HomeMy WebLinkAbout06030031 Signed Conditional
ENCOMPASS NOTE PAD - 04/14/06
~OTES FOR: 06030031 BLDG 2 - PR
DATE TIME NOTE TEXT
2006-04-14 14:11:12 1. smoke alarms
One and Two F
dition. See
Signatur
TOTAL LINES OF NOTES: 6
PAGE 1
OPERATOR
cmiser
ENCOMPASS NOTEPAD - 03/07/06
NOTES FOR: 06030031 BLDG 1 - PR
DATE TIME NOTE TEXT
2006-03-07
15:20:47 }. Submit 2-co~ies of Site Plan.
~. Indicate helght of Fin. Floor from
Yin. grade.
'& Provide legible Load Data sheet.
~. Please address the ridge beam bearing
oints-both at the existlng structure
and the gable end of te new structure.
Concerns of concentrated loads on panel
a~d headers.
~. Piers shall be a min. of 24"x24"x8"
or submit Eng. calculations for reduced
~ier size.
, 6. Indicate spacing of lag bolts and
detail of existing ledger (rim joist) .
~Underfloor s~ace to be provided with
sheathing materlal on underside of deck
to protect insulating materials and
. provide protection from air leakage.
V~. Submit thermal properties (R-values)
fyr roof and wall system.
~. Floor to be provlded with R-25
insulatio or fill oistcavity with a
minimum of R-19.
10. Smoke alarms to meet Indiana One
andTwo Family Dwelling Code, 2005
Edition standards througout the
residence.
TOTAL LINES OF NOTES: 27
PAGE 1
OPERATOR
cmiser