HomeMy WebLinkAboutM003.0 - TRUSS SEALS16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. RE: Design Code: IRC2021/TPI2014 Wind Code: ASCE 7-16 Wind Speed: 115 mph Roof Load: 40.0 psf Design Program: MiTek 20/20 8.5 1 of 1 This package includes 19 individual, dated Truss Design Drawings and 0 Additional Drawings. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf November 03, 2021 Liu, Xuegang The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by 84 Components - 0783. Truss Design Engineer's Name: Liu, XuegangMy license renewal date for the state of Indiana is July 31, 2022. 2200286-2200286A TG125 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the designparameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. Site Information: Lot/Block: 125Customer: Pyatt Builders Project Name: 2200286-2200286A Subdivision: The Grove at LegacyAddress: State: INCity: Carmel Model: Soho No. Seal# Truss Name Date 1 I48644634 A01 11/3/2021 2 I48644635 A02 11/3/2021 3 I48644636 A03 11/3/2021 4 I48644637 A04 11/3/2021 5 I48644638 B01 11/3/2021 6 I48644639 B02 11/3/2021 7 I48644640 C01 11/3/2021 8 I48644641 C02 11/3/2021 9 I48644642 D01 11/3/2021 10 I48644643 D02 11/3/2021 11 I48644644 E01 11/3/2021 12 I48644645 M01 11/3/2021 13 I48644646 M02 11/3/2021 14 I48644647 M03 11/3/2021 15 I48644648 M04 11/3/2021 16 I48644649 M05 11/3/2021 17 I48644650 M06 11/3/2021 18 I48644651 M07 11/3/2021 19 I48644652 M08 11/3/2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss A01 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644634 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:21 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-oXkZCSXlCocfklfp2aay4TuKtOn2oNkBOXncxwyN3zu Scale = 1:66.8 1 2 3 4 5 6 7 8 9 20 19 17 16 15 14 13 12 11 10 51 52 53 54 18 55 56 3x8 MT18HS 4x8 3x4 3x6 6x6 3x4 3x4 3x4 6x6 3x4 3x4 3x4 3x4 3x4 3x4 3x4 10-4-010-4-0 15-10-05-6-0 17-6-01-8-0 27-10-010-4-0 -0-11-0 0-11-0 6-11-13 6-11-13 13-11-0 6-11-3 20-10-3 6-11-3 27-10-0 6-11-13 28-9-0 0-11-0 0-7-59-10-100-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-11], [5:0-1-12,0-1-8], [8:Edge,0-3-3] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.47 0.64 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.28 -0.51 0.03 0.06 (loc) 20-47 20-47 2 20-47 l/defl >681 >372 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 194 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-16 REACTIONS.All bearings 12-3-8 except (jt=length) 2=0-3-8, 18=0-3-8. (lb) - Max Horz 2=-182(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 17, 11, 10 except 16=-133(LC 15) Max Grav All reactions 250 lb or less at joint(s) 17, 15, 14, 13, 12, 11, 10, 18 except 2=888(LC 26), 16=930(LC 2), 8=340(LC 35), 8=279(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-944/77, 3-5=-773/105, 7-8=-385/49 BOT CHORD 2-20=-93/870, 18-20=-7/355, 17-18=-7/355, 16-17=-7/355, 15-16=0/262, 14-15=0/262, 13-14=0/262, 12-13=0/262, 11-12=0/262, 10-11=0/262, 8-10=0/262 WEBS 5-16=-671/81, 7-16=-380/207, 5-20=-70/777, 3-20=-424/204 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 17, 11, 10, 8 except (jt=lb) 16=133.November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss A02 Truss Type Common Qty 17 Ply 1 TG125 Job Reference (optional) I48644635 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-GjIxQoYOz6kWMvE?bI6BcgRVro5dXs2LdBWATNyN3zt Scale = 1:61.9 1 2 3 4 5 6 7 89 12 11 10 19 20 21 22 23 24 25 3x8 MT18HS 4x6 3x8 MT18HS 6x6 3x4 3x4 1.5x4 3x4 1.5x4 6x6 10-4-010-4-0 17-6-07-1-15 27-10-010-4-0 -0-11-0 0-11-0 6-11-13 6-11-13 13-11-0 6-11-3 20-10-3 6-11-3 27-10-0 6-11-13 28-9-0 0-11-0 0-7-59-10-100-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-15], [8:Edge,0-2-15] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.46 0.68 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.27 -0.49 0.03 0.05 (loc) 12-15 12-15 8 12-15 l/defl >999 >677 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 109 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-182(LC 12) Max Uplift 2=-67(LC 14), 8=-67(LC 15) Max Grav 2=1336(LC 26), 8=1336(LC 27) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1706/109, 