Loading...
HomeMy WebLinkAboutPool Pump Sound Data2882 Whiptail Loop # 100 Carlsbad, CA 92010 T. 800 822 7933 FluidraUSA.com SUMMARY OF SOUND DATA TAKEN FROM VARIOUS ZODIAC/JANDY PUMPS. (Product Safety & Compliance Department - Jan 2021) Summary: Sound testing was performed at Intertek Labs. A description of the standard used and equipment is stated in the report and is shown here for reference: TEST METHOD The laboratory method used in conducting this test is in accordance with ANSI S12.51-2012/ISO 3741:2010, Acoustics – Determination of sound power levels of noise sources using sound pressure – Precision method for reverberation rooms Intertek Acoustical Facilities utilizes a 16,640 cu. ft. (470 cubic meter) reverberation room, which has been qualified for testing to the above standard. FINAL DATA: The sound level for various Jandy/Zodiac pumps is given in the tables below. The sound power level is calculated from the reverberation data and is assuming either a motor/pump speed (rpm), or flow (gpm), as specified below in each table. The data provided also is specific to a particular distance from the pump as shown in the header for each table below. 2882 Whiptail Loop # 100 Carlsbad, CA 92010 T. 800 822 7933 FluidraUSA.com 2882 Whiptail Loop # 100 Carlsbad, CA 92010 T. 800 822 7933 FluidraUSA.com