HomeMy WebLinkAbout06010145-Misc.
CITY OF CARMEL / CLAY TOWNSHIP
IMPROVEMENT LOCATION PERMIT APPLICATION
For: Remodels & TcnQnt Finishes; Commercial, Indu5trial, or lnstitutional
Permit #: 06010145
Date: 02/21/2006
PARCEL 10 #: 1609250101006001
LOT & SUBDIVISION:
ADDRESS OF CONSTRUCTION: 840 MAIN ST W
Township?: 18 Zoning:
CARMEL, IN 46032
Flood Zone: N
Lot Split: N
PROPERTY OWNER INFORMATION:
Name: CONVENIENCE CENTERS LLC
Ph. #: 3178902462 Fax #: 3172845552
Street Address: 6910 N. SHADELAND #200 INDIANAPOLIS, IN 46220
TENANT INFORMATION:
Name: MICHAEL'S RESTAURANT
Address: 840 MAIN ST W CARMEL, IN 46032
CONTRACTOR INFORMATION:
Name: SKY CONSTRUCTION
Ph. #: (317) 890-2462 Fax #: (317) 284-5552 Email: EFARHOOD@THAPINVEST.COM
Street Address: 6910 N. SHADELAND #200 INDIANAPOLIS, IN 46220
Plumber's Name: BELL PLUMBING
Codes for Project: IPC
PERMIT TYPE: COMTENANT COMMERCIAL TENANT FINISH
Water Service by: CARMEL County Well Permit #:
Sewer Service by: CARMEL County Septic Permit #:
Foundation Type: SLAB Estimated Cost of Construction: $65000
Manufactured Trusses: N Sump Pump: N
Usage Class: COM Construction Type:
State Design Release #: 315683 Square Footage: 3600
SPECIAL CONDITIONS/NOTES:
MICHAEL'S RESTAURANT@ SILVER CONVENIENCE CENTER
N.E. CORNER MAIN & GUILFORD CONS1.TYPE: II-B.
OCCUP.CLASS: M, REM. S1.#: 315683. ARCH, ELEC,
MECH, PLUM. 20031BC. 3 CONDITIONS"SEE NOTEPAD.
HOOD ST. RELEASE & SPECS SUBMITTED ON
3/1/06. COPIES SENT TO CFD. Hold on
inspects will be cleared once CFD & J.
, ':Blanchard have looked aUapproved.
Changes approved by J.Blanchard 2/17/06.
Permit ready for issuance.
x G 1?,\~
~:
Small changes to plans submitted on
2/17/06. (3 pages) Per applicant, it
is not enough to require re-review at
State. This will be determined by J.
Blanchard and G.Hoyt as they review
changes.
3 State Release Conditions re:
1. Exit capacities
2. Egress doors and occupancy load
3. Hood suppression system plans/specs
need to be filed.
This permit is valid only if construction commences within one (1) year of the date of issuance of the State Commercial Design Release. All construction
must be completed (C/O issued) within two (2) years of the issuance date.
I, the undersigned, agree that any construction, reconstruction, enlargement, relocation, or alteration of a structure, or any change in the use of land or structures
requested by this application will comply with, and conform to, all applicable laws of the State of Indiana, and the "Zoning Ordinance of Carmel Indiana - 1993"
(Z~ 289) and amendments, adopted under authority of I.c. 36~7 et seq, General Assembly of the State of Indiana, and all Acts amendatory thereto. I funner certify
that only kitchen, bath, and Ooor drains are connected to the sanitary sewer. I further certify that the construction will not be used or occupied until a
Certificatt' of Occupal1cyhas been issued by the Department of Community Services, Carmel, Indiana.
FEES:
I APPLICANT NAME:
R. SHANE THARP
:---
FROM
BROWNS-FIRE
FAX NO.
2432500
Jun. 14 1998 10:B4AM P2
Would you like to reduce your turnaround time?
ELECTRON/CALLY FILE YOUR PROJECT WITIl STATE OF INDIANA AT
"-" . -- .__ _ .efile~.7@dh~.~n~~S"OU~B.~TwYM.i~'9OV/dh~ _ _ __,
,. -~~::';~" CONSTRUCTION DESIGN RELEASE ;~-;':"""_.J~~~~e/~'~.
