Loading...
HomeMy WebLinkAboutA114 - BUILDING PLANS - BUILDING AA211 2 A212 1 A2122 A211 1 8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12"8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12"8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"3" / 12"8" / 12" 2" / 12"2" / 12"A211 2 A212 1 GENERAL NOTES 1. SEE ID SERIES FOR FINISHES, APPLIANCES, MILLWORK, PLUMBING FIXTURES & HARDWARE. 2. ALL UNITS IN THIS SET ARE DESIGNED AS A117.1 ANSI TYPE B UNITS AND ARE TO COMPLY WITH ACCESSIBILITY CODES LISTED ON THE COVER SHEET. ADDITIONAL ACCESSIBILITY IS TO BE PROVIDED AT IDD UNITS. SEE PROJECT COMMITMENTS SHEETS FOR REQUIREMENTS AND PLANS FOR UNIT LOCATIONS. 3. ALL BEDROOM CLOSETS TO HAVE DOUBLE WOOD SHELF AND ROD CONFIGURATION UNLESS NOTED OTHERWISE. 4. ALL COAT CLOSETS TO HAVE SINGLE WOOD SHELF AND ROD CONFIGURATION. 5. ALL LAUNDRY ROOMS TO HAVE SINGLE WOOD SHELF CONFIGURATION, SHELF TO BE INSTALLED AT 5'-0" A.F.F. UNLESS NOTED OTHERWISE. 6. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS. 7. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC UNIT, BATHTUB DOORS AND WINDOWS. 8. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT. 9. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1". 10. WRAP ALL EXPOSED PIPES WHERE REMOVABLE CABINETS ARE PROVIDED. 11. BASE OF MIRROR REFLECTED SURFACE TO BE INSTALLED 40" AFF MAXIMUM. 12. PROVIDE ELECTRICAL OUTLET IN KITCHEN ISLAND SIDEWALL 6" BELOW COUNTERTOP AT CENTERLINE OF WALL. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 13. ALL CEILING HEIGHTS IN UNITS ARE 9'-0" A.F.F. 14. REFER TO SHEET A311 FOR DEMISING WALL AND CORRIDOR WALL REQUIREMENTS. 15. ALL WALLS BEHIND PLUMBING FIXTURES TO BE 2X6 MINIMUM. 16. ALL SLOPED CONCRETE SURFACES ARE TO RECEIVE BROOM FINISH. 17. ALL OPENINGS THROUGH DRAFTSTOP IN ATTIC SHALL BE EQUIPPED WITH SELF CLOSING/LATCHING HARDWARE. 18. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE PROTECTED AS PER APPLICABLE UL SYSTEM LISTING.ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID DOCUMENTS A114BUILDING PLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE 1 BID DOCUMENTS 01-15-21 SCALE: 3/32" = 1'-0"1 BUILDING A ROOF PLAN -OVERALL 1 04/15/22