HomeMy WebLinkAboutA021 - FLOOR AND ROOF ASSEMBLIESARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
# DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM
UL DESIGN - UL L563 (1 HOUR)
STC RATING - 50 MIN
IIC RATING - 50 MIN
A021FLOOR AND ROOFASSEMBLIESAPSHALT SHINGLES
CEMENTITIOUS UNDERLAYMENT,
3/4" MIN.
1
8" SOUND MAT ONLY AT
AREAS THAT RECEIVE
VINYL PLANK FLOORING
SHEATHING, REF. STRUCTURAL
DWGS. FOR ADDITIONAL INFO.
18" OPEN WEB FLOOR TRUSS,
REF. STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
SOUND ATTENUNATION BATT
INSULATION (OMIT IN COMMON
CORRIDORS AND STAIR
LANDINGS AT F3a)
1
2" RESILIENT CHANNEL
@ 12" O.C.
5
8 " TYPE 'C' GYPSUM BOARD
WOOD SHEATHING PER
STRUCTURAL DWGS.
ONE LAYER 15# ROOF FELT.
EDGE METAL @ BOTTOM OF
SLOPED ROOF SHOULD BE
OVERLAPPED BY ROOFING
FELT. EDGE METAL @ GABLE
ENDS SHOULD OVERLAP
ROOFING FELT.
ROOF TRUSS PER
STRUCTURAL DWGS.
ONE LAYER OF 5
8"
TYPE 'C' GYPSUM BOARD
RESILIENT CHANNELS
@ 12" O.C.R-38 BLOWN-IN
FIBERGLASS INSULATION
SCALE:
FLOOR ASSEMBLY
F1
1 1/2" = 1'-0"
6 MIL UNDERSLAB
VAPOR RETARDER
COMPACTED SUB-GRADE,
SEE CIVIL DWGS.
CONCRETE SLAB PER
STRUCTURAL DWGS. &
STRUCTURAL SPECS
FOR FINISH INFO.
SCALE:
FLOOR ASSEMBLY
F3, F3a
1 1/2" = 1'-0"
SCALE:
ROOF ASSEMBLY
R1
1" = 1'-0"
USE: SLAB ON GRADE
USE: 1 HOUR RATED
TYPICAL UPPER FLOOR
USE: 1 HOUR RATED
PITCHED ROOF
SOUND ATTENUNATION
BATT INSULATION
1
2" RESILIENT CHANNEL @ 12" O.C.
2 LAYERS 5
8" TYPE 'C'
GYPSUM BOARD
SCALE:
FLOOR ASSEMBLY
F4
1 1/2" = 1'-0"
USE: 2 HOUR RATED
BETWEEN AMENITIES AND UNITS
SCALE:
ROOF ASSEMBLY
R3
1 1/2" = 1'-0"
60 MIL TPO ROOFING ADHERED/
FASTENED TO TAPERED INSULATION
PER MANUFACTURER'S REQUIREMENTS
TAPERED POLYISOCYANURATE
ROOF INSULATION TO ACHIEVE
POSITIVE DRAINAGE TO INTERNAL
ROOF DRAINS
ONE LAYER OF 5
8"
TYPE 'C' GYPSUM BOARD
RESILIENT CHANNELS
@ 12" O.C.
R-38 BLOWN-IN
FIBERGLASS INSULATION
WOOD SHEATHING PER
STRUCTURAL DWGS.
ROOF TRUSS PER
STRUCTURAL DWGS., TOP
OF TRUSSES SLOPED TO
ACHIEVE POSITIVE DRAINAGE
USE: 1 HOUR RATED
FLAT ROOF
5
8" TYPE 'C' GYPSUM BOARD
UL DESIGN - UL L577 (2 HOUR)
STC RATING - 5O MIN
IIC RATING - 50 MIN
UL DESIGN - UL P522 (1 HOUR)UL DESIGN - UL P522 (1 HOUR)
NOTE: SEE A030 SERIES FOR UL ASSEMBLY INFORMATION.
NOTE: WHERE CEMENTITIOUS UNDERLAYMENT ISN'T
POURED (UNDER TUBS/SHOWERS AND IN DEAD
AIR CAVITIES), PROVIDE 1/2" HOMASOTE BOARD
OR 15/32" MINIMUM OSB OR PLYWOOD OR 5/8"
GP DENSGLASS SHIELD FIRE GUARD TILE
BACKER TO MAINTAIN 1 HOUR FLOOR RATING.
SCHEDULED FINISH
CEMENTITIOUS UNDERLAYMENT,
3/4" MIN.
1
8" SOUND MAT ONLY AT
AREAS THAT RECEIVE
VINYL PLANK FLOORING
SHEATHING, REF. STRUCTURAL
DWGS. FOR ADDITIONAL INFO.