.;.. . ~~l Stm. Fo"" 41191 (R~) i-io'n'.....<II...1ype --,oca.panCYda....-,.aUon
.~.~..~f.11f!7 RoportPrintedon,Februalyl.2006 EXST ._._~2. ._.._.
"'~ f-.s:cO-ofrelcll.
,'!!l16..Y _
Ind;.na '~:P'11menl oIllomelalld SeeuI1ty r~'NDJANA 021 HOOD
DrvlslDN OF FIRE SAFETY I PlAN REvIEW I F 0000 '
402 W. Washington st.. ROOm E245 I . S I Type of mleaae
IndIanapolis. IN 46204 I.{III' . : Standard
I...:.....- KOOSlfft ~!'f.n- :
A~~Lr;_Bmldl
SUPPORTIl~ERSAFETY
. To: Owner I Archltact I Engineer
Browns Fire Equipment
Gerald 13rown
7243 Westlake Rd
Ind.anapolis IN 46218
Projgct name
MichaeJ Fsmi1y RC$lal,lrant
Stl'8et IIddress
844 'II Main St
City !:Duntv
Carmel HAMILTON
I~~.~ e.~.jl; .!~.~2t32500, . ". . .. '. . . _.
TIle IIL'lnll. s09Cfficsfions and appl.i<:aUon $ubmitted for 1M above referenced project have been revMMed toT compbance W!YIlhe applicable .~,de;s or
thp. fire "'fOvfilntion and Building Sa'Qly ComfnlSsiOn:l"he pro)eCl i6 reJeeself(or conslnictiori sl,Ibjecfto. but not necCs:$arity limjte<fto,*~h. conditiotls.
li~led ~IOw. T-HIS-IS'NOT'A.Bt:JttDING'PERMJT:-AfI reqtired10cal permffs-and1toenses~ boo .A:a:.d....d Jft;"" (()'boginnin~ction wurk.AU
consJruC1iotl work mLlst be in fuR complianQe with aJl appli;eble StaIB rules. Any Chang=: In the released plans ancVor Specifications~musl be filed with
ana released by this Offioe betO/"8 anY1NO~i.lf~~.~~~= ~+..~. lor revoked if it iIi ~erm!.2.~ ~ed irt!entlf. in viofation
of any Mea ~fthe CommiS5ion Of it it is ~cm 1J..~~~m- W.!> ilJJ9Qxl . relaa5e shaJ/8kPire ~I~~~d ~.' e nun 8nd
vOitJ,iftheWOlil.avll1orizedfsnotcommen~[iodl~~ ~.it ~ ~,_ ~
CONDITIONS, _ .0" .= ""= '" '" = ~ .- ,
~~b,""::~~... ,
...,.... . ~ .'
.. .~. .:......,,~.
. ... .-~...~.. .......~:~.. '.: :.'.,f. :'::~::" ..~:~~":~~'!~~. ..:;;:_'_~~~';'~~'~.'.!'_ __,_'.~;~"'-f~-L._'._",_..
ii;:,;[{::, :,;"-. s>, 1;;) f:.;' .~~ ",i" .;0.; k '0 ,
In acCl)fdMCO with ~~~~~~~neral Admj~va ~ (675 1~1i-19) a C~fe~m of ~ .;Ii epeci~Jms thai c;onfonn
f?l(Sctly lo tho desigJJ~~~~e~ea'b)' Ute o~ lhe SlatEt~lding ~~ioner Sh~I~~Bintai~"8n ~ conslru~ jGbs;ta B5 weA as a
CO!)y cf the desig,~Z~~ft;;~~~;:/ ''- ~ ~ ~ :~ ! ~~ ~ ~~; .~
3M01 .. ~ l~~~(;;if HAS ~~E\ireWEO ~qgR THE.~oi INO ijeCHMtiPAL qOOE. (675
;': ~;l!~;!~l~';\~';'- ';.;::~ g 1,t ~ ~ .~ ~ ~
3M0507A i t~~pl~$installati~'ij)e e~~~ h~ ~h~u - = 'llI) ~~be in ~ccordance
. j'<;Mlht'Section 507, IMC'''{61'5 IAC.'is::t:'ll). fi'ifS"~E CllID . HE Hl;lOO FIRE
r,."., ;. SUPPRESION SYSTEMS r
Pllllase oe ad<;lsed th,f it an admin~~....of:U)jg....~.il.9~d., OiI~qetl;petitip~revicw must be filed at th9 above address wilh the
Fire Prcvunlion and Building Sufety ~&i~~~ittct.fq ~~~is ~t no later thiln eighteen (18) da~ hom lha above-
JJlatea cate, unlesa the tlighteenlh day ralrir,o'f8-SatDnfa'y. :a$Oi16ay. a.1dg;al hoiidsJ=unJot State ,taMe. or a day in which the Oe!,'Brtmeol of Fire
and Building Servk:e$Js.dOSed..ctUring..nocmal..tJu&j~..Jn..tbeJaUcJ....CaSe.lbe..fillng..deadlCRe.~be.u.e.Ji~~Q'r&:after. If you
cnQose to ,PCliUon, and the before-mentionea procedures are followed, your peUlion for review will be glllnted. and an administrative proceeding will
)C <=ond!JCled b,. an admlnislr.atilfO law jucfge of tho Fire Prevenlion and BuikJlng Safety Commission. If a petidon (or review is not fil8cl, thiS Order will
be tin;}l. !Jnd you mLlst comply with its reqwrgments.
