HomeMy WebLinkAboutLS112b - BUILDING A - UPPER FLOOR CODE PLAN - AREA BCODE PLAN GRAPHICS LEGEND 1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR EACH AREA OF SEPARATION AS INDICATED. 2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW. PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING ON BOTH SIDES. 3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1-HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 4. CORRIDOR WALLS TO BE 1-HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A160 SERIES. 6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A340 SERIES. 7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. 8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND ROOF/CEILING SPACES PER SECTION 718. 9. 20"X30" MIN. ATTIC ACCESS PANEL. 10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH DRAFSTOPPING. CODE PLAN NOTES # NON-RATED ASSEMBLY 1 HR RATED ASSEMBLY 2 HR RATED ASSEMBLY 2 HR FIRE WALL DRAFT STOP LOCATION FIRE EXSTINGUISHER CABINET DIRECTION OF TRAVEL 31 0 0"EXIT OCCUPANT LOAD THROUGH EXIT EGRESS WIDTH ALLOWABLE NUMBER OF OCCUPANTS THROUGH EXIT LOAD FACTOR KEY R - RESIDENTIAL - 200 GROSS B - BUSINESS - 100 GROSS S - STORAGE - 300 GROSS STAIR WIDTH = X DOOR WIDTH = X xxx STAIR WIDTH FACTOR 0.20" PER OCCUPANT DOOR WIDTH FACTOR 0.15" PER OCCUPANT EGRESS CAPACITY OF STAIR R-2 210SF ROOM # 1202 1 OCCUPANCY GROUP ROOM IDENTIFICATION ROOM AREA NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS FEC 2-HR FW A - ASSEMBLY - 15 GROSS E - EXERCISE - 50 GROSS U - GARAGE - 200 GROSS 2-HR FW2-HR FW 2-HR FW1 / LS112a 1 / LS112a UNIT B2 226 1202SF 200 R2 16 UNIT B2 227 1202SF 200 R2 16 UNIT B3b 224 1276SF 200 R2 1 7 UNIT A1 IDD 222 831SF 200 R2 1 5 UNIT A1 IDD 220 831SF 200 R2 1 5 UNIT A2 218 828SF 200 R2 15 UNIT A2 IDD 225 828SF 200 R2 15 UNIT A1 IDD 223 831SF 200 R2 15 UNIT A1 IDD 219 831SF 200 R2 15 UNIT A2 221 828SF 200 R2 15 DOOR WIDTH = 34" 120 STAIR WIDTH = 36" 27 227 34" 27 F.E.C.(54) TOTAL OCCUPANCYF.E.C. F.E.C. F.E.C. 9 9 9 4 3 TYP. 5 5 103SF 1 S-2 STORAGE S202 300 1 AREA A AREA B FIRE AREA DIAGRAM - BUILDING A GARAGE - TYPE IA CODE BLDG SECTION BUILDING A COMMERCIAL - TYPE IA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 3-HOUR RATED 1-HOUR RATED 1-HOUR RATED GARAGE - TYPE IA CODE BLDG SECTION BUILDING B RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 1-HOUR RATED 1-HOUR RATED 1-HOUR RATED 1-HOUR RATED CODE BLDG SECTION BUILDING C RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 1-HOUR RATED 1-HOUR RATED 1-HOUR RATED RESIDENTIAL - TYPE VA 1-HOUR RATED ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID DOCUMENTS LS112bBUILDING A - UPPERFLOOR CODE PLAN -AREA BNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A -UPPER FLOOR CODE PLAN -AREA B BUILDING A TOTAL OCCUPANCY: LOWER LEVEL 89 1ST FLOOR 399 2ND FLOOR 146 3RD FLOOR 146 TOTAL: 780 # DESCRIPTION DATE 04/15/22