Loading...
HomeMy WebLinkAbout06030033 Site Plan '-~ Scmeider This Plot Plan Prepored For. Mil Homes Lot # 71, contoining11,049 S.F.t, in Heothlll' Knoll i SectIon # 2 i Instrument # 2006-00004470 PC 4 Slide 13 Cloy Townsh". Hemlton County SEe 20. 11~._~ 2661 PARAMOUNT CIRCLE (50' R/W) Westfield, IN 46074 Prepared Date: 02/17/06 : By: KAG Community Restrictions: Side Yard = 3' min. Rear Yard = 20' min. Aggregate = 6' B.H. Zoning - 51 M/I Hames finished Floor Elevation InformatiOfl. I Pad Grade: 91B.7 per plan I Pad Grade + 0.2' : Garage FfQ918.9) Garage fIT + 0.5' : Residential fIT I (919.4) Residence fIT - 9.0' : Basement fIT (910.4) Note : The garage finished floor elevation is 1.8' above the curb at the driye, per plan. GROUND CO~ CALCULA liONS: Dri.. = 1,362SF t Public Walk: 344 Sft PriYOte Walk :N/A Sft Seeding :5,617 Sft Sod = 2,318 SYt, from front of residence. The ScbnoIdeI" Corpontloo BllOt ou. A1"lmue m.t.ricl'ort-. "..Il"n.~,Indiana48218-103'7 317-1128-7100 317-82ll-7200 r.u ~ -., ~ Arclo!tacbn G19.1lB GeoIccJ Nate: This drawing is based on construction pions or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not worront the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to ony construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately. failing to do so results in the contractors assumption of 011 liability. Plat Plan Legend I][![ID Proposed Grades 000.0 Existing Grades __000.0- Contour Grade * Appro,. Lateral Location - . - Sanitary Sewer lines -11'- Storm Sewer lines - 'wi ~ Water Service lines - - - - - - - Sub-Surface Drain lines . Manh"e (Sanitary or Storm) . BeeI1ive Inlet (Storm) 11III Curb Inlet (Storm) D End Section (Storm) ..... Fire Hydrant - 000 - 000 - Flow line of swate - - Bu~ding Une (BL / BSL) - - - - - - - Easement Une VB06.OO49101 LOT * 71 ~ ~ =~= ~ Assumed Narth Scale: 1. : 30' Note: Sanitary Sewer Top of Casting Information Upstream Manh"e, TC:917.13 Downstream Manhole, TC=918.39 per record drwg. '" PARA~~I~CLE 1'\ I T :'JJ.rt - II &-8 :'JJ.rt IHI 4.0' IBM El1V=917.1 R(ll CURB ~WAlJ( AP!lCN p'1~?; ~ 85,00' s ~ ::: .... tJI1VD ;..., il/ 14.42 "'" 12.9t lIRE eM .. GMJg, 8 ~c - '" IlRI'IE CY""MS: ~ ::l .... ill 25.0' :... OllAR: c 10. 5.0 fllllU'Y 30.0' """"" F1' 1:l ,.. to ~ '" 7.0' BOXBA~ OIl' '-" SCREEN 9 PQlCH DECK! 0 ~ q .:;1( 1;;.J- ~ ql~ .'}D '\<- Nate: Sump pump(s) to be placed by bulder as needed. Nate: The basement elevation, depicted hereon, has been determined and based upon the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or soil types has been provided or stated on said pions. It is recommended that the basement finished floor eleYOtions be at least two feet (2') aba.. the normal pool oIeYOtion of any adpining bodies of water, unless 0 study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. ~ '-" 9 o q FLOOD HAZARD STATEMENT CERTlFlCA TlON ~\\I\I\I\\III1IiIiI/I/",,!. ~~'c. L /'I "oW% ~~\~ . ()/'h~ ~ .~' ...............".Vj~'0, ~~~.,.~G\S TElti-.......~ "'~:.~ No 0',,;<>'" f ( 50303 ') i % .... STATE OF .... ~ \<2.....!..vD'A\'.\!':.....~# ~ '#J ..S....U..ii\i\.~ ~ ~~!. 1\'1 ~'*'~ W""I/I/I/IIII\\\\\\\\\\' Oc-lf11 N/C RE~SION 1: ADDED ADDRESS 2-23-06 SKN z ~ '0 I '- TYPICAL SWALE SECTION Flood Hazard Statement: The accuracy of any flood hazard data shown on this plat plan is .subject to map scale uncertainty and to any ather uncertainty in location or elevation on the referenced flood insurance rate map (~RM). None of the within described land lies within that special flood halard zone -A-, os said land plots by scale on Community Map Panel , 18057C020Sf of the flood insurance rate maps (FiRM) far Ham~ton County, Indiana, Dated May 19, 1981. 1915.7 I 55.1 mill 15' R.D.E. ~ ... Co 85. OetaD of Ground/Slonn Water: Flow pattern of on indiYiduallol I \ I .. I. I[J~ I I \ I I Note: Bunder to ensure positive drainage away fram structure(s). i6.O' ~ C Co TC-912. 78 C A t.7 PIR REOOlO . . DRAWING. VAR. D.U.& .5.E,& L.M,A.E.&P.I,E,E. NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. CITY OF CARMEL / CLAY TOWNSHIP WATER / SEWER PERMIT / RECEIPT Permit #: 06030017 Date: 03/07/2006 PARCEL ID #: ZHEK71 lOT & SUBDIVISION: 71 HEATHER KNOll ADDRESS OF CONSTRUCTION: 2661 PARAMOUNT CI WESTFIELD, IN 46074 PAYMENT RECEIVED FROM: Name: Mil HOMES OF INDIANA CHECK #: 13863 EXCAVATOR INFORMATION: Name: RT. MOORE CO., INC. Ph. #: (317) 291-1052 Fax #: Email: Street Address: 6340 lAPAS TRl INDIANAPOLIS, IN 46268 Bond Expiration: PERMIT TYPE: USEWRWATR SEWERlWATER PERMIT Special Notes/Conditions: LOT 71 HEATHER KNOLL. WATER CONNECTION PERMIT. . NO NOTES' The building & Sewer Shall be pve sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials arc hereby permitted in writing. The sewer shall be installed in accordance with ASTM 2321 for pve pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be in strict compliance with pertinent City of Car me] ordinances. Back Water check valves shall be installed in accordance with City Code Section 9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter. All installations shall bc "open trench" inspccted and aporoved bv the Carmel Sewer Deoartment before any backfillimr is donc. Non- compliance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections. No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter thc pub I ic sewer. Sewer inspcctions should be rCQuested at (317) 571-2648 one to four hours in advancc. No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street must he cut. a senarate street cut nermit shall he oht<linen. APPLICANT NAME: TONJA G~ (', PAYMENT RECEIVED BY: FEES: $1,310.00