t"ilcd By .. -'. I CodeRtYiewofflciaJ
!
rRED BENNETT
'---~---"
^ddreoi>,; (narne,tille of local offlcia1.6het,CiIy,etatc and ZIP code
DEPT Uf COMMUNITY SERVICE
JIM BLANCHARD
ONE CIVIC SQUARE
CARWEl. IN 46032
Fa" 1! O.f1:'.~ }1757124:99. jbJ8nchard@catrnel.in.~._.
Code nforcemenf & Plan ReVlow Branch -Director
Stale: Fire Marshal
~d/.S~
Vl?, OF
Page 1/1
FROM; BROWNS-FIRE
FAX NO. : 2432S00
Jun. 30 1998 05:30PM PI
,
BROWN'S FIRE EQUIPMENT
1243 West Westlake Road
Indianapolis, IN 46214
,.
'- ....,..,...,.-z.;o...... ..~.... , ,..,
.'......', ", "-' .
, ." ';1 ~. "j ;. ':~~-'r'-~':
EXHAUST FANS
-.
=:
I~~A~
i~~
~
~
,
r
,
f
J
r
I
I
!
t
{
~ ..
,
----..-..
,"'-..,.
,
m
ITEM HP CFM. SP VOLT PH
~ 3i
i ).;).> (
~~."
,i1jiJJ
~.~
.' '"JOB
ATE
CONTRACTOR
PO NO
SHIP TO
NO
SECTION
SPECIFICA liONS
.. B '-j
. \ '\ .....1-.
, _~l~~. \.l~ .. \,:
. \!
r
)c
./ A
l
I .
Aluminum upblast roof exhausters.
VentlIated sealed motor housing.
BearIngs include vibration Isolators.
A<lJustallle drIve and base plate,
r ''I"' "'-.
DIMENSIONS
4' S' AND 6' HOODS
.,
A- 19-3/8 B- 35-1/8 C= 28-13116
0= 10 G= 2 T sq.= 24 Wgt 72 lbs.
7' thru 12'
A= 22-7/8 B= 40-1/8 C= 32-1/2
0= 13 G= 2 T SQ.= 24 Wgt 98 lbs.
"'''IT-
-..J :!
~.""";'
D ..~~ ~ .__..__
T
-.....
,:"
fROM .BROWNS-FIRE
FAX NO. 2432500
Jun. 3B 1998 05: 31PM P2
I
I
!IF/OWN'S FIRE EQUIPMENT
);>43 West WesUake Road /
"'d,,'napolis, IN 46214 "
MODEL MUA
CODE 96 EXHAUST/MAKE.UP AIR HOOD
....--.-----
"-" ..---,
-,..--
-
----=
--
\
.\
).'1
I
/
-
.GB._..-...~iIlLE..[rn~..LY-._.fi.5'.J:Z_ DATE. JOB NO
SHIP TO "-'-'__'_'_ VIA
CONTRACTOR_ r(2.> :.vw.~ ~//l,.c c'''' ; ORDER NO
SIZE }'..(o L/ f " '. .
_H 'J"'/ X ,.S' BODY:OSTEEL9!ls/S Othroughout
FILTERS quan ~- type'-~L1GHTS quon. . type _
L OF'TIONS__. .H..__.______.., '_'___
r-.
