10'-0" WALL LENGTH 10' -0"10' -0"3'-0"7'-0"#4 @ 12" O.C. ALTERNATE (T) & (B) UNO2 #5 (T) & (B) EDGE OF SLAB/BEAM WALL 24 PLAN -EXTERIOR WALLS ADDITIONAL REBARS FOR CIP / MASONRY BEARING/SHEAR WALLS NOT TO SCALE 8 1/4"2' - 11 7/8"10 3/4"11"11"10' -0" WALL LENGTH RE PLAN 10' -0"10' -0"10' -0" #4 @ 12" O.C. ALTERNATE (T) & (B) 1 #5 X 12'-0" EACH (T) & (B) WALL 8 1/4"2' - 11 7/8"10 3/4"1 ' - 5 1/2"7 3/4"8 3/8" 25 PLAN -INTERIOR WALLS ADDITIONAL REBARS FOR CIP / MASONRY BEARING/SHEAR WALLS NOT TO SCALE 18" OPENING OR CENTER #5 HAIRPIN PLACED RADIALLY TO HOLD TENDONS IN PLANE OF SLAB PLACE OVER CURVED LENGTH OF TENDON AT (72"/NUMBER OF STRANDS) IN. ON CENTER BUT NOT MORE THAN 18 INCHES APART PT SLABPT TENDON RE: PLAN EDGE OF OPENING WHERE IT OCCURS SECTION A TENDON HAIRPIN 5" OF TENDON TURN 1' - 10" CFGHJ 26 TYP. HAIRPIN @ AT TENDON TURNS NOT TO SCALE A<1 12 27 TENDON PLACEMENT FOR TURNS > 1:12 NOT TO SCALE NOTE: WHERE TENDON TURN IS GREATER THAN 1:12 1 -KEEP TENDONS MIN. 2" APART AT TURN 2-PLACE HAIRPIN PER TYP. HAIRPIN DETAIL 2" GAP BETWEEN TENDONS2 1 /2 "2 5/8"12" HORIZONTAL SUPPORT BARS NA PLAN SECTION CHAIRS @ 3'-0" O.C. MAX. DEAD END ANCHORAGES STAGGERED AND PLACED HORIZONTAL IN SLAB #4 x 24" LONG TOP & BOTTOM TIED TO ANCHORAGES SUPPORT BARS BANDED OR DISTRIBUTED TENDONS RE: STANDARD ANCHORAGE DETAILS 1 12 1' - 1" 28 PLACEMENT OF ADDED TENDON NOT TO SCALE 9"4" MIN. 3" 3" 36" STRAIGHT SLAB EDGE SUPPORT BARS WHERE TENDONS TURN PER HAIRPIN PER DET. 27 SYM. MIN. SPACING 4 STRAND MAX. PER BUNDLE TYP. BETWEEN BUNDLES U.N.O. GROMMET AT STRESSING END ONLYTOP & BOTTOM BARS PER ANCHORAGE DETAILS 1' - 5 7 /8"8 5/8 "5 7 /8"6 1/8"1' - 6 3/4" 29 FLARING OF BANDED TENDONS AT SLAB EDGE NOT TO SCALE 3"TYP.3" TYP.3N + 5"30" MIN.30"TYP.SHEAR KEYS 3 1/2"X 1/2" TYP. N, NUMBER OF TENDON ADD 4 # 4 EACH DIRECTION SEE NOTES NOTES: PLAN SECTION - IF BLOCKOUT IS EXPOSED TO WEATHERING AND OR MOISTURE USE GROMMETS; CUT STRESSED STRAND TAILS; PREPARE AND SEAL STRESSING POCKETS AS STIPULATED IN GENERAL NOTES; CAULK JOINT ALL AROUND. - CONTINUE ALL INTERUPTED BARS SHOWN IN PLANS THROUGH THE BLOCKOUT -FILL BLOCKOUT WITH NON-SHRINK CONCRETE OF MIN. SAME STRENGTH AS SLAB. STRAND TAILS SEE NOTES 3 5/8 "1' - 6 1/8"1 5/8" 6 3/4"2' - 11"RE: SPECSCOVER30 STRESSING BLOCKOUT NOT TO SCALE TYPICAL AT ALL CONC. WALLS CONC. WALLS NOT TO SCALE 2 LAYERS OF 40 LB FELT CONT. SLIP JOINT TYP WALL REINF. RE: SXNS CONC. WALL RE:SECTIONS & PLAN 1 1/2" Ø CORRUGATED METAL SLEEVE FILL WITH 5,000 PSI N.S. GROUT AFTER TENDONS ARE STRESSED.EXTEND WALL REINFORCEMENT INTO P.T. SLAB ABOVE TERMINATE 11/2" BELOW T.O.C. WALL ABOVE WHERE NOTED ONPLAN TYPICAL SLIP JOINT DETAIL AT CONCRETE WALLS31 DGH 3'-0" MIN.1' - 1 7/8"3'-0" MIN. #5 @ 12" O.C. NOT TO SCALE NOTE: PENETRATIONS ONLY ALLOWED WHERE SHOWN ON PLAN EDGE OF BEAM CONCRETE COLUMN 3"Ø PLUMBING SLEEVED OPENING ARRANGE PENETRATIONS IN LINE WITH COLUMN DO NOT ARRANGE PENETRATIONS PERPENDICULAR TO COLUMN2'-0" MIN.