HomeMy WebLinkAboutRichard Cotton Engineering 05-05-22.pdf76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com May 5, 2022 Illumine Industries 39111 Paseo Padre Parkway Suite 313 Fremont, CA 94538 Re: Engineering Services Cotton Residence 3812 Wolf Creek Circle, Carmel IN 4.440 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 dimensional lumber at 16” on center. Roof Material: Composite Asphalt Shingles Roof Slopes: 45 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used  Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF  Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf  Live Load = 20 psf (reducible) – 0 psf at locations of solar panels  Ground Snow Load = 20 psf  Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 90 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2012 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Sunmodo installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. Connection on the roof is utilizing (4) 3” self-tapping screws into the existing decking to resist uplift forces. Contractor to verify installation to be performed in accordance with the Sunmodo recommendations. Pull out values per screw are based on National Design Specification values for CDX plywood and are identified as 208 lbs/inch. Based on ½” sheathing the value per screw would be 104 lbs providing 416 lbs uplift resistance per attachment. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2012 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Indiana License No. PE11900440 Date Signed 5/5/2022 UM MSP INV AC VICINITY MAP ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY SHEET CATALOG INDEX NO. DESCRIPTION T-01 COVER PAGE S-01 MOUNTING DETAIL S-02 STRUCTURAL DETAIL E-01 SINGLE LINE DIAGRAM PL-01 WARNING PLACARDS SS SPEC SHEET(S) SITE PLAN LAYOUT (E) MAIN SERVICE PANEL(INTERIOR) (E) UTILITY METER(EXTERIOR) (N) PV INVERTER (EXTERIOR) CONDUIT RUN PHOTOVOLTAIC ARRAY ON THE ROOF RICHARD COTTON - 4.440kW DC, 3.800kW AC COVER PAGE T-01 SCALE:1/32" = 1'-0" 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN Date Signed 5/5/2022 AERIAL VIEW ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY MOUNTING DETAIL S-01 ALUMINIUM RAILS SCALE:1"=10'-0" ARRAY MP-01 NOTE:PENETRATIONS ARE STAGGERED INSTALLATION NOTES 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4.ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 1-1/2" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ROOF ACCESS PATHWAYS AND SETBACKS: IFC 605.11.3.2.1 RESIDENTIAL BUILDINGS WITH HIP ROOF LAYOUTS. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3-FOOT-WIDE (914 MM) CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION ON THE BUILDING CAPABLE OF SUPPORTING THE LIVE LOAD OF FIRE FIGHTERS ACCESSING THE ROOF. IFC 605.11.3.2.2RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE. PANELS/MODULES INSTALLED ON Date Signed 5/5/2022 MODULE END CLAMP MODULE MID CLAMP ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY STRUCTURAL DETAIL S-02 DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 12 40.78 489.36 MID-CLAMP 20 0.050 1.00 END-CLAMP 8 0.050 0.40 RAIL LENGTH 84 0.680 57.12 SPLICE BAR 4 0.360 1.44 NANOMOUNT DECKING 25 1.35 33.75 TOTAL WEIGHT OF THE SYSTEM (LBS) 583.07 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 237.92 WEIGHT PER SQ. FT.(LBS) 2.45 WEIGHT PER PENETRATION (LBS) 23.32 MID-CLAMP AND END-CLAMP ANATOMY GROUNDING LUG MID CLAMP ASSEMBLY MODULE FRAME RAIL MODULE TO MODULE & MODULE TO RAIL GROUNDING MID-CLAMP SCALE: NTS GROUNDING DETAILS SELF-DRILLING SCREW SCALE: NTS RAIL TO RAIL T-BOLT ATTACHMENT DETAIL-NANOMOUNT DECKING SUNMODO RAIL SMR INTERNAL SPLICE K10421-001 MODULES DATA LG NEON LG370N1K-E6 MODULE DIMS 69.60"x41.02"x1.57" LAG SCREWS (4)3" SELF-TAPPING SCREW SCALE:NTS METER#:DUKE ENERGY 318 602 772 SUPPLY SIDE TAP (E)200A END FED MAIN PANEL UTILITY GRID (E)200A MAIN BREAKER (E) GROUND ELECTRODE EXISTING 120/240V 1PH 60HZ M (N)JUNCTION BOX 3 2 1 PV MODULES G (N)LG NEON LG370N1K-E6,370W MODULES 12 MODULES WIRED IN (1) SERIES OF 12 MODULES SOLAREDGE POWER OPTIMIZERS 3 (N)SOLAREDGE TECHNOLOGIES SE3800H-US(240V), 3800W INVERTER INVERTER-1 DC DISCO DC AC LOAD RATED DC DISCONNECT & AFCI (N)60A AC DISCONNECT SQUARE D D222NRB AC DISCONNECT FUSED 60A, 120/240V, 2P 20A FUSE SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 4440W, AC SYSTEM SIZE - 3800W ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY SINGLE LINE DIAGRAM E-01 INVERTER-1 SPECIFICATIONS MODEL SOLAREDGE TECHNOLOGIES SE3800H-US(240V) UM MSP INV AC ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY WARNING PLACARDS PL-01 ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN WARNING: ! ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION SOLAR PHOTOVOLTAIC ARRAY ON THE ROOF WARNING PLACARD 25 240 AMPS AC VAC (E) MAIN SERVICE PANEL(INTERIOR) (E) UTILITY METER (EXTERIOR) (N) PV INVERTER (EXTERIOR) (N) AC DISCONNECT 3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 (EXTERIOR) WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION PER CODE: NEC 690.13 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ! WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX PER CODE: NEC690.31(G)(3) SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY MODULE SPEC SHEET SS-01 SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY INVERTER SPEC SHEET SS-02 SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY INVERTER SPEC SHEET SS-03 SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY OPTIMIZER SPEC SHEET SS-04 SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY MOUNT SPEC SHEET SS-05 SPEC SHEET ADDRESS:3812 WOLF CREEK CIRCLE, CARMEL, IN 46033 39.933943, -86.100014 APN: 291-408-304-012-000-018 CUSTOMER INFORMATION NAME:RICHARD COTTON DATE:4/29/22 SCALE:AS NOTED REV:A AHJ:IN-CITY OF CARMEL PRN NUMBER:GRN-50620 DRAFTEDBY: S.JUSTIN QC'ED BY:N.MAHALE PAPER SIZE:17"X11" UTILITY: DUKE ENERGY RAIL SPEC SHEET SS-06 LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION PER CODE: NEC 690.54 RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 16.00 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH LABEL LOCATION POINT OF INTERCONNECTION PER CODE: NEC705.12(B)(3) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM A 15 480 MAXIMUM SYSTEM VOLTAGE(Voc) MAXIMUM CIRCUIT CURRENT(Isc) MAXIMUM RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER(IF INSTALLED) INVERTER 1 V A 15 LABEL LOCATION DC DISCONNECT PER CODE: NEC690.53 LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC690.13(B) PHOTOVOLTAIC AC DISCONNECT ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION INVERTER PER CODE: NEC 690.56(C)(3) POWER RATING 3800W MAX OUTPUT CURRENT 16A CEC WEIGHTED EFFICIENCY 99% MAX INPUT CURRENT 10.5A MAX DC VOLTAGE 480V MODULE SPECIFICATION MODEL LG NEON LG370N1K-E6 MODULE POWER @ STC 370W OPEN CIRCUIT VOLTAGE:Voc 41.4V MAX POWER VOLTAGE:Vmp 34.7V SHORT CIRCUIT CURRENT:Isc 11.23A MAX POWER CURRENT:Imp 10.68A ELECTRICAL CALCULATIONS DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK 1 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.58 X 1 = 23.20A 18.75A < 23.20A 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.71 X 0.8 = 22.72A 18.75A < 22.72A AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK 3 16 X 1 = 16 X 1.25 = 20.00A 75 X 0.87 X 1 = 65.25A 20.00A < 65.25A CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10AWG PV WIRE NONE (1) 10AWG BARE COPPER 2 3/4"IMC (2) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 3 3/4"IMC (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 NOTE: MAIN PANEL RATING:200A, MAIN BREAKER RATING:200A LINE SIDE TAP: 100% ALLOWABLE BACKFEED IS =200A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25) =16x1.25=20.00A=>PV BREAKER = 20A TOTAL REQUIRED PV BREAKER SIZE / FUSE SIZE=>20A PV BREAKER SYSTEM CHARACTERISTICS DC SYSTEM SIZE 4440W INVERTER STRING VOLTAGE:Vmp 380V MAX INVERTER SYSTEM VOLTAGE: Voc 480V MAX SHORT CIRCUIT CURRENT 15A OPERATING CURRENT 11.68A ELECTRICAL NOTES OPTIMIZER CHARACTERISTICS MODEL P401 MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 60 VDC MAX INPUT CURRENT 11.75 ADC MAX OUTPUT CURRENT 15 ADC DC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS>> · REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OF PARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER 690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a) · CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY · DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> · REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A) · CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY · DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY ELECTRICAL NOTES: 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250.122. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE NEC 310.15(B)(16). (4)3" SELF-TAPPING SCREW 6" MAX NANOMOUNT DECKING SOLAR MODULE DECK UNIRAC RAIL UNIRAC RAIL 2 X 6 RAFTERS @1'-4" SPACING COMPOSTION SHINGLE ROOF MODULE (4)3" SELF-TAPPING SCREW LOAD BEARING WALL SCALE:NTS ROOF FRAMING DETAILS RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE (914 MM) ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. IFC 605.11.3.2.3 RESIDENTIAL BUILDINGS WITH ROOF HIPS AND VALLEYS. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL BE LOCATED NO CLOSER THAN 18 INCHES (457 MM) TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL LENGTH, THE PANELS SHALL BE PERMITTED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. IFC 605.11.3.2.4 RESIDENTIAL BUILDING SMOKE VENTILATION. PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS SHALL BE LOCATED NO HIGHER THAN 3 FEET (914 MM) BELOW THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS. SITE INFORMATION - WIND SPEED: 90 MPH AND SNOW LOAD: 20 PSF SR. NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.) ROOF TYPE ATTACHMENT ROOF EXPOSURE MAX RAIL SPAN OVER HANG MP-01 178° 45° 12 237.9 COMPOSTION SHINGLE NANOMOUNT DECKING ATTIC 4'-0" 1'-6" 3' 3' 3' 4' AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING GENERAL NOTES · ELECTRIC CODE:NEC 2009 · FIRE CODE:IFC 2012 · BUILDING CODE:IBC 2012 · RESIDENTIAL CODE:IRC 2012 APPLICABLE CODES (N) AC DISCONNECT (EXTERIOR) SCOPE OF WORK GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 4440W DC, 3800W AC MODULES: (12)LG NEON LG370N1K-E6 INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3800H-US(240V) OPTIMIZER: (12)SOLAREDGE P401 POWER OPTIMIZER RESIDENCE ENGINEERING SCOPE OF WORK 1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. 2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT DRAWINGS, HE/SHE: a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN c. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN PROPERTY LINE 3' FIRE SETBACK DRIVE WAY WOLF CREEK CIR 166'-2" 157'-6" 176' 12' 35'-11" 50' 35'-11" Date Signed 5/5/2022