Loading...
HomeMy WebLinkAbout06020027-Site Plan .. ~.., , Schneider This Plot Plan Prepared For: R.H. of InCllano Lot # 34 ,containing 6,933 S.F.:!:, in Stanford Park Section # 1 INSlR. # 200500009385 P.c. # 3, Slide # sn CERnACA 1E of CORRECnON INSlR. # 200500044195 Clay Twp, HamBton County See 29, TIaN, RJE 3400 Windy Knoll Lone Carmel, IN 46074 Prepared Dote: 01/25/06: By: AMA Proposed Buyer(s): Carmela & Sharon Deogrocias The Schneider Corporation 8901 0Ua Avenue HIstoric Fort Harrison IndlanapolJJ. Indlana 46216-103'1 317-626-7100 317-626-7200 FAX (70' R/W) Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregate = 6 (B.H.) R.H. of Indiana Finished Floor Elevation Information Pod Grode = 919.8 per plan Pad Grade + 0.7' = Garage FIT (920.5) Garage FFE + 1.5' = Residential FFE (922.0) Residential FFE - 9.0' = Basement FFE (913.0) Note: The garage finished floor elevation is 1.3' above the curb at the drive, per pion. EngineerJno '""'''"'' Landscape Arehitecture GIS . LIS GeoloiY Note: This drawing is based on construction plans or record drawings, and Is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drowing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of 011 liability. Note: The basement elevatioo, depicted hereoo, has been determined and based upon the pad grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or soil t)pes has been provided or stated on said plans. It is recommended that the basement finished floor e1eV<ltions be at least two feet (2') above the normal pool elevation of any adjoining bodies of water, unless a study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be ploced by builder os needed. Plot Plan Legend ~ Proposed Grades 000.0 Existing Grodes __ 000.0-- Contour Grade * Approx. Loterol Location - . - Sanitary Sewer Unes -If- Storm Sewer Unes - IJ - Water Service Lines - - - - - - - Sub- Surface Drain Unes . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) IIID Curb Inlet (Storm) D End Section (Storm) .... Fire Hydront - 0 0 0 _ c 0 c - Flow Une of swale Building Une (BL / BSL) - - - - - - - Easement Une Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 920.50 Downstream Manhole, TC=918.20 per plan. Ground Cover Calculations Drive = 612 SFf Public Walk = 152 SFf Privote Walk = 52 SF f Hydraseeding =n/o SFf Sod = 490 Sri. from entire yard DetoH of Ground/ StO<Tl1 Water flow pattern for indi'>'iduallots. Lot # 34 Vb06. 004 7956 ij ~ =Ji::!i= Note: Builder to ensure positive drainage away from structure(s). ij Assumed North Scale: " = 30' -- .. 1915.01 L______ TC= 915.00 PER PLAN 51.83' ---, 65.0 ' Lo I~ ~J@!J "':j .s FLOOD HAZARD STATEMENT CERTlFICA TlON "\\\1\\\\\11111111/1//1//1. ~""\~ c. L " 1//<<% #" ~;).......:.....o1'.0~ # ~,,"~G\SNT~~~.....~...o% ~~...~ 0 () ". ,.o~ I ( S0303 ) i % ..... STATE OF ..... ~ ;;::;; /'. ,'~ ~( A.....:.ivDIA~~.....~~ '%/#J ..S....U..Q\i<."-"# ~/, l\ '1l.,.~~-$ 1///IiII1III1III11\1\\\\\\~ ~lr-v Sidewalk to be placed 7' from property line, 5' from back of curb, per plan. REVISION #1 REVISED HOUSE DIMENSIONS 01/27/06 AMA t z i' o '1 S Pf: -.!. TC:920.50 PER PlAN :' 5\..oe€. Note: Per Carmel zoolng ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however 0 dwelling may be increased In height to thirty-five feet (35') provided the side and rear >'Ords ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. T'l'PICAL SWALE SECTION Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and 10 any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003), SIGNA lURE : DATE: SIGNA lURE REPRESENTS CON~RMA ~ON OF RECEIPT OF PLOT PLAN BY CUSTOMER.