(TYP.)2'-0" MIN. (TYP.) SLAB SLEEVING PENETRATION DETAIL32 GRID GRID 7 1/2"3" NOTE: 2 RAILS PER SIDE OF COLUMN ARE SHOWN ON PLAN. REFER TO SCHEDULE. NOT TO SCALE HEADED STUD RE: SCHEDULE TYPICAL EDGE COLUMN TYPICAL INTERIOR COLUMN TYPICAL CORNER COLUMN STUD RAIL SCHEDULE, DETAIL AND PLACEMENT33 TYPICAL PENETRATION AROUND STUDRAILS STUD RAIL DETAIL HT.RAIL1ST STUD DIST TO SPAC. STUD1"HT.STUDCOVERTOP2"DIST. TO 1ST STUD STUD SPACING PLATE WIDTH (TYP.) STUD RAIL 2" HEADED STUD RE: SCHEDULE 4 1/2"1 7/8 "4 1/2 "1 7/8"2"2" HEADED STUD RE: SCHEDULE HEADED STUD RE: SCHEDULE NOTE: 2 RAILS PER SIDE OF COLUMN ARE SHOWN ON PLAN. REFER TO SCHEDULE. DIST. TO 1ST STUD STUD SPACING DIST. TO 1ST STUD STUD SPACING NOTE: 2 RAILS PER SIDE OF COLUMN ARE SHOWN ON PLAN. REFER TO SCHEDULE.1 3 /4"NOT TO SCALE 1. ALL HOLDOWN ANCHOR LOCATIONS SHOULD BE SURVEYED BY CONCTRACTOR PRIOR TO CONCRETE PLACEMENT AND BE ATTACHED TO FORMS/REINFORCING AS NEEDED TO PREVENT DISPLACEMENT DURING CONCRETE POUR OPERATION. HOLDOWN ANCHORS SHOULD BE SPOTTED SUCH THAT THEY ARE LOCATED CENTERED EACH WAY ON EMBED PLATES. 2. CAREFUL CONSIDERATION SHOULD BE GIVEN TO THE ASSOCIATED STUD PACK SIZE REQUIRED FOR EACH HOLDOWN ANCHOR TYPE AS THIS AFFECTS ANCHOR ROD OFFSET FROM SHEARWALL ENDS. 3. ALL HOLDOWN EMBEDS SHOULD BE ORIENTED AND ALIGNED WITH WALL FRAMING ABOVE. 4. CONSIDERATION SHOULD BE GIVEN TO EMBED PLATES/ANCHOR BOLT LOCATIONS WHEN INSTALLING PT CABLES AND REINFORCING STEEL, ESPECIALLY ADJACENT TO SLAB EDGES WHERE POCKET FORMERS AND TENDON ANCHORS CAN FOUL INSTALLATION OF HEADED ANCHOR STUDS. 5. TOPS OF EMBED PLATES SHOULD BE LOCATED FLUSH WITH TOP OF FINISH FLOOR. WHERE EMBEDS ARE LOCATED ON CURBS OR DEPRESSED AREAS, THE EMBEDS SHOULD BE PROVIDED AT THE LOWER/DEPRESSED SLAB AREA U.N.O. HOLDOWN RE: APT/ HOTEL DRAWINGS. RE: SHEARWALL ANCHORAGE DETAILS ON THIS SHEET RE: PLAN ADDITIONAL SLAB REINFORCING AT HOLDOWNS TYP. REINFORCEMENT AROUND HOLDOWN34 NOTES: 1. ALL CONDUIT SHALL OCCUR IN THE MIDDLE OF SLAB . 2. ADDITIONAL CONDUIT MAY NOT BE ADDED W/O APPROVAL OF EOR. 3. CONDUIT LOCATIONS SHOWN ON PLAN ARE SCHEMATIC ONLY. CONTRACTOR SHALL SUBMIT FOR EOR REVIEW A FINAL PLAN SHOWING ALL CONDUIT PENETRATIONS AND OTHER EMBEDDED ITEMS DIMENSIONED FOR REVIEW BY A/E. ADDITIONAL REINF. MAY BE REQUIRED. NOT TO SCALE 1 1/4" Ø FLEXIBLE ELECTRICAL CONDUIT. PODIUM SLAB REINF. NOT SHOWN. FLEXIBLE TUBE PENETRATION DETAIL.35 EQ EQTHICKNESSSLABSHEAR WALL HOLD DOWN RE:SHEARWALL PLAN THREADED ROD RE: SCHEDULE EMBED PLATE & H.S. RE: SCHEDULE STRUCTURAL SLAB RE: PLAN 2#4, 1 EA. SIDE OF ANCHOR 6" 2" AS REQ'D 6"AS REQ'D 6"2"EXTERIOR INTERIOR 2#4, EA. WAY 1 EA. SIDE OF ANCHOR (4 TOTAL) 6" 2" 2#4 , 1 EA. SIDE OF ANCHOR PLATE "T" -RE: SCHED. H.S. -RE: SCHED. SLAB EDGE HOLDOWN -RE: PLAN (TYP.) HOLDOWN STUD PACK/POST . RE: WOOD STD. NOTES & ANCHOR BOLT INSTALLATION SCHEDULES. 2-edgeEmbed Capacity (kips)Plate Thickness (in) Studs Plate Capacity ∅Pn 1-edgeCapacity (kips)no-edgeCapacity (kips)2-edge Anchor Capacity (kips) Bolt Bolt Diameter (in) 1-edge Capacity (kips) no-edgeCapacity (kips)Bolt Embed & Grade Bolt Capacity ɸ Pn STUDS STUDS STUDS STUDS STUDS STUDS@ 2X4 @ 2X6 @ 2X4 @ 2X6 @ 2X4 @ 2X6 2X62X4 2X62X4 2X62X4 Studs FramingPlate T W Plate Width (in) INT Length (in) Plate LEXT NOT TO SCALE NOTES: 1. EMBEDDED BOLT ANCHORS SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM F1554 GR. 36. 2. EMBEDDED BOLT ANCHORS SHALL HAVE HEX HEAD OR HEAVY HEX HEAD. 3. NUTS FOR BOLTS SHALL BE ASTM A563A HEX OR ASTM A563A HEAVY HEX WITH ASTM F436 WASHERS. 4. ALL ANCHOR BOLTS SHALL MATCH ANCHOR BOLT DIAMETER SPECIFIED BY HOLDOWN MANUFACTURER. RE: SIMPSON HOLDOWN SCHEDULE. 5. THE ABOVE VALUES ARE APPLICABLE UP TO SEISMIC DESIGN CATEGORY "B". NOTES: 1. ALL PLATES SHALL BE ASTM A36 WITH A MIN. FY-36 KSI. 2. HEADED STUDS SHALL BE NELSON TYPE H4L AND MANUFACTURED IN ACCORDANCE WITH ASTM A108. 3. STUDS SHALL HAVE A MINIMUM STRENGTH OF FY= 51 KSI, AND FU= 65 KSI. 4. STUDS SHALL BE FUSION WELDED TO PLATES IN ACCORDANCE WITH AWS D1.1, FILLET WELDING IS NOT ALLOWED. 5. THREADED RODS SHALL BE FUSION WELDED OR FULL PENETRATION WELDED TO PLATE IN FIELD IN ACCORDANCE WITH AWS D1.1. 6. NUTS FOR BOLTS SHALL BE ASTM A563A HEX OR ASTM A563A HEAVY HEX WITH ASTM F436. 7. THE ABOVE VALUES ARE APPLICABLE UP TO SEISMIC DESIGN CATEGORY "B". NOTE: ADD'L REINF. MAY BE OMMITED, WHEN TOP REINF. IS PRESENT IN SLAB. e = 1 3/4" FOR 2X4 WALLS e = 2 3/4" FOR 2X6 WALLSEP, ABAS REQ'D 1 1/2" MAX.3/4" MIN.RE: HOLDOWNSCHED.EMBEDRE:SCHED.6"Proj.RE: HOLDOWNSCHED.1.51 EMBED PLATES @ SHEARWALL HOLDOWNS 36 SHEARWALL ANCHORAGE DETAILS RE: PLAN FOR HOLDOWN LOCATION MARKED EMBED PLATE DETAIL SCHEMATIC -PLAN VIEW EP1 5/8" EP2 EP3 2~1/2"∅x8" 3/4" 7/8" 2~3/4"∅x8" 2~3/4"∅x8" 10.7 11.0 14.1 14.0 17.1 19.6 20.0 26.4 26.4 AB1 AB2 AB3 5/8" GR36 8" 9.2 9.8 9.8 7/8" GR36 8" 9.0 13.3 20.0 1" GR36 8" 8.9 13.0 26.4 9.8 9.8 9.7 9.8 14.4 14.2 9.8 20.0 26.4 12.5 12.4 15.0 18.0 18.0 21.1 20.0 26.4 26.4 6" 6" 6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2" TYP. L WEQEQ1" CLR..3" MIN. .1" CLR.7 7 /8"7 7 /8"1" CLR.7/8"VARIES eSHEAR WALL HOLD DOWN RE:SHEARWALL PLAN WET SET ANCHOR BOLTS STRUCTURAL SLAB RE: PLAN 6"AS REQ'D 6"2"EXTERIOR INTERIOR 2#4, EA. WAY 1 EA. SIDE OF ANCHOR (4 TOTAL) 6" 2" 2#4 , 1 EA. SIDE OF ANCHOR AS REQ'D RE: HOLDOWNSCHED.WET SET ANCHOR BOLTS @ SHEARWALL HOLDOWNS1" CLR..2" MIN/ .1" CLR.1" CLR.6"7 7 /8"EMBEDRE:SCHED.6"Proj.7 7 /8"6"HNot to Scale SLAB BEAM OR BANDED TENDONS BANDED TENDON OR BEAM ALTERNATE TOP AND BOTTOM SLAB EDGE 600mm (24") #4 @ 12" O.C. 37 Arrangement of Temperature & Shrinkage Reinforcement Between Tendon Bands45°45°6"2' - 4" 2' - 4 1/4" 12777 JONES RD., STE 388 HOUSTON, TX 77070 281 894 7099 CONSTRUCTION@ INTEGRITYSTRUCTURAL.COM in the name of God's one and only Son. This is the verdict: Light has come into the world, but men loved darkness instead of light because their deeds were evil. Everyone who does evil hates the light, and will not come into the light for fear that his deeds will be exposed. But whoever lives by the truth comes into the light, so that it may be seen plainly that what he has done has been done through God. (John 3:16-21, NIV). Therefore Jesus said again, "I tell you the truth, I am the gate for the sheep. All who