Loading...
HomeMy WebLinkAboutA010.0_ArchitecturalSCALE: 1/4" = 1'-0" CODE COMPLIANCE PLAN VESTIBULE REQUIREMENT CALCULATION: NET SALES AREA = 2,959 SF. NO VESTIBULE REQUIRED FOR SPACES UNDER 3,000 SF.NORTHBA BB BC BD B4 B3 B2 B-EM B-EM B-EM H H H B-EM B-EM B-EM B-EM B-EM B-EM B-EM B-EM B-EM MAXIMUM ACTUAL TRAVEL DISTANCE 65'-0" TO AN EXIT MAX. ACTUAL COMMON PATH FOR 'M' OCCUPANCIES 15'-3"<75'-0" MAXIMUM ACTUAL TRAVEL DISTANCE 66'-7" TO AN EXIT MAX. ACTUAL COMMON PATH FOR 'S1' OCCUPANCIES 42'-0"<100'-0" 100 ENTRY GC TO PROVIDE & INSTALL 2A:10B:C DRY CHEMICAL FIRE EXTINGUISHER LOCATED PER FIRE MARSHAL PROVIDE TACTILE EXIT SIGNAGE - SEE DETAIL B1/A1.0 36" LONG x 29" HIGH ACCESSIBLE SERVICE COUNTER 101 SALES AREA 2987 SF 105 A TOILET 72 SF 102 HALLWAY 244 SF 104 B STORAGE 145 SF 106 B TOILET 72 SF 103 A STORAGE 248 SF 32" HIGH ACC SERVICE COUNTER W/ 29" KNEE CLEARANCE ON PUBLIC SIDE 48" MIN 30" MIN 3'-0"30" MIN48" MIN PROVIDE TACTILE EXIT SIGNAGE - SEE DETAIL B1/A1.0 GC TO PROVIDE & INSTALL 2A:10B:C DRY CHEMICAL FIRE EXTINGUISHER LOCATED PER FIRE MARSHAL REQUIRED MINIMUM SEPARATION BETWEEN EXITS CALCULATION: DIAGONAL DISTANCE: 85-8 1/8" DISTANCE BETWEEN EXITS: 99'-8 3/8" 1/3 OF 85'-8 1/8"= 28'-7" 99'-8 3/8" > 28'-7" MEETS CODE 99'-8 3 / 8" 85'- 8 1/ 8 " 30" MIN 30" MIN 36" MIN36" MIN3'-3"4'-0" 4'-0"4'-5 5/8"3'-3" 4'-6" 3'-3"5'-0"6'-4 7 / 8 "6'-9 1/4"6'-6 3/4" 3'-0 1/8"C3 A1.1 NO.I HEREBY CERTIFY THAT THIS PLAN,DIRECT SUPERVISION AND THAT I AMPRELIMINARYUNDER THE LAWS IN THE STATE OFPREPARED BY ME OR UNDER MYREVISIONBYDATEDOCUMENT DATEDRAWN BYDATEISSUED FORCHECKED BYSHEETTITLERMMREPORT, SPECIFICATION WASPROJECT:LM PROJECT NO.SHEETS COVERED BY THIS SEAL:EXP. DATEREG.NO.A DULY REGISTERED ARCHITECTOWNER:#551%+#6'5.6&CONCEPT BY:8#..';8+'941#&'&'024#+4+'/+00'516#(#:ÄÄ2*10'ÄÄ%. /#551%+#6'5.6&#..4+)*654'5'48'&FINALPERMITSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 55404SN STORE #TBD03/17/22CLAY TERRACESUITE #10014511 CLAY TERRACE BLVD.CARMEL, IN 460321 FEBRUARY 2022DEKSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 554042204.1171INDIANAARCHITECTURALARI-950001331 DEC 23A1.0CODE COMPLIANCEPLAN & DETAILSA1 B1 EXIT TACTILE EXIT SIGNS SHALL BE LOCATED AT EXIT DOORS PER IBC SECTION 1011.3. REQUIRED TEXT SHALL BE IN BOTH CHARACTERS AND BRAILLE, MEETING REQUIREMENTS OF ICC/ANSI A117.1 SECTIONS 703.3 & 703.4. SIGNS SHALL BE MOUNTED BETWEEN 48" & 60" AFF PER ICC/ANSI A117.1 SECTION 703.3.10 AND ON THE LATCH SIDE OF THE DOOR WHERE POSSIBLE OR PER ICC/ANSI A117.1 SECTION 703.3.11.48"-60"3/8" MINEXIT GRADE 2 BRAILLE 5/8" TO 2" HIGH CHARACTERS, RAISED 1/32" MIN CONTRASTING, NON-GLARE FINISH ON BACKGROUND AND CHARACTERS. NOT TO SCALE TACTILE EXIT SIGN 05/25/22