Loading...
HomeMy WebLinkAboutGN010.1_Arch ResponsibilitiesandSpecsG1.1RESPONSIBILITIES ANDSPECIFICATIONSNO.I HEREBY CERTIFY THAT THIS PLAN,DIRECT SUPERVISION AND THAT I AMPRELIMINARYUNDER THE LAWS IN THE STATE OFPREPARED BY ME OR UNDER MYREVISIONBYDATEDOCUMENT DATEDRAWN BYDATEISSUED FORCHECKED BYSHEETTITLERMMREPORT, SPECIFICATION WASPROJECT:LM PROJECT NO.SHEETS COVERED BY THIS SEAL:EXP. DATEREG.NO.A DULY REGISTERED ARCHITECTOWNER:#551%+#6'5.6&CONCEPT BY:8#..';8+'941#&'&'024#+4+'/+00'516#(#:ÄÄ2*10'ÄÄ%. /#551%+#6'5.6&#..4+)*654'5'48'&FINALPERMITSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 55404SN STORE #TBD03/17/22CLAY TERRACESUITE #10014511 CLAY TERRACE BLVD.CARMEL, IN 460321 FEBRUARY 2022DEKSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 554042204.1171INDIANAARCHITECTURALARI-950001331 DEC 23SCHEDULE OF RESPONSIBILITIES BY SPECIFICATION SECTION MASTER FORMAT DIVISION/SECTION MASTER FORMAT DIVISION/SECTION RESPONSIBILITY CODE FURNISH INSTALL FURNISH INSTALL SN VENDORSNGCSN VENDORSNGCEXISTINGLLGCEXISTINGLLGCSN VENDORSNGCSN VENDORSNGCEXISTINGLLGCEXISTINGLLGCEX - EXISTING TO REMAIN LLGC - LANDLORD GENERAL CONTRACTOR SN - SLEEP NUMBER (VENDOR) SNGC - TENANT GENERAL CONTRACTOR 010000 GENERAL REQUIREMENTS 090000 FINISHES (CONTINUED) 014100 REGULATORY REQUIREMENTS .1 BUILDING PLAN CHECK FEE .4 SIGN PERMIT FEES .3 SIGN PLAN CHECK FEE .5 OTHER FEES 014523 TESTING AND INSPECTING SERVICES TEMPORARY ELECTRICITY015113 015123 015133 CLEANING AND WASTE MANAGEMENT017400 020000 EXISTING CONDITIONS 024119 SELECTIVE DEMOLITION 030000 CONCRETE 033000 CONCRETE 031500 CONCRETE ACCESSORIES 035319 CONCRETE OVERLAYMENT 038000 CONCRETE CUTTING AND BORING 040000 MASONRY 050000 METALS 051200 BUILDING STRUCTURAL STEEL 054000 COLD FORMED METAL FRAMING 060000 WOOD, PLASTICS & COMPOSITES 061053 MISCELLANEOUS ROUGH CARPENTRY 061636 WOOD PANEL PRODUCT SHEATHING 064619 WOOD BASE AND SHOE MOLDINGS 070000 THERMAL & MOISTURE PROTECTION 071100 DAMPPROOFING 079200 JOINT SEALANTS 072400 EXTERIOR INSULATION FINISH SYSTEM 080000 OPENINGS 081100 METAL DOORS AND FRAMES 081400 WOOD DOORS 083100 ACCESS DOORS AND PANELS 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 088500 GLAZING ACCESSORIES SOLAR CONTROL FILMS 088123 EXTERIOR GLASS GLAZING 090000 FINISHES 092116 GYPSUM BOARD ASSEMBLIES 092116 092216 NON-STRUCTURAL METAL FRAMING 092216 092213 METAL FURRING 052116 LONGSPAN STEEL JOIST FRAMING 092226 SUSPENSION SYSTEMS 092400 CEMENT PLASTERING 092920 SUPPORTS FOR GYPSUM BOARD 093000 TILING 095123 ACOUSTICAL TILE CEILINGS 068316 FIBERGLASS REINFORCED PANELING 087100 DOOR HARDWARE 088713-B GLAZING SURFACE FILMS 088733 DECORATIVE FILMS .2 BUILDING PERMIT FEES TEMPORARY TELECOMMUNICATIONS 015600 032000 CONCRETE REINFORCING 088713-A GYPSUM BOARD ASSEMBLIES NON-STRUCTURAL METAL FRAMING AS REQUIRED BY LOCAL BUILDING DEPARTMENT. ALL OTHERS AS REQUIRED BY LOCAL BUILDING AND FIRE DEPARTMENTS. PROVIDED BY AND INSTALLED BY GC AS REQUIRED. AS REQUIRED TENANT CONTRACTOR TO PROVIDE JOB SITE PHONE FOR USE BY G.C. AND TENANT. AS