HomeMy WebLinkAboutA021 - FLOOR AND ROOF ASSEMBLIESARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 # DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM UL DESIGN - UL L563 (1 HOUR) STC RATING - 50 MIN IIC RATING - 50 MIN A021FLOOR AND ROOFASSEMBLIESAPSHALT SHINGLES CEMENTITIOUS UNDERLAYMENT, 3/4" MIN. 1 8" SOUND MAT ONLY AT AREAS THAT RECEIVE VINYL PLANK FLOORING SHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 18" OPEN WEB FLOOR TRUSS, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. SOUND ATTENUNATION BATT INSULATION (OMIT IN COMMON CORRIDORS AND STAIR LANDINGS AT F3a) 1 2" RESILIENT CHANNEL @ 12" O.C. 5 8 " TYPE 'C' GYPSUM BOARD WOOD SHEATHING PER STRUCTURAL DWGS. ONE LAYER 15# ROOF FELT. EDGE METAL @ BOTTOM OF SLOPED ROOF SHOULD BE OVERLAPPED BY ROOFING FELT. EDGE METAL @ GABLE ENDS SHOULD OVERLAP ROOFING FELT. ROOF TRUSS PER STRUCTURAL DWGS. ONE LAYER OF 5 8" TYPE 'C' GYPSUM BOARD RESILIENT CHANNELS @ 12" O.C.R-38 BLOWN-IN FIBERGLASS INSULATION SCALE: FLOOR ASSEMBLY F1 1 1/2" = 1'-0" 6 MIL UNDERSLAB VAPOR RETARDER COMPACTED SUB-GRADE, SEE CIVIL DWGS. CONCRETE SLAB PER STRUCTURAL DWGS. & STRUCTURAL SPECS FOR FINISH INFO. SCALE: FLOOR ASSEMBLY F3, F3a 1 1/2" = 1'-0" SCALE: ROOF ASSEMBLY R1 1" = 1'-0" USE: SLAB ON GRADE USE: 1 HOUR RATED TYPICAL UPPER FLOOR USE: 1 HOUR RATED PITCHED ROOF SOUND ATTENUNATION BATT INSULATION 1 2" RESILIENT CHANNEL @ 12" O.C. 2 LAYERS 5 8" TYPE 'C' GYPSUM BOARD SCALE: FLOOR ASSEMBLY F4 1 1/2" = 1'-0" USE: 2 HOUR RATED BETWEEN AMENITIES AND UNITS SCALE: ROOF ASSEMBLY R3 1 1/2" = 1'-0" 60 MIL TPO ROOFING ADHERED/ FASTENED TO TAPERED INSULATION PER MANUFACTURER'S REQUIREMENTS TAPERED POLYISOCYANURATE ROOF INSULATION TO ACHIEVE POSITIVE DRAINAGE TO INTERNAL ROOF DRAINS ONE LAYER OF 5 8" TYPE 'C' GYPSUM BOARD RESILIENT CHANNELS @ 12" O.C. R-38 BLOWN-IN FIBERGLASS INSULATION WOOD SHEATHING PER STRUCTURAL DWGS. ROOF TRUSS PER STRUCTURAL DWGS., TOP OF TRUSSES SLOPED TO ACHIEVE POSITIVE DRAINAGE USE: 1 HOUR RATED FLAT ROOF 5 8" TYPE 'C' GYPSUM BOARD UL DESIGN - UL L577 (2 HOUR) STC RATING - 5O MIN IIC RATING - 50 MIN UL DESIGN - UL P522 (1 HOUR)UL DESIGN - UL P522 (1 HOUR) NOTE: SEE A030 SERIES FOR UL ASSEMBLY INFORMATION. NOTE: WHERE CEMENTITIOUS UNDERLAYMENT ISN'T POURED (UNDER TUBS/SHOWERS AND IN DEAD AIR CAVITIES), PROVIDE 1/2" HOMASOTE BOARD OR 15/32" MINIMUM OSB OR PLYWOOD OR 5/8" GP DENSGLASS SHIELD FIRE GUARD TILE BACKER TO MAINTAIN 1 HOUR FLOOR RATING. SCHEDULED FINISH CEMENTITIOUS UNDERLAYMENT, 3/4" MIN. 1 8" SOUND MAT ONLY AT AREAS THAT RECEIVE VINYL