NOTE: WHERE CEMENTITIOUS UNDERLAYMENT ISN'T
POURED (UNDER TUBS/SHOWERS AND IN DEAD
AIR CAVITIES), PROVIDE 1/2" HOMASOTE BOARD
OR 15/32" MINIMUM OSB OR PLYWOOD OR 5/8"
GP DENSGLASS SHIELD FIRE GUARD TILE
BACKER TO MAINTAIN 1 HOUR FLOOR RATING.
SCHEDULED FINISH
SCALE:
ROOF ASSEMBLY
R4
1 1/2" = 1'-0"
USE: 1 HOUR RATED
ROOF OVER ELEVATOR SHAFT
UL DESIGN - GA-FC-5406 (1 HOUR)
TWO LAYERS OF 5
8"
TYPE 'C' GYPSUM BOARD
60 MIL TPO ROOFING
ADHERED/ FASTENED TO
TAPERED INSULATION
PER MANUFACTURER'S
REQUIREMENTS
POLYISOCYANURATE ROOF
INSULATION TO ACHIEVE R-20
R-VALUE, TAPER TO ACHIEVE
POSITIVE DRAINAGE
WOOD SHEATHING PER
STRUCTURAL DWGS.
2X WOOD FRAMING PER
STRUCTURAL DWGS
18" OPEN WEB FLOOR TRUSS,
REF. STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
ATTIC
ATTIC
USE: 3-HR RATED
CONCRETE PODIUM
SCHEDULED FINISH
SCALE:
FLOOR ASSEMBLY
F2, F2a
1 1/2" = 1'-0"
SCALE:
FLOOR ASSEMBLY
B1
1 1/2" = 1'-0"
WOOD SHEATHING PER
STRUCTURAL DWGS.
ONE LAYER 15# ROOF FELT.
EDGE METAL @ BOTTOM OF
SLOPED ROOF SHOULD BE
OVERLAPPED BY ROOFING
FELT. EDGE METAL @ GABLE
ENDS SHOULD OVERLAP
ROOFING FELT.
NOTE - ADD ONE LAYER 15#
ROOF FELT AT LOW-SLOPE
ROOFS. SEE SPECIFICATIONS
FOR MORE INFORMATION.
ROOF TRUSS PER
STRUCTURAL DWGS.
APSHALT SHINGLES
ONE LAYER OF 5
8" TYPE C
EXTERIOR GYPSUM BOARD
UL DESIGN - UL P522 (1 HOUR)
RESILIENT CHANNEL
@ 12" O.C.
SCALE:
ROOF ASSEMBLY
R2
1 1/2" = 1'-0"
USE: 1 HOUR RATED
TYPICAL BALCONY ROOF
USE: BALCONY AT
CONCRETE PODIUM
PT CONCRETE PODIUM,
SLOPE TOP OF CONCRETE TO
OUTSIDE FACE OF BALCONY,
SEE STRUCTURAL DRAWINGS.
SCALE:
FLOOR ASSEMBLY
B2
1 1/2" = 1'-0"
USE: DROPPED CEILING
BELOW PODIUM
SCALE:
CEILING ASSEMBLY
C1
1 1/2" = 1'-0"
SEE 'F2' ASSEMBLY FOR
ADDITIONAL INFORMATION
ONE LAYER OF 5
8"
TYPE 'C' GYPSUM BOARD
DRYWALL CEILING
SUSPENSION SYSTEM 1'-4"SPRAY ON OR RIGID INSULATION
TO ACHIEVE MIN. R-12.5 AT
GARAGE ONLY AT F2A.
USE: BALCONY AT
WOOD-FRAMING
SHEATHING, REF. STRUCTURAL
DWGS. FOR ADDITIONAL INFO.
REFERENCE IBC 2012 SECTION 722.2.2
FOR CALCULATED FIRE RESISTANCE
REFERENCE IBC 2012 SECTION 722.2.2
FOR CALCULATED FIRE RESISTANCE
PT CONCRETE PODIUM,
SEE STRUCTURAL
DRAWINGS
TRAFFIC COATING
MEMBRANE ON ALL
EXPOSED SURFACES.
CONCRETE TOPPING
SLAB, SEE STRUCTURAL
DRAWINGS
1
2" RESILIENT CHANNEL
@ 12" O.C.
5
8" TYPE 'C' EXTERIOR
GRADE GYPSUM BOARD
ATTIC
OPEN WEB FLOOR TRUSS,
REF. STRUCTURAL DWGS. FOR
ADDITIONAL INFO. TOP CHORDS
TO SLOPE TOWARDS OUTSIDE
EDGE OF BALCONY.
TRAFFIC COATING MEMBRANE.
MEMBRANE WATERPROOFING.
04/15/22