HomeMy WebLinkAboutA020.1_ArchitecturalA2.1ARCHITECTURAL DETAILSA1 A2 A4 B3 C1 C2 C3 D2 D3 NO.I HEREBY CERTIFY THAT THIS PLAN,DIRECT SUPERVISION AND THAT I AMPRELIMINARYUNDER THE LAWS IN THE STATE OFPREPARED BY ME OR UNDER MYREVISIONBYDATEDOCUMENT DATEDRAWN BYDATEISSUED FORCHECKED BYSHEETTITLERMMREPORT, SPECIFICATION WASPROJECT:LM PROJECT NO.SHEETS COVERED BY THIS SEAL:EXP. DATEREG.NO.A DULY REGISTERED ARCHITECTOWNER:#551%+#6'5.6&CONCEPT BY:8#..';8+'941#&'&'024#+4+'/+00'516#(#:ÄÄ2*10'ÄÄ%. /#551%+#6'5.6&#..4+)*654'5'48'&FINALPERMITSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 55404SN STORE #TBD03/17/22CLAY TERRACESUITE #10014511 CLAY TERRACE BLVD.CARMEL, IN 460321 FEBRUARY 2022DEKSLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 554042204.1171INDIANAARCHITECTURALARI-950001331 DEC 23LATERAL BRACING PER ASCE 13.5.8: 20GA 3 5/8" MTL STUDS AT 48"OC IN ALT DIRECTIONS SECURED TO STRUCTURE ABOVE (3) #10x1" SELF-TAPPING STEEL SCREWS EA CONNECTION ƒ0$;10'-0" MAXSCALE: 1-1/2"=1'-0" PARTITION WALL SECTION GYP BD AS SPECIFIED PER WALL SCHEDULE, JOINTS ORIENTED AND STAGGERED VERTICALLY, OPPOSING SIDES OF ASSEMBLY TO BE STAGGERED. 1" TYPE S SELF-TAPPING STEEL SCREWS 8"OC ALONG EDGE OF GYP BD, 12"OC WITHIN FIELD OF GYP BD. CONTINUOUS BOTTOM TRACK TO MATCH STUD SIZE & GAUGE 10" MIN‘(;3$16,21$1&+25# 32"OC, EMBEDDED 2" MIN. HILTI KWIK BOLT 3 (ICC ESR-2302) OR EQ ATTACH EA STUD TO TRACK W/ (1) #10x1" SELF-TAPPING STEEL SCREW EA SIDE EXISTING CONCRETE SLAB MTL STUDS COMPLYING W/ ICC ER-3064. SIZE & SPACE PER WALL SCHEDULE. CEILING PER RCP CONTINUOUS TOP TRACK TO MATCH STUD SIZE & GAUGE NOTE: THRU-WALL PENETRATIONS SHALL COMPLY WITH UL SYSTEM NUMBER W-L 5001 T RATING 1 HR 1-HR WALL ASSEMBLY PER WALL SCHEDULE 1/4" MIN, 3/8" MAX AT NOMINAL 1" THK PIPE COVERING; 1/2" MIN, 3/4" MAX AT NOM 2" THK PIPE COVERING 1/4" MIN CONT BEAD OF 3M CO FIRE BARRIER CP-25WB+ CAULK APPLIED TO WRAP STRIP/WALL INTERFACE AND EXPOSED EDGE OF WRAP STRIP UL APPROVED 1" THK HOLLOW CYLINDRICAL FIBER MIN 3.5PCF PIPE COVERING WITH A FLAME SPREAD INDEX 25 OR LESS AND SMOKE DEV INDEX 50 OR LESS NOM 1/4" THK 3M CO TYPE FS-195+ INTUMESCENT ELASTOMERIC MATERIAL FACED ONE SIDE ALUM FOIL IN 2" WIDE STRIPS, FOIL OUT, TIGHTLY WRAP AROUND PIPE WITH SEAM BUTTED. WRAP LAYER AND SECURELY BOUND WITH STEEL WIRE OR ALUM FOIL TAPE AND SLIDE INTO ANNULAR SPACE, 3/4" OF THE WRAP TO PROTRUDE BEYOND WALL SURFACE. FIRESTOP REQ'D WHERE COMBINED BOX AREA EXCEEDS 100 SQ IN PER 100 SQ FT WALL AREA AND WHERE OUTLET BOXES ON OPPOSITE SIDES OF WALL ARE SEPARATED BY LESS THAN 24". NO BACK TO BACK OUTLET BOXES. MIN 1/8" HILTI CP617/CP617L FIRESTOP PUTTY PAD OR APPROVED EQ. INSTALL IN ACCORDANCE WITH UL REQUIREMENTS FOR WALL OPENING PROTECTIVE MATERIALS (CLIV) 1-HR WALL ASSEMBLY PER WALL SCHEDULE UL-LISTED METALLIC OUTLET BOX AND EMT CONDUIT (4"x4" MAX) NOT TO SCALE 1-HR STUD WALL PENETRATIONS EXISTING DECK VERIFY EXISTING STRUCTURE - METAL WEB TRUSS SHOWN. ATTACH TO TOP CHORD ONLY UNISTRUT P2785 BEAM CLAMP AT EA END OR APPROVED EQ 1 5/8" SQ 12GA H3 UNISTRUT AT 48"OC OR AS REQUIRED UNISTRUT TO TRUSS