REQUIRED BY LANDLORD AND TENANT, GC TO PROVIDE AND INSTALL GRAPHICS ON BARRICADE. DAILY AND FINAL AT JOB COMPLETION, DUST FREE. INFILL CONCRETE SLAB TO MATCH EXISTING (VIF): 4" CONCRETE SLAB 3000 PSI MIN W/ 6"X6" 10-10 WWM OVER COMPACTED 4" GRANULAR FILL W/ VAPOR BARRIER. COORDINATED. W/ LL REQUIREMENTS. EXPANSION JOINT MATERIALS FLOOR PATCH AS REQUIRED, ALL FLOORS ARE TO BE MADE SMOOTH AND LEVEL. CORE DRILL OR TRENCH AND PATCH EXISTING SLAB AS REQUIRED FOR COMPLETION OF WORK. EXISTING TO REMAIN. PROVIDE INCIDENTAL FRAMING INCLUDING BUT NOT LIMITED TO ROOF PENETRATION FRAMING, REINFORCING ANGLES AT RTU, DUCTS, VENTS, ETC. AS REQUIRED TO PERFORM WORK AS INDICATED IN THESE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL PLANS. WOOD BLOCKING: FIRE RETARDANT TREATED, WHERE REQUIRED. PLYWOOD: FIRE RETARDANT TREATED, WHERE REQUIRED. WOOD BASE: SUPPLIED IN SHAPES AND PROFILES AS SHOWN. PROVIDE RUBBERIZED ASPHALT SHEET OR LIQUID APPLIED WATERPROOF MEMBRANE AND BASE INSTALLED IN ACCORDANCE WITH LANDLORD REQUIREMENTS. CAULKING AS REQUIRED AT WEATHER EXPOSED AREAS AND TOILET ROOM. SEE DOOR SCHEDULE. PROVIDE CONCEALED ACCESS PANELS IN GYP BD CLG AND WALLS AS SHOWN OR AS REQD BY CODE. GLAZING SYSTEM AS DETAILED IN PLANS WITH CUSTOM FINISH. INTERIOR PARTITIONS: 20 GA. METAL STUDS AT 16" O.C. 5/8" TYPE 'X' GYP. BD. LEVEL 5 FINISH 20 GA. METAL STUDS AT 16" O.C. (MAX) AS REQUIRED. 16 GA. METAL JOISTS AS SHOWN / REQUIRED. CEILING/SOFFIT FRAMING: 20 GA. METAL FRAMING MEMBERS AT 16" O.C. (MAX) AT1 AND AT2 AS INDICATED. FRP AS INDICATED. SEE DOOR SCHEDULE. TEMPERED GLASS PER PLANS. SOLAR GARD WHITE OPAQUE SOLAR CONTROL FILM OR EQUAL, SELF-ADHERING AND CONTAINING ABSORBERS/INHIBITORS TO REDUCE ULTRA VIOLET RAYS AND SOLAR HEAT GAIN. INSTALL ON INTERIOR SIDE OF GLASS AS INDICATED ON PLANS (GLASS AREAS WHICH ARE NOT TO REMAIN VISIBLE TO INSIDE FROM EXTERIOR) AND PER MANUFACTURER'S INSTRUCTIONS. AS REQUIRED BY LOCAL BUILDING DEPARTMENT. AS REQUIRED BY LOCAL BUILDING DEPARTMENT. AS REQUIRED BY LOCAL BUILDING DEPARTMENT. AS REQUIRED BY LOCAL BUILDING DEPARTMENT. PER PLANS AND DOOR SCHEDULE. DEMISING WALLS: 20 GA. METAL STUDS AT 16" O.C., SOUNDPROOF INSULATION, 5/8" TYPE X' GYPSUM BOARD; LEVEL 5 FINISH STOREFRONT FRAMING 3M PRESTIGE SERIES PR70 CLEAR WINDOW SOLAR CONTROL FILM (NO SUBSTITUTIONS). INSTALL ON INTERIOR SIDE OF ALL GLASS SURFACES UNLESS NOTED OTHERWISE ON PLANS (GLASS AREAS WHICH ARE TO REMAIN VISIBLE TO INSIDE FROM EXTERIOR, E.G. SALES AREAS) AND PER MANUFACTURER'S INSTRUCTIONS. 096513 RESILIENT BASE AND ACCESSORIES 096800 CARPET 099723 CONCRETE AND MASONRY COATINGS 099123 EXTERIOR PAINTING 100000 SPECIALTIES 101419 DIMENSIONAL LETTER SIGNAGE 101423 PANEL SIGNAGE 104416.13 PORTABLE FIRE EXTINGUISHERS 105617 WALL-MOUNTED STANDARDS & SHELVING 107313 AWNINGS 102820 DIAPER CHANGING STATIONS 110000 EQUIPMENT 112113 CASH REGISTERS AND CHECKING EQUIP. 