HomeMy WebLinkAboutC600 - Storm Plan & Profile-C600SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860 CURB INLET #40548" DIA MHSTA. 1+82TC=855.2615 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=850.58 DOWN INV.=850.54 MANHOLE #404WQ STR.STA. 1+67TC=855.39115 L. F . 2 . 6 3 % 1 5 ' ' R C P 847.40 850.44 YARD INLET #40360" DIA MHSTA. 0+52TC=853.8052 L.F. 0.29% 18" R.C.P. CLASS III UP INV.=847.15 DOWN INV.=847.00END SECTION #402STA. 0+0015'' RCP SW INV.=847.40 18'' RCP NE INV.=847.15 12'' RCP NW INV.=847.65 PROPOSED GRADE N.P.=847.00 EXISTING GRADEI.E. 851.9 6" SSD I.E. 851.3 6" SSD HYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860OUTLET CONTROL #401CUSTOMSTA. 1+11TC=853.50111 L.F. 0.36% 18" R.C.P. CLASS III 846.60 847.00END SECTION #400STA. 0+00PROPOSED GRADE EXISTING GRADE HYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860 YARD INLET #40360" DIA MHSTA. 0+00TC=853.80YARD INLET #40924" x 24" BOXSTA. 4+90TC=853.60137 L.F. 0.30% 12'' RCP 849.99850.40 YARD INLET #40824" x 24" BOXSTA. 3+53TC=853.80138 L.F. 0.30% 12'' RCP 849.48849.89 YARD INLET #40748" DIA MHSTA. 2+15TC=853.80147 L.F. 0.30% 12'' RCP 848.94849.38 YARD INLET #40648" DIA MHSTA. 0+68TC=853.8068 L.F. 1.74% 12" R.C.P. CLASS III UP INV.=848.84 DOWN INV.=847.65 15'' RCP SW INV.=847.40 18'' RCP NE INV.=847.15 12'' RCP NW INV.=847.65 PROPOSED GRADEEXISTING GRADE HYDRAULIC GRADE LINE I.E. 851.3 (2) 6" SSD I.E. 851.3 6" SSD I.E. 851.3 6" SSD I.E. 851.3 6" SSDI.E. 851.1 6" SSD SE.,SW. SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860CURB INLET #43048" DIA MHSTA. 2+28TC=854.2230 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=850.26 DOWN INV.=850.17CURB INLET #429WQ STR.STA. 1+98TC=854.22130 L.F. 0.72% 12" R.C.P. C L A S S I I I 849.13 850.07YARD INLET #42848" DIA MHSTA. 0+68TC=853.8068 L.F. 3 . 0 0 % 1 2 " R.C.P. C L A S S I I I 847.00 849.03END SECTION #427STA. 0+008'' SDR-35 PVC INV=843.88 PROPOSED GRADE N.P.=847.00 EXISTING GRADE I.E. 850.9 6" SSD I.E. 850.9 6" SSDHYDRAULIC GRADE LINE OTTO LANEI.E. 850.5 6" SSD STRM 431-436 SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860INLET #43548" DIA MHSTA. 2+29TC=854.0828 L.F. 0.29% 21" R.C.P. CLASS III UP INV.=848.38 DOWN INV.=848.30CURB INLET #43448" DIA MHSTA. 2+01TC=854.3715 L.F. 0.33% 21" R.C.P. CLASS III UP INV.=848.20 DOWN INV.=848.15MANHOLE #433WQ STR.STA. 1+86TC=854.64137 L.F. 0.18% 24" R.C.P. CLASS III 847.65 847.90YARD INLET #43260" DIA MHSTA. 0+49TC=853.6049 L.F. 0.33% 30" R.C.P. CLASS III UP INV.=847.16 DOWN INV.=847.00END SECTION #431STA. 0+008'' SDR-35 PVC INV=846.22 24'' RCP S INV.=847.65 30'' RCP W INV.=847.16 30'' RCP E INV.=847.26 PROPOSED GRADE N.P.=847.00 EXISTING GRADE HYDRAULIC GRADE LINE VILLAGE CREEK DRIVE18 L.F. 0.29% 21" R.C.P. CLASS III UP INV.=848.53 DOWN INV.=848.48 I.E. 851.1 6" SSD I.E. 851.0 6" SSD I.E. 850.7 (3) 6" SSD 8" WATER18"MIN18" MINE.,W.,S. JACKSON'S GRANT ONWILLIAMS CREEK SECTION 5Inst. No. 2017-054815Plat Cab. 5, Slide 758 VAR. B.M.P.E.&R.D.E.30'30'30' DRAINAGE FLOOD ROUTE EASEMENT INST. NO. 2020-069148 30' DRAINAGE FLOOD ROUTE EASEMENT INST. NO. 2020-069148 5' SIDEWALK5' SIDEWALK5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK5' SIDEWALK5' SIDEWALK5' SIDEWALKPERGOLA W/ BENCH PERGOLA 5' SIDEWALK 5' SIDEWALK C.A.#1-2 WWWWWWWWWWWWWWWW* * ** ** * * ** * * * VAR. D.