ever came before me were thieves and robbers, but the sheep did not listen to them. I am the gate; whoever enters through me will be saved. He will come in and go out, and find pasture. The thief comes only to steal and kill and destroy; I have come that they may have life, and have it to the full. (John 10: 7-10, NIV) Jesus answered, "I am the way and the truth and the life. No one comes to the Father except through me." (John 14:6, NIV) These bible verses reflect Integrity Structural Corp.'s strong belief and faith in Jesus Christ and it is our desire that through our work others may come to know Christ as well. May God bless this project and all of those involved.cree en él no es condenado, pero el que no cree ya está condenado por no haber creído en el nombre del Hijo unigénito de Dios. Ésta es la causa de la condenación: que la luz vino al mundo, pero la humanidad prefirió las tinieblas a la luz, porque sus hechos eran perversos. Pues todo el que hace lo malo aborrece la luz, y no se acerca a ella por temor a que sus obras queden al descubierto. En cambio, el que practica la verdad se acerca a la luz, para que se vea claramente que ha hecho sus obras en obediencia a Dios. (Juan 3:16-21,NVI) For God so loved the world the world that he gave his one and only Son, that whoever believes in him shall not perish but have eternal life. For God did not send his Son into the world to condemn the world, but to save the world through him. Whoever believes in him is not condemned, but whoever does not believe stands condemned already because he has not believedThe words around this title block reflect the values and definition of Integrity Structural Corp. and do not include any notes pertaining to the drawings for this project. For God so loved the world that he gave his one and only Son, that whoeverbelieves in him shall not perish but have eternal life. For God did not send his Son into the world to condemn the world, but tosave the world through him. Whoever believes in him is not condemned, but whoever does not believe stands condemned already because he has not believed in the name of God's one and only Son. This is the verdict: Light has come into the world, but men loved darkness instead of light because their deeds were evil. Everyone who does evil hates the light, and will not come intothe light for fear that his deeds will be exposed. But whoever lives by the truth comes into the light, so that it may be seen plainly that what he has done has been done through God. (John 3:16-21, NIV) Porque tanto amó Dios al mundo, que dio a su Hijo unigénito, para que todo el que cree en él no se pierda, sino que tenga vida eterna. Dios no envió a su Hijo al mundo para condenar al mundo, sino para salvarlo por medio de él. El queCAD / ENG PROJECT NAME & LOCATION PROJECT NUMBER DRAWING SCALE SHEET TITLE SHEET NUMBER ISSUE DATE ISSUE TITLE KR / RM12.04.2020 PERMIT SET KR / RM2021.01.15 BID DOCUMENTS 3/4" = 1'-0" STANDARD ELEVATED POST-TENSIONED CONCRETE DETAILS S0 -4B NORTH END APARTMENTS CARMEL, IN 609.003.20H 1 1 04/15/22