HomeMy WebLinkAboutHyundai Office Expansion_BID Permit Set.pdfOCCUPANCY CALCULATIONS BASED ON 2012 IBC TABLE 1004.1.2 - MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT ALLOWANCE AREA (GROSS) OCCUPANTS TOTAL OCCUPANT LOAD 2,994 SF FUNCTION OF SPACE GENERAL OFFICE (EX'G) 100 GROSS ALLOWED ACTUAL 1,928 SF 20 30 20 32 PANTRY OCCUPANCY CLASS BUSINESS ROOM AREAS: 487 SF PAYROLL OFFICE 252 SF 100 GROSS 120 SF 2 2 OFFICE ADDITION BUSINESS 100 GROSS 5 6 BUSINESS OFFICE MANAGER BUSINESS 100 GROSS 207 SF 2 2 BUSINESS 100 GROSS 3 0 DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A0.0 I HEREBY CERTIFY THAT THESE DRAWINGS WERE PREPARED UNDER MY PERSONAL SUPERVISION AND THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THEY COMPLY WITH ALL LAWS, CODES AND ORDINANCES OF THE CITY OF CARMEL AND THE STATE OF INDIANA, INCLUDING THE ACCESSIBILITY STANDARDS OF THE STATE OF INDIANA. SIGNED: DATE: JULY 9, 2021 FREDERICK GRIER STATE OF INDIANA ARCHITECT BOARD REGISTRATION NO. AR12000154 EXPIRATION 12-31-2021 VICINITY MAP NOT TO SCALE PROJECT CONTACTS GENERAL DRAWING NOTES OFFICE REMODEL EXIT PATH 101'-6" DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A0.1 FIRE & LIFE SAFETY PLANS & PROJECT DATA 05-10-21 PROJECT DATA USE GROUP S-1 USE GROUP B USE GROUP B USE GROUP S-1 USE GROUP B OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW 07-09-21 5 6 8 10 K G H K G H 5 6 8 10 DEMOLITION SYMBOLS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 D1.0 DEMOLITION PLAN AND RCP DEMOLITION GENERAL NOTES 06-16-21 DEMOLITION KEYNOTES 07-09-21 5 6 8 10 K G H K G H 5 6 8 10 CEILING SYMBOLS OS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A1.0 CONSTRUCTION AND REFLECTED CEILING PLANS CONSTRUCTION KEYNOTES CONSTRUCTION GENERAL NOTES 05-10-21 07-09-21 PF-01 AC-01 AC-02 AC-02 5 6 8 10 K G H 5 6 8 10 K G H FN-3L FN-4 FN-5A FN-6 FN-7 FN-8 3-DRAWER FILE CABINET FURNITURE SCHEDULE WORK TABLE BREAK ROOM TABLE FN-5B 5-DRAWER FILE CABINET FN-3R ELECTRICAL SYMBOLS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A2.0 POWER / DATA AND FURNITURE PLANS POWER / DATA KEYNOTES 05-10-21 POWER / DATA GENERAL NOTES 07-09-21 5 6 8 10 K G H INTERIOR FINISH SCHEDULE LIGHTING FIXTURE SCHEDULE EQUIPMENT / FIXTURE SCHEDULE DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A3.0 FINISH PLAN AND SCHEDULES 06-14-21 GENERAL NOTES FINISH PLAN KEYNOTES 07-09-21 SEE SCHEDULE 2" 2" 2" TYPE - F SEE SCHEDULE VIF VIF SEE SCHEDULE DOOR NUMBER DOOR TYPE MATERIAL LOUVRE FINISH GLASS FIRE LABEL ROOM NAME REV No. DESCRIPTION / SIZE FINISH MATERIAL REMARKS HARDWARE SET OFFICE MANAGER - - - 207 - NOT REQUIRED REQUIRED INTERIOR - REMAINS, VERIFY OPERATION & CODE COMPLIANCE* DOOR SCHEDULE EX DOOR / CASED OPENING FRAME PAYROLL OFFICE GENERAL OFFICE VESTIBULE *CONTRACTOR TO VERIFY OPERATION AND COMPLIANCE OF EXISTING DOORS TO BE REUSED, AND VERIFY DIMENSIONS PRIOR TO APPROVAL OF SHOP DRAWINGS / R.O. FOR HOST WALLS EXIST INTERIOR - 1 3/4" METAL DOOR WITH TEMPERED GLASS WINDOW HM H2 EX PT-3 H1 EXISTING DOOR TO REMAIN, 3'-0" X 7'-0" (VIF) 208 209 210 WD WD EX REMOVE AND RETAIN, VERIFY OPERATION & CODE COMPLIANCE* F D D NEW WOOD DOOR, 3'-0" X 7'-0" WITH A 24" X 32" LITE EXIST EX'G WD DOOR, 3'-0" X 7'-0" WITH A 24" X 32" LITE (VIF) 206 VESTIBULE EXIST F EX'G WOOD DOOR, 3'-0" X 7'-0" (VIF) WD 45.0° 6" 1 1/2" 2'-0" 2'-0" 2'-10" 4" DOOR 6" 1 3/4" 4" 1'-0" AC-01 2'-10" EQ EQ EQ EQ 9'-8" VIF 3'-0" 1'-6" 2'-6" EQ EQ EQ EQ 4'-0" 3'-9" 3'-6" 7'-3" 2'-2" 1 3/4" 8" 1'-0" 2'-0" 3/4" 6" 1'-0" 1 1/2" 2'-0" 2'-0" 2'-10" 4" 6" 1 3/4" 4" 1'-0" DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 A9.0 PARTITION AND MILLWORK GN-1 GENERAL NOTES DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 06-28-21 07-09-21 GN-2 GENERAL NOTES DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 06-28-21 07-09-21 E001 DOOR ALARM CONTROL PANEL DACP HINGE SIDE PLUNGER SWITCH DC FIRE PROTECTION SYMBOLS FIRE ALARM CONTROL PANEL FACP FIRE PULL BOX F HORN/STROBE ALARM COMBO STROBE S FLOW SWITCH FS PIV TAMPER SWITCH TS HORN/STROBE ALARM COMBO WEATHER PROOF HOOD ANSUL SYSTEM CONNECTION A SMOKE DETECTOR S DUCT SMOKE DETECTOR S HEAT DETECTOR H SD MAGNETIC LOCK WITH KEY PAD MAGNETIC LOCK WITH CARD READER HS KP CR CARBON MONOXIDE DETECTOR CO ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS OF EQUAL EQUIPMENT AND MATERIALS AGAINST THE BASIS OF DESIGN. SUBSTITUTE ITEMS WILL BE COMPARED AGAINST DESIGN BASIS DURING SUBMITTAL PROCESS. ENGINEER RESERVES THE RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN DESIGN BASIS.. 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL SWITCH GEAR, LOAD CENTERS AND PANEL BOARDS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME AND PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER DESIGN BASIS OR APPROVED EQUAL. ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM FOUND NOT EQUAL TO THE SPECIFIED ITEM AS DESIGNED. 3. CONTRACTOR SHALL FURNISH A TEMPORARY SERVICE FOR THE USE OF ALL TRADES DURING CONSTRUCTION AS REQUIRED BY THE GENERAL CONTRACTOR. REMOVE ALL TEMPORARY EQUIPMENT AS PERMANENT SERVICES BECOME AVAILABLE. 4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. MODIFICATIONS IN ELECTRICAL SYSTEM ROUTING AND LOCATIONS AS REQUIRED TO MEET THE INTENT, SHALL BE PERFORMED WITHOUT ADDITIONAL COST TO OWNER. SECURE AND PAY FOR ALL REQUIRED PERMITS. 5. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND +42" +42" A:1 A:1 A:1 A:1 A:1 A:1 A:3 A:3 A:3 A:5 A:5 A:5 A:10 A:10 A:10 A:7 A:7 A:9 A:9 A:9 A:9 FLR FLR FLR FLR A:2 A:4 A:6 A:8 6 8 10 11 J K H J K H 6 8 10 11 J K H 6 8 10 11 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L2 L2 EM EM OS OS OS OS OS OS EXC L2 L2 DN EM EM EM EM EM L2 L2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 $LV1 OS EXC EXC $LV1 OS PP OS OS OS PP $OSD $OSD L2 L2 L2 L2 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 OS L2 L2 L2 14.9 20.3 29.4 41.3 58.7 55.1 43.0 42.7 47.8 51.6 48.4 42.7 41.5 45.5 47.2 16.4 22.6 33.8 48.2 57.7 56.2 49.0 48.7 56.1 61.1 57.3 49.2 47.9 53.8 57.3 50.4 36.6 25.3 17.8 24.0 34.6 48.0 56.4 55.3 49.9 49.8 56.4 60.7 57.1 50.2 49.1 53.9 56.4 49.7 37.1 26.6 19.0 24.8 34.4 46.0 53.6 53.0 49.0 49.0 54.2 57.9 54.9 49.4 48.2 51.6 52.9 46.9 36.3 27.1 20.6 26.4 36.5 49.7 58.2 56.6 50.6 50.6 57.4 62.2 58.3 51.2 49.9 54.4 56.3 49.6 37.7 27.9 23.1 29.8 40.0 55.0 64.4 61.8 53.3 52.9 62.0 68.1 63.5 53.8 52.3 58.6 61.7 54.0 39.9 28.7 13.0 18.2 24.2 28.6 29.3 27.1 27.0 28.6 29.2 33.3 41.6 54.3 62.6 59.9 52.7 52.5 60.2 65.6 61.2 52.9 51.4 56.5 58.9 51.9 38.9 28.6 15.9 23.5 33.3 39.7 39.6 35.5 34.2 36.1 37.7 39.0 43.9 52.8 58.6 56.9 51.3 51.2 57.0 60.9 57.7 51.3 49.9 53.2 54.5 48.2 37.4 28.2 17.4 26.9 40.0 48.5 46.7 43.0 43.0 47.9 49.7 47.3 48.8 56.7 62.7 59.5 53.0 52.6 59.4 64.1 60.0 52.6 51.0 55.3 57.3 50.4 38.5 28.6 16.4 25.2 37.0 44.6 44.1 43.7 48.4 57.4 59.9 54.2 53.5 62.3 68.5 64.4 55.1 54.6 63.5 69.3 64.5 54.7 53.0 59.2 62.4 54.5 40.2 29.1 48.3 56.9 59.7 54.7 54.2 61.1 66.1 62.0 54.3 53.7 61.2 66.6 62.0 53.5 51.8 56.9 59.3 52.1 39.2 28.8 42.1 52.2 57.1 53.4 52.8 57.8 61.1 58.3 52.6 52.2 57.7 61.3 57.9 51.7 50.1 53.2 54.4 48.2 37.4 28.2 45.4 56.1 60.1 55.9 54.2 60.0 63.5 60.3 53.9 53.4 59.7 64.3 60.0 52.6 50.9 55.1 57.0 50.2 38.2 28.4 48.8 61.1 65.2 57.8 54.3 62.1 68.2 63.9 56.0 55.3 63.5 68.9 64.3 54.2 52.6 58.6 61.8 54.0 39.8 28.7 48.4 60.0 63.9 50.7 48.8 52.6 64.1 61.3 54.8 54.3 60.9 65.6 60.9 52.5 51.0 56.0 58.3 51.1 38.3 28.0 56.4 57.6 53.4 52.5 56.8 59.8 56.2 50.1 48.7 51.9 53.0 46.8 36.1 27.0 55.9 58.8 54.8 53.5 58.0 60.9 57.1 50.5 48.9 53.1 54.7 48.0 36.2 26.6 MP001 MECHANICAL SPECIFICATIONS GENERAL 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS OF EQUAL EQUIPMENT AND MATERIALS AGAINST THE BASIS OF DESIGN. SUBSTITUTE ITEMS WILL BE COMPARED AGAINST DESIGN BASIS DURING SUBMITTAL PROCESS. ENGINEER RESERVES THE RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN DESIGN BASIS. 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL DUCT ACCESSORIES, INSULATION, VAV BOXES, REGISTERS, GRILLES, DIFFUSERS AND LOUVERS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME, PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER DESIGN BASIS OR APPROVED EQUAL. ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM. 3. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL REQUIRED ELECTRICAL SUPPORT NEEDED FROM THE ELECTRICAL CONTRACTOR. ENSURE ALL SUBMITTALS FOR POWERED COMPONENTS AND CONTROLS ARE PROVIDED AND FULLY COORDINATED WITH ELECTRICAL CONTRACTORS. 4. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE TO EXAMINE ALL CONDITIONS THAT MAY IN ANY WAY AFFECT THE EXECUTION OF HIS WORK. HE SHALL ALSO EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR OTHER BRANCHES OF WORK MAKING REFERENCE TO THEM FOR DETAILS OF EXISTING BUILDING CONDITIONS. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO INCLUDE ALL REQUIRED WORK IN THE BID. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 5. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. M.C. SHALL PROVIDE AND PAY FOR ALL REQUIRED PERMITS. 6. PRIOR TO WORK COORDINATE ALL OPENINGS AND INSTALLATIONS OF DUCT, PIPING, EQUIPMENT, CONTROLS, DIFFUSERS AND GRILLES WITH G.C. AND OTHER TRADES. PROVIDE INSTALLATIONS WITH PROPER MANUFACTURERS RECOMMENDED CLEARANCES. 7. UPON COMPLETION OF THE MECHANICAL SK S-2 200 S-2 200 S-3 240 S-3 240 S-3 240 S-3 240 S-1 100 S-1 100 S-1 100 S-1 100 S-1 100 S-3 240 8"Ø 10"Ø 10"Ø 10"Ø 10"Ø 10"Ø 6"Ø 6"Ø 6"Ø 6"Ø 6"Ø 20/14 18/14 14"Ø 12"Ø 12"Ø 8"Ø 20/16 EXISTING S/A DUCT SERVING SPACE NOT IN CONTRACT EXISTING R/A DUCT R-1 R-2 R-1 10"Ø 6"Ø 18"Ø 12"Ø IMB 6 8 10 11 J K H J K H 6 8 10 11 EXISTING S/A DUCT SERVING SPACE NOT IN CONTRACT EXISTING R/A DUCT MP100 HVAC AND PLUMBING PLANS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 210519 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p MEP Consulting Engineers 262 Tradewinds Drive Santa Rosa Beach Florida 32459 317.506.8151 dave@gnaengineering.com GOODERUM & ASSOCIATES ENGINEERING P: E: 874 Cheltenham Drive Avon IN, 46123 South Office North Office 07-09-2021 J E F F R E Y M . P E R K E Y 07-09-2021 07-09-2021 2 SCALE: 1/8" = 1'-0" HVAC AND PLUMBING PLAN 1. ROUTE 1/2" CW LINE FROM NEW CW LINE SERVING NEW SINK TO ICE MAKER BOX. 2. ROUTE NEW 1-1/2" SANITARY LINE DOWN FROM NEW SINK TO 1ST FLOOR INTERSTITIAL SPACE. ROUTE NEW LINE WEST IN INTERSTITIAL SPACE, THROUGH WIDE FLANGE BEAM ABOVE REFRESHMENT AREA, AND TO EXISTING SANITARY LINE 3" OR LARGER BEHIND DRINKING FOUNTAIN. ROUTE NEW 1-1/2" VENT LINE FROM NEW SINK TO EXISTING VENT LINE 2" OR LARGER. 3. ROUTE NEW 1/2" CW AND 1/2" HW LINES TO NEW SINK FROM RESTROOM AREA ON FIRST FLOOR TO WHICH THE SANITARY LINE IS ROUTED. 4. REMOVE SPIRAL DUCT BACK TO RECTANGULAR DUCT SECTION. 5. TRANSITION FROM EXISTING DUCT TO NEW DUCT WORK AT THIS POINT. 6. EXISTING S/A DUCT SERVING OFFICE NOT IN CONTRACT IS EXISTING TO REMAIN. 7. CONNECT EXISTING DUCT TO NEW DUCT WORK AND ADD MANUAL VOLUME DAMPER AS SHOWN. KEY NOTES: 1. REFERENCE SHEET MP001 FOR ABBREVIATIONS, SYMBOLS, SPECIFICATIONS AND SCHEDULES. 2. DEMOLITION PLANS ARE DIAGRAMMATIC AND BASED ON LIMITED SURVEY DATA. HVAC CONTRACTOR SHALL VISIT SITE, EXAMINE ALL PLANS AND DETERMINE EXISTING ELEMENTS TO REMAIN AND EXISTING TO BE REMOVED AS NEEDED TO MEET DESIGN INTENT. HVAC CONTRACTOR SHALL RECOVER ALL REFRIGERANTS AND DISPOSE OF ALL HVAC SYSTEMS PER EPA REQUIREMENTS. HVAC CONTRACTOR SHALL MAP OUT EXISTING DUCTWORK TO REMAIN, SEAL AND INSULATE PER SPECIFICATIONS AND REMOVE ALL UNUSED BRANCHES. 3. EXISTING HVAC UNIT WAS MANUFACTURED IN 2014. HVAC CONTRACTOR SHALL VERIFY EXISTING UNIT IS FUNCTIONING PROPERLY, CHANGE FILTERS, AND REPORT ALL DEFICIENCIES TO G.C. GENERAL NOTES: # 1 SCALE: 1/8" = 1'-0" HVAC DEMOLITION PLAN 3 4 5 2 6 7 SANITARY ISOMETRIC C SCALE: NONE SAN SK 1-1/2" 1-1/2" V 2 2 1 KEY PLAN SCALE: NONE LAY-IN DIFFUSER DETAIL A SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER ELBOW FITTING WITH DRAWBANDS. SHEET METAL ELBOW SEAL ALL RIBS AND CONNECTION TO DIFFUSER NECK SUPPLY DIFFUSER ACT CEILING FLEX DUCT MAXIMUM LENGTH SHALL NOT EXCEED 7'-0" REFERENCE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN AND COORDINATE INSTALLATION WITH ALL CEILING ELEMENTS. 30° MAX O CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. ECCENTRIC TRANSITION MAX, 30 DEG. 30° MAX NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). WHERE "R" IS EQUAL TO OR GREATER THAN "A" MINIMUM RADIUS (R) = 4 INCHES. R=A A DUCT CONSTRUCTION DETAILS B 45 DEG. OCL CONNECTION TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED RECTANGULAR DUCT BRANCH AIR FLOW V.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY SEALED ROUND SHEET METAL DUCT TO DIFFUSER 11 8" NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE-OFF. AIR FLOW SCALE: NONE SCALE: NONE INSTALLATION, DEMONSTRATE TO THE ENGINEER AND THE OWNER'S SATISFACTION THAT THE SYSTEMS HAVE BEEN INSTALLED IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND APPLICABLE CODES. DEMONSTRATE THE DYNAMIC OPERATION OF EACH SYSTEM. VERIFY PROPER OPERATION OF EQUIPMENT, FILTERS ARE CLEAN AND COMPONENTS OF THE SYSTEM ARE INSTALLED AND ADJUSTED IN FULL ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 8. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE), INDIANA ENERGY CODE (ASHRAE 90.1-2007) PERTINENT STATE, COUNTY, CITY CODES AND ORDINANCES AND INDIANA AMENDMENTS. 9. MECHANICAL CONTRACTOR SHALL ENSURE EMPLOYEES ARE MEETING AND DOCUMENTING ALL OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS REQUIRED BY LAW AND BY CONTRACT. PERSONAL PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND UTILIZED AS REQUIRED. MECHANICAL CONTRACTOR SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE TO COMPLY WITH OSHA REQUIREMENTS. 10. INSTALL ALL EQUIPMENT, DUCTWORK AND PIPING AS HIGH AS POSSIBLE. PRIOR TO ROUGH-IN COORDINATE ELEVATIONS WITH OTHER TRADES. WHERE VISIBLE, ORIENT PERPENDICULAR AND/OR PARALLEL TO STRUCTURE. EQUIPMENT 1. PROVIDE EQUIPMENT AS SHOWN ON EQUIPMENT SCHEDULES AND PLAN NOTES. SUBSTITUTIONS TO LISTED EQUIPMENT SHALL BE AT RISK OF CONTRACTOR. SUBSTITUTIONS SHALL ONLY BE ALLOWED IF ITEMS ARE EQUAL IN ALL ASPECTS. 2. PROVIDE SUBMITTALS TO ELECTRICIAN AS REQUIRED FOR COORDINATION OF ALL ELECTRICAL POWER WIRING. INCLUDE WIRING DIAGRAMS AND CABLING REQUIREMENTS FOR REFERENCE. COORDINATE ALL INTERLOCKS AS NEEDED. PROVIDE SINGLE POINT CONNECTION KITS AS NEEDED. 3. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND CLEARANCE REQUIREMENTS. PROVIDE ALL REQUIRED MOUNTING OR HOUSEKEEPING PADS. G.C. SHALL PROVIDE LEVEL GRADE FOR EXTERIOR MOUNTED EQUIPMENT. M.C. SHALL PROVIDE ALL HOISTING AND RIGGING NEEDED TO SET ALL HVAC EQUIPMENT. 4. ALL EQUIPMENT SHALL BE INSTALLED AS NEEDED TO PREVENT OBJECTIONABLE NOISE AND/OR VIBRATION. M.C. SHALL PROVIDE VIBRATION PADS, SPRING ISOLATORS, ATTENUATORS AND ACCESSORIES AS NEEDED. DUCTWORK 1. CONCEALED ROUND DUCTWORK SHALL BE CONSTRUCTED PER SMACNA LOW PRESSURE STANDARDS 1" PRESSURE CLASS, 5' MAXIMUM JOINT LENGTHS, SEAL CLASS B LONGITUDINAL SEAM SNAP LOCK PIPE AND ADJUSTABLE FITTINGS. 2. EXPOSED ROUND DUCTWORK (OR WHERE SPIRAL IS INDICATED ON THE PLANS) SHALL BE LINDAB OR EQUAL GALVANIZED STEEL CONFORMING TO ASTM STANDARDS A653 AND A924 GASKETED SPIRAL DUCTING WITH NO SEALER. EDPM RUBBER GASKET SHALL BE U.L. CLASSIFIED RATING OF FLAME SPREAD 0 AND SMOKE DEVELOPED 5 IN ACCORDANCE WITH ASTM STANDARD E84-91A SMACNA LEAKAGE CLASS 3. FITTINGS SHALL BE MANUFACTURED USING ONE OR MORE OF THE FOLLOWING CONSTRUCTION METHODS: OVERLAPPED EDGES STITCH WELDED ALONG THE ENTIRE LENGTH OF THE FITTING, STANDING SEAM GORE LOCKED AND INTERNALLY SEALED, BUTTON PUNCHED AND INTERNALLY SEALED. ELBOWS 3-INCH THROUGH 12-INCH DIAMETER WILL BE DIE STAMPED AND CONTINUOUSLY STITCH WELDED. 3. PROVIDE SHEET METAL 90 FOR ALL TURNS GREATER THAN 45 DEGREES. DO NOT USE FLEXIBLE DUCT FOR CHANGES IN DIRECTION GREATER THAN 45 DEGREES. 4. PROVIDE MANUAL BALANCING DAMPERS FOR ALL SUPPLY AIR RUNS. ROUND DAMPERS SHALL BE SECURED ON BOTH SIDES OF DUCT AND SHALL CONTAIN LOCKING HANDLE. SPIRAL DUCTS SHALL USE SPIRAL STYLE DAMPERS WITH FULL WIDTH SHAFTS AND NYLON BEARINGS AT EACH END. RECTANGULAR DUCTS SHALL USE MULTI OR SINGLE BLADE WELDED FRAMED DAMPERS WITH JACK SHAFTS AND LOCKING HANDLE. INSTALL NYLON RIBBON ON ALL DAMPER HANDLES LOCATED IN INSULATED DUCTING. DO NOT INSTALL DAMPERS IN NON ACCESSIBLE LOCATIONS. PROVIDE INTEGRAL DAMPERS WITH DIFFUSER IN NECK IF NO ACCESSIBLE LOCATION IS POSSIBLE. ALL SUPPLY AIR RUNS SHALL HAVE MEANS OF BALANCE. RETURN AND EXHAUST AIR RUNS SHALL CONTAIN DAMPERS WHERE SHOWN ON PLANS. 5. INSULATED FLEXIBLE DUCTING SHALL NOT EXCEED 25 FEET. ALL FLEX SHALL BE LISTED FLEXIBLE DUCT, FLEXIBLE CONNECTORS ARE NOT ACCEPTABLE. FLEXIBLE DUCT EQUAL TO FLEXIBLE DUCT CLASS 1 AIR DUCT, DOUBLE LAMINATED POLYESTER FILM ON STEEL WIRE REINFORCING, INSULATED WITH SCRIM REINFORCED METALIZED POLYESTER OUTER FIRE RETARDANT JACKET. R-4.2 FOR CONDITIONED SPACES AND R-6.0 FOR ANY SPACES OUTSIDE BUILDING THERMAL ENVELOPE. FLEX DUCTS SHALL NOT BE RUN THROUGH WALLS OR FLOORS. PROVIDE HARD DUCTED SLEEVES AS NEEDED. 6. RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT STANDARDS, +/- 1.0" W.C. FROM ASTM A 653/A 653M G-90 COATED GALVANIZED SHEET STEEL. SEAMS SHALL BE PITTSBURGH CONSTRUCTION, NO BUTTON PUNCH OR SNAP LOCK SEAMS ARE ACCEPTABLE. SEAL ALL TRANSVERSE AND LONGITUDINAL SEAMS WITH WATER BASED DUCT SEALER, SEAL CLASS B. GAUGE AND JOINT CLASSIFICATIONS ACCEPTABLE ARE AS FOLLOWS, ALL SECTION LENGTHS ARE 48" MAXIMUM, REFER TO SMACNA RIGIDITY TABLES FOR GAUGES ON LONGER SECTIONS IF REQUIRED: < 12" 26 GAUGE, FLAT S AND DRIVE 12"-24" 24 GAUGE, FLAT S AND DRIVE 25"-34" 22 GAUGE, STANDING S AND FLAT DRIVE 34"-40" 22 GAUGE, STANDING S AND STANDING DRIVE >40" REFER TO SMACNA FOR STANDARDS. 2. DUCT HANGERS: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," CHAPTER 5, "HANGERS AND SUPPORTS." PROVIDE GALVANIZED MINIMUM 22 GAUGE 1" WIDE STRAP TO HANG RECTANGULAR DUCTWORK SMALLER THAN 30" WIDE. DUCT HANGERS FOR RECTANGULAR SHEET METAL DUCTS 30" AND LARGER SHALL BE TRAPEZE STYLE USING UNI-STRUT AND 3/8" OR 1/2" ROD. PROVIDE GRIPPLE, DURODYNE OR EQUAL CABLE HANGERS FOR HANGING ROUND DUCTWORK. SUPPORT ALL HANGERS FROM STRUCTURE PER SMACNA STANDARDS.HANGERS FOR SPIRAL DUCTS GREATER THAN 28" IN DIAMETER SHALL BE HUNG WITH ROD AND DUCT CLAMP. FLEXIBLE DUCTING SHALL BE SUPPORTED USING MINIMUM 2" WIDE NYLON STRAP. ALL INTERVALS ARE PER SMACNA. 3. FOR ALL RETURN AIR, PROVIDE OPENINGS, PATHWAYS, TRANSFERS, COORDINATE UNDERCUTS, ETC. AS REQUIRED TO RETURN AIR SUPPLIED TO SPACES BACK TO AIR HANDLING UNIT. DUCT ACCESSORIES 1. COORDINATE WITH ARCHITECTURAL DRAWINGS AND PROVIDE FIRE AND FIRE AND SMOKE DAMPERS AT FIRE RATED ASSEMBLY PENETRATIONS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE AND WHERE SHOWN ON PLANS. 2. PROVIDE FLASHING MATERIALS AND OR SLEEVES AS REQUIRED FOR ALL DUCT PENETRATIONS OF NON RATED ELEMENTS. EXPOSED PENETRATIONS SHALL BE FLASHED WITH SHEET METAL TIGHT TO WALLS. 3. PROVIDE HIGH EFFICIENCY TAKE OFFS, PEAL AND STICK STYLE ATTACHED TO RECTANGULAR DUCTING WITH SHEET METAL SCREWS FOR ALL ROUND SUPPLY AIR TAKE OFFS AND SADDLES. 4. REGISTERS, GRILLES AND DIFFUSERS SHALL BE EQUIVALENT TO SCHEDULED PRODUCTS. SUBSTITUTION OF RESIDENTIAL STAMPED STYLE PRODUCTS FOR COMMERCIAL PRODUCTS WILL NOT BE ACCEPTED. DUCT INSULATION 1. ALL DUCT INSULATION MATERIALS SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. DUCT WRAP SHALL BE FIBERGLASS MATERIAL PER ASTM C-411,ASTM C-1104,ASTM C665, ASTM C-1338, ASTM E-84, UL723, NFPA 90A,CAN/ULC S102-1188,ASTM C1290, ASTM C553, ASTM C1136. 2. INSULATION: INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED. UNLESS OTHERWISE NOTED ON PLANS DUCTWORK SHALL BE INSULATED AS FOLLOWS: SA- 1-1/2" FIBERGLASS DUCT WRAP WITH FSK FACING, 75 #/FT3 MINIMUM APPLIED R-3.5. RA NONE REQUIRED UNLESS NOTED ON PLANS. SA/RA IN UNCONDITIONED OR ATTIC SPACES OUTSIDE THE BUILDING INSULATION ENVELOPE; 2" MINIMUM 75 #/FT3, R-6 AS APPLIED FSK DUCT WRAP. SA/RA- IN RETURN AIR PLENUMS OR CONDITIONED SPACES WHERE NOT CONCEALED BY DRYWALL CEILING OR BULKHEAD CONSTRUCTION WITHIN THE BUILDING INSULATION LINE NONE REQUIRED. PIPING 1. PIPING SLEEVES; INTERIOR OR EXTERIOR ABOVE GRADE; GALVANIZED-STEEL-PIPE SLEEVES OR PVC-PIPE SLEEVES. VERIFY, WITH FIRE AUTHORITIES HAVING JURISDICTION, THAT PVC MATERIALS ARE ALLOWED FOR SLEEVES. BELOW GRADE; ALL; MECHANICAL GALVANIZED-STEEL PIPE SLEEVE SYSTEM LIKE LINK-SEAL. ALL SLEEVES SHALL BE FIRE STOPPED OR CAULKED. EXTERIOR SLEEVES SHALL PROVIDE WATER/AIR TIGHT PENETRATION SYSTEM. FIRE STOPPING. 1. FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE WITH SECTIONS 714 AND 717 OF THE IBC AND SECTION 607 OF THE IMC. 2. CONTRACTOR SHALL MAKE REFERENCE TO ARCHITECTURAL PLANS AND PROVIDE ALL REQUIRED FIRE STOPPING. 3. CONTRACTOR SHALL PROVIDE AHJ WITH FULL SUBMITTAL INDICATING METHODS OF CONSTRUCTION AND UL LISTINGS FOR EACH PENETRATION SYSTEM USED. 4. DUCTS AND AIR TRANSFER OPENING PENETRATIONS OF ASSEMBLIES REQUIRED TO BE PROTECTED AND IN NON FIRE-RESISTANCE-RATED FLOORS SHALL COMPLY WITH SECTIONS 717. 5. FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS LOCATED WITHIN AIR DISTRIBUTION AND SMOKE CONTROL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 607 OF THE IMC. AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND LISTING. 6. ACCESS DOORS SHALL BE PERMITTED IN CEILINGS OF FIRE-RESISTANCE-RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES PROVIDED SUCH DOORS ARE TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND LABELED BY AN APPROVED AGENCY FOR SUCH PURPOSE. ALL ACCESS DOORS SHALL BE PROVIDED BY TRADE MAKING PENETRATIONS. CHECK TEST AND START UP REQUIREMENTS 1. ALL HVAC EQUIPMENT INSTALLATIONS SHALL BE VERIFIED AND STARTED UP PER MANUFACTURERS RECOMMENDATIONS. VERIFY ALL MODES OF OPERATION. CONFIGURE ALL CONTROLS AND PROGRAM OCCUPANCIES PER OWNER PROVIDED SCHEDULES. 2. PROVIDE AIR BALANCE BY CONTRACTOR. CONTRACTOR SHALL BALANCE SUPPLY, RETURN, OUTSIDE, RELIEF AND EXHAUST AIR SYSTEMS IN ACCORDANCE WITH CURRENT SMACNA, NEEB OR AABC STANDARDS TO DESIGN VALUES AND PROVIDE WRITTEN REPORT TO ARCHITECT. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL DEVICES, DRIVES, SHEAVES, MOTOR CHANGES AND REWORK AS REQUIRED TO MEET DESIGN REQUIREMENTS. 3. TEMPERATURE CONTROL WORK SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR. PROVIDE ALL COMPONENTS INCLUDING T/S, T/S WIRE (PLENUM RATED IN RA PLENUMS), SWITCHES, ACTUATORS ETC. AS REQUIRED FOR A COMPLETE SYSTEM. PRIOR TO ROUGH-IN COORDINATE FINAL LOCATION FOR ALL CONTROLS WITH OWNERS REPRESENTATIVE. 4. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS, AIR BALANCE REPORT AND AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL MANUFACTURERS WARRANTED EQUIPMENT. SYMBOLS ABBREVIATIONS AFF ABOVE FINISHED FLOOR ACCU AIR COOLED CONDENSING UNIT AHU AIR HANDLING UNIT AWH ARCHITECTURAL WALL HEATER BDD BACK DRAFT DAMPER BOD BOTTOM OF DUCT BOB BOTTOM OF BEAM BTUH BRITISH THERMAL UNIT PER HOUR CFM CUBIC FEET PER MINUTE CWH COMMERCIAL WALL HEATER DEG F DEGREES FARENHEIT DB DRY BULB Ø ROUND DUCT EA EACH OR EXHAUST AIR EG EXHAUST GRILLE EADB ENTERING AIR DRY BULB EAWB ENTERING AIR WET BULB EC ELECTRICAL CONTRACTOR ECH ELECTRIC CEILING HEATER EF EXHAUST FAN ESP EXTERNAL STATIC PRESSURE " W.C. EUH ELECTRIC UNIT HEATER EWH ELECTRIC WALL HEATER F FURNACE FC FAN COIL FD FIRE DAMPER FD/SD FIRE AND SMOKE DAMPER FPM FEET PER MINUTE FPVAV FAN POWERED VAV FT FEET FSK FOIL SCRIM VAPOR BARRIER GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE GUH GAS UNIT HEATER HD HOOD HP HEAT PUMP OR HORSE POWER IN INCHES IR INFRA RED LAT LEAVING AIR TEMPERATURE LS LINEAR SLOT DIFFUSER MAN MANUAL MBH 1000 BTUH MC MECHANICAL CONTRACTOR MCC MOTOR CONTROL CENTER MFR MANUFACTURER MUA MAKE UP AIR OA OUTSIDE AIR PC PLUMBING CONTRACTOR DHU DEHUMIDIFICATION UNIT PRV PRESSURE RELIEF VALVE PSI POUNDS PER SQUARE INCH PTAC PACKAGED TERMINAL AIR CONDITIONER RA RETURN AIR RJ ROOF JACK RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR TCC TEMPERATURE CONTROL CONTRACTOR TSP TOTAL STATIC PRESSURE UON UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME WC WALL CAP WIC WALK IN COOLER WIF WALK IN FREEZER AIR COOLED CONDENSING UNIT MANUAL VOLUME DAMPER LOCKING WITH SHAFT FIRE DAMPER ROUND MOTORIZED DAMPER M COMBINATION FIRE/SMOKE DAMPER THERMOSTAT EXHAUST GRILLE ROOF EXHAUST FAN TURNING VANES DOUBLE THICKNESS XXX X-# FD FD SD ROOF TOP UNIT W/D W/D HORIZONTAL FURNACE OR FC WITH SECONDARY DRAIN PAN HORIZONTAL AIR COOLED CONDENSING UNIT WALL MOUNTED EXHAUST FAN SUPPLY AIR DIFFUSER RETURN AIR REGISTER OR GRILLE ROUND DIFFUSER LINEAR OR SLOT DIFFUSER CEILING MOUNTED EXHAUST FAN ACCU FC F AC DIRECT DUCT MOUNTED REGISTER DIFFUSER TAG EWH ELECTRIC WALL HEATER SQUARE TO ROUND TRANSITION SHEET METAL DUCT WIDTH BY DEPTH LINED SHEET METAL DUCT FREE AREA WIDTH BY DEPTH. ACCESS DOOR SQUARE SHEET METAL 90 PROVIDE WITH DOUBLE THICKNESS TURNING VANES. RADIUS SHEET METAL 90, R=1.5*D ROUND BRANCH DUCT SADDLE ON ROUND DUCT. 45 DEG BRANCH DUCT TAKE OFF ON RECTANGULAR. STRAIGHT ROUND TAP BRANCH DUCT TAKE OFF. M RECTANGULAR MOTORIZED DAMPER BOOT MOUNTED REGISTER MARK CFM T OR AIR COOLED HEAT PUMP HP EF VERTICAL FURNACE OR FC RADIANT FIRE DAMPER RFD THERMOSTAT IN LOCK BOX SENSORS, TEMPERATURE, HUMIDITY CARBON MONOXIDE SENSOR CARBON DIOXIDE SENSOR NITROGEN OXIDE SENSOR NO CO2 CO S T DUCT SMOKE DETECTOR SD H MOTOR CONTROL CENTER MCC ACCESS DOOR HVAC AND PLUMBING ABBREVIATIONS, SYMBOLS, SPECIFICATIONS, & SCHEDULES DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 210519 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p MEP Consulting Engineers 262 Tradewinds Drive Santa Rosa Beach Florida 32459 317.506.8151 dave@gnaengineering.com GOODERUM & ASSOCIATES ENGINEERING P: E: 874 Cheltenham Drive Avon IN, 46123 South Office North Office 07-09-2021 J E F F R E Y M . P E R K E Y 07-09-2021 07-09-2021 1. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL PLUMBING FIXTURES, VALVES, DRAINS, CLEAN OUTS, PIPING, PIPING ACCESSORIES, INSULATION AND PIPING HANGERS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME, PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT.ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM. 2. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUIRED, WHEN SUCH ADJUSTMENTS ARE NECESSARY FOR PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 3. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE W/ INDIANA AMENDMENTS), 2007 ASHRAE 90.1 INDIANA ENERGY CODE 2010, PERTINENT STATE, COUNTY, CITY CODES AND ORDINANCES WITH INDIANA AMENDMENTS. 4. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 5. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 6. PLUMBING CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL PLUMBING ROUGH-INS, 7. PIPING TYPES UNLESS OTHERWISE NOTED ON PLANS: WATER WATER TUBING SHALL BE TYPE A PEX WIRSBO, ZURN, NIBCO, OR UPONOR CONFORMING TO ASTM F876, F877, E84, E814, ANSI/UL 263 AND NSF14/61. 100 PSIG AT 180 DEG. BLUE FOR COLD AND RED FOR HOT AND RE-CIRCULATION WHITE FOR GENERIC. FITTINGS SHALL BE PER ASTM F1960 LIKE UPONOR ProPEX COLD EXPANSION, PRESS FIT MECHANICAL JOINTS PER ASTM F2854 OR COPPER CRIMP WITH BRASS OR ENGINEERED PLASTIC FITTINGS. MANIFOLDS WHERE USED SHALL BE LIKE UPONOR ProPEX TYPE L TO ASTM F877 WITH BRASS OR EP BALL VALVES. SEWER/VENT POLYVINYL CHLORIDE SEWER PIPE (PVC): ASTM D2665, ASTM F 1866 SCHEDULE 40 SOLID CORE DRAIN WASTE AND VENT WITH PVC SOCKET WELDED FITTINGS DESIGNED TO FIT PIPING DIAMETERS. ALL PIPING IN RETURN AIR PLENUMS SHALL CONFORM TO REQUIREMENTS FOR PLENUM MATERIALS. 8. DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A-234 9. UNLESS OTHERWISE NOTED, ROUTE ALL PIPING AS HIGH AS POSSIBLE AND ROUTE PERPENDICULAR AND/OR PARALLEL TO BUILDING STRUCTURE. PLUMBING SPECIFICATIONS 58.4 61.6 56.4 54.0 59.7 63.9 59.6 51.3 49.6 55.1 57.8 50.5 36.7 25.8 51.5 55.3 50.8 49.1 53.8 57.5 57.3 50.8 45.2 49.4 51.5 44.9 33.0 23.3 24.2 32.0 38.2 39.4 35.9 36.4 40.4 43.4 42.6 39.2 38.2 40.7 43.2 42.0 38.8 38.1 46.5 65.7 43.3 50.6 54.4 57.3 37.9 34.1 28.0 31.9 43.4 52.0 52.1 47.5 46.3 51.9 57.5 55.5 49.2 47.1 52.1 57.2 55.1 48.7 47.0 52.6 59.1 59.6 55.2 54.2 58.6 61.2 48.9 38.3 37.0 51.6 62.7 62.7 55.8 54.0 61.4 68.5 65.8 57.1 54.2 61.0 67.8 65.1 56.5 53.6 61.3 69.4 67.7 59.6 57.1 63.0 68.2 59.9 45.1 39.4 53.9 65.9 65.5 59.4 57.7 64.4 71.0 68.4 60.0 57.1 63.3 69.5 67.0 59.3 57.0 63.1 70.2 68.6 60.3 57.3 62.7 67.6 61.2 46.9 40.9 57.1 69.3 68.6 62.1 60.1 67.1 73.7 70.7 61.9 58.3 64.1 69.8 67.6 61.3 58.2 64.0 71.8 69.6 60.1 56.5 61.9 66.8 61.2 47.4 41.9 60.9 72.4 71.3 63.7 61.5 69.3 76.2 72.5 62.4 57.5 61.7 67.1 65.1 58.7 56.0 61.8 70.3 66.9 57.0 53.3 59.2 64.6 59.0 45.6 30.3 41.6 52.3 55.5 50.9 31.2 29.3 47.7 59.8 69.9 69.0 62.2 60.4 66.9 73.1 69.5 59.2 45.5 50.3 55.5 54.0 48.8 47.2 52.0 57.3 54.8 48.0 45.5 49.4 53.1 48.6 37.5 24.6 32.9 43.2 52.4 57.7 54.5 49.3 51.2 59.3 68.6 67.3 60.6 58.8 65.1 71.2 66.4 49.7 20.0 26.4 37.1 50.0 58.5 57.0 50.7 49.3 58.3 66.7 65.5 58.8 55.5 61.6 66.3 61.3 47.4 16.6 21.4 30.2 40.1 47.8 47.7 43.3 42.5 48.4 54.7 59.5 71.3 47.9 50.2 53.2 48.7 39.1 OFFICE ADDITION 205 37.2 48.5 56.5 59.4 58.9 54.7 45.3 34.2 46.3 61.3 71.8 75.5 75.0 69.4 56.9 42.0 51.5 69.1 81.4 85.5 84.9 78.6 63.9 46.4 51.3 68.9 81.1 85.2 84.6 78.3 63.7 46.3 45.8 60.5 70.9 74.6 74.0 68.5 56.2 41.5 36.7 47.6 55.4 58.2 57.8 53.6 44.5 33.6 25.3 31.9 34.0 30.4 30.9 20.7 33.2 44.0 47.9 41.1 29.4 20.3 38.6 51.7 56.6 47.9 33.6 22.7 40.1 52.9 57.9 49.8 35.7 22.9 40.7 54.2 60.0 52.4 38.3 23.7 PANTRY 39.0 52.8 209 60.3 54.7 41.7 19.4 29.0 34.7 36.4 36.4 34.3 28.3 39.6 47.3 49.2 49.1 46.8 38.5 46.3 55.6 57.4 57.5 55.1 45.0 41.9 50.3 52.4 52.6 50.3 41.2 31.4 37.8 39.5 39.4 37.3 30.7 Light Fixture Schedule Symbol Qty Label Description Fixture Watts Total Watts 2 $LV1 DL134003 / LOW VOLTAGE SWITCH / 0-10V DIMMER / FOR CEILING SENSORS 0.1 0.2 2 $OSD DL119959 / DUAL TECH OCCUPANCY SENSOR / 0-10V DIMMING WALL SWITCH 2 4 5 EM DL146027 / DUAL 330 LUMEN LED LAMP EMERGENCY UNIT 3.37 16.85 2 EXC DL52241/ REMOTE CAPABLE COMBO UNIT/ RED LETTER / LED N.A. 14 30 L1 OPT24-LED-48-W-40/ 2X4 CENTER BAFFLE TROFFER 38.8 1164 9 L2 OPT22-LED-45L-W-40 / 2X2 CENTER BAFFLE TROFFER 36 324 6 OS DL41002 / DUAL TECH CEILING OCCUPANCY SENSOR 0.1 0.6 2 PP DL41003 / POWER PACK 20A / 120-277V 0.1 0.2 Footcandle Summary Label Units Avg GENERAL OFFICE 206_Workplane Fc 49.35 OFFICE ADDITION 205 Fc 54.61 OFFICE MANAGER_Workplane Fc 60.27 PANTRY 209 Fc 39.91 PAYROLL OFFICE 208_Workplane Fc 43.04 FOR COMBINATION SENOR/DIMMER $OSD1 DIMMING CABLE ADDED All electrical work shall comply with National, State, and Local codes including and not limited to the National Electric Code, NFPA 101 Life Safety Code, ASHREA and /or IECC Energy Codes. The information contained in this document is proprietary to CBMC Lighting Solutions. This document is prepared for a specific site and incorporates calculations based on data available from the client at this time. By accepting and using this document, the recipient agrees to protect its contents from further dissemination, (other than that within the organization necessary to evaluate such specification) without the written permission of CBMC Lighting Solutions. the contents of this document are not to be reproduced or copied in whole or in part without the written permission of CBMC Lighting Solutions. copyright © 2020 CBMC Lighting Solutions all rights reserved. CB18831 5855 KOPETSKY DR. SUITE G. | INDIANAPOLIS, IN 46217 317-780-8350| WWW.CBMCINC.COM HYUNDAI OF CARMEL RENOVATION Lighting Plan Calculations Revision 6/17/21 This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with IESNA approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps and LED lumen package, location adjustments, and other variable field conditions. Contractor to check and verify all dimensions on site before commencing any work shown. Scale: Project No: Date: E01 Drawing No: 1 4" = 1' WP Drawn By: RT - Checked By: LIGHTING NOTES: 1. See reflected ceiling plan for mounting heights of recessed and lay-in fixtures. 2. Footcandle values are calculated 3' A.F.F. 3. Footcandle values are maintained with a .90 lumen loss factor. 5. Reflectance values for office spaces are 80/50/20 1 LIGHTING PLAN SCALE: 1/4" = 1' (24x36) 1/8" = 1'-0" (11x17) National Lighting Vendor: For pricing and technical assistance contact: Rob Thomson of CBMC INC, tel# 317-828-4119 / rthomson@cbmcinc.com William Proctor - Lighting Consultant - wproctor@cbmcinc.com 3 WALL SENSOR WIRING / COMBO WALL SENSOR DIMMER WIRING SCALE: NTS 2 0-10V DIMMER WIRING SCALE: NTS L2 EXC 3 SCALE: 1/8" = 1'-0" ELECTRICAL POWER AND SYSTEMS PLAN E100 ELECTRICAL PLANS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 210519 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p MEP Consulting Engineers 262 Tradewinds Drive Santa Rosa Beach Florida 32459 317.506.8151 dave@gnaengineering.com GOODERUM & ASSOCIATES ENGINEERING P: E: 874 Cheltenham Drive Avon IN, 46123 South Office North Office 07-09-2021 J E F F R E Y M . P E R K E Y 07-09-2021 07-09-2021 1. REMOVE FIXTURE AND REUSE BRANCH CIRCUIT FOR FUTURE FIXTURE. 2. EXISTING FIXTURE TO REMAIN AND BE REUSED. 3. REMOVE FIXTURE AND REUSE BRANCH CIRCUIT FOR FUTURE LIGHT. TYPICAL. 4. CONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING BRANCH CIRCUIT. RECONFIGURE EXISTING BRANCH CIRCUITRY AS REQUIRED TO ACCOMMODATE NEW LIGHT FIXTURES AND CONTROL. 5. PROVIDE POKE THRU TWO-COMPARTMENT FLOOR BOX SIMILAR TO "HUBBELL SYSTEM ONE." FIELD COORDINATE EXACT LOCATION OF FLOOR BOX ROUGH-IN WITH LOCATION OF SYSTEM FURNITURE. KEY NOTES: 1. REFERENCE SHEET E001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. DEMOLITION PLANS ARE DIAGRAMMATIC AND BASED ON LIMITED SURVEY DATA. ELECTRICAL CONTRACTOR SHALL VISIT SITE, EXAMINE ALL PLANS AND DETERMINE EXISTING ELECTRICAL ELEMENTS TO REMAIN AND EXISTING TO BE REMOVED AS NEEDED TO MEET DESIGN INTENT. ELECTRICAL CONTRACTOR SHALL THEN WRING OUT CONDUCTORS AND REMOVE ITEMS MAINTAINING CONTINUITY ON CONDUCTORS TO REMAIN. E.C. SHALL DE-TERMINATE AND REMOVE OR CAP AND TAG ALL CONDUCTORS AND ASSOCIATED RACEWAYS TO BE ABANDON. PRIOR TO ANY DEMOLITION, E.C. SHALL MAKE SAFE ALL ENERGIZED ITEMS TO BE REMOVED. 3. BRANCH CIRCUIT NUMBERS SHOWN ARE FOR GROUPING PURPOSES ONLY. FIELD VERIFY ACTUAL CIRCUIT NUMBERS AND UPDATE AS-BUILTS ACCORDINGLY. 4. PROVIDE BRANCH CIRCUITRY FROM NEAREST 208Y/120V BRANCH CIRCUIT BREAKER PANEL IN AVAILABLE SPACE. INSTALL NEW 20/1P CIRCUIT BREAKERS AS REQUIRED TO ACCOMMODATE NEW CIRCUITRY. DO NOT EXCEED NEC ALLOWANCES FOR LOADING OF BRANCH CIRCUITS. 5. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND NIGHT LIGHTS SHALL HAVE UNSWITCHED BRANCH CIRCUIT. CONNECT THE NEW LIGHT FIXTURES TO NEAREST AVAILABLE UNSWITCHED LIGHTING BRANCH CIRCUIT. 6. REFERENCE CBMC LIGHTING PLAN FOR EXACT FIXTURE LOCATIONS, SPECIFICATIONS, AND MORE INFORMATION. # GENERAL NOTES: 1 SCALE: 1/8" = 1'-0" ELECTRICAL DEMOLITION PLAN 2 SCALE: 1/8" = 1'-0" ELECTRICAL LIGHTING PLAN KEY PLAN SCALE: NONE 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 4 4 5 CONTRACTOR'S SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. ALL WORK SHALL IN BE IN FULL ACCORDANCE WITH 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70), 2010 INDIANA ENERGY CODE (ASHRAE 90.1-2007), PERTINENT STATE, COUNTY, CODES AND ORDINANCE AND INDIANA AMENDMENTS. COORDINATE WORK WITH OTHER TRADES. ELECTRICAL CONTRACTOR SHALL BEAR ALL COSTS RESULTING FROM ANY NON COMPLIANCE WITH CODE REQUIREMENTS 7. MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS INDICATED OTHERWISE. MATERIAL SHALL BEAR U.L. LABEL WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED AND LISTED BY U.L. MATERIALS AND EQUIPMENT SHALL CONFORM WITH THE LATEST ISSUES OF APPLICABLE TECHNICAL STANDARDS. 8. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE SYSTEM OF LIGHTING, RECEPTACLES, AND POWER AS REQUIRED. VERIFY ALL VOLTAGES AND PHASE REQUIREMENTS WITH MECHANICAL CONTRACTOR'S EQUIPMENT PRIOR TO PERFORMING ANY WORK. 9. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO EXTRAS WILL BE ENTERTAINED FOR CONTRACTORS FAILURE TO IDENTIFY EXISTING CONDITIONS AND ADJUST AS REQUIRED TO MEET DESIGN INTENT. 10. ALL CONDUIT COUPLINGS AND CONNECTIONS SHALL BE COMPRESSION TYPE AND MADE TO ENSURE POSITIVE GROUNDING CONTINUITY. MAKE CONNECTIONS TO EQUIPMENT SUBJECT TO VIBRATION WITH 18 INCHES OF FLEXIBLE WATERTIGHT CONDUIT WITH WATERTIGHT FITTINGS. PROVIDE FOR SUPPORT AND SECURING OF ALL CONDUIT AND EQUIPMENT. CONNECTIONS TO LIGHTING FIXTURES SHALL BE MADE WITH SIX (6) FEET OF FLEXIBLE CONDUIT FROM A BOX WITHIN TWO (2) FEET OF THE FIXTURE. SPLICE ALL WIRES ONLY IN ACCESSIBLE BOXES. ALL FIXTURE WHIPS TO BE FLEXIBLE METAL CONDUIT 1/2" MINIMUM SIZE WITH COMPRESSION CONNECTORS WITH INSULATED THROATS. WHIPS SHALL NOT EXCEED 6'. FIXTURE WHIPS TO BE SUPPORTED FROM BUILDING STRUCTURE. WIRING AND RACEWAYS 1. ALL LIGHTING AND BRANCH CIRCUIT WIRING SHALL BE SOLID COPPER MINIMUM SIZE #12 AWG. 600V INSULATION, 75 DEG. C., TYPE THW OR THWN, NOT LESS THAN #12 AWG. ALL WIRE SERVING AS FEEDS TO DISTRIBUTION PANEL BOARDS OR INTEGRAL HORSEPOWER MOTORS SHALL BE EITHER STRANDED COPPER CONDUCTOR OR ASTM B800 ALUMINUM AA-8000 SERIES. THESE SHALL BE SIZED NOT LESS THAN #10 AWG FOR COPPER AND NOT LESS THAN #8 AWG FOR ALUMINUM. EACH WITH MINIMUM 600V THW OR THWN INSULATION, 75 DEG. C. ALL FEEDER SHALL BE SIZED IN ACCORDANCE WITH NEC 310.15. 2. ELEVATOR POWER: A THREE (3) PHASE, ELECTRICAL FEEDER SYSTEM MUST BE PROVIDED THAT IS ENCLOSED IN EMT WITH A SEPARATE EQUIPMENT GROUNDING CONDUCTOR TERMINATING IN THE MACHINE ROOM / SPACE. FEEDER CONDUCTORS AND GROUNDING CONDUCTOR MUST BE COPPER. SIZE OF THE FEEDERS AND GROUNDING CONDUCTOR TO SUIT ELEVATOR POWER CHARACTERISTICS. A FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER IF ALLOWED BY AHJ, CAPABLE OF BEING LOCKED IN THE 'OFF' POSITION, FOR EACH ELEVATOR PER THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) WITH FEEDER OR BRANCH WIRING TO CONTROLLER [620-51] AND [620-61(D)]. FUSES ARE TO BE CURRENT LIMITING CLASS RK1 OR EQUIVALENT SIZED PER ELEVATOR SCCR. CIRCUIT BREAKERS ARE TO HAVE CURRENT LIMITING CHARACTERISTICS EQUIVALENT TO CLASS RK1 FUSES, FUSES OR CIRCUIT BREAKERS ARE TO BE TIME DELAY TO COVER THE FULL LOAD UP ACCELERATING CURRENT AS LISTED IN ELEVATOR SHOP DRAWINGS. PROVIDE A SEPARATE 125 VOLT AC, 15 AMPERE SINGLE PHASE BRANCH CIRCUIT AND SPST FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER, CAPABLE OF BEING LOCKED IN THE 'OFF' POSITION, TO SUPPLY THE CAR LIGHTS, RECEPTACLES, AUXILIARY LIGHTING POWER SOURCE AND VENTILATION ON EACH CAR IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE [NEC620-53]. 3. ALL EXPOSED WIRING SHALL BE IN EMT RACEWAY. EXTERIOR WIRING SHALL BE IN CONDUIT. CONCEALED WIRING SHALL BE IN EMT OR METAL CLAD CABLE WHERE ALLOWED BY CODE. 4. ALL LOW VOLTAGE WIRING IN PLENUM RATED CEILINGS OR EXPOSED IN ROOMS SHALL BE PLENUM RATED CABLE. 5. ALL CABLE SHALL BE NEW WIRE OF RECENT MANUFACTURE AND IN ACCORDANCE WITH THE LATEST STANDARDS OF IPCEA AND NEMA AS A MINIMUM. 6. ALL DEVICES AND EQUIPMENT SHALL BE SOLIDLY GROUNDED IN ACCORDANCE WITH NEC REQUIREMENTS. 