HomeMy WebLinkAboutLS112b - BUILDING A - UPPER FLOOR CODE PLAN - AREA BCODE PLAN GRAPHICS LEGEND
1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO
EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL
AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO
EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR
EACH AREA OF SEPARATION AS INDICATED.
2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW.
PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING
ON BOTH SIDES.
3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1-HOUR FIRE
PARTITIONS PER IBC 708. SEE A340 SERIES.
4. CORRIDOR WALLS TO BE 1-HOUR FIRE PARTITIONS PER IBC 708.
SEE A340 SERIES.
5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR
FIRE BARRIERS PER IBC 707. SEE A160 SERIES.
6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC
707. SEE A340 SERIES.
7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE
WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN
BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH
3-HOUR RATED PODIUM.
8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND
ROOF/CEILING SPACES PER SECTION 718.
9. 20"X30" MIN. ATTIC ACCESS PANEL.
10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH
DRAFSTOPPING.
CODE PLAN NOTES #
NON-RATED ASSEMBLY
1 HR RATED ASSEMBLY
2 HR RATED ASSEMBLY
2 HR FIRE WALL
DRAFT STOP LOCATION
FIRE EXSTINGUISHER CABINET
DIRECTION OF TRAVEL
31 0
0"EXIT
OCCUPANT LOAD
THROUGH EXIT
EGRESS WIDTH
ALLOWABLE NUMBER
OF OCCUPANTS
THROUGH EXIT
LOAD FACTOR KEY
R - RESIDENTIAL - 200 GROSS
B - BUSINESS - 100 GROSS
S - STORAGE - 300 GROSS
STAIR WIDTH = X
DOOR WIDTH = X
xxx
STAIR WIDTH FACTOR
0.20" PER OCCUPANT
DOOR WIDTH FACTOR
0.15" PER OCCUPANT
EGRESS CAPACITY OF
STAIR
R-2 210SF
ROOM
#
1202 1
OCCUPANCY
GROUP
ROOM IDENTIFICATION
ROOM AREA
NUMBER OF EXITS
REQUIRED
OCCUPANT LOAD
FACTOR
NUMBER OF
OCCUPANTS
FEC
2-HR FW
A - ASSEMBLY - 15 GROSS
E - EXERCISE - 50 GROSS
U - GARAGE - 200 GROSS
2-HR FW2-HR FW 2-HR FW1 / LS112a 1 / LS112a
UNIT B2
226
1202SF
200
R2 16
UNIT B2
227
1202SF
200
R2 16
UNIT B3b
224
1276SF
200
R2 1 7
UNIT A1
IDD
222
831SF
200
R2 1 5
UNIT A1
IDD
220
831SF
200
R2 1 5
UNIT A2
218
828SF
200
R2 15
UNIT A2
IDD
225
828SF
200
R2 15
UNIT A1
IDD
223
831SF
200
R2 15
UNIT A1
IDD
219
831SF
200
R2 15
UNIT A2
221
828SF
200
R2 15
DOOR WIDTH = 34"
120
STAIR WIDTH = 36"
27
227
34"
27
F.E.C.(54) TOTAL OCCUPANCYF.E.C.
F.E.C.
F.E.C.
9
9
9
4
3
TYP.
5
5
103SF
1
S-2
STORAGE
S202
300 1
AREA A
AREA B
FIRE AREA DIAGRAM - BUILDING A
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING A
COMMERCIAL - TYPE IA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
3-HOUR
RATED
1-HOUR
RATED
1-HOUR
RATED
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING B
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
1-HOUR
RATED
1-HOUR
RATED
1-HOUR
RATED
1-HOUR
RATED
CODE BLDG SECTION
BUILDING C
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
1-HOUR
RATED
1-HOUR
RATED
1-HOUR
RATED
RESIDENTIAL - TYPE VA
1-HOUR
RATED
ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID DOCUMENTS
LS112bBUILDING A - UPPERFLOOR CODE PLAN -AREA BNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A -UPPER FLOOR CODE PLAN -AREA B
BUILDING A TOTAL OCCUPANCY:
LOWER LEVEL 89
1ST FLOOR 399
2ND FLOOR 146
3RD FLOOR 146
TOTAL: 780
# DESCRIPTION DATE
04/15/22