HomeMy WebLinkAbout06030012 Pool Plans & Site Plan
'\
Gershman Brown & Rssoc Fax:317-57~-7336
F.b 28 'lfXj; 11;:28 P,01
.'
/
- 0
"J,.
@
Ii
~
t:
~
~I
i~
o
~
>
;
g
,\
~
~nlff
~zi
~ai~J
~g~li
~!~l'1t
z c"
o ~
u J
~
u
-
~
;UJ
",.. :Tp.\JC-no,~.
1f\.~\V ,r::; .~~ CON5_lI Rf.,g'j\a\\("~
~,), . LE.J.\~~~.. ,,0.1:\00 \N~V' -~ LJ:r: ,.."<\
,.O~ :\ectt?\'O~ite and \~:::~~"~E~\I\~;~\P
'O;J ':..: CO"AMl.p~ ''I ,'OW\'!':: .'
DEPl ill: ME"- f G\.J'>
~ r.>:::~.~p; >.'0,,,\,-\1'
C\ I ' V"<...> ,,~ ,1'" '
,
'2.,).0
t'
3
~
~
~
lsl
-...l
~
c:::.
-!
~
N
~
('ol
-
l'<')
'-.
---
()
,I
'"
l '"
-. ~
~
.(
'"
1. J
~
~ ~
~ I ..1
~ "
~ ,
'\l.. !~
I
~ J ~
'llI: I <:\I.
..... '.!.l.
:.
, I ~
Iv
I ~
,
\1\ I
"'I
i ~
~ '
I ,
.!;
t~! '-'
~l
, o.J
- ,
'-'\ \ 0
~ ': '0
~:~
t-+
u
~g
, >- Cl:'
>.2 eN
~<C 10M
V) a.. .9Pg
o~ -5q-
&8 ~~
~ ..r;;;-
Q) --.J t ~
1nOoE
ro 0 Z ro
::2:a..~u
>-,...,
0::0
0:: ~
W
I-
'Ie
~
1 .~
~
~
<3
f /
~
\ "" '<
;:,. 0
\.\ ---1
I' ~.
~
"
~
r-
~
\1'>
.~
, " '(
'" t
, 'J
v.
~
"
,
I I I '.
-\.?
9~( "
-<
'" '
~ 5.. ;Co .
" .~:~
....... ~:~
'" ~~ -
- ,., ~
""
~" s -'\ .0
<<-
:" ~
..r
~.O ~
..
~ t
,~
. I
)00-
, ~
..
""
"
.. ;
.... ~
""
,.. h..
. ......
'"
\;l, -:\\' ..
i"o
r
---
\
~
fL
~t .~ ./
'-
f"
r
~
t
,"
m
,
t .,'. I
. ~"... If
,'" ..l.\
, I j,.~\} ,rl..n
.. ..
...
.
,
GENERAL NOTES
1. Install a GFCI as required by the National Electric Code
and the Canadian Electrical Code.
2 All wiring should be done by a licersed electrical con-
tractor in accordance with local electrical codes and as
required by the National Electric Code or the Canadian
Electrical Code, as applicable.
3 See Table I for recommended pool lighting levels. See
Table /I, Page 4, for light niche bulb and cord specifica-
lions,
4. i A CAUTION I Risk of burns. Lights over lOOW. not rec-
ommended for spa installation.
Table I: Typical lighting Requirements
Type of Pool
Smal) Residential Pools
(less than 800 sq. h. (75 sq. m.})
large Public Pools
Diving Pools (Less. than '2 h. O.6SM) deep)
Divmg Pools (12 to 20 h. 13.65 to 6M) deep)
Competition Pools
Allowance of
Watts/Sq. Foot
of Pool Area
1/2 to l'
1 to 1-1/2
'-1/2 to 2
2 to 3
2 to )**
. One 500 Watt light at deep end of pool is recommended.
.. For competition pools:
1 Make sure thallhe start/finish ends of lanes are well lighted.
2. Never install lights in end walls at end of swimming lanes. However,
if short course racing is provided across the width of a 50 meter
course, light fixtures may be installed between lanes (under racing
lines) on a separate switch,
JUNCTION BOX
Locate Min. 4'0' (1220 mm) Behind
Pool Wall and Mln 8' (203 mm)
Above Lip of Coping
Up of Coping
ElevaUon
figure 1: Junction Box, Part #05730-0021
SPECIFICATIONS for WET NICHE
LUMINAIRES:
., The light itself is a copper housing with thermostat and
porcelain lamp base imbedded in epoxy, heat resistant
glass lens, and bulb. It is designed to operate only when
fully submerged (recommended submersion depth is from
18 to 60 inches 1.5M to 1.5M]), Except when installed in
an area of the swimming pool that is notused for swim-
ming and when the lens is adequately guarded to keep
1112"(38.1 mm)
'112"
(21fmm)
OIL
L
71 Watarproollng
Fao. RIng Compound
'"
(22~ mm)
Figure 2: Niche Dimensions
11132"
(2~mm)
DI..
lli1nt.rnal
Ground
U..d with
Non.IoI.t.lIic
Condull
Ught Cord
Water,
Level
.,
'.. .0 ',.' '.0.
.,.
.0
,'6,'0' ",
,
. .
o Q.
'..
18".60.
(457 mm.
1524mm)
l
.'. . D
'"
. 0 C> ~ - - -.
(. . . 0
.1 iJ 0. . .0
. I ".
. 1 .. . ~
~l . a'
,. .. .'
6.'
. .
8.S. Light Niche
No. 5068-0012.314"{19,05 mm)
No. 5068-0017-1"(25,4 mm)
~^
o '0
..
Underwater LIght
Approved
Ground Clamp
:..
4" Min.
(107mm)
Figure 3: Niche Installation In Gunite Pool
any person from contacting it, install the fixture in or on a
pool W$iJl with the top of the lens opening at least; 18 in.
(.5M)oelow the normal water level of the pool.
. lights and niches shall be used in fresh water'pools only
. The lens is heat resistant glass and focuses the light beam
in a 300 horizontal arc, with 150 downward deflection,
and is sealed by a molded one-piece wrap-around neo-
prene gasket. A stainless steel face ring with 10 mounting
studs fastens the lens to the housing. The studs give unl.
form pressure around the lens between the face ring and
the light housing.
. The housing includes a thermostat switch attached to a
porcelain medium base socket, two power termfn1ls, and
a ground wire connection. This assembly and the cord ter-
minals are encapsulated in epoxy ("potted") to waterprooi
all connections. Housings for 120-volt systems indlude a
"current collector" to ground the system in case o( len\
and bulb breakage.
3