HomeMy WebLinkAboutE000 - SYMBOLS AND ABBREVIATIONSNOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTG xxAFyyAT xxAFyyAT xxAFyyAT xxAFyyAT xxAFyyAT zzA CT zzA zzA zzA K2 ST 1 (3) (3) 400-5A VFD CAPACITOR CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE RATING CONTACT NORMALLY OPEN (NO) ("TC"-WITH TIMED CLOSING) CONTACT NORMALLY CLOSED (NC) ("TO"-WITH TIMED OPENING) CURRENT TRANSFORMER CABINET FUSED CUTOUTS, "zzA" INDICATES FUSE RATING DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH AIR BREAK WITH FUSE,"zzA" INDICATES FUSED RATING FUSE, "zzA" INDICATES FUSED RATING OVERLOAD RELAY GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT KIRK KEY INTERLOCK SYSTEM LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL PHASES NAME VOLTS AMPS MAINS POTHEAD STRESS CONE RESISTOR SHUNT TRIP MAGNETIC STARTER WITH NEMA SIZE INDICATED GROUND FAULT CIRCUIT INTERRUPTER, PERSONNEL PROTECTION GENERATOR TRANSFORMER, DRY TYPE, UNLESS OTHERWISE INDICATED POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY CURRENT TRANSFORMER, "3" INDICATES QUANTITY, "400-5A" INDICATED RATIO 3-PHASE, 3-WIRE DELTA CONNECTION CORNER GROUNDED DELTA 3-PHASE, 4-WIRE WYE CONNECTION (GROUNDED NEUTRAL) VARIABLE FREQUENCY DRIVE AUTOMATIC/MANUAL TRANSFER SWITCH, 4-POLE UON ONE-LINE IDENTITY SYMBOLS PANELBOARD NAME KVA PRI: SEC: D Y MOTOR, "#" DESIGNATES HORSEPOWER# GFCI SPD SURGE PROTECTION DEVICE GENERAL NOTES A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE -LATEST EDITION ADOPTED BY STATE HAVING JURISDICTION, AND THE STATE HAVING JURISDICTION ELECTRICAL CODE AMENDMENTS, LOCAL/MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL AND SHALL MATCH FIRE RATING OF BARRIER BEING PENETRATED. D. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS UNLESS NOTED OTHERWISE. E. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. F. REFER TO ONE-LINE DIAGRAM FOR ALL FEEDER SIZES. G. WHEN CABLE TRAY IS SHOWN ON THE PLANS AND PORTIONS OF CABLE TRAY CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY. H. FEEDERS SHALL NOT BE COMBINED IN A RACEWAY. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. WHERE CIRCUITS ARE COMBINED CONDUCTORS MUST BE DERATED ACCORDING TO NEC. I. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. J. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK-SEALS. K. SUPPORT ALL CABLES AND RACEWAYS ACCORDING TO NEC. L. CONTRACTOR TO PROVIDE AND UPDATED TYPE WRITTEN PANEL INDEX UPON COMPLETION OF PROJECT. M. OCCUPANCY SENSORS LOCATED WITHIN THE SAME ROOM/SPACE SHALL WORK IN TANDEM UNLESS NOTED OTHERWISE. N. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR INCORRECT WORK, OR FOR INFRINGMENT UPON OTHERS WORK, DUE TO A LACK OF COORDINATION. O. COORDINATE LOCATION OF ALL DEVICES TO BE INSTALLED IN CEILINGS (LIGHTS, SPEAKERS, DETECTORS, ETC.) WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. NOTIFY ENGINEER OF AN CONFLICTS PRIOR TO INSTALLATION. P. DEVICES IN GENERAL SHALL BE CENTERED IN WALL SPACE IN WHICH THEY ARE INSTALLED OR THEY SHALL BE SPACED SYMMETRICALLY (FOR EXAMPLE, CENTER DEVICES WHEN MOUNTED ON FACE OF COLUMNS). Q. WIRING SHALL BE MINIMUM #12AWG UNLESS NOTED OTHERWISE. R. CONDUIT SHALL BE MINIMUM 3/4" UNLESS NOTED OTHERWISE. S. LISTED SHORT CIRCUIT RATING ARE ESTIMATED FINAL RATINGS SHALL BE DETERMINED BY SHORT CIRCUIT ANALYSIS BASED ON AVAILABLE FAULT CURRENT FROM UTILITY. T. COORDINATE AND VERIFY LOCATIONS OF DEVICES WITH BLOCK COURSING, FINISH MATERIALS, CASEWORK, ETC. PRIOR TO ROUGH-IN. U. WIRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE A MINIMUM #10 AWG UNLESS NOTED OTHERWISE. V. ALL RECEPTACLES CONNECTED TO EMERGENCY CIRCUITS SHALL BE RED IN COLOR UNLESS NOTED OTHERWISE. W. COORDINATE LOCATION OF RECEPTACLES AT ELECTRIC WATER COOLERS (EWC) WITH EWC MANUFACTURER. PROVIDE DUPLEX RECEPTACLE SO THAT IT IS CONCEALED BY EWC HOUSING. X. ALL DEVICE BOXES SHALL BE FLUSH MOUNTED AND ALL RACEWAYS SHALL BE CONCEALED UNLESS NOTED OTHERWISE. CONTRACTOR SHALL CUT AND PATCH EXISTING WALLS WITH EXTREME CAUTION, SO AS TO MINIMIZE INVASIVNESS OF INSTALLATION. ROUTE RACEWAYS SO AS TO MINIMIZE THE AMOUNT OF CUTTING AND PATCHING REQUIRE. PATCHING SHALL COMPLY WITH ALL BID DOCUMENT REQUIREMENTS. Y. EXISTING CONCEALED RACEWAYS AND DEVICE BOXES MAY BE REUSED IN PLACE IF DEEMED CODE COMPLIANT AND IN GOOD CONDITION. CONTRATOR IS RESPONSIBLE FOR VERIFICATION. Z. PROVIDE 120V POWER CONNECTION TO ALL MOTORIZED DAMPERS AT EXHAUST FANS. AA. EMERGENCY EGRESS LIGHTING IS ACCURATE TO BASIS OF DESIGN FIXTURES. ALL OTHER APPROVED EQUALS ARE RESPONSIBLE TO PROVIDE ADDITIONAL QUANTITIES AS NEEDED TO ACHIEVE CODE REQUIREMENTS. BB. FACP SHALL COMMUNICATE USING A DACT CONFIGURATION UNLESS NOTED OTHERWISE. DACT CONFIGURATION SHALL COMPLY WITH ALL NFPA REQUIREMENTS AND SPECIFICALLY BUT NOT LIMITED TO NFPA 72 SECTION 26.6.4.1 FOR APPROPRIATE DACT CONFIGURATION. DEMOLITION EXISTING NEW WORK LINETYPE DESIGNATIONS & AND EMT ELECTRICAL METALLIC TUBING OCP OVERCURRENT PROTECTION Ø PHASE ETR EXISTING TO REMAIN OD OUTSIDE DIAMETER, OVERFLOW DRAIN °F DEGREES FAHRENHEIT EWC ELECTRIC WATER COOLER OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED A/C AIR CONDITIONING EX EXISTING OL OVERLOAD A AMPERES FCU FAN COIL UNIT OZ OUNCE ACCU AIR COOLED CONDENSING UNIT FLR FLOOR P POLE, PHASE, PARALLEL AF AMPERE FUSE FP FIRE PUMP PE PNEUMATIC ELECTRIC AFC ABOVE FINISHED COUNTER FPVAV FAN POWERED VAV UNIT PF POWER FACTOR AFF ABOVE FINISHED FLOOR FT FOOT, FEET PH PHASE AFG ABOVE FINISHED GRADE FURN FURNACE PTAC PACKAGED TERMINAL AIR CONDITIONER AHU AIR HANDLING UNIT G GROUND, GALLONS PVC POLYVINYL CHLORIDE CONDUIT/PIPE AIC AMPERES INTERRUPTING CAPACITY GC GENERAL CONTRACTOR RCPT RECEPTACLE AL ALUMINUM GFI GROUND FAULT INTERRUPTING REV REVOLUTIONS ANSI AMERICAN NATIONAL STANDARDS INSTITUTE GFCI GROUND FAULT CIRCUIT RGS RIGID GALVANIZED CONDUIT ARCH ARCHITECT GRD GROUND RM ROOM ATS AUTOMATIC TRANSFER SWITCH GND GROUND RPM REVOLUTIONS PER MINUTE AVG AVERAGE HHWP HEATING HOT WATER PUMP RPS REVOLUTIONS PER SECOND BAS BUILDING AUTOMATION SYSTEM HOA HAND-OFF-AUTOMATIC RTU ROOF TOP UNIT B/I BYPASS ISOLATION HORIZ HORIZONTAL SF SQUARE FOOT BE BOTTOM ELEVATION HP HORSEPOWER SPEC SPECIFICATION BLDG BUILDING HR HOUR(S) SQ SQUARE BMS BUILDING MANAGEMENT SYSTEM HRTU HEATING ONLY ROOFTOP UNIT ST SHUNT TRIP BSMT BASEMENT Hz HERTZ STD STANDARD C CONDUIT IAC INSTRUMENTATIONS AND CONTROLS SW SWITCH CB CIRCUIT BREAKER ID INSIDE DIAMETER TBD TO BE DETERMINED CBA COLOR BY ARCHITECT IN INCH, INCHES TBI TO BE INSTALLED CCW COUNTERCLOCKWISE INT INTERIOR TBR TO BE REMOVED CH CHILLER JP JOCKEY PUMP TC TEMPERATURE CONTROLS CHWP CHILLED WATER PUMP K KELVIN, KEYED TCC TEMPERATURE CONTROLS CONTRACTOR CLG CEILING kW KILOWATT TR TAMPER RESISTANT CMT CONDUIT EMPTY KVA KILOVOLT AMPS TEMP TEMPERATURE COMPR COMPRESSOR LBS POUNDS TF TRANSFER FAN COND CONDENSER LSI, LSIG TRIP TYPE -LONG, SHORT, INSTANTANEOUS, GROUND FAULT TRANS TRANSITION CONV CONVECTOR LTG LIGHTING TYP TYPICAL CT COOLING TOWER MAX MAXIMUM UH UNIT HEATER CU CONDENSING UNIT, COPPER MC MECHANICAL CONTRACTOR UON/UNO UNLESS OTHERWISE NOTED CUH CABINET UNIT HEATER MCA MINIMUM CIRCUIT AMPS UV UNIT VENTILATOR CUV CLASSROOM UNIT VENTILATOR MCC MOTOR CONTROL CENTER V VOLTS CW CLOCKWISE MFR MANUFACTURER VAV VARIABLE AIR VOLUME CWP CONDENSER WATER PUMP MIN MINIMUM VB VACUUM BREAKER D DEDICATED CIRCUIT MISC MISCELLANEOUS VERT VERTICAL DC DIRECT CURRENT MOP MAXIMUM OVERCURRENT PROTECTION VF VENTILATION FAN DS DISCONNECT SWITCH MTD MOUNTED VFD VARIABLE FREQUENCY DRIVE DWH DOMESTIC WATER HEATER MV MEDIUM VOLTAGE W WIRE, WATT DWG DRAWING NA NOT APPLICABLE WP WEATHERPROOF EA EACH NEC NATIONAL ELECTRIC CODE W/ WITH EC ELECTRICAL CONTRACTOR NIC NOT IN CONTRACT W/O WITHOUT EF EXHAUST FAN NL NIGHT LIGHT WSHP WATER SOURCE HEAT PUMP EFF EFFICIENCY NOM NOMINAL EL ELEVATION NTS NOT TO SCALE ABBREVIATIONS AND