PLANK FLOORING SHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. NOTE: WHERE CEMENTITIOUS UNDERLAYMENT ISN'T POURED (UNDER TUBS/SHOWERS AND IN DEAD AIR CAVITIES), PROVIDE 1/2" HOMASOTE BOARD OR 15/32" MINIMUM OSB OR PLYWOOD OR 5/8" GP DENSGLASS SHIELD FIRE GUARD TILE BACKER TO MAINTAIN 1 HOUR FLOOR RATING. SCHEDULED FINISH SCALE: ROOF ASSEMBLY R4 1 1/2" = 1'-0" USE: 1 HOUR RATED ROOF OVER ELEVATOR SHAFT UL DESIGN - GA-FC-5406 (1 HOUR) TWO LAYERS OF 5 8" TYPE 'C' GYPSUM BOARD 60 MIL TPO ROOFING ADHERED/ FASTENED TO TAPERED INSULATION PER MANUFACTURER'S REQUIREMENTS POLYISOCYANURATE ROOF INSULATION TO ACHIEVE R-20 R-VALUE, TAPER TO ACHIEVE POSITIVE DRAINAGE WOOD SHEATHING PER STRUCTURAL DWGS. 2X WOOD FRAMING PER STRUCTURAL DWGS 18" OPEN WEB FLOOR TRUSS, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. ATTIC ATTIC USE: 3-HR RATED CONCRETE PODIUM SCHEDULED FINISH SCALE: FLOOR ASSEMBLY F2, F2a 1 1/2" = 1'-0" SCALE: FLOOR ASSEMBLY B1 1 1/2" = 1'-0" WOOD SHEATHING PER STRUCTURAL DWGS. ONE LAYER 15# ROOF FELT. EDGE METAL @ BOTTOM OF SLOPED ROOF SHOULD BE OVERLAPPED BY ROOFING FELT. EDGE METAL @ GABLE ENDS SHOULD OVERLAP ROOFING FELT. NOTE - ADD ONE LAYER 15# ROOF FELT AT LOW-SLOPE ROOFS. SEE SPECIFICATIONS FOR MORE INFORMATION. ROOF TRUSS PER STRUCTURAL DWGS. APSHALT SHINGLES ONE LAYER OF 5 8" TYPE C EXTERIOR GYPSUM BOARD UL DESIGN - UL P522 (1 HOUR) RESILIENT CHANNEL @ 12" O.C. SCALE: ROOF ASSEMBLY R2 1 1/2" = 1'-0" USE: 1 HOUR RATED TYPICAL BALCONY ROOF USE: BALCONY AT CONCRETE PODIUM PT CONCRETE PODIUM, SLOPE TOP OF CONCRETE TO OUTSIDE FACE OF BALCONY, SEE STRUCTURAL DRAWINGS. SCALE: FLOOR ASSEMBLY B2 1 1/2" = 1'-0" USE: DROPPED CEILING BELOW PODIUM SCALE: CEILING ASSEMBLY C1 1 1/2" = 1'-0" SEE 'F2' ASSEMBLY FOR ADDITIONAL INFORMATION ONE LAYER OF 5 8" TYPE 'C' GYPSUM BOARD DRYWALL CEILING SUSPENSION SYSTEM 1'-4"SPRAY ON OR RIGID INSULATION TO ACHIEVE MIN. R-12.5 AT GARAGE ONLY AT F2A. USE: BALCONY AT WOOD-FRAMING SHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. REFERENCE IBC 2012 SECTION 722.2.2 FOR CALCULATED FIRE RESISTANCE REFERENCE IBC 2012 SECTION 722.2.2 FOR CALCULATED FIRE RESISTANCE PT CONCRETE PODIUM, SEE STRUCTURAL DRAWINGS TRAFFIC COATING MEMBRANE ON ALL EXPOSED SURFACES. CONCRETE TOPPING SLAB, SEE STRUCTURAL DRAWINGS 1 2" RESILIENT CHANNEL @ 12" O.C. 5 8" TYPE 'C' EXTERIOR GRADE GYPSUM BOARD ATTIC OPEN WEB FLOOR TRUSS, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. TOP CHORDS TO SLOPE TOWARDS OUTSIDE EDGE OF BALCONY. TRAFFIC COATING MEMBRANE. MEMBRANE WATERPROOFING. 04/15/22