HomeMy WebLinkAbout06030087 Site Plan
, II
_Clna SLJ~~yc>rs
11 Industrial Drive, Carmel, IN 46032
317.844.3333 F 317.844.3383
www.seagroupllc.com
: PLOT PLAN WAS
'ARED BASED ON
HMATION TAKEN FROM
JRD PLATS. SUBDIVISION
;S, RECORD DRAWINGS
PLANS PROVIDED BY
~T. IT IS THE
'ONSIBILlTY OF THE
TRACTOR TO VERIFY SITE
)ITlONS PRIOR TO
5TRUCTION AND NOTIFY
SEA GROUP LLC and
IWlCK OF ANY
'lEPANCIES.
,TION OF UTILITY
RALS ON PLOT PLAN
GENERAL LOCATIONS
PLAN AND SHOULD BE
'lED IN THE FIELD.
IER TO ENSURE POSITlVE
AWAY FROM
CTURE.
TO BE PLACED BY
ER AS NEEDED.
BUILDER IS TO
: SIDEYARD SWALE TO
:S SHOWl< ON THIS
IF BUILDER IS
.E TO ACHIEVE
VE,DRAINAGE AWAY
PROPOSED
:TURE, THE ENGINEER
. BE CONTACITD.
:R IS NOT TO DEVlA IT
GRADES SHOWl< ON
'LAN WITHOUT THE
:NT OF BOTH THE
:ER AND BRENWlCK.
THE FINISHED
ELEVATIONS AND
:RADES DEPICITD ON
'LOT PLAN IS OPEN
EVlEW BY BRENWlCK
JPMENT. THE BUILDER
mONED THAT SAID
~ATION IS.SUBJECT ~,
ANGE.
nON OF UTILITIES ON
PLAN ARE GENERAL
lONS PER PLAN AND
.0 BE VERIFIED IN THE
ILAR BACKFILL
STED UNDER
YAY AT SANITARY
LATERAL TRENCH,
LINE TRENCH AND
THER EXCAVAITD
. (IF SITUATION
S)
(SECONDARY AREAS
:TCLA Y) MAX. HEIGHT:
I LOTS 100' AND
'l (TO EVE LINE) 30'
5S THAN 100' MAX.
~GE: 50%
(PRIMARY AREAS -
AY) MAX. HEIGHT:
LD-UP LINE: 2
; MAX. COVERAGE:
?AD ELEVATION
IS PER PLANS AND
THE AS-BUILT
ON.
THE INFORMATION
E ELEVATION
:NCE BETWEEN THE
Y FINISHED FLOOR
ON TO THE TOP OF
NT WALL AND TO
SEMENT FINISHED
WAS PRO\1DED BY
ILDER.
Grou
100.01 PROPOSED GRADE PER PLAN
- GROUND WATER FLOW
----- SANITARY SEWER LINE
-~-~- STORM SEWER LINE
-WlIt-Wllt- WATER UNE
----------------- EASEMENT LINE
-- - - - - BUILDING SETBACK LINE
AREA OF WAITR TAP TO BE
BACKFILLED WITH GRANULAR
MA ITRIAL TO WITHIN 10. OF
TOP OF CURB.
DENOTES LOCATION PER
CONSTRUCTION PLAN
DRAWINGS. CONFIRM BEFORE
CONSTRUCTION OF 6"
SANITARY LATERAL AND
WATER SERVICE LINE.
NOIT: CONCREIT APRON TO
MATCH EXISTING ALLEY
EDGE OF PAVEMENT
ELEVATION
ALL MUD IN STREETS FROM
TRUCKS LEAVING LOT TO BE
CLEANED AT THE END OF
EACH DAY.
AREA OF WATER TAP TO BE
RESTORED TO ITS' ORIGINAL
CONDITlON PRIOR TO
CONSTRUCTION.
ALL SERVICE LA ITRAL
CROSSINGS AT CURB ARE
STAMPED SS= SANITARY
SEWER SD= SUBSURFACE
DRAIN W= WAITR
LOT# 377
10,811 S. F.
MINIMUM SETBACKS
SILT FENCE AND STRAW
BAILS TO BE USED
WHERE NEEDED TO KEEP
MUD OFF OF STREETS AND
OUT OF STORM SEWERS.
Min Side 74 FeAt
Min Rear '5 Feet
Ana 166 Feet
~
oS'
/
~/
_s>"
~\\\""'I",,//l
~,''C((...~~9...'?/s..,.
*~ ,"G' ISTr;;'" 4,
S ....' c.'T~'.'
SO..... ..'~~ <()'.
~~.. N "
::Q:: ! 0
~y Description: -0): .
E * ~ LS20200083
umber 377 in Village of Westclay, Section 6502, an Addition in Hamilton County, :=. ~
"\ \" STATE OF
a, as per plat thereof recorded as Instrument Number 200100077772 found in the ""<'" .
'\ -<1,t.....'NDI...lI.~.\,
of the Recorder of Hamilton County, Indiana. :if. '[) ......... \.
~"l SUR\! ~~
1/11111111""'\
Prepared For: ~~
PLOT PLAN Woodall Construction
1"=30' I Drawn by: DJR Residence
e:
o' Feb. 16, 2006 I Revised: 1922 Broughton Street