TERMS T CT BRANCH PANEL, RECESSED BRANCH PANEL, SURFACE DISTRIBUTION PANEL MOTOR CONTROL CENTER (MCC) TRANSFORMER CURRENT TRANSFORMER CABINET DISTRIBUTION IDENTITY SYMBOLS METER GROUNDING ELECTRODE BUS BAR SWITCHGEAR SECTION CR DH H F S D RTS CONTROL RELAY DOOR HOLDER WITH RELAY HORN AND STROBE HORN UNIT ONLY STROBE UNIT ONLY EMERGENCY ADDRESS SPEAKER AND STROBE MANUAL PULL STATION SMOKE DETECTOR DUCT SMOKE DETECTOR W/ AUX CONTACTS REMOTE STATION FOR DUCT DETECTOR USED AT DUCT WORK OPENING FIRE ALARM IDENTITY SYMBOLS S E F CLNG. WALL CLNG. WALL CLNG. WALL F S E S E ELEVATOR RECALL WITH AUXILIARY CONTACTS B R B S C F H BEAM SMOKE DETECTOR, "R" = RECEIVER BEAM SMOKE DETECTOR, "S" = SENDING UNIT CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH BATTERY BACKUP FLAME DETECTOR HEAT DETECTOR H 2 HYDROGEN DETECTOR FS FLOW SWITCH TS PIV TAMPER SWITCH POST INDICATOR VALVE NURSE CALL SYMBOLS REMOTE ENTERTAINMENT STATION NM VOIP NURSE CONSOLE STAFF STATION PULL CORD STATION CANCEL STATION STAFF ASSIST CODE BLUE STATION FIRE/AUXILARY MODULE CALL BUTTON TV WALL PLATE CORRIDOR 4-POSITION LIGHT SS PC CC CS IM PH TV D RE C SINGLE CONVENIENCE RECEPTACLE DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL MOUNT DEVICE DOUBLE DUPLEX CONVENIENCE RECEPTACLE. DUPLEX RECEPTACLE. 20A 125V. HORIZONTAL WALL MOUNT DEVICE. SPECIAL RECEPTACLE CLOCK HANGER OUTLET RECESSED MOUNTED 8'-0" AFF OR 8" BELOW CEILING AS INDICATED POWER IDENTITY SYMBOLS GFCI DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL MOUNT DEVICE GFCI DOUBLE DUPLEX CONVENIENCE RECEPTACLE. SLASH INDCIATED DEVICE TO BE INSTALLED ABOVE COUNTER OR COUNTER BACKSPLASH J FLOOR DUPLEX CONVENIENCE RECEPTACLE, SEE NOTES FLUSH MOUNT FLOOR BOX, WITH BOTH POWER AND VOICE/DATA RECEPTACLES, SEE NOTES CEILING MOUNTED RECEPTACLE MOTOR PUSH-BUTTON ON/OFF PUSH-BUTTON STATION THREE FUNCTION PUSH-BUTTON SWITCH (UP/DOWN/STOP) S TOGGLE DISCONNECT SWITCH DISCONNECT SWITCH CB C ENCLOSED CIRCUIT BREAKER MAGNETIC CONTACTOR MAGNETIC MOTOR STARTER COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH PHASE GENERIC HARDWIRED ELECTRICAL CONNECTION 3/4"x10' COPPER GROUND ROD NEUTRAL GROUND HOMERUN SURFACE MOUNTED 2'x4' FIXTURE SURFACE MOUNTED 2'x4' EMERGENCY FIXTURE RECESSED MOUNTED 2'x4' FIXTURE RECESSED MOUNTED 2'x4' EMERGENCY FIXTURE SURFACE MOUNTED 1'x4' FIXTURE SURFACE MOUNTED 1'x4' EMERGENCY FIXTURE RECESSED MOUNTED 1'x4' FIXTURE RECESSED MOUNTED 1'x4' EMERGENCY FIXTURE SURFACE MOUNTED FIXTURE SURFACE MOUNTED EMERGENCY FIXTURE RECESSED MOUNTED FIXTURE RECESSED MOUNTED EMERGENCY FIXTURE LIGHTING IDENTITY SYMBOLS SUSPENDED FIXTURE SUSPENDED