Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0 - TRUSS SEALS
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. March 18,2022 Johnson, Andrew Pages or sheets covered by this seal: I50839981 thru I50840000 My license renewal date for the state of Indiana is July 31, 2022. 2200487-2200487A TG105 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss A02 Truss Type Common Qty 17 Ply 1 TG105 Job Reference (optional) I50839981 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:30 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-ZckBD_xgVU?DGD?3RGMUBM9ItNmMjNt2Pk3NG1za2pZ Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 14 13 1223242526 27 28 3x6 4x6 3x6 4x8 4x4 3x6 4x4 1.5x4 4x4 1.5x4 4x8 4x4 10-7-1110-7-11 17-2-66-6-11 27-10-010-7-11 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-8-1110-0-00-8-118.00 12 Plate Offsets (X,Y)-- [2:0-4-8,Edge], [10:0-4-8,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.38 0.60 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.23 -0.59 0.04 0.05 (loc) 12-21 12-21 10 14-17 l/defl >999 >566 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 113 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-192(LC 8) Max Uplift 2=-87(LC 10), 10=-87(LC 11) Max Grav 2=1208(LC 18), 10=1208(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1531/209, 4-6=-1352/235, 6-8=-1352/235, 8-10=-1531/209 BOT CHORD 2-14=-137/1342, 12-14=0/918, 10-12=-61/1215 WEBS 6-12=-86/623, 8-12=-385/215, 6-14=-86/623, 4-14=-385/215 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss A03 Truss Type Roof Special Qty 3 Ply 1 TG105 Job Reference (optional) I50839982 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:31 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-1oIZQKxIGo74uNaG?_tjkZiSLm6lSqIBeOowoTza2pY Scale = 1:64.8 1 2 3 45 6 7 8 9 10 11 12 20 19 18 1716 15 14 132930 5x9 6x10 3x6 4x8 4x4 1.5x4 1.5x4 1.5x4 2x4 5x6 4x4 4x8 4x4 5x9 4x6 1.5x4 4x8 7-1-47-1-4 10-7-113-6-7 14-7-83-11-14 17-7-83-0-0 22-7-04-11-8 27-10-05-3-0 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 14-7-8 0-8-8 17-7-8 3-0-0 22-7-0 4-11-8 27-10-0 5-3-0 28-10-0 1-0-0 0-8-1110-0-00-8-112-0-08.00 12 Plate Offsets (X,Y)-- [2:0-4-8,Edge], [5:0-4-8,0-3-4], [6:0-7-7,0-3-0], [15:0-2-4,0-2-8], [17:0-2-8,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.40 0.59 0.32 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.22 -0.57 0.11 0.05 (loc) 20-23 20-23 11 20-23 l/defl >999 >583 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 144 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 16-18,7-14: 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 19-20,18-19. WEBS 1 Row at midpt 6-19, 6-20 REACTIONS. (size)2=0-3-8, 11=0-3-8 Max Horz 2=192(LC 9) Max Uplift 2=-87(LC 10), 11=-87(LC 11) Max Grav 2=1173(LC 1), 11=1173(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1499/208, 4-6=-1283/232, 6-7=-1751/290, 7-9=-1772/201, 9-11=-1555/178 BOT CHORD 2-20=-136/1239, 16-17=0/1041, 15-16=0/1026, 7-15=-281/153, 11-13=-58/1227 WEBS 4-20=-394/217, 13-15=-64/1289, 6-17=0/608, 17-20=0/1183, 6-15=-163/859, 9-13=-428/86 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss A04 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839983 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:34 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-RNzi2M_AZjVflqJrg6QQMCK_U_D7fAqdKM1bPoza2pV Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 37 35 34 33 32 31 30 29 28 27 26 25 42 41 40 39 38 36 4x6 4x6 4x6 3x6 4x4 3x6 4x4 4x4 5x6 9-4-89-4-8 12-4-83-0-0 18-5-86-1-0 27-10-09-4-8 -1-0-0 1-0-0 6-4-0 6-4-0 7-1-4 0-9-4 13-11-0 6-9-12 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-8-1110-0-00-8-118.