112000 COMMERCIAL EQUIPMENT 120000 FURNISHINGS 130000 SPECIAL CONSTRUCTION 140000 CONVEYING EQUIPMENT 210000 FIRE SUPPRESSION 220000 PLUMBING 221000 PLUMBING PIPING 223333 LIGHT COMM. ELECTRIC WATER HEATERS 224200 COMMERCIAL PLUMBING FIXTURES 230000 HVAC 233000 HVAC AIR DISTRIBUTION 233400 HVAC FANS 230900 INSTRUMENTATION & CONTROL FOR HVAC 233313 DAMPERS 211300 FIRE-SUPPRESSION SPRINKLER SYSTEMS 099123 INTERIOR PAINTING 102813 TOILET ACCESSORIES 113000 RESIDENTIAL EQUIPMENT 260000 ELECTRICAL 261000 MED-VOLTAGE ELECTRICAL DISTRIBUTION 272000 DATA COMMUNICATIONS 273000 VOICE COMMUNICATIONS 271000 STRUCTURED CABLING 274000 AUDIO-VISUAL COMMUNICATIONS 270000 284600 FIRE DETECTION AND ALARM 237400 PACKAGED OUTDOOR HVAC EQUIPMENT 096519 RESILIANT TILE FLOORING 097200 WALL COVERINGS 274000 AUDIO-VISUAL COMMUNICATIONS 274000 AUDIO-VISUAL COMMUNICATIONS 274000 AUDIO-VISUAL COMMUNICATIONS 265100 INTERIOR LIGHTING 265119 INTERIOR LIGHTING 262700 LOW-VOLTAGE ELECTRICAL DISTRIBUTION EXTERIOR IMPROVEMENTS EARTHWORK ELECTRONIC SAFETY AND SECURITY UTILITIES COMMUNICATIONS 330000 320000 310000 280000 CARPET SUPPLIED BY VENDOR; INSTALLED BY GC. SEAL EXPOSED CONCRETE WITH (2) COATS CS1. PRIME ENTIRE SPACE AND PAINT (2) FINISH COATS. STOREFRONT SIGN: GC TO COORDINATE INSTALLATION WITH SIGN MANUFACTURER. INTERIOR VINYL SIGNAGE AND GRAPHIC PANELS. GC TO COORD SIGN INSTALLATION WITH PROJECT MANAGER. CLASS A-B-C DRY CHEMICAL 10-POUND EXTINGUISHER AS DESIGNATED BY THE TENANT AND FIRE MARSHAL; VERIFY LOCATION AND QUANTITY WITH FIRE MARSHAL. STANDARDS, LOW PRESSURE LAMINATE SHELVES (12"DEEP, 5 TIERS), KNIFE BRACKETS. AS REQUIRED; SEE TOILET ROOM NOTES AND DETAILS. BED PUMP UNITS VB1 AS INDICATED. VINYL REDUCER STRIPS BY CARPET INSTALLER. AS REQUIRED; SEE TOILET ROOM NOTES AND DETAILS. POS TERMINAL CONTACT LOCAL TELEPHONE COMPANY. GC TO PROVIDE AND INSTALL CONDUIT AS INDICATED ON ELECTRICAL SHEETS METERING, PANELS AND POWER DISTRIBUTION ATLAS SOUND FAP40T WHITE 4" SPEAKER. WIRE: IW-2-22GA COPPER TWISTED WIRE CABLE. 10' COILED AND LABELED AT MUZAK PLAYER. CONTACT: newstorerequests@sleepnumber.com COORDINATE DEVICES WITH BUILDING SYSTEMS VINYL TILE WITH WATERPROOF MEMBRANE AS REQUIRED; (SN GC PROVIDES FC3, VENDOR PROVIDES REMAINDER) GC TO VERIFY REQUIREMENTS W/ LL. WC1 RIDE ROOM SPEAKER: HOLOSONICS AS-168i RIDE ROOM SPEAKER MOUNT: VANTAGE POINT SWING MOUNT MNTV-1 AUDIO VISUAL MOUNTING HARDWARE LED LIGHT PANELS IN IFIT/RIDE ROOM RIDE ROOM - SWITCHES: LEGRAND LVSW-103-B, PLATES: LEGRAND RWP26B, CABLE: 20' BELDEN 5504UE PER MECHANICAL SHEETS PER MECHANICAL SHEETS PER MECHANICAL SHEETS PER MECHANICAL SHEETS PER MECHANICAL SHEETS MODIFY EXISTING SYSTEM. SPRINKLER HEADS SHALL BE CONCEALED HEADS. GC SHALL VERIFY FIRE ALARM REQUIREMENTS 125383 CUSTOM RETAIL FURNITURE HEADBOARDS, POS COUNTERS, ACCESSORY UNITS AND FIXTURES TO BE ASSEMBLED BY GC AND INSTALLED PER AWI PREMIUM GRADE STANDARDS. 122400 WINDOW SHADES AUTOMATED SOLAR SHADES- PHIFER SHEERWEAVE 2390, 4" BOTTOM MOTORIZED, FASCIA COLOR: BLACK, SHADE COLOR: V21 CHARCOAL. COORDINATE INSTALLATION W/GC. 122500 WINDOW TREATMENT OPERATING HDWR AUTOMATED SOLAR SHADES OPERATING HARDWARE. COORDINATE INSTALLATION W/GC. 05/25/22