HomeMy WebLinkAbout06030053 Site Plan
~~ tbe Schneider CorporaUon
" '-=~=~6-t037
317-826-7100
Schr1eider 3t7-826-72oo rAI
I
This Plot Plan Prepared For: R.H. of Indiana
Lot # 222 , containing 12,376 S.F.:!:, in
C1a)boume
Section I 3
INSlR. I 200400080247
P.c. I 3, Slide I 533
HamDton County. Clay Twp
Sec 30. TIaN. ROJE
'13448 Penniger Drive - - (50'RjW)
Carmel, IN 46074
Prepared Dote: 03/02/06: By: AMA
Proposed Bu)'lll'(s): Rolando & T raci
Community Restrictions: Haywood
Side Yord = 5'
Rear Yard = 20'
Aggregote = 10' (B.H.)
Zoning = 51
R.H. of Indiana
Finished Floor Elevation informotion
Pod Grode = 913.3 per plan
Pod Grode + 0.7' = Gar0ge FFE (914.0)
Garage FFE + 1.5' = Residentiol FFE (915.5)
Resldentioi FFE - 9.0' = Basement FFE (906.5)
...
Note : The garage finished floor elevation
I. 3.0' above the curb at the drive, per plan.
./
../
Ground Cover Calculations:
Drive = 827 SFt
Pubiic Walk = 1,095 SFt
Private Walk = 199 SF t
Hydroseeding = 4,851 SFt
Sod = 598 SYt, from
Rear of residence.
Note: Per Carmel zoning ordinance 26.1.1 : The
residential d~trlct limits height .to twenty-five feet
(25'), however 0 dwelling may be increased in
height to thirty-five feet (35') pro.ded the side
and rear yards ore increased on additional one
foot (1') for each one foot (1') the structure
exceeds the first twenty-five feet (25') In heigh!.
C;/j
1D&IoeeriD&
s.r..,m,
Len_pe Arohiteeture
GIS.IJS
GeoIoIY
Plot Plan leqend
~ Proposed Grades
000.0 ExIsting Grades
_000.0-- Contour Grade
* Approx. Lateral Location
- . - SanItary Sewer Una
-.- Storm Sewer Unes
- 'rI - Water SeMce Lines
- - - - - - - Sub-Surface Drain lines
. Manh~. (Sanitary or Storm)
I Beehive Inl.t (Storm)
Curb Inlet (Storm)
D End Section (Storm)
.... Fire Hnant
- 000 _ 000 -flow Llne of swale
- BuDding Un. (Bl / BSl)
------- Easement line
.i'Y6 -27'( <..
Note:
This drawing is based on construction plans or record drawings,
and is not based upon 0 field survey. The Schneider Corporotlon
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; foiling to do
so results In the contractors assumption of oil liability.
Note: The basement elevoUon. depicted hereon. has been
detennlned and based. upon the pad grades and/or contours token
from the construction plans for this subdivision. Unless stated, no
Information about fluctuating water tables, soil conditions. or son
twes has been provided or stated on said plans. It is recommended
that the basement finished floor elevation. be at least two feet (2')
above the nonmol pool elevation of ony adjoining bodies of water,
unless " study of facts reveals otherwise. If during the excavation
process any ground water I. witnessed, The Schn.1der Corporation
should be notified Immed!ately. The bcsemenf e1e\'aUor. should be
raised two feet (2') above the ground water. and addItional
construction techniques should be Incorporated to alleviate future
problems.
Note: Sump pump{.) to be
placed by builder os needed.
Oetol of Ground/ Stonm
Water flaw pattem for
Indlviduollots.
Note: Sanitary Sewer
Top of Costing Information
Upstreom Manhole, TC= 913.22
Downstream Manhole, TC= 912.2t
per record drawing
Sidewalk to be placed
t' from property line,
..' from bock of curb,
per plan.
~
^ Vb06,0049824
lJ Lot # 222
=~=~;!i
b
~.. ,,-. ""t
Assumed North TYPICAL SWllLE SECTION
Scale: 1. = 30'
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sonitary sewer and water line laterols.
/
Note: Bu~der to ensure positive
drainage away from structure{s).
,"
FLOOD HAZARO STATEMENT
CERllFICA llON
"\\\\\\\111111111/1//1////1.
#"'~S L. (}, ~/~
$~~...............,.~.0}~~
~ ...;;G\5 TEJ?.i........A~
"'<:::::. "Q:-V No c..;<>~
I ( 50303 ....~ ,
:::: " : ;:::-
%, ..... STATE OF' .f ~
'\ (,(;>(1v01 A~~......~#
~ 'f'lrS'''U'''R'':;j(. ~ #'
~4!. '1 ,,~\\~~
~///Ii/{f/{fllll\\\\\\\\"~
O-:-lf-tl
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special fiood hazard
zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of
Carmel, lndiana dated February 19, 2003.
SIGNATURE :
DAlE:
SIGNATURE REPRESENTS CONnRMA TION OF RECEIPT OF PLOT PlAN BY CUSTOIIER.