3-5=-1535/139, 5-7=-1536/139, 7-8=-1706/109 BOT CHORD 2-12=-118/1495, 10-12=0/1006, 8-10=-9/1372 WEBS 5-10=-73/734, 7-10=-404/202, 5-12=-73/733, 3-12=-404/202 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss A03 Truss Type Roof Special Qty 3 Ply 1 TG125 Job Reference (optional) I48644636 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-C6QhrUZeVj_EbCOOjj8fi5WrvcsE?ine4U?GXFyN3zr Scale = 1:62.2 1 2 3 4 5 6 7 8 9 10 16 15 12 11 14 13 25 26 6x10 4x6 3x4 6x6 6x6 3x6 6x6 6x6 4x4 6x8 4x6 4x8 3x6 1.5x4 1.5x4 6-11-136-11-13 14-0-127-0-15 17-7-83-6-12 22-8-75-0-15 27-10-05-1-9 -0-11-0 0-11-0 6-11-13 6-11-13 13-11-0 6-11-3 17-7-8 3-8-8 22-8-7 5-0-15 27-10-0 5-1-9 28-9-0 0-11-0 0-7-59-10-100-7-52-0-08.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-15], [4:0-2-4,Edge], [9:Edge,0-2-15], [13:0-2-8,0-2-0], [14:0-2-12,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.42 0.35 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.17 0.09 0.04 (loc) 13-14 15-16 9 13-14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 142 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-15,6-12,12-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-0-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 10-0-0 oc bracing: 14-15, 12-13 JOINTS 1 Brace at Jt(s): 14, 13 REACTIONS. (size)2=0-3-8, 9=0-3-8 Max Horz 2=182(LC 13) Max Uplift 2=-67(LC 14), 9=-67(LC 15) Max Grav 2=1168(LC 2), 9=1168(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1590/85, 3-5=-1368/108, 5-6=-1303/130, 6-8=-1847/89, 8-9=-1617/83 BOT CHORD 2-16=-101/1239, 9-11=0/1274, 5-14=-34/1073, 13-14=0/1471, 6-13=0/596 WEBS 14-16=-123/1246, 3-14=-293/143, 6-14=-717/109, 11-13=-5/1344, 8-11=-464/59 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss A04 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644637 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-8UYSGAbu1LExqWYnq8A7nWcAdPT3TdiwXoUNc8yN3zp Scale = 1:66.8 1 2 3 4 5 6 7 8 9 22 21 20 19 18 17 16 15 14 13 12 11 10 51 52 53 54 55 56 57 3x8 MT18HS 4x8 3x4 3x6 6x6 3x4 3x4 3x4 6x6 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 10-4-010-4-0 12-4-82-0-8 17-6-05-1-8 27-10-010-4-0 -0-11-0 0-11-0 6-11-13 6-11-13 13-11-0 6-11-3 20-10-3 6-11-3 27-10-0 6-11-13 28-9-0 0-11-0 0-7-59-10-100-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-11], [5:0-1-12,0-1-8], [8:Edge,0-3-3] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.47 0.65 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.27 -0.48 0.03 0.06 (loc) 22-47 22-47 2 22-47 l/defl >567 >311 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 197 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-16 REACTIONS.All bearings 15-5-8 except (jt=length) 2=0-3-8, 20=0-3-8, 20=0-3-8. (lb) - Max Horz 2=182(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 11, 10, 20 except 16=-120(LC 15), 20=-189(LC 21) Max Grav All reactions 250 lb or less at joint(s) 19, 18, 17, 15, 14, 13, 12, 11, 10 except 2=901(LC 26), 16=939(LC 2), 8=332(LC 35), 8=276(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-967/68, 3-5=-796/95, 7-8=-375/53 BOT CHORD 2-22=-86/889, 20-22=-6/359, 19-20=-6/359, 18-19=-6/359, 17-18=-6/359, 16-17=-6/359, 15-16=0/254, 14-15=0/254, 13-14=0/254, 12-13=0/254, 11-12=0/254, 10-11=0/254, 8-10=0/254 WEBS 5-16=-707/66, 7-16=-380/207, 5-22=-52/821, 3-22=-422/205 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 11, 10, 8 except (jt=lb) 16=120, 20=189. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss B01 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644638 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-Z3DauBdnJGdWh_HMWGkqP9EoMdeKg3ENEmj1DTyN3zm Scale = 1:37.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 31 32 4x4 3x4 6x6 3x4 21-8-021-8-0 -0-11-0 0-11-0 10-10-0 10-10-0 21-8-0 10-10-0 22-7-0 0-11-0 0-4-94-10-120-4-95.