;
STANDARD FEATURES
SECTION
14"
~~
!, ex ~J I
18"
I ' im~1
1. 81Xtf 18 gage stIlel with peinlW grey
exterior. Construction wntinous exterMI
welds to meet NFPA 96.
2. Grease filters galvanized.
3. Pitchell drip QUlII'd below filters.
.... S/S grease ClIlch pan with cover.
5. Insulated mua plenum.
OPTIONS
.,
;'"
48"
A. Incandescent light fixtures. Vapor proof or
code 96 (specifically V.L. listed for
mounting in greese hood).
8. S/S fronts, ends ood top filter frame or S1S
. throughol.Jt..
C. Collurs fectory installed.
D. Width 5'"
weight 35 pounds per lineal foot.
tJxhaust "'00 cfm/lineal fl. at 5/8" s.p.
mua 60 cfm lineal fool at 1/2" s.p.
erm may VIl1y With type of COOKing
---..........---.
......-.
.tROM : BROWNS-F IRE
- -~--'--
'"
..,
or
'1-
<>
on
<5
'b
"
..."
g~
=U) c;i
x:5~
"'t--
~ L.~
l.::.,:.- .
...
N
..
...
..
1::>
r:.
o
t-
'..
,;,
EXHAUst FIW
==-===:- ="-=--.-
\&'3>
FAX NO.
2432500
Jun. 30 1998 05: 31PM P3
10'.0" SEPARATION l
JlV- -.-.'
---_.
\ ----
FII.TERED NU~ FAN
~
ROOF' CURB
ROOf CIJR8
.".;!.
IIUA DUCT
FOR IO.-O~ EXHAUST TO MUA SEPAR'
MUA PI.ENUI<
" . '~~~WN'S fIRE EQUIPMENT
7243 West Westlal<. Road
Indianapolis, IN 46214
...:.:b..:!.,..j;.:~~..,~~ll...;,.~_...;.:~.4~,._...t.l",:",
8
8"
HOOD WJD11i" A '9 e. 6'" 4"
CDQ~G APPU~Nce
F;ROM : BROWNS-F IRE
. ..~=";':...l ",hi""; I .. -----:-..
"
J
Ii
a
I
I
.
..
..
,
II
..
.
It
..
*'
!
,
~
-.
FAX NO. 2432500
,
BROWN'S F,~t. EQUIPMENT
7243 West Westlake Road
Indianapolis, IN 46214
~
,
c:. "::. =-=:::::=:--~-.---~.
.- _.--~
, ~_..
i
!
I
\
.'
1
I JOB "'" , cc It At"").. "n /:tJ~!:::Y_-1kJ7
I SHIP TO iF"" IV ;;"#11/'01 ~T
EX A p.EI'L i~
H UST CFJVI ~,'N() DUCT SIZE
MUA CFM 3j~() DUCT SIZE
I' SPECIFICA liONS
EXHAUST DUCT
MaterIal.... 16 - gage ilIaCI< iron.
Construction continous external
welds at all seams.. Sections to be
field assembled will have weld
rI anges turned out 112" all sides.
Bottom edge of duct (hood connection)
IS a raw edge. Top of dUct (fan
,:onnection) is a raw edge. Duct length
uJ to 10'-0. will be one piece unless
,;:"herwise specHied. Pan for top of
.:.;rt> IS sQuare dimension of curb and
,,; )~s not Include hole for duct
: ;,nnection. Other accessories
::i3!iable include offsets, elbows,
:~\\Jr!;, Qralns ana clean out doors.
Jun. 30 1998 05:32PM P4
DUCTS
..J
-a--
-0/-
DATE_
VIA
: ,< t( ~
I '7'-y; IS- )( 9'
I. .,. !
;J,' 'r=~{_""': /}'-"7
NO__
SPECIFICA liONS
\
MAKE-UP AIR 0
Materi
for low essure duct. Slip and drive
construct i . of duct
furnished i suff' ient to provide
1 0' -0" sepera' 0
outlet and mua ake on roof unless
otherwise s cifi . Duct can be
internally ned wH n untempered
outside ai is used in ld climates.
Lining is 1/2" fiberglass ith fabric
I iner. Accessories include, turning' ".
vanes, volume dampers and fire"
dampers.
F.ROM BROWNS-FIRE
FAX NO.
2432500
,ge Guarlf)wet chemical fire suppression system.
l-. .'4,",_ I: ',_' .. , . "
C'~'
....
1", ~
~". oi.4~-'
; ..,~;.~~~::!.., ~
_'__ ""il. .....
., '~'''r~i: :~f!~. ;:~~~i>"'~;lf.r'~~';::<-I-!~'~~
. 'I ~!,~,..+~,::::::::=..: --.::i
Ii
.\1echanical Actuation
JS. Cartridge-Actuated
i ystems.
R.ll\f:e GUdJd offers important
rd\ ;:mli:!:ge8 in {he way it is
ul.iva,(ed.
" artridge Sysrems can
.Ie unreliable.
"m~ OIMr systems utilize a
";U'[ridge to activate the sys.-
'~'m. Thb lh<lY ~lrfSenl a major
I!L,blc:m: The caruidge can lose
'I rssure without witrning or
dcntificatiol1 and fail to operate
.'..hen a fire: ....'('fUrs.
rhe Range Guard system
i , Rt~liable
! :.1I11!.( c;uiln.l i:; mechanically
. ,:i i~'"u:d b~ ;1 ~pring loaded
':w('hanism which is uiggered
!.IV il ftl.;iblt" dement. When a
:i~l~t.Xcurs. thcelemenr melts
,.uld ~(;paralf:$ at 3600F -
i'~lusing the ~ys[em to activate.
:,(1 w\,.lIrying abolll: cartridges
. v~i"~ pres,;ure. The mecI1ani-
.,~ i1([ualor. properly installed,
\\"orks every time: - anti so
.Iors Range Guard!
TIUs Iota! reliability Is an iOlpor-
Will reason to insist 011 a genu-
inC Range Guard system.
Installation:
Straight Line vs.
Balanced Piping
Other SyStems require "bal-
anced piping." l1Us increases
the amount of pipe and fittin..~
needed for the sysr.em _ It takes
longer to Install. Labor and
marerial COSlS arc increased.
Balam:ed piping configurations
can al"" be cumberSOnte
and unsightly.
Range Guard utili2eS straight
line piping. This redu... <:cst
and installation time. Piping
configurations are designed for
maximum efliciency and are
aesrbetil:alIy pleasing.,
..
e-R --- .
I LC-=-~__>-' ~.
.i ----- I
/!.: ~~::~-~A~~El~:~ I'~r:f'-
l----~h~~~i- -~~/ l'
--- -~~:Qll1 =-(l)-,:-~~~=~:
..
IPJ \1'..
~ ; -:;::
. ..-- .' '.
.-A:_'.i
;f(.
~;-~.
. -;""""
~....fIC
1::.~:t;I~_!.
Choose from five Cy~nder
SiZes for SV<:fem Efficiency
and Flellibiliiy
Range Guard system cylinders
are available in 1-1/4 g;illon ro
6 g;illon sizes - witb a chok;"
of cylinder shapes In some SIZCS-
This provides ourmanding
desi!:n JlexjbiUl)l and allows
you to cusTOm design the
system which fi1s your
n..ds exactly.
A
........
.
Jun. 30 1998 05:32PM P5
_:, .! --, .- _.~ ._- --.
"The First
With The Best"
Range Guard. the first '""t
chL'II\icallire suppression sys-
tem. was developed OV'er 20
years ago. Toda)I it's still the
standard of the induslIy.. .
proven by performance.
I
o Si'stem Cylitldoc w1lh Mouot;,g Bt8cIc~
8 M_ Centro/Hold
. DIJtOC\OIl.irre~ ioCundtit
o Svoom lMd>a'!lO p;png
o IlI<t NoaIe
o ""',...NOllie
o ApoiMcc NOlI.
iii A""'1>MC Gas \'hoJl.ff
o RemomMallualIOo-
eEl EIl<t<i<Mao~IOO1i01>8lI
\I) li>id ScoI (ToMeo Ii> Hood & Oual
~atiI!ns .
It' Ccrnor [\Soy Inr o.ongc in (f,""",,",
(I) 0""'-'0( wi!h IiJslje Bement
~ROM 6ROWNS-FlRE
FAX NO.
2432500
Jun. 30 1998 05:33PM P6
The Wet Chemical System
RANCI CIlAAD@
1-27
o
o
"
- ;: TWO MICROSWlTCH
\. ..CONNECTOR ASSEMBLIES
- . '- (9197109)
1)--..........
It..:::.:;: ...~
r \
.
i
.-
/
,
,
.
,
'. I
--1
/"
!
'-,
"
a.E~,jUJoIC11'ON1IOIf
~1ft)....0THEJI8J
.......
DPDT MICROSWlTCH IN SET POSmON
Ag.'
.
,~.-
,
.-,,1
Connect the microswileh wiring connectors to
each of the microswitehes, Run the wires from the
winng connectors out through hole B EM;
cunnecticn. No wiring junctions are to be made in
the A+ eonlrol box.
Cominue the InstaftatioJl and selling of the A+ Control
Box per previous instruction. Be svre \0 remove' the
keeperpin as part of fhe installation and setting
procedure .
CAUTION: FAILURE TO REMOVE THE KEEPER
PIN WIL~ RESULT IN AN INOPERATIVE SYSTEM.
. An ~hts .-eaerved. (11194)
01988. 1900 Foggie Inle-''''''''" Inc., .
FROM : SROWNS-F I RE
..wl__... ----
RAKe! CU'AAD~
C-10
Detector
Detector
FAX NO.
2432S00
Jun. 30 1998 05:34PM P7
The Wet Chemical System
eROWifS FIRE EQUIPMENT, INC.
724-3 W. WE:st L~!\e RCrlo:l
lNDIAh:APOll$. INl):A~'I^ 46214
1317) 2~3.2500
'1 he (IotGCtorconsists of a plated steel bracket 11-3/4-1009,
a f l.I$ihl..t link, 2 cable crimps and 2 .9. Hooks to connect the
fusible link to 11'19 detection system cabte.
\'
,'2..tiMT
CONNl.C'tOR~ ~ LOCKNUT
(NOT $UPPLII::O)
. 1+-3" MIN
"--'C}f tr.:
-----."'',j . --~.
/-"---'k'=' :I" ..
/' .""''-''. .. /
CRIMP TYPE
~.. CABLE TO CABLE
ACTUATING DEViCE CONNECTOR
. 2";~
I
1--2'
~.
21~
l
11-314"
'\
FUSIBlE/
LINK
LOCKNUT"
"
::-:t.
"t
1/2" EMT
CONNECTOR
.j (NOT SUPPLIED)
- ~:::::!-
Zf.........-J
~ ...._..J ~
1/1." CABLE T~
ANOl"fiER oeT~CTOA
oR REMOTE
MANUAL CONTROL
CRIMP TYPE
CABLE
CONNECTOR
DETECTOR 97024
FIGURE 120
/
;
.
,
-_..-2~
\
r-
;.
;::
,
i.
/
Ratlllg
ParI
No.
Maximum
Ambient
Temperature
40:)'"
5000
57643
57644
GLASS BULB
(QUARTZOID) LINK
FIGURE 13c
375'F
47S'F
300' F maximum ambient temporalUre.
ASCOr3~ FUSIBLE LINK 969'03
~IGURE 14c
1 All ~iQftl!l1'9S8N9d. (1188)
989 F~iA '"lJiJfl\O'tianal. roC.
@1_.1 "'".- .
c....
".......
(
(
FfIDM
BROWNS-F I RE
FAX NO.
2432500
The Wet Chem;.,.,1 Fire Suppression System
Jun. 30 1998 05:34PM P8
IANCI CUAID.
2-11 Detectors
Detectors and Unks on this page lllIIIIllll be
used in conjunction with the A+ Control Be..
These detectors and links must be used with
the following COnlrol Head part numbe...:
8486607. 88l19063. 8899176. 8899175. and
8899082.
Fusible.LlIIIe Ilousi.ng Jrlt, PIN 804548
The fusible link housing Idt consists of a fuslbl.
link housing. two 1/2' EMT COIulectors. a supply of
""ble crimp sleeves and an 'S'hook to atw:h the
fUSlbl. link to lb. VI6" cable leading to the control
h~8d .
NOTE:
. un _:-:\
ACW'1P MAaCEr .....!MT
"EIIT~1 ""\ {
~ ~ ,F....1V--'~..
~ a -..._HEAD
..........l L.\ .,.....
~~ C5U1b'aEEW:
"".
-
,.::::.'."'''''''''
J 1lI!1E111E1 IIf'I'
~~~E
t.J-~~-""" ..........
Fusible Itnks are ava1lable In fouf temperature
raUngs~
Fusible
Linll
PIN Rating
8282661 165'F
E!?
1101..
Exposure
Temp.
Load Rating
10 Lb. Min. to 40 Lb. Max.
10 Lb. Min. to 40 Lb.IIax.
10 Lb. Min. to 40 Lb. 1Iax.
10 Lb. Min. 10 40 Lb. Max.
l00'F {38'Cl
150'F (6S'C]
3OO'F 1149'Cl
MO"F l226'Cl
There are two temperature deslgnatlunS wh.lch apply
to both fusible links and quartzold bulb IInk... One
temperature Is called the rating temperature and t.h('
other Is called the maximUM exposure tcmper.3ture.
The raUng temperature. which IS $tam~d on the
fuSible Unk. 15 the temperatun at which the Itnk will
sepaTate when new. However, contInual e}(pOS~rt to
cycl1ng ambtent temperatures may cause a degradation
of the Itnk over lime. Therefore. the fuSible links must
be replaced ~ISIInnualtv with a new link haVIng the
proper telnperatuT!!: rating,
The maximum exposure temp!!:rature 1$ the maxi-
)num ambient air temperature in which a fusible link
may be tns1a1Jed'. The maximum atr temperature at the
point of ltnk tnstallaUon must not exceed the maximum
exp.osure temperature shown tn the table.
Quaruold Bulb LlnIc. PIN 57643 rated at COlJ"F
{1Il04"l'} ancI ",N 87644 ruled ar SOOOF
(IIl_F)
The qU4Irbold bulb link Is uscd In con.tuncUon wllh
th~ fUSlbl(! Itnk hOUSing kit. The quartzotd bulb link
oonsl.ts of a glass bulb. RUed With liquid and a small
air bubble. and a metal housing. Temperature rise
expands the liquid In the bulb and compre5~s the all"
bubble. When a predetermined temperature Is reached.
th~ expanding liquid breaks lbe glass bulb and allows
the hOUSing pieces to separate. QuartzOld bulb Unk~
are aval1abl~ with a 4000F (204GC) and 5000F (260GCl
lemperatuTe rating. The maximum exposure tempera-
ture Cor the quartzold bulb link Is 37S'Y 1191'C) and
475"f' I 24B"CI respedlvely.
guartzold bulbs to be used on Range Guard .sys.
It:'m~ are UL LIsted and. designated I$$UC B. The loop
marked nAP should be Installp.d toward the control
bead, guar~old bulb links have: an unltmtted ~lfe
It.xpectaney. before operation. aJtd need not be changed
on a semiannual basts. However. the local authority
haVing Jurl8dtctlon may rule otherwise. On peTlodtc
tnspection. the quartzold bulb ltnk It'lu::;t be wiped
dean of "ease and dirt.
"
A
j.
Figure 2-16. QUlIr\Zold Bulb
2.11
Manua1 Part No. 9'\27'\00 (9197) Badg9r Fire ~.~ ~___
FROM ~NS-F[RE
".-' .
FAX NO.
2432500
Jun. 30 1998 05:35PM P9
The Wet Chemical System
RANGE GUARDO>
C-15
BROWN'S FIRE EQUIPMENT. INC.
7243 W. West Lake Road
INDIANAPOLIS. INDIANA 46214
(317) 243.2500
Mechanical Gas Valve
Moehonlea' Gas Valva
Tho valve has a spring. noTmally urging it into the closed
posilion. and a conlrol stem wdh which Iho valve may bo hold
open against the force of the spring,
Only mochanteal gas valves Ihat 8RI spocif~11y UL listed
and suppliod llY ASCOA may be used with Ih. Range Guard
",y~tom.
Mechanlca' gas valves are available in the following sizes:
Size Part Numbor
~och~n~1 gas va~os must be operated using ailher a
pneu.matlCroloaseord,l8elIyoffthe discharge leveronlho ma-
chan"",1 control box. There is no other method lor closing
mochanieal gas valves.
112"
314'
l'
).4'~
~
2.112"
3'
97011
97012
97013
97014
970'5
97016
97059
97060
o
.
~
GAS FLOW
--.... .
.
INLET
OUTLET
FIGURE 240
~1_. 19.. F;ggie 1""'""'l1on&1. ""', ,A" rightS .....,-. (118ll)
U.L EX 2458
F.ROM : BROWNS-F I RE
FAX NO.
2432500
Jun. 30 1998 05:35PM P10
The Wet Chemical System
RAtCI QIMD@
Cylinders
Si~CWN'S FIRE EQUIPMENT. INC.
7243 W, West lake Road
INDIANAPOLIS, INOIANA 46214
(317) 243-2500
C-1
Cyfinders
, flange Guardsystems have ayallablefive diffe....t cylinder
sIZes; 5 Quan. 2.112 gallon, 4 gallon long. 4 ganon short and
6 gallon, The cyfinder size is expressed in terms of the
Kerba~capacity. Each cylinder is pressurized w~h n~rogen
or air to 176 poig. at 70" F.
Note: n is recommended that cylinders be stored upright,
. Table 10
Charged Height to " r Overall Heigllt W"lth (lye,.U Height
Cylin..... P"" Weight' Diameter of Discharge Pon Mech Actuator" With P......matic
Size No. (lbs) (Inches) (Inches) (Inches) ConUOl Heed
(Inches)
SQuart 97422 28.5 7-1/2 16 17 28-1/4 18-3/4
.--~ 53' .._w. '-"~-'
2.112 Gallon 97250 9 21-318 22-318 33-618 24-118
".-."- -.. ...-'" .-'---- ____0"
4 Callon.S 97157 80 12 19-1/4 20-114 31.1/2 22
4 Gallon-L ---- 48 38-1/2
96823 88 8-1/4 35-314 36-314
--- .-.--.-- -.----
6 Gallon 96776 110 to-3116 35.118 36-1/8 47-318 37-7/8
4 GAllON
(TALL)
6 GALLON
2-'12
GAllON
'.114
GALLON
. MclDured with eover funy open to allow nonnel ._"ing of the system. .
_~__ .abI'l Hftaio 'ntamPGnaI. lnc.. ,AD rights IQS6tvad (11I9A)
FROM
BROWNS-FIRE
FAX NO.
2432500
Jun. 30 1998 05:36PM
P11
RANClGUMD
C-l1
The Wet Chemical System
Surface Mounted Remote Manual Controls
r-'"l
i i
~-......
"
Surface Mounted; The surface mounted remote manual
control (PIN 97027) prQvides a means to operate the system
1TI.1nuaUy from a r@Omote location. It is operated by removing a
Dull pin.
Two types of surface mounted remOTe manual controls are
available. Toe End.of-Line Remote Manual Control (PIN
97463) is designed for uSe atlM. end of to. detection line (see
tigure 15c). A FFPS approved tee pulley is included witM IMe
In-line K~ (97464) and woen coupled with tMe Remote Manual
Control (97~ the resultant is an in. line configuration. (see
fi9ure 16c).
The remote manual control can be installed in either the
vertical.up (from the floor up) or the vel1ical-down position
(from the ceiling down). An optional inve"ed cover plate
(PiN 97448) is allllilable lor v~ical-up installations.
CAUTION: Tt:E PVUEYS CAN NOT BE USED TO
oPERATE DUEL GAS VALVES.
r""
i i
+..~
: : ; :-----,IT e_ CDllIIKTORS
,tr nn CDNJrECTORs
..........-
1..- ROlL PIN
......
,"'- CASU;
COAICEA PUU..!:y
lIIURlttC
LEAD SUI. & WIRE
~-
""V" 8RAOlET
OUT\,ET ....
.,.,..............
-...ofIE COlllInDl
Flemote Menual Controls
ClOVER
o
IN CASE
Of fnlE
PUlL PI"
,,,r eMU:
Cl.ANP m.0Ctl
LEAD &eM. . WI.
4-
....L ...
."...........
o
......
(END-OF-lINE 97463)
FIGURE 15c
F
.tr dOT co....... ]
Irta-eADt..F.
TO DETECTORS
'ft"" an COMDun
112"" EVr CONNEC:TOR
fI~MANlIALCOIn'ItO..
....,
'''-IWU..PIN
. 0
co_eel puu.,.
BEARJNG
'''''7
~~;::.'
~mECONRGURAno~
AGURE 16c
... .....f.... ~_~.__OI ,.'.tnA\