HomeMy WebLinkAboutRiviera_3500 B Sealed Truss Engineering 1700422Re:
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Timberland Home Center-Brazil, IN.
Fox, Steve
Pages or sheets covered by this seal: I30950485 thru I30950518
My license renewal date for the state of Indiana is July 31, 2018.
1700422
Truss Engineer’s responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
IMPORTANT NOTE:
RIVIERA/3500 B
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
September 5,2017
Job
1700422
Truss
A
Truss Type
Common
Qty
10
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950485
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:34 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-E97QHC9NV6lPpvwMQF1c5F6ROnbdU5qcULHZwsyi_hp
Scale = 1:66.9
1 2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17 183x6
5x6
3x6
3x8
3x6 3x8
3x4
3x4
2x4
3x4
3x4
2x4
3x6
3x8
9-1-13
9-1-13
18-0-0
8-10-3
26-10-3
8-10-3
36-0-0
9-1-13
-0-11-4
0-11-4
6-2-7
6-2-7
12-1-3
5-10-13
18-0-0
5-10-13
23-10-13
5-10-13
29-9-9
5-10-13
36-0-0
6-2-7
36-11-4
0-11-4
0-5-710-11-70-5-77.00 12
Plate Offsets (X,Y)-- [2:0-8-0,0-0-1], [10:0-8-0,0-0-1]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.65
0.85
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.52
0.13
(loc)
10-12
10-12
10
l/defl
>999
>824
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 151 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
6-14,7-14,5-14: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-10-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-14, 5-14
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=1493/0-3-8, 10=1493/0-3-8
Max Uplift 2=-115(LC 6), 10=-115(LC 6)
Max Grav 2=1606(LC 12), 10=1606(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2566/175, 3-5=-2373/192, 5-6=-1703/214, 6-7=-1703/214, 7-9=-2373/192,
9-10=-2566/175
BOT CHORD 2-16=-63/2116, 14-16=0/1698, 12-14=0/1698, 10-12=-63/2116
WEBS 6-14=-111/1267, 7-14=-711/138, 7-12=0/512, 9-12=-352/135, 5-14=-711/138,
5-16=0/512, 3-16=-352/135
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=115, 10=115.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
A1
Truss Type
Common
Qty
9
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950486
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:35 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jLhoUXA0GQtGR3VY_yYrdSea_BxPDY?lj?16SIyi_ho
Scale = 1:66.4
1
2
3
4
5
6
7
8
9 10
15 14 13 12 11
16 17
3x6
5x6
3x6
3x8
3x6 3x8
3x4
3x4
2x4
3x4
3x4
2x4
3x6
3x8
9-1-13
9-1-13
18-0-0
8-10-3
26-10-3
8-10-3
36-0-0
9-1-13
6-2-7
6-2-7
12-1-3
5-10-13
18-0-0
5-10-13
23-10-13
5-10-13
29-9-9
5-10-13
36-0-0
6-2-7
36-11-4
0-11-4
0-5-710-11-70-5-77.00 12
Plate Offsets (X,Y)-- [1:0-8-0,0-0-1], [9:0-8-0,0-0-1]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.78
0.88
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.20
-0.56
0.13
(loc)
1-15
1-15
9
l/defl
>999
>762
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 150 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-13,6-13,4-13: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-13, 4-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1431/Mechanical, 9=1498/0-3-8
Max Horz 1=-18(LC 6)
Max Uplift 1=-81(LC 6), 9=-116(LC 6)
Max Grav 1=1570(LC 12), 9=1610(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2597/182, 2-4=-2399/197, 4-5=-1711/215, 5-6=-1711/215, 6-8=-2381/193,
8-9=-2574/177
BOT CHORD 1-15=-72/2152, 13-15=0/1711, 11-13=0/1705, 9-11=-64/2123
WEBS 5-13=-112/1275, 6-13=-711/137, 6-11=0/512, 8-11=-352/135, 4-13=-722/139,
4-15=0/533, 2-15=-374/143
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
9=116.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
A2
Truss Type
Common
Qty
5
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950487
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:35 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jLhoUXA0GQtGR3VY_yYrdSea_BxPDY?lj?16SIyi_ho
Scale = 1:65.9
1
2
3
4
5
6
7
8
9
14 13 12 11 10
15 16
3x6
5x6
3x6
3x8
3x6 3x8
3x4
3x4
2x4
3x4
3x4
2x4
3x8
3x6
9-1-13
9-1-13
18-0-0
8-10-3
26-10-3
8-10-3
36-0-0
9-1-13
6-2-7
6-2-7
12-1-3
5-10-13
18-0-0
5-10-13
23-10-13
5-10-13
29-9-9
5-10-13
36-0-0
6-2-7
0-5-710-11-70-5-77.00 12
Plate Offsets (X,Y)-- [1:0-8-0,0-0-1], [9:0-8-0,0-0-1]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.78
0.88
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.20
-0.56
0.13
(loc)
9-10
9-10
9
l/defl
>999
>763
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 149 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-12,6-12,4-12: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-12, 4-12
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1432/0-3-8, 9=1432/Mechanical
Max Uplift 1=-81(LC 6), 9=-81(LC 6)
Max Grav 1=1571(LC 11), 9=1571(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2578/182, 2-4=-2385/198, 4-5=-1712/216, 5-6=-1712/216, 6-8=-2400/198,
8-9=-2598/183
BOT CHORD 1-14=-89/2122, 12-14=-2/1700, 10-12=-2/1706, 9-10=-91/2147
WEBS 5-12=-113/1275, 6-12=-722/139, 6-10=0/533, 8-10=-374/143, 4-12=-712/138,
4-14=0/516, 2-14=-356/141
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
AG
Truss Type
Common Supported Gable
Qty
2
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950488
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:36 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-BYFBhtBe1k?72D4kYg45AgBuwbTIy21vxfmg_kyi_hn
Scale = 1:67.5
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7
8 9 10
11
12
13
14
15
16
17
18
19
20
2122
23
24
25
26
27
28
53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29
54 553x6
5x6
3x6
3x6
3x6 3x6
3x6
36-0-0
36-0-0
18-0-0
18-0-0
36-0-0
18-0-0
36-11-4
0-11-4
0-5-710-11-70-5-77.00 12
Plate Offsets (X,Y)-- [20:0-1-10,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.13
0.07
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.01
(loc)
28
28
27
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 246 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3 *Except*
14-41,13-42,12-43,11-44,15-40,16-39,17-38: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 14-41, 13-42, 12-43, 11-44, 15-40, 16-39,
17-38
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 36-0-0.
(lb) - Max Horz 1=-18(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 41, 43, 44, 45, 47, 48, 49, 50, 51,
52, 53, 39, 38, 37, 35, 34, 33, 32, 31, 30, 29
Max Grav All reactions 250 lb or less at joint(s) 1, 41, 42, 43, 44, 45, 47, 48, 49,
50, 51, 52, 40, 39, 38, 37, 35, 34, 33, 32, 31, 30, 27 except 53=328(LC 12),
29=317(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are 2x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 41, 43, 44, 45,
47, 48, 49, 50, 51, 52, 53, 39, 38, 37, 35, 34, 33, 32, 31, 30, 29.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
B
Truss Type
Common
Qty
4
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950489
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:37 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-fkpZvDBGo18zgMex6NbKjtj?2?eMhMK2AJWDXByi_hm
Scale = 1:68.3
1
2
3
4
5
6
78
12 11 10 9
3x6
4x6
3x6
3x6 3x8
4x6 4x6
2x8
3x6 3x6
2x8
10-0-0
10-0-0
20-0-0
10-0-0
5-1-12
5-1-12
10-0-0
4-10-4
14-10-4
4-10-4
20-0-0
5-1-12
20-11-4
0-11-4
1-3-811-3-81-3-812.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.43
0.78
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.47
0.02
(loc)
9-10
9-10
9
l/defl
>999
>505
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 105 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-10: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)12=787/0-3-8, 9=855/0-3-8
Max Horz 12=-47(LC 4)
Max Uplift 12=-45(LC 4), 9=-79(LC 4)
Max Grav 12=864(LC 8), 9=905(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-356/117, 2-4=-766/171, 4-6=-764/170, 6-7=-397/169, 1-12=-344/101,
7-9=-418/175
BOT CHORD 10-12=0/510, 9-10=0/506
WEBS 4-10=-142/645, 6-10=-271/179, 2-10=-278/180, 2-12=-565/0, 6-9=-539/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 9.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
B1G
Truss Type
Common Structural Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950490
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:38 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-7wMx6ZCuZLGqIWD7f56ZF5G9kO04QrgBPyFm3dyi_hl
Scale = 1:67.9
Sheet Front
Full Sheathing
1 Ply 7/16" 4x8 OSB
1 2
3
4
5
6
7
89
19 18 17
15 14 13 12 11 1016
4x9
4x6
4x9
3x8
4x6 4x6
8x8
8x8
5x6
10-0-0
10-0-0
12-0-0
2-0-0
20-0-0
8-0-0
-0-11-4
0-11-4
5-1-12
5-1-12
10-0-0
4-10-4
14-10-4
4-10-4
20-0-0
5-1-12
20-11-4
0-11-4