EMERGENCY FIXTURE WALL MOUNTED FIXTURE WALL MOUNTED EMERGENCY FIXTURE WALL MOUNTED FIXTURE WALL MOUNTED EMERGENCY FIXTURE EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS INDICATED ON DWGS (MOUNTING HEIGHTS TO BE DETERMINED BY JOB SPECIFICATION EMERGENCY BATTERY UNIT WITH LIGHTING HEADS EMERGENCY BATTERY REMOTE LIGHTING HEADS LIGHT TRACK, LENGTH AS INDICATED ON DWGS WITH NUMBER OF HEARDS INDICATED ON DWGS IN-GROUND OR FLOOR MOUNTED FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE TWIN LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE ROADWAY LUMINAIRE-COBRA HEAD BOLLARD TYPE SITE LIGHTING FIXTURE LIGHTING FIXTURE LEGEND: "A1" -DESIGNATES UNIT ID, REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. "a" - DESIGNATES SWITCH LEG "NL" -DESIGNATES NIGHT LIGHT, FIXTURE TO BE CONNECTED AHEAD OF CONTROLS "A1" "a" "NL" SINGLE POLE SWITCH "a" INDICATES SWITCH LEG SWITCH 3-WAY SWITCH 4-WAY SINGLE POLE/DOUBLE THROW SWITCH PILOT SWITCH TOGGLE SWITCH IDENTITY SYMBOLS 4 DT PS S S 3S aS S KEY OPERATED SWITCHKS MOMENTARY CONTACT SWITCHMCS D M DIGITAL TIMER SWITCH WEATHERPROOF SINGLE POLE SWITCH DIMMER SWITCH DUAL TECHNOLOGY OCCUPANCY SENSOR, WALL MOUNTED WITH OFF-AUTO OVERRIDE SWITCH DUAL TECHNOLOGY OCCUPANCY SENSOR, CEILING MOUNTEDM T WP S S DATA OUTLET DATA OUTLET FLOOR TYPE ROUGH-IN IDENTITY SYMBOLS VIDEO SURVEILLANCE CAMERA ROUGH-IN LOCATION DOORBELL/BUZZER/DOOR CHIME ELECTRIC DOOR STRIKE REQUEST TO EXITRX ES CARD READERCR SECURITY DOOR CONTACTSDC SECURITY KEYPADK SECURITY KEYPAD FIRE ALARM COMM IDENTITY SYMBOLS FIRE FIGHTER'S PHONE FACP FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL NAC BATTERY PACK AND CHARGER IAM ZAM INDIVIDUALLY ADDRESSABLE MODULE-MONITOR (PROVIDES ADDRESS FOR CONTACT) INDIVIDUALLY ADDRESSABLE MODULE-RELAY (PROVIDES CONTACT CLOSURE) FAA SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. REFERENCE SYMBOLS DRAWING BLOCK TITLE SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET KEYNOTE INDICATORS AREA LEADER LINE LEADER POINT LEADER DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) REVISION CLOUD REVISION INDICATOR NUMERIC SCALE SEE P-102 REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN PLAN NUMERIC CHARACTER RELATES TO ITEM NORTH ARROW BEYOND AREA EXTENSION SCALE: 1/8" = 1'-0" X XX X X X X X X X X N CLNG. WALL S JUNCTION BOX DROP CORD/CORD REELD VFD VARIABLE FREQUENCY DRIVE FLUSH MOUNT FIRE RATED POKE-THRU,WITH BOTH POWER AND VOICE/DATA RECEPTACLES, SEE NOTES ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET E000SYMBOLS ANDABBREVIATIONSNORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE 07/08/21