ATTACHMENT NOTE: -ALL ATTACHMENT METHODS SHALL BE FIELD VERIFIED. -ALL EQUIVALENT PRODUCTS SHALL BE APPROVED BY THE ARCH PRIOR TO ORDER. EXISTING DECK VERIFY EXISTING STRUCTURE - METAL WEB TRUSS SHOWN. ATTACH TO TOP CHORD ONLY UNISTRUT P2785 BEAM CLAMP AT EA END OR APPROVED EQ 1 5/8" SQ 12GA H3 UNISTRUT AT 48"OC OR AS REQUIRED 1 5/8" SQ 12GA H3 UNISTRUT AT 48"OC MTL STUD FRAMING PER WALL SCHEDULE 1/4" BOLT WITH 1 1/2" FENDER WASHERS AND LOCK NUT; THRU-BOLT TRACK TO UNISTRUT AT 48"OC MAX SCALE: 1-1/2"=1'-0" ATTACHMENT TO STRUCTURE UNISTRUT TO TRUSS ATTACHMENT TRACK TO UNISTRUT ATTACHMENT FLOORING AS SPECIFIED - CARPET SHOWN GROUT SURROUNDING CAVITY AROUND BOX RECESSED FLOOR BOX AND COVER AS SPECIFIED ON ELECTRICAL SHEETS SCALE: 6" = 1'-0" RECESSED FLOOR BOX DETAIL ALUMINUM FINISH COVER PLATE 664-CST-SW-ALM FLUSH W/ FLOOR FINISH 1'-9 3/4" 8"5'-2"1'-9 3/4"ORANGE DEDICATED RECEPTACLE LEFT SIDE, NON-DEDICATED RECEPTACLE RIGHT SIDE INSTALL J-BOX FOR LINE 3 & DSL LINE 3/4" CDX PLYWOOD PRESSURE MAPPING CABINET 4" 6"4'-8"SCALE: 1/2" = 1'-0" POWER & SIGNAL EQUIPMENT PANEL HOLLOW METAL FRAME, FIN PER SCHEDULE DOOR, HINGE & FINISH PER SCHEDULE DOUBLED 3-5/8" MTL STUDS TYP @ DOOR R.O. 5/8" GYP BD TYP. SEE WALL SCHEDULE & ARCH PLAN FOR LOCATION SCALE: 3" = 1'-0" TYPICAL DOOR DETAIL SCALE: 3"=1'-0" TYP COLUMN ENCLOSURE- W FLANGE 5/8" TYPE 'X' GYP BD TO 6" MIN. ABOVE CEILING HT. 1 5/8" MTL FURRING STUDS TO CEILING EXISTING COLUMN, VERIFY LOCATION & SIZE IN FIELD *NOTE* NO VISIBLE SEAMS 5/8" TYPE 'X' GYP BD TO 6" MIN. ABOVE CEILING HT. 3" = 1/-0" TYPICAL TUBE STEEL COLUMN ENCLOSURE 1 5/8" MTL FURRING STUDS TO 6" MIN. ABOVE CEILING HT. EXISTING COLUMN, VERIFY LOCATION & SIZE IN FIELD *NOTE* NO VISIBLE SEAMS GYP BD AND STUD WALL PER PLAN NOTE: IN EXISTING WALL CONDITION, REMOVE REQUIRED AMOUNT OF GYP BD TO EXECUTE DETAIL. PROVIDE ADDITIONAL BLOCKING TO PATCH WALL FOR SMOOTH, FLAT SURFACE TO ACCEPT NEW FINISH. MAINTAIN FIRE RATING WHERE APPLICABLE. SECTION 2X6 BLOCKING SCALE: 3"=1'-0" BED LAB BLOCKING DETAIL ELEVATION BLOCKING OPTIONS 2X6 OR 3 4"X6 (PLYWD) FRT BLOCKING BETWEEN STUDS BEHIND GYP BD STUD TO STUD 3/4"X6" FRT PLYWOOD ONE END DADO INTO STUD FLANGE. 2X6 FRT BLOCKING, ONE END DADO INTO STUD FLANGE, OTHER END SCREWED THROUGH STUD FACE INTO END OF BLOCKING 2- #10 2" EMBEDED AT NON-DADO END OF FRT PLYWD BLOCKING. SECTION PLYWOOD BLOCKING CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS FOR LOCATION (THREE HORIZ RUNS; 27"AFF, 67"AFF, 108") PLAN BLOCKING BOTH OPTIONS FRT BLOCKING ONE END DADO INTO STUD FLANGE, SEE PLAN VIEW BELOW FRT BLOCKING ONE END ANCORED WITH SCREWS INTO BLOCKING THROUGH STUD FACE LINE OF 34" PLYWD BLOCKING OPTION DADO FRT BLOCKING, ONE END DADO INTO STUD FLANGE, OTHER END SCREWED THROUGH STUD FACE INTO END OF BLOCKING NON- DADO END FRT BLOCKING 2-#10 2" EMBEDED SCREW INTO BLOCKING END THROUGH STUD FACE CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS FOR LOCATION (THREE HORIZ RUNS; 27"AFF, 67"AFF, 108") CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS FOR LOCATION (THREE HORIZ RUNS; 27"AFF, 67"AFF, 108") 05/25/22