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.05 0.04 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 16 17 16 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 21-8-0. (lb) - Max Horz 2=61(LC 20) Max Uplift All uplift 100 lb or less at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 10-10-0, Corner(3R) 10-10-0 to 13-10-0, Exterior(2N) 13-10-0 to 22-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss B02 Truss Type Common Qty 3 Ply 1 TG125 Job Reference (optional) I48644639 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-1Fnz5XeP4ZlNJ8rY3zF3xMmuC1pGPTaWSQSblvyN3zl Scale = 1:37.7 1 2 3 4 5 6 7 8 15 16 17 18 19 20 3x6 6x10 4x4 1.5x4 1.5x4 3x6 10-10-010-10-0 21-8-010-10-0 -0-11-0 0-11-0 6-7-1 6-7-1 10-10-0 4-2-15 15-0-15 4-2-15 21-8-0 6-7-1 22-7-0 0-11-0 0-4-94-10-120-4-95.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [6:0-1-12,0-1-8], [8:0-5-0,0-3-4] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.37 0.76 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.21 -0.45 0.04 0.07 (loc) 8-11 8-14 6 8-11 l/defl >999 >572 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-1-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-61(LC 21) Max Uplift 2=-65(LC 16), 6=-65(LC 17) Max Grav 2=922(LC 2), 6=922(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1607/188, 3-4=-1232/127, 4-5=-1232/127, 5-6=-1607/188 BOT CHORD 2-8=-110/1447, 6-8=-115/1447 WEBS 4-8=-11/713, 5-8=-472/152, 3-8=-472/151 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 10-10-0, Exterior(2R) 10-10-0 to 13-10-0, Interior(1) 13-10-0 to 22-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss C01 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644640 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:31 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-VSLLJtf1rttExHQkdhmIUaJ?fQDe8yjgh4C8HLyN3zk Scale = 1:37.7 1 2 3 4 5 9 8 7 6 23 24 25 26 27 6x6 6x8 4x6 7-11-07-11-0 10-3-82-4-8 15-10-05-6-8 -0-11-0 0-11-0 7-11-0 7-11-0 15-10-0 7-11-0 16-9-0 0-11-0 0-7-55-10-100-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-15], [4:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.58 0.49 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.24 0.03 0.09 (loc) 9-19 9-19 2 9-19 l/defl >980 >530 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-6-8 except (jt=length) 2=0-3-8. (lb) - Max Horz 2=-108(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 4, 8, 8, 7 except 6=-165(LC 15) Max Grav All reactions 250 lb or less at joint(s) 8, 7 except 2=772(LC 26), 4=632(LC 26), 6=300(LC 33), 4=483(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-787/87, 3-4=-832/100 BOT CHORD 2-9=-17/628, 8-9=-17/628, 7-8=-17/628, 6-7=-17/628, 4-6=-17/628 WEBS 3-9=0/405 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-11-0, Exterior(2R) 7-11-0 to 10-11-0, Interior(1) 10-11-0 to 16-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 8, 7, 4 except (jt=lb) 6=165. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss C02 Truss Type Common Qty 1 Ply 1 TG125 Job Reference (optional) I48644641 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-zevjWDgfcB?5YR?wBOHX0nsBTqY2tPrpwkxipnyN3zj Scale = 1:37.2 1 2 3 4 5 6 13 14 15 16 17 18 6x6 6x6 1.5x4 4x6 7-11-07-11-0 15-10-07-11-0 -0-11-0 0-11-0 7-11-0 7-11-0 15-10-0 7-11-0 16-9-0 0-11-0 0-7-55-10-100-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-15], [4:Edge,0-2-15] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.57 0.55 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.21 0.03 0.10 (loc) 6-9 6-9 2 6-9 l/defl >999 >893 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 50 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=108(LC 13) Max Uplift 2=-44(LC 14), 4=-44(LC 15) Max Grav 2=783(LC 26), 4=783(LC 27) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-857/79, 3-4=-857/79 BOT CHORD 2-6=0/655, 4-6=0/655 WEBS 3-6=0/455 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-11-0, Exterior(2R) 7-11-0 to 10-11-0, Interior(1) 10-11-0 to 16-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss D01 Truss Type Common Qty 2 Ply 1 TG125 Job Reference (optional) I48644642 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-RqT5kZgHNU7yAba7l6omZ?OOgEyhcsjy8OhFMEyN3zi Scale = 1:30.4 1 2 3 4 5 6 13 14 6x6 6x6 1.5x4 4x6 6-4-06-4-0 12-8-06-4-0 -0-11-0 0-11-0 6-4-0 6-4-0 12-8-0 6-4-0 13-6-0 0-10-0 0-7-54-10-00-7-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-3], [4:Edge,0-3-3] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.42 0.26 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.08 0.01 0.04 (loc) 6-12 6-12 2 6-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=88(LC 13) Max Uplift 2=-38(LC 14), 4=-37(LC 15) Max Grav 2=562(LC 2), 4=556(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-585/90, 3-4=-585/90 BOT CHORD 2-6=0/406, 4-6=0/406 WEBS 3-6=0/285 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-0, Exterior(2R) 6-4-0 to 9-4-0, Interior(1) 9-4-0 to 13-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss D02 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644643 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-v11Txvhv8oFpol9JIpJ?6CxegeMYLKY6N2QougyN3zh Scale = 1:29.2 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 4x4 4x6 4x6 12-8-012-8-0 -0-11-0 0-11-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-7-54-10-00-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 10 10 10 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-8-0. (lb) - Max Horz 2=-89(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-4-0, Exterior(2N) 2-4-0 to 6-4-0, Corner(3R) 6-4-0 to 9-4-0, Exterior(2N) 9-4-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 16, 17, 18, 14, 13, 12. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss E01 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644644 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-sP8EMajAgPVX13JiQEMTBd0_NR1rpE5PrMvvyZyN3zf Scale = 1:25.2 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 4x4 4x6 4x6 10-7-010-7-0 -0-11-0 0-11-0 5-3-8 5-3-8 10-7-0 5-3-8 11-6-0 0-11-0 0-7-54-1-100-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.04 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 8 9 8 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-7-0. (lb) - Max Horz 2=-76(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 5-3-8, Corner(3R) 5-3-8 to 8-3-8, Exterior(2N) 8-3-8 to 11-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11, 10. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M01 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644645 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:37 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-KcicZwjoRjdNfCuu_xtijrZ7UrL4YhwY30fSV?yN3ze Scale = 1:18.4 1 2 3 4 5 6 10 9 8 7 11 3x4 -0-11-0 0-11-0 8-8-0 8-8-0 0-3-113-2-64.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.17 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-8-0. (lb) - Max Horz 2=94(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 7, 2, 8, 9 except 10=435(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-10=-326/294 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 8, 9, 10. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M02 Truss Type Monopitch Qty 7 Ply 1 TG125 Job Reference (optional) I48644646 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-ooG_nGkQC1lEGMT4XfOyG25DRFadH6GiIgO01RyN3zd Scale = 1:19.6 1 2 3 4 5 9 1.5x4 4x6 1.5x4 3x4 8-8-08-8-0 -0-11-0 0-11-0 4-10-10 4-10-10 8-8-0 3-9-6 0-3-113-2-62-10-140-3-83-2-64.00 12 Plate Offsets (X,Y)-- [2:0-1-8,0-0-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.54 0.60 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.30 0.01 0.03 (loc) 5-8 5-8 5 5-8 l/defl >705 >336 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 5=0-1-8 Max Horz 2=94(LC 15) Max Uplift 2=-58(LC 12), 5=-41(LC 16) Max Grav 2=399(LC 2), 5=389(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-568/199 BOT CHORD 2-5=-256/537 WEBS 3-5=-580/250 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 5. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M03 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644647 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-G_qM_cl2zKt5uW1H5MvBpGeV4f250blrXK8ZZuyN3zc Scale = 1:17.5 1 2 3 4 5 6 11 10 9 8 7 3x4 3x4 -0-9-12 0-9-12 5-10-4 5-10-4 0-11-82-10-154.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.07 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-10-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 5-10-4. (lb) - Max Horz 11=82(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 11, 7, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 11, 7, 8, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-9-12 to 2-2-4, Exterior(2N) 2-2-4 to 5-8-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7, 8, 9, 10. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M04 Truss Type Monopitch Qty 2 Ply 1 TG125 Job Reference (optional) I48644648 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-kBOlCymgke?yWgcTf4QQLTBan3Mnl2S_l_t76KyN3zb Scale = 1:18.9 1 2 3 5 4 3x4 3x4 3x4 3x6 -0-9-12 0-9-12 5-10-4 5-10-4 0-11-82-10-152-7-70-3-82-10-154.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MR 0.42 0.24 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.07 0.00 0.01 (loc) 4-5 4-5 4 4-5 l/defl >999 >929 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-10-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 4=0-1-8 Max Horz 5=82(LC 13) Max Uplift 5=-47(LC 12), 4=-29(LC 16) Max Grav 5=315(LC 23), 4=258(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-276/168 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-9-12 to 2-2-4, Interior(1) 2-2-4 to 5-8-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M05 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644649 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-CNy7PInIUy7p7qBfDnxfuhjqUSjhUVA8_edgemyN3za Scale = 1:14.3 1 2 3 4 5 8 7 6 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 -0-11-0 0-11-0 5-8-0 5-8-0 0-3-112-2-64.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-8-0. (lb) - Max Horz 2=62(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=274(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 5-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M06 Truss Type Monopitch Qty 6 Ply 1 TG125 Job Reference (optional) I48644650 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-gZWVdenwFFFgl_mrmVTuQuGvds_KDyyHDIMDACyN3zZ Scale = 1:14.3 1 2 3 4 1.5x4 3x4 1.5x4 5-8-05-8-0 -0-11-0 0-11-0 5-8-0 5-8-0 0-3-112-2-61-10-140-3-82-2-64.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.47 0.42 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.11 0.00 0.04 (loc) 4-7 4-7 2 4-7 l/defl >999 >580 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=62(LC 15) Max Uplift 2=-49(LC 12), 4=-26(LC 16) Max Grav 2=311(LC 23), 4=257(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 5-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M07 Truss Type GABLE Qty 1 Ply 1 TG125 Job Reference (optional) I48644651 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:43 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-8m3tq_oZ0ZNXN7L2KC_7z6pAHGQFyPmRSy6nifyN3zY Scale = 1:15.1 1 2 3 4 5 9 8 7 6 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 -0-9-12 0-9-12 4-6-4 4-6-4 0-11-82-5-104.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.06 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-6-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 4-6-4. (lb) - Max Horz 9=68(LC 15) Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-9-12 to 2-2-4, Exterior(2N) 2-2-4 to 4-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 7, 8. November 3,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2200286-2200286A Truss M08 Truss Type Monopitch Qty 5 Ply 1 TG125 Job Reference (optional) I48644652 8.520 s Aug 27 2021 MiTek Industries, Inc. Wed Nov 3 00:24:44 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:21s5VRR?OxG_WPECwA1higz445d-dydF1KpBntWO_HwEuwVMWJLJwgkMhrRagcrKF5yN3zX Scale = 1:15.1 1 2 3 5 4 3x4 3x4 3x4 3x4 4-6-44-6-4 -0-9-12 0-9-12 4-6-4 4-6-4 0-11-82-5-102-2-20-3-82-5-104.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MR 0.22 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 0.00 0.00 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-6-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 4=0-1-8 Max Horz 5=68(LC 15) Max Uplift 5=-43(LC 12), 4=-22(LC 16) Max Grav 5=279(LC 23), 4=192(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-9-12 to 2-2-4, Interior(1) 2-2-4 to 4-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. November 3,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths