HomeMy WebLinkAboutLIGHT FIXTURE WP2 - PAGE 6D S A P SERIES - PLED LED/ Electrical Guide (pg. 4)
LED Source Initial Initial Initial L70 greater Starting System Max
CounT Type Source Lumens - Lumens - Lumens - }han HR Temp. Watts VolTs Input Amps
4000K CCT 3000K CCT 5000K CCT � )
80 TRA - 80 PLED® Optical 4146 -
LED Module - 525mA 4757
True Amber LED - 590nm
120 .85
66,500+ -40°F 101 277 .37
NOTES:
1) Max Input Amps is the highest of starting, operating, or open circuit currents
2) System Watts includes the source watts and all driver components.
3) Lumen values for LED Modules vary according to the distribution type
4) For Wattage and Max Input Amps showing two values, use the higher value for luminaires with lit uplight windows (-L & -M)
5) PCA and TRA LED optics not recommended for use with lit uplight window models (-L & -M)
6) Fuse value should be sufficient to protect all wiring components. For electronic driver and LED component protection, use 20KV surge suppressors.
7) L70(l OK) -TM-21 6x rule applied
WARNING: All fixtures must be installed in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury.
660 West Avenue 0, Palmdale, CA 93551 a U.S. ARCHITECTURAL
U.S. P O I e Co Inc. Phone (661) 233-2000 Fax (661) 233-2001
www-Itg.com