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-0-3], [6:0-2-4,0-2-4], [16:0-2-4,0-2-4], [23:0-3-4,0-0-3], [34:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.34 0.23 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.07 0.01 0.03 (loc) 37-45 37-45 2 37-45 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 179 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 2-37,36-37,35-36. WEBS 1 Row at midpt 11-34, 10-38, 12-33 JOINTS 1 Brace at Jt(s): 39, 41 REACTIONS.All bearings 15-5-8 except (jt=length) 2=0-3-8, 36=0-3-8. (lb) - Max Horz 2=192(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 2, 23, 33, 32, 31, 30, 29, 28, 27, 26, 25 except 35=-260(LC 10) Max Grav All reactions 250 lb or less at joint(s) 23, 33, 32, 31, 30, 29, 28, 27, 26, 25, 23 except 2=569(LC 1), 35=352(LC 18), 34=263(LC 21), 36=326(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-405/122 BOT CHORD 2-37=-105/487, 36-37=-105/487, 35-36=-105/487 WEBS 4-37=0/260, 4-42=-568/195, 41-42=-486/148, 40-41=-522/169, 39-40=-549/183, 38-39=-526/175, 35-38=-626/221 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 23, 33, 32, 31, 30, 29, 28, 27, 26, 25, 23 except (jt=lb) 35=260. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss B01 Truss Type Common Supported Gable Qty 1 Ply 1 TG105 Job Reference (optional) I50839984 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:35 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-vZX4Gi?pK0dWN_u1EqyfuPtCQOcIOhUnY0m8xEza2pU Scale = 1:38.0 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 4x4 3x4 5x6 3x4 21-8-021-8-0 -1-0-0 1-0-0 10-10-0 10-10-0 21-8-0 10-10-0 22-8-0 1-0-0 0-5-74-11-100-5-75.00 12 Plate Offsets (X,Y)-- [18:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.07 0.04 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 12 13 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 21-8-0. (lb) - Max Horz 2=-64(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 19, 20, 21, 22, 17, 16, 15, 14, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 18, 19, 20, 21, 22, 17, 16, 15, 14, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 19, 20, 21, 22, 17, 16, 15, 14, 12. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss B02 Truss Type Common Qty 3 Ply 1 TG105 Job Reference (optional) I50839985 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:38 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-K8DDuj1hdx?4ERccvyVMW2UgubT1b?gDFz?oYZza2pR Scale = 1:37.9 1 2 3 4 5 6 7 8 15 16 4x6 6x10 4x4 1.5x4 1.5x4 4x6 10-10-010-10-0 21-8-010-10-0 -1-0-0 1-0-0 6-7-12 6-7-12 10-10-0 4-2-4 15-0-4 4-2-4 21-8-0 6-7-12 22-8-0 1-0-0 0-5-74-11-100-5-75.00 12 Plate Offsets (X,Y)-- [8:0-5-0,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.31 0.74 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.20 -0.54 0.04 0.05 (loc) 8-11 8-11 6 8-11 l/defl >999 >482 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-64(LC 17) Max Uplift 2=-83(LC 12), 6=-83(LC 13) Max Grav 2=927(LC 1), 6=927(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1572/298, 3-4=-1201/212, 4-5=-1201/212, 5-6=-1572/298 BOT CHORD 2-8=-193/1392, 6-8=-193/1392 WEBS 4-8=-67/686, 5-8=-456/180, 3-8=-456/180 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss C01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839986 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:39 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-oKnb532JNF7xrbBoTf0b2F1tH?wRKRcMTdkM40za2pQ Scale = 1:38.3 1 2 3 4 5 6 7 8 9 10 11 12 13 17 16 15 14 18 20 21 19 3x6 4x4 3x6 4x4 4x4 4x4 5-3-85-3-8 6-7-81-4-0 7-11-01-3-8 10-7-02-8-0 15-10-05-3-0 -1-0-0 1-0-0 5-3-8 5-3-8 6-7-8 1-4-0 7-11-0 1-3-8 15-10-0 7-11-0 16-10-0 1-0-0 0-8-116-0-00-8-118.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-3], [12:0-3-4,0-0-3] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.14 0.22 0.30 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.06 0.01 0.02 (loc) 16-17 16-17 2 17-24 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 76 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 18 REACTIONS.All bearings 5-6-8 except (jt=length) 2=0-3-8. (lb) - Max Horz 2=115(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 14 except 15=-103(LC 17) Max Grav All reactions 250 lb or less at joint(s) 15, 14 except 2=525(LC 1), 12=274(LC 1), 16=530(LC 19), 16=389(LC 1), 12=274(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-465/49 BOT CHORD 2-17=-25/454, 16-17=-25/454 WEBS 4-20=-400/102, 18-20=-400/97, 18-21=-391/92, 19-21=-401/100, 16-19=-289/95 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 14 except (jt=lb) 15=103. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss C02 Truss Type Common Qty 1 Ply 1 TG105 Job Reference (optional) I50839987 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:41 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-kjuLWl3ZvsNf5vLBa4238g672oaToOQfxxDS9uza2pO Scale = 1:38.1 1 2 3 4 5 8 7 6 9 10 4x8 4x8 1.5x4 4x6 7-11-07-11-0 15-10-07-11-0 -1-0-0 1-0-0 7-11-0 7-11-0 15-10-0 7-11-0 16-10-0 1-0-0 0-8-116-0-00-8-118.00 12 Plate Offsets (X,Y)-- [6:0-4-10,0-2-0], [8:0-4-10,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.58 0.37 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.17 0.01 0.05 (loc) 7-8 7-8 6 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x6 SP DSS *Except* 3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-131(LC 8) Max Uplift 8=-59(LC 10), 6=-59(LC 11) Max Grav 8=709(LC 18), 6=709(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-757/94, 3-4=-757/94, 2-8=-644/164, 4-6=-644/164 BOT CHORD 7-8=0/561, 6-7=0/561 WEBS 3-7=0/369 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss D01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839988 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:42 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-CvSjk54CgAWWi3wN8oaIgufOmC?BXsRp9bz0hKza2pN Scale = 1:31.2 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x4 3x6 12-8-012-8-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-8-114-11-60-8-118.00 12 Plate Offsets (X,Y)-- [12:0-3-12,0-1-8], [20:0-3-12,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.13 0.02 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 10 11 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 12-8-0. (lb) - Max Horz 20=-109(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss D02 Truss Type Common Qty 1 Ply 1 TG105 Job Reference (optional) I50839989 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:43 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-g606xR5qRUeNKDVZiV5XD5CWacIDGJGyOFiZDnza2pM Scale = 1:31.4 1 2 3 4 5 8 7 64x8 4x8 1.5x4 4x4 6-4-06-4-0 12-8-06-4-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-8-114-11-60-8-118.00 12 Plate Offsets (X,Y)-- [6:0-4-10,0-2-0], [8:0-4-10,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.38 0.23 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.07 0.01 0.02 (loc) 7-8 7-8 6 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x6 SP DSS *Except* 3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-110(LC 8) Max Uplift 8=-51(LC 10), 6=-51(LC 11) Max Grav 8=562(LC 1), 6=562(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-533/79, 3-4=-533/79, 2-8=-510/146, 4-6=-510/146 BOT CHORD 7-8=0/352, 6-7=0/352 WEBS 3-7=0/266 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss E01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839990 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:45 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-dU8sM764z5u5ZWfypw7?IWHv?Q1wkDKFsZBgIfza2pK Scale = 1:27.0 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x4 3x6 10-7-010-7-0 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-114-3-00-8-118.00 12 Plate Offsets (X,Y)-- [12:0-3-12,0-1-8], [20:0-3-12,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.13 0.02 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-7-0. (lb) - Max Horz 20=-95(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839991 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:46 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-5hiEZS7ikP0yBgD8NdeErkq4MpL8TgNO4DxDq6za2pJ Scale = 1:13.9 1 2 3 4 5 9 8 7 6 10 11 12 4x6 2x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 3x4 4-6-44-6-4 -1-1-12 1-1-12 4-6-4 4-6-4 0-8-110-7-102-6-40-3-80-10-122-6-44.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.15 0.08 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.01 -0.00 0.01 (loc) 8 8 11 8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-1-8, 11=0-1-8 Max Horz 9=56(LC 9) Max Uplift 9=-55(LC 8), 11=-27(LC 12) Max Grav 9=263(LC 19), 11=140(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 9, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 9, 11. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 11. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J02 Truss Type Monopitch Qty 5 Ply 1 TG105 Job Reference (optional) I50839992 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:47 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-ZtGcno8KVi8ppqoKxL9TNxMF6DhKC65YJtgnMYza2pI Scale = 1:13.9 1 2 3 5 4 6 7 8 4x6 2x4 2x4 2x4 3x4 4-6-44-6-4 -1-1-12 1-1-12 4-6-4 4-6-4 0-8-110-7-102-6-40-3-80-10-122-6-44.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.15 0.09 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.01 -0.00 0.00 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-1-8, 7=0-1-8 Max Horz 5=56(LC 9) Max Uplift 5=-55(LC 8), 7=-27(LC 12) Max Grav 5=263(LC 19), 7=140(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J03 Truss Type Monopitch Qty 2 Ply 1 TG105 Job Reference (optional) I50839993 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:47 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-ZtGcno8KVi8ppqoKxL9TNxMDWDg5C5jYJtgnMYza2pI Scale = 1:17.4 1 2 3 5 4 6 7 8 4x6 3x4 3x4 3x4 3x4 5-10-45-10-4 -1-1-12 1-1-12 5-10-4 5-10-4 1-0-110-7-102-11-100-3-80-10-122-11-104.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.26 0.17 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.04 0.00 0.00 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-1-8, 7=0-1-8 Max Horz 5=65(LC 9) Max Uplift 5=-58(LC 8), 7=-37(LC 12) Max Grav 5=317(LC 19), 7=203(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-271/152 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J04 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839994 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:48 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-13p?_89yG0GgQ_NXV2hiw9vQsd2SxaFhYXQKu_za2pH Scale = 1:18.3 1 2 3 4 5 6 11 10 9 8 7 12 4x6 3x4 -1-1-12 1-1-12 5-10-4 5-10-4 1-0-32-11-104.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.15 0.03 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 5-10-4. (lb) - Max Horz 11=88(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 7, 8, 11, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 7, 8, 11, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 8, 11, 9, 10. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J05 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839995 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:49 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-VGNNCU9b1JOX28yj2mCxSMSca1Oug1VrmB9tRQza2pG Scale = 1:14.6 1 2 3 4 5 6 10 9 8 7 11 1.5x4 1.5x4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 3x6 -1-0-0 1-0-0 5-8-0 5-8-0 0-4-62-3-04.00 12 Plate Offsets (X,Y)-- [10:0-1-5,1-5-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.09 0.02 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-8-0. (lb) - Max Horz 2=67(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 7, 2, 8, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 8, 9, 10. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J06 Truss Type Monopitch Qty 6 Ply 1 TG105 Job Reference (optional) I50839996 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:50 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-zSxlPqADodWNgHXvcTjA?a_idRgfPUx_?rvRztza2pF Scale = 1:14.6 1 2 3 4 8 1.5x4 3x4 1.5x4 -1-0-0 1-0-0 5-8-0 5-8-0 0-4-62-3-01-11-80-3-82-3-04.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.39 0.30 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.12 0.00 0.04 (loc) 4-7 4-7 2 4-7 l/defl >999 >532 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=67(LC 11) Max Uplift 2=-58(LC 8), 4=-30(LC 12) Max Grav 2=290(LC 19), 4=232(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss J07 Truss Type Monopitch Qty 4 Ply 1 TG105 Job Reference (optional) I50839997 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:51 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-ReV7dABrZxeEHR66ABEPYnXxIq4G8xB8EVe_VJza2pE Scale = 1:8.8 1 2 3 4 2x4 1-0-01-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-71-0-78.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.08 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 7 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 3=Mechanical Max Horz 4=-237(LC 16), 3=237(LC 16) Max Uplift 3=-27(LC 10) Max Grav 3=140(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-156/274 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. PROVIDE ANCHORAGE, DESIGNED BY OTHERS, AT BEARINGS TO RESIST MAX. UPLIFT AND MAX HORZ. REACTIONS SPECIFIED BELOW. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss M01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50839998 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:52 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-vq3VqWCTKEm5vbhIkule4?45rEPEtN9HT9OY1lza2pD Scale = 1:22.6 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 2x4 4x6 3x4 -1-1-12 1-1-12 8-6-4 8-6-4 1-0-33-10-44.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.15 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.00 (loc) 2 1 9 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 8-6-4. (lb) - Max Horz 15=118(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 15, 9, 10, 11, 12, 13, 14 Max Grav All reactions 250 lb or less at joint(s) 15, 9, 10, 11, 12, 13, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9, 10, 11, 12, 13, 14. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss M02 Truss Type Monopitch Qty 7 Ply 1 TG105 Job Reference (optional) I50839999 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:53 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-O1dt2sD54YuyXlGUHcGtdCcGRejIcobQhp75aCza2pC Scale = 1:21.2 1 2 3 4 7 6 5 8 9 10 4x6 3x4 3x4 1.5x4 4x4 3x4 3x4 4-3-24-3-2 8-6-44-3-2 -1-1-12 1-1-12 4-3-2 4-3-2 8-6-4 4-3-2 0-8-110-7-103-10-40-3-80-10-123-10-44.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.16 0.18 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.03 0.01 0.00 (loc) 5-6 5-6 9 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-1-8, 9=0-1-8 Max Horz 7=83(LC 9) Max Uplift 7=-65(LC 8), 9=-56(LC 12) Max Grav 7=427(LC 19), 9=332(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-453/61, 2-7=-395/136 BOT CHORD 5-6=-112/397 WEBS 3-5=-386/125, 2-6=0/404, 4-9=-338/104 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7, 9. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 9. March 18,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200487-2200487A Truss A01 Truss Type GABLE Qty 1 Ply 1 TG105 Job Reference (optional) I50840000 8.530 s Dec 6 2021 MiTek Industries, Inc. Thu Mar 17 10:45:29 2022 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:KIESbp2fffc24BoOoCrp_OzcezG-4PAp?ew2kAtMe3QttZrFf8d6UzUa_yPuA4Jqjbza2pa Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516 17 18 19 20 21 33 32 30 29 28 27 26 25 24 2322 37 36 35 34 38 47 48 31 3x6 4x4 4x6 3x6 3x6 4x4 4x4 4x6 4x4 4x8 9-4-89-4-8 15-10-06-5-8 18-5-82-7-8 27-10-09-4-8 -1-0-0 1-0-0 7-11-0 7-11-0 13-11-0 6-0-0 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-8-1110-0-00-8-118.00 12 Plate Offsets (X,Y)-- [14:0-2-4,0-2-4], [20:0-1-9,0-0-6] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.42 0.38 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.18 0.03 0.08 (loc) 33-45 33-45 2 33-45 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 168 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 20-23. JOINTS 1 Brace at Jt(s): 34, 36 REACTIONS.All bearings 12-3-8 except (jt=length) 2=0-3-8, 31=0-3-8. (lb) - Max Horz 2=192(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 20, 2, 29, 28, 27, 26, 25, 24, 23 except 30=-192(LC 10) Max Grav All reactions 250 lb or less at joint(s) 29, 28, 27, 26, 25, 24, 23 except 20=315(LC 1), 2=830(LC 18), 30=323(LC 18), 31=433(LC 3), 20=315(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-939/84, 5-6=-346/81, 10-11=-255/94, 13-15=-254/47, 15-16=-261/49, 16-17=-267/51, 17-18=-275/54, 18-19=-290/55, 19-20=-320/62 BOT CHORD 2-33=-80/831, 31-33=-80/831, 30-31=-80/831, 29-30=-53/268, 28-29=-53/268, 27-28=-53/268, 26-27=-53/268, 25-26=-53/268, 24-25=-53/268, 23-24=-53/268, 20-23=-53/268 WEBS 5-33=0/365, 5-37=-722/176, 36-37=-685/155, 35-36=-729/180, 34-35=-749/193, 34-38=-702/160, 30-38=-716/171 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 2, 29, 28, 27, 26, 25, 24, 23, 20 except (jt=lb) 30=192. March 18,2022 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths