HomeMy WebLinkAboutA023 - WALL ASSEMBLIESWB1
(2) 2x6's AT TOP OF WALL
REF. STRUCTURAL DWGS. FOR
ADDITIONAL FRAMING INFO.
R-20 THERMAL BATT INSULATION
1 LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
5 1/2" REF. STRUCTURAL
UL DESIGNATION: U348
1-HOUR RATED
2x6 WD. BOTTOM PLATE
USE: EXTERIOR WALL WITH BRICK VENEER
UNIT
SIDE
INTERIOR 6" 11 1/2" MODULAR BRICK VENEER
AIR SPACE
GALVINIZED STEEL BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND HORIZONTALLY
REF. STRUCTURAL
(2) 2x6's AT TOP OF WALL
REF. STRUCTURAL DWGS. FOR
ADDITIONAL FRAMING INFO.
R-20 THERMAL BATT INSULATION
1 LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
FIBER CEMENT LAP SIDING
WFc1USE: EXTERIOR WALL WITH
FIBER CEMENT LAP SIDING
UNIT
SIDE
UNIT SIDE
UL DESIGNATION: U356
1-HOUR RATED 5 1/2" WFc2
WOOD ROOF TRUSS, SEE
STRUCTURAL DRAWINGS.
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
FIBER CEMENT VERTICAL PANEL
USE: EXTERIOR WALL WIDTH
CAVITY SIDE
EXTERIOR
CAVITY
SIDE
MB1
6" METAL STUDS
R-20 THERMAL BATT INSULATION
(1) LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
5 1/2" REF. STRUCTURAL
UL DESIGNATION: U348
1-HOUR RATED
USE: EXTERIOR WALL WITH BRICK VENEER
UNIT
SIDE
INTERIOR 6"11 1/2"MODULAR BRICK VENEER
AIR SPACE
GALVINIZED STEEL BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND HORIZONTALLY
WB3
USE: EXTERIOR CMU BLOCK WALL WITH
FURRING STRIPS 16" o.c. AND RIGID
INSULATION IN BETWEEN, LAP SIDING
NOMINAL 8" CMU WALL.
SEE STRUCTURAL DWGS
FOR GROUT & REINFORCING.
2" RIGID INSULATION
FIBER CEMENT LAP SIDING
2" x 2" WOOD FURRING STRIP
1'-4" 1'-4"7 5/8" 2 1/2"10 1/8"INTERIOR EXTERIOR
INTERIOR
(1) LAYER OF WEATHER
RESISTANT BARRIER
UL DESIGNATION: U905
2-HOUR RATED
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
MB2USE: EXTERIOR FOUNDATION GARAGE
WALL WITH BRICK VENEER 6" 6"1'-10"10" REF. STRUCTURAL
CONCRETE WALL: SEE
STRUCTURAL
6" METAL STUD
MODULAR BRICK
VENEER
AIR SPACE
MB3 USE: EXTERIOR WALL WITH BRICK VENEER
@ OFFICE
INTERIOR
GARAGE
SIDE
(1) LAYER OF WEATHER
RESISTANT BARRIER
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
GALVINIZED STEEL
BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND
HORIZONTALLY
6" 6"1'-6"6" REF. STRUCTURAL
INTERIOR
OFFICE
SIDE 6" METAL STUD
MODULAR BRICK
VENEER
AIR SPACE
(1) LAYER OF WEATHER
RESISTANT BARRIER
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
GALVINIZED STEEL
BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND
HORIZONTALLY
R-20 THERMAL BATT
INSULATION
(1) LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
MB4 6" 6"1'-5 1/2"5 1/2" REF. STRUCTURAL
INTERIOR
OFFICE
SIDE
MODULAR BRICK
VENEER
AIR SPACE
(1) LAYER OF WEATHER
RESISTANT BARRIER
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
GALVINIZED STEEL
BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND
HORIZONTALLY
R-20 THERMAL BATT
INSULATION
(1) LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
(2) 2x's AT TOP OF WALL
REF. STRUCTURAL DWGS.
FOR ADDITIONAL
FRAMING INFO.
USE: EXTERIOR WALL WITH BRICK VENEER
@ UNITS
NOMINAL 8" CMU WALL.
SEE STRUCTURAL DWGS
FOR GROUT & REINFORCING.
WB2 7 5/8" USE: CMU WALL WITH BRICK
VENEER AT STAIR
MODULAR BRICK VENEER
GALVINIZED STEEL BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND HORIZONTALLY.
INSTALL OVER SHEATHING &
ANCHOR BACK THROUGH FURRING
STRIPS
8" 1'-3 5/8" 2" RIGID INSULATION
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
AIR SPACE
6" METAL STUD
MB5 USE: EXTERIOR FOUNDATION GARAGE
WALL WITH BRICK VENEER 6"1'-4"10" CONCRETE WALL: SEE
STRUCTURAL
MODULAR BRICK
VENEER
AIR SPACE
INTERIOR
GARAGE
SIDE
GALVINIZED STEEL
BRICK TIES
INSTALLED AT 16" O.C.
VERTICALLY AND
HORIZONTALLY
(2) 2x6's AT TOP OF WALL
REF. STRUCTURAL DWGS. FOR
ADDITIONAL FRAMING INFO.
R-21 THERMAL BATT INSULATION
1 LAYER OF 5
8" TYPE 'X' GWB
(INTERIOR)
7
16" EXT. SHEATHING, REF
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
(1) LAYER OF WEATHER
RESISTANT BARRIER
REF. STRUCTURAL
WFc3
FIBER CEMENT VERTICAL PANEL,
SMOOTH FINISH, PRIMED AND
PAINTED ON SITE
USE: EXTERIOR WALL WITH
FIBER CEMENT VERTICAL PANEL
UNIT
SIDE
UNIT SIDE
UL DESIGNATION: U356
1-HOUR RATED 5 1/2" WALL ASSEMBLIESNOTE: SEE A030 SERIES FOR UL ASSEMBLY INFORMATION.
A023 ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
# DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM
1
100% CONSTRUCTION
DOCUMENTS 08-12-20
2 BID DOCUMENTS 01-15-21
2
04/15/22