7. ALL SOLID CONDUCTOR WIRES MAY BE TERMINATED UNDER SCREW HEADS. STRANDED WIRES MAY BE TERMINATED BY USING PUSH-IN CLAMP TYPE CONNECTORS FURNISHED WITH DEVICES OR TERMINATED WITH COMPRESSION TYPE TERMINAL LUGS. SET SCREW TYPE TERMINATIONS ARE NOT PERMITTED. 8. NO MOTORS ARE TO BE SUPPLIED UNDER THIS CONTRACT UNLESS ITEMS REQUIRING A MOTOR ARE FURNISHED BY THIS CONTRACTOR. THE CONTRACTOR SHALL FURNISH ALL STARTERS FOR ALL MOTORS REQUIRING A STARTER. THE CONTRACTOR SHALL CONNECT ALL POWER EQUIPMENT IF & WHERE SHOWN ON PLANS UNLESS OTHER-WISE SPECIFIED & ASSURE OWNER THE MOTORS ARE IN GOOD RUNNING ORDER. 9. E.C. SHALL PROVIDE ALL COMPONENTS NEEDED TO MEET MEANS OF DISCONNECT PER N.E.C. FOR ALL HARD WIRED EQUIPMENT. 10. E.C. SHALL PROVIDE MEDICAL-GRADE RACEWAYS IN ALL MEDICAL FACILITIES PER THE NEC. PANELS AND DISCONNECTS 1. PANELBOARDS SHALL BE A DEAD-LOCK SAFETY TYPE, SURFACE OR RECESSED MOUNTED AS SHOWN, EQUIPPED WITH THERMAL-MAGNETIC MOLDED CASE CIRCUIT BREAKERS WITH FRAME AND TRIP RATINGS AS REQUIRED. TERMINALS FOR FEEDER CONDUCTORS TO THE PANELBOARD MAINS AND NEUTRAL SHALL BE U.L. LISTED AS SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED. TERMINALS FOR BRANCH CIRCUIT WIRING, BOTH BREAKER AND NEUTRAL, SHALL BE U.L. LISTED AND CONNECTORS SHALL BE OF THE FULL COMPRESSION TYPE.THE PANELBOARD BUS ASSEMBLY SHALL BE ENCLOSED IN A STEEL CABINET. THE SIZE OF THE WIRING GUTTERS AND GAUGE OF STEEL SHALL BE IN ACCORDANCE WITH NEMA STANDARD PUBLICATION NO. PB-1971 AND U.L. STANDARDS NO. 67 FOR PANELBOARDS. CABINET SHALL BE FABRICATED FROM GALVANIZED STEEL OR EQUIVALENT RUST-RESISTANT STEEL. FRONTS SHALL INCLUDE DOORS AND HAVE FLUSH, BRUSHED STAINLESS STEEL, CYLINDER TUMBLER-TYPE LOCKS WITH CATCHES AND SPRING LOADED DOOR PULLS. THE FLUSH LOCK SHALL NOT PROTRUDE BEYOND THE FRONT DOOR. ALL PANELBOARD LOCKS SHALL BE KEYED ALIKE. FRONTS SHALL HAVE ADJUSTABLE INDICATING TRIP CLAMPS WHICH SHALL BE CONCEALED WHEN THE DOORS ARE CLOSED. DOORS SHALL BE MOUNTED BY COMPLETELY CONCEALED STEEL HINGES. FRONTS SHALL NOT BE REMOVABLE WITH DOOR IN THE LOCATED POSITION. A CIRCUIT DIRECTORY FRAME AND TYPE WRITTEN CARD WITH A CLEAR PLASTIC COVERING SHALL BE PROVIDED ON THE INSIDE OF THE DOOR. THE DIRECTORY CARD SHALL PROVIDE A SPACE AT LEAST 1/4" HIGH X 3" LONG OR EQUIVALENT FOR EACH CIRCUIT. FRONTS SHALL BE OF CODE GAUGE, FULL FINISHED STEEL WITH RUST-INHIBITING PRIMER FACTORY FINISHED ENAMEL PAINT. 2. LOAD CENTERS SHALL BE UL LISTED AND MANUFACTURED IN ACCORDANCE WITH THE LATEST NEMA STANDARDS. CABINETS SHALL USE HINGED STYLE DOORS. MOUNT AT 6'-6" TO TOP OF CABINET. 3. CIRCUIT BREAKERS SHALL BE QUICK-MAKE, QUICK-BREAK, THERMAL-MAGNETIC, TRIP INDICATING AND HAVE COMMON TRIP ON ALL MULTI-POLE BREAKERS. BRANCH CIRCUIT BREAKERS FEEDING CONVENIENCE OUTLETS SHALL HAVE SENSITIVE INSTANTANEOUS TRIP SETTINGS OF NOT MORE THAN 10 TIMES THE TRIP RATING OF BREAKER TO PREVENT REPEATED ARCING SHORTS RESULTING FROM FRAYED APPLIANCE CORDS. CONNECTION TO BUS SHALL BE BOLT ON. 4. CONTRACTOR TO OBTAIN MAXIMUM FAULT CURRENT AVAILABLE FROM THE UTILITY. CALCULATE THE FAULT CURRENT AVAILABLE AT THE PANELS. ALL PANELS/BREAKERS/SWITCHES ARE TO BE BRACED TO EXCEED MAXIMUM AVAILABLE FAULT CURRENT AND CIRCUIT BREAKERS ARE TO BE CAPABLE OF INTERRUPTING FAULT CURRENT. MANUFACTURER SHALL PROVIDE ALL REQUIRED FAULT CURRENT AND ARC-FLASH LABELING PER 110.16 AND 110.24. 5. MAXIMUM LOADING OF 20 AMP CIRCUITS SHALL NOT EXCEED 1750 WATTS. VOLTAGE DROP OF BRANCH CIRCUITS SHALL NOT EXCEED 3% AND FEEDER CIRCUITS SHALL NOT EXCEED 2%. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS AIR AND WATER TIGHT. FIRE STOP WHERE REQUIRED. 6. CONTRACTOR SHALL PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL PANELS AS REQUIRED BY NEC 408.4(B) AND SHALL LABEL ALL DISCONNECTS, TRANSFORMERS AND MOTORS OVER 1 HP. FURNISH TYPEWRITTEN PANEL DIRECTORIES TO IDENTIFY ALL ELECTRICAL CIRCUITS BOTH NEW AND EXISTING. 7. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, NEMA TYPE 1 FOR INDOOR SERVICE AND NEMA TYPE 3R FOR OUTDOOR SERVICE, SUITABLE FOR PADLOCKING, NUMBER OF POLES, RATINGS, FUSES (IF REQUIRED) SHALL BE AS INDICATED ON THE DRAWINGS. DEVICES 1. VERIFY EXACT LOCATION, COLOR AND HEIGHTS OF ALL OUTLETS, RECEPTACLES, LIGHT FIXTURES AND EQUIPMENT WITH OWNER'S REPRESENTATIVE PRIOR TO START OF WORK. FURNISH GENERAL SERVICE DUPLEX'S, 15 AMP SWITCHES, 15/20 AMP GFICS, HEAVY DUTY DISCONNECTS, HVAC SSU SWITCHES, PANEL BOARDS, LOAD CENTERS, DISTRIBUTION PANELS ETC. AS REQUIRED. 2. CONVENIENCE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR (A.F.F.) TO BOTTOM UNLESS NOTED OTHERWISE, SWITCHES AND PUSHBUTTONS SHALL BE 42" A.F.F. TO BOTTOM UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS. 3. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FINAL LOCATIONS AND COLORS OF ALL DEVICES WITH OWNER. 4. INSTALL ALL DEVICES PARALLEL AND PERPENDICULAR TO ADJACENT WALL AND CEILING, FLUSH WITH SURROUNDING SURFACES AND FREE FROM ALL OBSTRUCTIONS. REWORKING OF EQUIPMENT INSTALLED IMPROPERLY SHALL BE AT THE CONTRACTOR'S EXPENSE. 5. SWITCHES, BOXES, ETC., SHALL BE NEMA TYPE 1 CONSTRUCTION FOR INDOOR APPLICATIONS AND NEMA TYPE 3R CONSTRUCTION FOR OUTDOOR APPLICATIONS. 6. SWITCHES SHALL MEET NEMA STANDARDS, COLOR SHALL BE BY ARCHITECT. SWITCHES SHALL BE EQUAL TO HUBBELL COMMERCIAL SPECIFICATION GRADE 20/15 AMPERES, SINGLE POLE, 125/277V. MULTI-POLE OR SPECIAL SWITCHING SHALL BE AS NOTED ON THE DRAWINGS. 7. RECEPTACLES SHALL BE 125 VOLT, 15/20 AMPERES, DUPLEX, GROUNDED HUBBELL COMMERCIAL SPECIFICATION GRADE. SPECIAL RECEPTACLES SHALL BE AS NOTED ON THE DRAWINGS. 8. MATCHING COVER PLATES SHALL BE PROVIDED FOR ALL RECEPTACLES AND SWITCHES. LIGHTING FIXTURES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIXTURES- MODEL NUMBERS, QUANTITY AND DISTANCE BETWEEN LIGHTING FIXTURE PER FLOOR PLANS. 2. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FIXTURE QUANTITY, MODELS, STYLE, TRIM, LENS, ETC. WITH OWNER FOR ALL FIXTURES. 3. PROVIDE LIGHTING FIXTURES COMPLETE WITH, BUT NOT NECESSARILY LIMITED TO, HOUSINGS, LAMPS, LAMP HOLDERS, REFLECTORS, BALLASTS, STARTERS AND WIRING. 4. INSTALL LIGHTING FIXTURES AT LOCATIONS AND HEIGHTS AS INDICATED, IN ACCORDANCE WITH FIXTURE MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC, NECA'S "STANDARD OF INSTALLATION", NEMA STANDARDS, AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT LIGHTING FIXTURES FULFILL REQUIREMENTS. 5. COORDINATE WITH OTHER ELECTRICAL WORK AS APPROPRIATE TO PROPERLY INTERFACE INSTALLATION OF INTERIOR LIGHTING FIXTURES WITH OTHER WORK. 6. E.C. TO FASTEN FIXTURES SECURELY DIRECTLY TO BUILDING STRUCTURAL SYSTEM. LIGHT TROFFERS SHALL BE SUPPORTED AT EACH CORNER OF FIXTURE BY WIRES OF SAME GAUGE AS HANGER WIRE FOR CEILING GRID. ATTACH EARTHQUAKE CLIPS TO GRID AS RECOMMENDED BY LIGHT MANUFACTURER. USE SCREWS IF REQUIRED BY MANUFACTURER. ATTACH THE WIRE TO THE STRUCTURE ABOVE. LIGHTS SHALL NOT BE SUPPORTED IN ANYWAY BY LAY-IN CEILING. 7. FIXTURE LOCATIONS SHALL BE AT APPROXIMATE LOCATIONS AS SHOWN ON THE DRAWINGS FREE FROM ALL OBSTRUCTIONS. CLEAN ALL LIGHTING EQUIPMENT AFTER LIGHTING INSTALLATION AND GENERAL CONSTRUCTION IS COMPLETE. REPAIR ANY FIXTURES DAMAGED DURING CONSTRUCTIONS. 8. PROVIDE NECESSARY MOUNTING FRAMES, SUPPORTS AND RELATED ITEMS REQUIRED TO PROPERLY INSTALL FIXTURES. SUPPORT FIXTURES INDEPENDENTLY OF PIPING AND DUCTWORK. MAKE MODIFICATIONS TO THE STRUCTURE AS REQUIRED TO INSTALL FIXTURES. ANY MODIFICATIONS TO THE STRUCTURE SHALL NOT IMPAIR THE STRUCTURAL INTEGRITY OF THE BUILDING. LOW VOLTAGE 1. ALL LOW VOLTAGE CABLE WHERE CONCEALED IN CONSTRUCTION OR IN EXPOSED OPEN AREAS SHALL BE RUN IN MINIMUM 3/4" EMT CONDUIT. CONTRACTOR SHALL INSTALL 3/4" CONDUIT (MINIMUM) FROM EACH LOW VOLTAGE ROUGH-IN LOCATION TO ACCESSIBLE CEILING SPACE, LOW VOLTAGE WIRE TRAY OR HANGERS AND THEN TO MDF, HEAD-IN, PBX PUNCH DOWN, CONTROLLER ETC. 2. E.C. SHALL COORDINATE WITH LOCAL PHONE AND CABLE PROVIDER AS CHOSEN BY OWNER AND PROVIDE RACEWAYS FOR BRINGING IN SERVICES AS REQUIRED. 3. ALL LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN PLENUMS. 4. ALL DATA CABLE SHALL BE CAT 6 UNLESS OTHER WISE NOTED. TERMINATE, LABEL AND TEST ALL WIRING. 5. ALL TV CABLE SHALL BE HIGH DEFINITION COAX RG6 OR AS REQUIRED BY PROVIDER, VERIFY PRIOR TO ROUGH IN. FIRE STOPPING. 1. FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE WITH SECTIONS 714 OF THE IBC AND NFPA 221. 2. CONTRACTOR SHALL MAKE REFERENCE TO ARCHITECTURAL PLANS AND PROVIDE ALL REQUIRED FIRE STOPPING. 3. CONTRACTOR SHALL PROVIDE AHJ WITH FULL SUBMITTAL INDICATING METHODS OF CONSTRUCTION AND UL LISTINGS FOR EACH PENETRATION SYSTEM USED. 4. PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS OR FLOOR CEILING ASSEMBLIES BY ELECTRICAL DEVICES, RACEWAYS OR PANELS, ETC. SHALL COMPLY WITH SECTIONS 713.2 THROUGH 713.3.3 OF THE IBC. 5. ACCESS DOORS REQUIRED IN CEILINGS OF FIRE-RESISTANCE-RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND LABELED BY AN APPROVED AGENCY FOR SUCH PURPOSE. CLOSE OUT 1. PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS AND PROVIDE AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL MANUFACTURERS WARRANTED EQUIPMENT AMPS MECHANICAL CONTRACTOR ELECTRICAL ABBREVIATIONS MANUFACTURER MOUNTING HEIGHT MFR MH MINIMUM MOTOR OPERATED DAMPER MLO MIN MOD MOCP MOUNTED NOT IN CONTRACT PLUMBING CONTRACTOR ON CENTER NOT TO SCALE MTD NIC PC NTS OC CO COMPANY RLA RUNNING LOAD AMPS ELECTRIC CONTRACTOR DOWN DRAWING(S) ELECTRICAL DISTRIBUTION CENTER EQUIPMENT EC DN DWG(S) EQUIP EDC EWC ETR FULL LOAD AMPS MAXIMUM FLA MAX MB MAIN BREAKER MC CONTR CONTRACTOR EXISTING TO REMAIN ELECTRIC WATER COOLER MCA MIMIMUM CIRCUIT AMPS MAXIMUM OVER CURRENT PROTECTION MAIN LUG ONLY EM EMERGENCY PSI POUNDS PER SQUARE INCH RPM REVOLUTIONS PER MINUTE HP HORSE POWER GC GENERAL CONTRACTOR AFF ABOVE FINISHED FLOOR EX EXISTING FS FLOW SWITCH A V VOLTS UON UNLESS OTHERWISE NOTED LIGHTING PANELBOARD SCHEDULE ABBREVIATIONS PN POWER NON-SEASONAL MOTOR SUMMER MOTOR NON-SEASONAL MOTOR NON-SEASONAL INTERMITTENT MOTOR WINTER MS MN MNI MW PW POWER WINTER KT KITCHEN R RECEPTACLE L ELECTRICAL SYMBOLS SPECIAL EQUIPMENT COORDINATE W/SUPPLIER JUNCTION BOX DISCONNECT OUTLET - 4 WAY MOTOR OUTLET - GROUND FAULT INTERRUPT OUTLET - DUPLEX RECESSED DOWN LIGHT LIGHT FIXTURE - ON NIGHT LIGHT CIRCUIT LAYIN TROFFER FIXTURE SUSPENDED LAYIN EXIT SIGNAGE SURFACE MOUNTED STRIP LIGHT SUSPENDED STRIP LIGHT LOW VOLTAGE TWO LINE LOW VOLTAGE ONE LINE ANALOG PHONE LINE WIRELESS ACCESS POINT OUTLET - 220V EXIT SIGNAGE WITH EMERGENCY HEADS LIGHT FIXTURE - WALL SCONCE LIGHT FIXTURE - PENDANT SURFACE MOUNTED LAYIN J FLOOR OUTLET WITH POWER, DATA AND PHONE FLR D 3 SWITCH SWITCH WITH DIMMER SWITCH - 3 WAY SWITCH WITH OCCUPANCY SENSOR OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH - 4 WAY 4 OUTLET - GROUND FAULT INTERRUPT WEATHERPROOF WP LOW VOLTAGE # LINES # PUSH BUTTON BUZZER B TIME CLOCK TC PHOTO CELL P POWER POLE PANEL DESIGATION X: XX,XX,XX CIRCUIT BREAKER NUMBERS WAP EMERGENCY LIGHTING UNIT EMERGENCY EXIT EGRESS LIGHT LIGHT FIXTURE - TRACK LIGHT FIXTURE - UNDER COUNTER LIGHT FIXTURE - RECESSED DOWN LIGHT LIGHT FIXTURE - VANITY LIGHT OUTLET - DUPLEX WITH USB J PP OS HS WP ELECTRICAL ABBREVIATIONS, SYMBOLS, & SPECIFICATIONS 220 LV LOW VOLTAGE DIMMING SYSTEM DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 210519 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p MEP Consulting Engineers 262 Tradewinds Drive Santa Rosa Beach Florida 32459 317.506.8151 dave@gnaengineering.com GOODERUM & ASSOCIATES ENGINEERING P: E: 874 Cheltenham Drive Avon IN, 46123 South Office North Office 07-09-2021 J E F F R E Y M . P E R K E Y 07-09-2021 07-09-2021 DETAILS NOTE: CONTRACTOR TO CONFIRM HEIGHT LIMITS AND METAL STUD SIZES PRIOR TO ORDERING MATERIALS FOR NEW PARTITIONS 05-10-21 NOTE: CONTRACTOR TO VERIFY REQUIRED PARTITION STUD DEPTH WHERE MATCHING EXISTING PARTITION CONSTRUCTION. 07-09-21 WD PT-3 PT-3 PT-3 EX - - EX STN-1 STN-1 EX REPLACE HARDWARE FOR NEW SWING AND HANDING; SAND AND RELOCATE EXISTING DOOR #206K, 3'-0" X 7'-0" (VIF) REFINISH AS NEEDED WD HM HM HM HM EX INTERIOR - REMAINS, VERIFY OPERATION & CODE COMPLIANCE* 4" 2" 4" H1 OFFICE LOCKSET: HINGES: CLOSER: ACCESSORY: H2 LOCKSET: HINGES: CLOSER: ACCESSORY: DOOR HARDWARE TYPES SCHLAGE AL-SERIES AL53PD CYLINDER LOCK W/ ADA LEVER STYLE OPERATOR NONE FIN: 626 FIN: US26D FIN: N/A FIN: 626 BB1279 4-1/2 X 4-1/2 (MATCH EXISTING) BREAKROOM BB1279 4-1/2 X 4-1/2 LCN 1461 REG/PA SCHLAGE AL-SERIES AL103 JUPITER (PASSAGE FUNCTION) H10 CABINET HARDWARE PULL: DP128 SERIES - 6-11/16" ROUND TOP DRAWER PULL HINGE: A7.0 DOOR SCHEDULE AND DETAILS DRAWING ISSUE HISTORY BID / PERMIT ISSUE: CONSTRUCTION SET: COPYRIGHT 2021 09-009-91 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: HYUNDAI OF CARMEL OFFICE REMODEL 4200 E 96th STREET CARMEL, INDIANA N A u t o m o t i v e G r o u p ADDRESS: 1414 N DEARBORN PKWY CHICAGO, ILLINOIS 60610 FRED@NAPLETON.COM | 630.455.2910 06-21-21 07-09-21 NAPLETON'S HYUNDAI OF CARMEL 4200 E 96th STREET INDIANAPOLIS, IN 46240 GENERAL CONTRACTOR COVER SHEET ARCHITECT MEP ENGINEER LOCATION 06-16-21 INDEX OF DRAWINGS PROJECT DATA SHEET DRAWING NAME DATE OCCUPANT LOAD CALCULATIONS 07-09-21