0-10-210-10-20-10-212.00 12
Plate Offsets (X,Y)-- [2:Edge,0-2-12], [2:0-1-12,0-1-12], [4:0-4-8,0-2-4], [4:0-0-0,0-1-12], [6:0-0-0,0-1-12], [6:0-4-8,0-2-4], [8:0-1-12,0-1-12], [10:Edge,0-2-12], [18:0-3-0,0-3-0],
[23:0-2-8,0-0-0], [35:0-2-8,0-0-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.49
0.69
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.57
0.02
(loc)
17-19
17-19
10
l/defl
>629
>245
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 325 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-17: 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 8-3-8 except (jt=length) 19=0-3-8, 16=0-3-8.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 19, 10, 15 except 16=-205(LC 3)
Max Grav All reactions 250 lb or less at joint(s) 15, 14, 13, 12, 11, 16 except
19=881(LC 8), 10=819(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-593/128, 3-5=-745/148, 5-7=-745/148, 7-8=-449/182, 2-19=-556/146,
8-10=-456/184
BOT CHORD 17-19=0/530, 16-17=0/522, 15-16=0/522, 14-15=0/522, 13-14=0/522, 12-13=0/522,
11-12=0/522, 10-11=0/522
WEBS 5-17=-109/614, 7-17=-292/178, 3-17=-303/174, 3-19=-366/0, 7-10=-494/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 10, 15 except
(jt=lb) 16=205.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
BG
Truss Type
Common Supported Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950491
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:39 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-b6wJKvDWKfOhvgoJDodooIpPooUY9MQLec?Kb3yi_hk
Scale = 1:67.9
Sheet Front
Full Sheathing
1 Ply 7/16" 4x8 OSB
1 2 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 21
39 3837 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22
2x8
3x6
4x6
3x6
2x8
3x6
20-0-0
20-0-0
-0-11-4
0-11-4
10-0-0
10-0-0
20-0-0
10-0-0
20-11-4
0-11-4
1-3-811-3-81-3-812.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.15
0.10
0.20
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
20
20
22
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 323 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
11-30,10-31,8-33,12-29,14-28: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 11-30, 10-31, 8-33, 12-29, 14-28
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 20-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 33, 34, 35, 36, 37, 28, 27, 26, 25, 24 except 39=-164(LC 5),
22=-164(LC 5), 30=-200(LC 5), 38=-173(LC 4), 23=-173(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 39, 22, 31, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24,
23 except 30=379(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-10=-209/284, 10-11=-226/302, 11-12=-226/302, 12-14=-209/284
WEBS 11-30=-363/227
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 34, 35, 36,
37, 28, 27, 26, 25, 24 except (jt=lb) 39=164, 22=164, 30=200, 38=173, 23=173.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
BGR
Truss Type
Common Girder
Qty
1
Ply
3
RIVIERA/3500 B
Job Reference (optional)
I30950492
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:40 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-3JUhXFE85yWYXqNVnV81KWLSMCfzujCUsGkt7Wyi_hj
Scale = 1:71.8
1
2
3
4
5
6
7
11 10 9 81213141516 17 18
3x6
4x6
3x6
4x9
4x6 10x10
3x8
3x10
3x8
3x10
4x9
HUS26
HUS26 HUS26
HUS26
5-0-3
5-0-3
10-0-0
4-11-13
14-11-13
4-11-13
20-0-0
5-0-3
5-0-3
5-0-3
10-0-0
4-11-13
14-11-13
4-11-13
20-0-0
5-0-3
0-10-210-10-20-10-212.00 12
Plate Offsets (X,Y)-- [1:0-0-3,0-0-3], [1:0-0-5,0-5-3], [7:0-0-3,0-0-3], [7:0-0-5,0-6-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.68
0.79
0.61
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.18
0.04
(loc)
8-9
8-9
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 370 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SP No.1
WEBS 2x4 SPF Stud/No.3 *Except*
4-9: 2x4 SPF No.2
WEDGE
Left: 2x8 SP No.2, Right: 2x10 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=7206/0-3-8, 7=7405/0-3-8
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-8413/0, 2-4=-5611/10, 4-6=-5611/0, 6-7=-8533/0
BOT CHORD 1-11=0/5579, 9-11=0/5579, 8-9=0/5661, 7-8=0/5661
WEBS 4-9=0/7490, 6-9=-2615/86, 6-8=0/4003, 2-9=-2495/45, 2-11=0/3826
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at
2-0-12 from the left end to 8-0-12 to connect truss(es) to back face of bottom chord.
7) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-7=-60, 1-7=-20
Concentrated Loads (lb)
Vert: 10=-1412(B) 9=-1478 12=-1412(B) 13=-1412(B) 14=-1412(B) 15=-1478 16=-1478 17=-1478 18=-1478
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
C
Truss Type
Common
Qty
7
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950493
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:40 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-3JUhXFE85yWYXqNVnV81KWLZ3ChZupSUsGkt7Wyi_hj
Scale = 1:39.6
1
2
3
4
5
6
7
8
4x6
3x8 5x9
2x4 2x4
3x8
9-0-0
9-0-0
18-0-0
9-0-0
-0-11-4
0-11-4
4-7-0
4-7-0
9-0-0
4-5-0
13-5-0
4-5-0
18-0-0
4-7-0
18-11-4
0-11-4
0-6-66-6-60-6-68.00 12
Plate Offsets (X,Y)-- [2:0-0-11,0-1-0], [2:0-1-5,0-5-8], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-1-5,0-5-8], [6:0-0-11,0-1-0], [8:0-4-8,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.25
0.69
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.34
0.03
(loc)
6-8
6-8
6
l/defl
>999
>627
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 68 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-6-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=773/0-3-8, 6=773/0-3-8
Max Uplift 2=-74(LC 4), 6=-74(LC 4)
Max Grav 2=816(LC 8), 6=816(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1036/99, 3-4=-818/89, 4-5=-818/89, 5-6=-1036/99
BOT CHORD 2-8=-3/788, 6-8=-3/788
WEBS 4-8=-14/558, 5-8=-302/118, 3-8=-302/118
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
CG
Truss Type
Common Supported Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950494
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:41 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-XV24lbEmsGeP9_yiLDfGtjumOcB3dIue5wURgyyi_hi
Scale = 1:40.8
1
2
3
4
5
6
7
8
9
10
11
12
13
14 15
27 2625 24 23 22 21 20 19 18 17 16
4x6
3x4
3x8 3x6
3x4
3x8
18-0-0
18-0-0
-0-11-4
0-11-4
9-0-0
9-0-0
18-0-0
9-0-0
18-11-4
0-11-4
0-6-66-6-60-6-68.00 12
Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [2:0-2-3,Edge], [14:0-0-0,0-0-13], [14:0-2-3,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.08
0.03
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
15
15
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 94 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 18-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14
Max Grav All reactions 250 lb or less at joint(s) 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21, 22, 23, 24,
26, 27, 20, 19, 18, 17, 16, 14.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
CGR
Truss Type
Common Girder
Qty
1
Ply
3
RIVIERA/3500 B
Job Reference (optional)
I30950495
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:41 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-XV24lbEmsGeP9_yiLDfGtjugScy7d4ie5wURgyyi_hi
Scale = 1:41.0
1
2
3
4
5
9 8 7 61011121314 15 163x8
4x6
3x8 5x6 10x10
3x8
3x10
3x8
3x10
HUS26
HUS26
HUS26
HUS26
4-8-8
4-8-8
9-0-0
4-3-8
13-3-8
4-3-8
18-0-0
4-8-8
4-8-8
4-8-8
9-0-0
4-3-8
13-3-8
4-3-8
18-0-0
4-8-8
0-6-66-6-60-6-68.00 12
Plate Offsets (X,Y)-- [1:0-8-0,0-0-11], [5:0-8-0,0-0-11]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.46
0.99
0.98
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.18
0.06
(loc)
7-9
7-9
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 246 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=6389/0-3-8, 5=6318/0-3-8
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-9285/0, 2-3=-6315/0, 3-4=-6315/0, 4-5=-9276/0
BOT CHORD 1-9=0/7512, 7-9=0/7512, 6-7=0/7504, 5-6=0/7504
WEBS 3-7=0/6660, 4-7=-2898/0, 4-6=0/3375, 2-7=-2908/0, 2-9=0/3385
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at
9-11-4 from the left end to 15-11-4 to connect truss(es) to back face of bottom chord.
7) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 1-5=-20
Concentrated Loads (lb)
Vert: 8=-1412 10=-1412 11=-1412 12=-1412 13=-1411(B) 14=-1411(B) 15=-1411(B) 16=-1411(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
DG
Truss Type
Common Supported Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950496
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:42 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-0hcSyxFPdamGm8XuuwAVQxRxZ0X_MkenKaD_COyi_hh
Scale = 1:42.8
Sheet Front
Full Sheathing
1 Ply 7/16" 4x8 OSB
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
3x8
4x6
3x8
12-0-0
12-0-0
-0-11-4
0-11-4
6-0-0
6-0-0
12-0-0
6-0-0
12-11-4
0-11-4
0-10-26-10-20-10-212.00 12
Plate Offsets (X,Y)-- [10:0-4-12,0-1-8], [20:0-4-12,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.12
0.05
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 129 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 12-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except 16=-106(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18,
19, 15, 14, 13 except (jt=lb) 16=106.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
E
Truss Type
MONO
Qty
4
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950497
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:42 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-0hcSyxFPdamGm8XuuwAVQxRwW0PQMlUnKaD_COyi_hh
Scale = 1:19.2
1
2
3
4
5
6
7
2x4
3x4
3x4
3x4
2x4
6-10-8
6-10-8
7-0-0
0-1-8
-0-11-4
0-11-4
3-4-14
3-4-14
6-10-8
3-5-10
7-0-0
0-1-8
0-7-152-11-154.00 12
Plate Offsets (X,Y)-- [2:0-2-4,0-0-7]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.19
0.54
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.33
0.00
(loc)
2-6
2-6
6
l/defl
>621
>249
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 26 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
SLIDER Left 2x4 SPF Stud/No.3 1-8-6
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=334/0-3-8, 6=270/0-3-8
Max Horz 2=32(LC 7)
Max Uplift 2=-100(LC 6), 6=-69(LC 6)
Max Grav 2=342(LC 9), 6=300(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-368/155
BOT CHORD 2-6=-135/300
WEBS 4-6=-322/187
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
E1
Truss Type
MONO
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950498
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:43 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-UuAq9HG1Otu7OH64Seiky8z_?PoH5DWxYEzXkqyi_hg
Scale = 1:17.2
1
2
3
4
5
6
2x4
3x4
3x4
3x4
2x4
5-10-8
5-10-8
6-0-0
0-1-8
-0-11-4
0-11-4
5-10-8
5-10-8
6-0-0
0-1-8
0-7-152-7-154.00 12
Plate Offsets (X,Y)-- [2:0-2-4,0-0-7]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.59
0.37
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.18
0.00
(loc)
2-5
2-5
5
l/defl
>997
>399
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 21 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
SLIDER Left 2x4 SPF Stud/No.3 3-0-5
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=295/0-3-8, 5=230/0-3-8
Max Horz 2=30(LC 6)
Max Uplift 2=-95(LC 6), 5=-63(LC 6)
Max Grav 2=301(LC 9), 5=251(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
EG
Truss Type
Monopitch Structural Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950499
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:43 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-UuAq9HG1Otu7OH64Seiky8z_?Prg5DWxYEzXkqyi_hg
Scale = 1:17.9
Sheet Back
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
6 5
8
2x4
2x4 3x4
3x4
3x4
2x4
2x4
6-0-0
6-0-0
-0-11-4
0-11-4
6-0-0
6-0-0
0-7-152-7-154.00 12
Plate Offsets (X,Y)-- [2:0-2-4,0-0-7]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.59
0.15
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.04
0.00
(loc)
2-6
2-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
SLIDER Left 2x4 SPF Stud/No.3 3-0-5
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 6-0-0.
(lb) - Max Horz 2=30(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except 5=-114(LC 6), 2=-108(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 5, 5, 6 except 2=279(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 114 lb uplift at joint 5 and 108 lb uplift at
joint 2.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
EGR
Truss Type
MONO TRUSS
Qty
1
Ply
2
RIVIERA/3500 B
Job Reference (optional)
I30950500
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:44 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-y4kCNcHf9B0_0RhH0LDzVMWD7p5EqbS4nui5GHyi_hf
Scale = 1:19.2
1
2
3
4
6
5
7 8 9
3x4
2x4
2x4
3x6
4x6
3-7-14
3-7-14
7-0-0
3-4-2
-0-11-4
0-11-4
3-7-14
3-7-14
7-0-0
3-4-2
0-7-152-11-154.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.37
0.51
0.34
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.04
0.01
(loc)
2-6
2-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 59 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)2=1296/0-3-8, 5=1608/0-3-8
Max Horz 2=35(LC 6)
Max Uplift 2=-71(LC 6), 5=-17(LC 6)
Max Grav 2=1305(LC 9), 5=1639(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2184/10
BOT CHORD 2-6=-5/1970, 5-6=-5/1970
WEBS 3-6=0/1541, 3-5=-2176/48
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 2 and 17 lb uplift at
joint 5.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 2-5=-20, 1-4=-60
Concentrated Loads (lb)
Vert: 7=-767 8=-767 9=-769
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
F
Truss Type
MONO
Qty
4
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950501
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:44 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-y4kCNcHf9B0_0RhH0LDzVMWAOp8qqgm4nui5GHyi_hf
Scale = 1:15.5
1
2
3
4
5
2x4
2x4
2x4
5-10-8
5-10-8
6-0-0
0-1-8
-0-11-4
0-11-4
5-10-8
5-10-8
6-0-0
0-1-8
0-3-152-3-154.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.55
0.35
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.16
0.00
(loc)
2-4
2-4
4
l/defl
>999
>430
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 17 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=300/0-3-8, 4=222/0-3-8
Max Horz 2=43(LC 6)
Max Uplift 2=-103(LC 6), 4=-59(LC 6)
Max Grav 2=305(LC 9), 4=243(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 2 and 59 lb uplift at
joint 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
F1
Truss Type
MONO
Qty
5
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950502
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:45 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-QGHaayIHwV8rebGTa3kC1Z3RmDXMZ70D0YSepjyi_he
Scale = 1:11.1
1
2
3
4
5
2x4
2x4
2x4
3-10-8
3-10-8
4-0-0
0-1-8
-0-11-4
0-11-4
3-10-8
3-10-8
4-0-0
0-1-8
0-3-151-7-154.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.19
0.14
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.00
(loc)
2-4
2-4
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=223/0-3-8, 4=139/0-3-8
Max Horz 2=34(LC 6)
Max Uplift 2=-88(LC 6), 4=-36(LC 6)
Max Grav 2=225(LC 9), 4=146(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 88 lb uplift at joint 2 and 36 lb uplift at
joint 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
FG
Truss Type
Monopitch Supported Gable
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950503
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:45 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-QGHaayIHwV8rebGTa3kC1Z3KWDUlZ70D0YSepjyi_he
Scale = 1:14.9
Sheet Back
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
2x4
2x4 2x4
-0-11-4
0-11-4
6-0-0
6-0-0
0-3-152-3-154.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.59
0.37
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
0.07
0.00
(loc)
1
1
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 17 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)4=230/6-0-0, 2=295/6-0-0
Max Horz 2=43(LC 6)
Max Uplift 4=-61(LC 6), 2=-98(LC 6)
Max Grav 4=251(LC 9), 2=301(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 4 and 98 lb uplift at
joint 2.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V1
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950504
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:46 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-uTrzoIIvgoGiFlqf7mFRanbYCdpIIWmNFCBBL9yi_hd
Scale = 1:60.1
1
2
3
4
5
9 8 7 63x4
4x6
3x4
3x6 2x4 2x4
2x4
2x4
2x4
19-5-10
19-5-10
9-8-13
9-8-13
19-5-10
9-8-13
9-8-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.40
0.35
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 75 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
5-7: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
3-8: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-8
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 19-5-10.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 8 except 9=-194(LC 4), 6=-194(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=616(LC 7), 6=616(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-479/247, 4-6=-481/248
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
9=194, 6=194.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V2
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950505
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfChxyQXomSIgiWgIP2yi_hb
Scale = 1:55.2
1
2
3
4
5
9 8 7 63x4
4x6
3x4
3x6
2x4
2x4
2x4
2x4
2x4
17-1-10
17-1-10
8-6-13
8-6-13
17-1-10
8-6-13
8-6-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.26
0.22
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 64 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
5-7: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-8
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 17-1-10.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-165(LC 4), 6=-165(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=516(LC 7), 6=516(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-407/211, 4-6=-408/212
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 165 lb uplift at joint 9 and 165 lb uplift at
joint 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V3
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950506
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:49 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-I2X5QKLozjeG6CZEpup8CPD7jquoVvqpxAQsyUyi_ha
Scale = 1:48.6
1
2
3
4
5
9 8 7 63x4
4x6
3x4
3x6
2x4 2x4
2x4
2x4
2x4
14-9-10
14-9-10
7-4-13
7-4-13
14-9-10
7-4-13
7-4-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.17
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 54 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-9-10.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-145(LC 4), 6=-145(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=436(LC 7), 6=436(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-352/187, 4-6=-352/187
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 145 lb uplift at joint 9 and 145 lb uplift at
joint 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V4
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950507
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:49 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-I2X5QKLozjeG6CZEpup8CPD70qvpVwTpxAQsyUyi_ha
Scale = 1:39.2
1
2
3
4
5
8 7 63x4
4x6
3x4
2x4 2x4
2x4
2x4
2x4
12-5-10
12-5-10
6-2-13
6-2-13
12-5-10
6-2-13
6-2-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.17
0.10
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 44 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 12-5-10.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-136(LC 4), 6=-136(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=386(LC 7), 6=386(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-322/177, 4-6=-322/177
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=136, 6=136.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V5
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950508
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:50 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-nE5TdgLQk1m7kM8QMcKNkdmC8EEgENly9q9PUwyi_hZ
Scale: 3/8"=1’
1
2
3
42x8
4x6
2x8
2x4
10-1-10
10-1-10
5-0-13
5-0-13
10-1-10
5-0-13
5-0-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.53
0.19
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 32 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=210/10-1-10, 3=210/10-1-10, 4=334/10-1-10
Max Uplift 1=-34(LC 4), 3=-34(LC 4)
Max Grav 1=236(LC 7), 3=236(LC 7), 4=364(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V6
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950509
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:50 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-nE5TdgLQk1m7kM8QMcKNkdmI1EE_ENzy9q9PUwyi_hZ
Scale: 3/8"=1’
1
2
3
4
5
9 8 7 63x4
4x6
3x4
3x6
2x4
2x4
2x4
2x4
2x4
14-8-13
14-8-13
7-4-6
7-4-6
14-8-13
7-4-6
4-10-158.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.15
0.17
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 45 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-8-13.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 9, 6
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=259(LC 1), 9=386(LC 7), 6=386(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-307/120, 4-6=-307/120
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V7
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950510
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJOzeawzrp6OUvy0Nyi_hY
Scale = 1:26.1
1
2
3
42x4
4x6
2x4 2x4
7-9-10
7-9-10
3-10-13
3-10-13
7-9-10
3-10-13
3-10-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.46
0.19
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=170/7-9-10, 3=170/7-9-10, 4=229/7-9-10
Max Uplift 1=-41(LC 4), 3=-41(LC 4)
Max Grav 1=197(LC 7), 3=197(LC 7), 4=238(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V8
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950511
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJNWeZOzqB6OUvy0Nyi_hY
Scale: 1/2"=1’
1
2
3
43x4
4x6
3x4 2x4
11-2-13
11-2-13
5-7-6
5-7-6
11-2-13
5-7-7
3-8-158.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.55
0.22
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 31 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=201/11-2-13, 3=201/11-2-13, 4=419/11-2-13
Max Uplift 1=-30(LC 4), 3=-30(LC 4), 4=-5(LC 4)
Max Grav 1=227(LC 7), 3=227(LC 7), 4=455(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-292/62
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V9
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950512
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJS6ebYzr86OUvy0Nyi_hY
Scale = 1:19.3
1
2
3
4
2x4
4x6
2x4 2x4
5-5-10
5-5-10
2-8-13
2-8-13
5-5-10
2-8-13
2-8-1312.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.20
0.09
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-5-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=114/5-5-10, 3=114/5-5-10, 4=153/5-5-10
Max Uplift 1=-30(LC 4), 3=-30(LC 4)
Max Grav 1=133(LC 7), 3=133(LC 7), 4=160(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V10
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950513
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:46 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-uTrzoIIvgoGiFlqf7mFRanbZtds1IadNFCBBL9yi_hd
Scale = 1:17.6
1
2
3
4
2x4
4x6
2x4 2x4
7-8-13
7-8-13
3-10-6
3-10-6
7-8-13
3-10-7
2-6-158.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.36
0.17
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 20 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=145/7-8-13, 3=145/7-8-13, 4=252/7-8-13
Max Uplift 1=-32(LC 4), 3=-32(LC 4)
Max Grav 1=167(LC 7), 3=167(LC 7), 4=268(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V11
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950514
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:47 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-MfPL?eJXR6OZtvPshUmg7_8jc1D_11kWTsxltcyi_hc
Scale = 1:16.4
1
2
3
4
5
6
2x4
4x6
2x4 2x4
8-11-8
8-11-8
4-5-12
4-5-12
8-11-8
4-5-12
2-2-146.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.42
0.13
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 22 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=156/8-11-8, 3=156/8-11-8, 4=305/8-11-8
Max Uplift 1=-49(LC 6), 3=-49(LC 6), 4=-27(LC 6)
Max Grav 1=160(LC 11), 3=160(LC 11), 4=305(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V12
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950515
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:47 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-MfPL?eJXR6OZtvPshUmg7_8nZ17H11VWTsxltcyi_hc
Scale: 1"=1’
1
2
3
2x4
3x6
2x4
6-3-8
6-3-8
3-1-12
3-1-12
6-3-8
3-1-12
1-6-146.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.17
0.49
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=202/6-3-8, 3=202/6-3-8
Max Uplift 1=-51(LC 6), 3=-51(LC 6)
Max Grav 1=207(LC 11), 3=207(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V13
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950516
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfCh_EQZcmUlgiWgIP2yi_hb
Scale = 1:10.6
1
2
3
2x4
3x6
2x4
3-1-10
3-1-10
1-6-13
1-6-13
3-1-10
1-6-13
1-6-1312.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.05
0.10
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 8 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-1-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=97/3-1-10, 3=97/3-1-10
Max Uplift 1=-11(LC 4), 3=-11(LC 4)
Max Grav 1=109(LC 7), 3=109(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
V14
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950517
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfChznQXAmUlgiWgIP2yi_hb
Scale = 1:9.8
1
2
3
2x4
3x6
2x4
4-2-13
4-2-13
2-1-6
2-1-6
4-2-13
2-1-7
1-4-158.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.07
0.19
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 9 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-2-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=131/4-2-13, 3=131/4-2-13
Max Uplift 1=-15(LC 4), 3=-15(LC 4)
Max Grav 1=147(LC 7), 3=147(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
Job
1700422
Truss
VG1
Truss Type
Valley
Qty
1
Ply
1
RIVIERA/3500 B
Job Reference (optional)
I30950518
8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:52 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jdDE2MNgGe1rzgIpU1Mrq2rbc2wbiIrFd8eWYpyi_hX
Scale = 1:20.0
Sheet Back
Full Sheathing
1 Ply 7/16" 4x8 OSB
1
2
3
4
5
8 7 63x4
4x6
3x4 2x4 2x4
2x4
2x4
2x4
11-7-8
11-7-8
5-9-12
5-9-12
11-7-8
5-9-12
2-10-146.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.10
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 55 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-7-8.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 except 7=-118(LC 11)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=355(LC 11), 6=355(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6 except
(jt=lb) 7=118.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 5,2017
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.