&U.E. VAR. R.D.E. & B.M.P.E. W W W W W W W W W W W W W 435o o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o o o o o o o o o o o o o o 401 430429 428 427 405 404 403 402 409 408 407 406 414 413 412 411 410 434 433 432431 439438 437 S 50' R.40' R. 52' R/W 30' B-B 52' R/W30' B-B50' R/W 30' B-B 50' R/W 30' B-B 12 19 15 11 18 17 16 13 14 8 7 10 9 C.A.#1-3 855856857857855855854855855 855854854855856 855850855846847848849851852853854850 855 855 846 847 848 849 851 852 853 854 855 855856856 855855855 855 20' D.U.&S.S.E.20' D.U.&S.S.E.25' R.D.E. 1 5 ' R .D .E .40'SPILLWAYEL.=853.5025' B.L.25' B.L.25' B .L . 25' B.L.25' B.L.25' B.L.25' B.L.25' B.L.25' B.L.10' S.S.E.20' B.M.P.&U.E.C.A.#1-2 25' R.D.E. 855 853854 855 853854 52' R/W30' B-B10' S.S.E. LAKE #1 N.P.=847.00 2 YEAR ELEV.=848.30 10 YEAR ELEV.=849.26 INTERIM 100 YEAR ELEV.=851.45 100 YEAR ELEV.=853.50 BOTTOM ELEV.=835.0025' R.D.E.25' R.D.E . 25' R. D . E . 25' R. D . E . 400 VILLAGE CREEK DRIVE (LOCAL) VILLAGE CREEK DRIVE (LOCAL)OTTO LANE(LOCAL)KEATON CIRCLE(LOCAL)OTTO LANE(LOCAL)85685685785685720' B .M .P .&U .E . 20' B.M.P.&U.E. 20' B.M.P.& U . E . 20' B.M.P.&U.E.20' B.M.P.&S.S.E.20' B.M.P.&S.S.E.20' B.M.P.&S.S.E.15' R.D.E.15' R.D.E.15' R.D.E.1 5 ' R .D .E .15' R.D.E.15' R.D.E.25' L.B.E.30' D.&U.E.15' R.D.E.15' D.&U.E.15' D.&U.E.15' R.D.E. 15' R.D.E.15' R.D.E.15' R.D.E.30' D.&U.E.25' L.B.E.VAR. T.P.E. 111 L.F. 18" R.C.P. @ 0.36%30 L.F. 12" R.C.P. @ 0.30% 130 L.F. 12" R.C.P. @ 0.72%68 L.F. 12" R. C. P. @ 3.00 % 15 L.F. 15" R.C.P. @ 0.30%115 L.F. 15" R.C.P. @ 2.63%52 L.F. 18" R.C.P. @ 0.29% 137 L.F. 12" R.C.P. @ 0.30% 138 L.F. 12" R.C.P. @ 0.30% 147 L.F. 12" R.C.P. @ 0.30% 68 L . F . 1 2 " R . C . P . @ 1 . 7 4 % 33 L.F. 18" R.C.P. @ 0.21% 15 L.F. 18" R.C.P. @ 0.30% 81 L.F. 18" R.C.P. @ 0.30%62 L.F. 18" R. C.P. @ 0.30 % 28 L.F. 21" R.C.P. @ 0.29% 15 L.F. 21" R.C.P. @ 0.33% 137 L.F. 24" R.C.P. @ 0.18% 49 L.F. 30" R.C.P. @ 0.33% 121 L.F. 30" R.C.P. @ 0.14% 30 L.F. 30" R.C.P. @ 0.20% 27 L.F. 30" R.C.P. @ 0.19% 106 L.F. 30" R.C.P. @ 0.18% 18 L.F. 21" R.C.P. @ 0.29%855856857** * EX JGV804 JGV803 JGV802 JGV801 JGV800 JGV810855854856 854855855856 5' SIDEWALK 5' SIDEWALK W W W* 24'61' R/W30' B-BW85 6 85785 5 459 EX-2 * *85610' S.S.E. VILLAGE CREEK DRIVE (LOCAL) 21 L.F. 12" R.C.P. @ 0.96% *JGV812 SCALE: 1"=50' HOR. 1"=5' VERT. 845 850 860 845 850 860 EX. INLET #EX-2EX. STRUCTURESTA. 0+00EX. TC=858.01ADJ. TC=857.4721 L.F. 0.96% 12" R.C.P. CLASS III UP INV.=853.20 DOWN INV.=853.00CURB INLET #45924" x 24" BOXSTA. 0+21TC=857.1412'' RCP W INV.=853.00 12'' RCP E INV.=852.87 I.E. 853.8 (3) 6" SSD I.E. 853.6 6" SSD NE.,SE.,SW. 60160JGV-R1 AEC BKR CARMEL, CLAY TOWNSHIPHAMILTON COUNTY, INDIANA06/16/21File Name:S:\60160JGV-R\DWG\C600 - Storm Plan & Profile.dwg - C600Modified / By:March 19, 2022 4:24:36 PM / ecarsonPlotted / By:March 20, 2022 4:48:30 PM / Erik CarsonJACKSON'S GRANT VILLAGESECTION 101/18/22CITY OF CARMEL REVIEW COMMENTSAEC03/18/22CITY OF CARMEL & TRICO REVIEW COMMENTSAECNOTES ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD PLAN D-18 ON SHEET C801A. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A. ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC. MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY THE CITY OF CARMEL. UTILITY CROSSINGS CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. GRAPHIC SCALE ( IN FEET ) 1" = 50 FT LEGEND EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE DENOTES FULL DEPTH GRANULAR BACKFILL (SEE TRENCH DETAIL 10-31 ON SHEET C802)DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.STORM SEWER PLAN & PROFILESC600