Loading...
HomeMy WebLinkAboutM002.0 - EWP LAYOUTIndianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By:Structural Drawings Prepared By:84 Lumber FranklinKevin BeherPyatt BuildersTG44Rev.ByDateCommentsDrawn By:JRChecked By:Date:4/29/2022Berkeley 2200668 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing 11 7/8" TJI Joists 24" O.C. Spacing 11 7/8" TJI Joists 24" O.C. Spacing LEVEL NOTES  Current Date: 5/4/2022  File Name: TG44-2200668.jvl  Level Name: Second Floor System  Building Code - Design Methodology: IBC 2006  Members with Design Overridden:  FLOOR  Floor Container: FC6  Use/Occupancy: ResidentialLivingAreas  Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Operator Added Additional Loads Floor Maximum Allowed Deflection  L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Directly Applied Ceiling: Gypsum 1/2"      Decking Attachment: Glue and Nail      Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition: No      Strapping at max 8' o.c.: None      Blocking at max 8' o.c.: No      Poured Flooring: No Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H201 46 User IUS3.56/11.88 User Defined --Not Required No Not Required Products PlotID Length Product Plies Net Qty FJ201 28' 0" 11 7/8" TJI 560 joist 1 1 FJ202 26' 0" 11 7/8" TJI 560 joist 1 9 FJ203 18' 0" 11 7/8" TJI 560 joist 1 10 FJ204 14' 0" 11 7/8" TJI 560 joist 1 6 FJ205 12' 0" 11 7/8" TJI 560 joist 1 5 FJ206 10' 0" 11 7/8" TJI 560 joist 1 3 FJ207 6' 0" 11 7/8" TJI 560 joist 1 9 FJ208 4' 0" 11 7/8" TJI 560 joist 1 6 BM201 24' 0" 1 3/4" x 24" 2.0E Microllam LVL 2 2 BM202 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 3 BM203 14' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2 BM204 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM205 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM206 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 560 joist 1 25 B1 B4 B1 A3 A3 A3 A3 H2 H2 H2 H2 B1 H2 A3 E1 E1 A3 BM203BM202BBO14BBO13 BM201BM204 BM205 VO1 VO2 VO3 VO4 FJ203 FJ203 FJ203 FJ203 FJ203 FJ205 FJ203 FJ205 FJ203 FJ205 FJ203 FJ205 FJ203 FJ201 FJ206 FJ207 FJ206 FJ207 FJ202 FJ202 FJ204 FJ202 FJ202 FJ202 FJ202 FJ202 FJ202 FJ202 FJ204 FJ204 FJ204 Ca201 Ca201 Ca201Ca201Ca201Ca201Ca201 Ca201Bk201 FJ204 FJ204 1' 0" 2' 0" FJ207FJ207FJ2061' 0" 2' 0" 1' 0" FJ203 1' 0" 2' 0" 1' 0" 2' 0" Bk201FJ207FJ207FJ207FJ207FJ2072' 0" Bk201 10' 0 1/2" 7' 10"3' 0" Bk2015' 0" 1' 2 1/16"1' 5 1/2"1' 0 1/8"1' 7 3/4"Bk201BM206 Ca201FJ2051' 4"FJ208FJ208FJ208FJ208Ca201FJ208FJ208Ca2011' 0" Bk201Ca201 1' 1 9/16"10' 1 3/4"5' 2 1/8" H201 H201 H201 H201 H201 H201H201H201 H201 H201 H201 H201H201 H201 H201 H201H201 H201 H201 H201H201H201H201H201H201 H201 H201 H201 H201 H201 H201 H201H201H201 H201H201H201H201 H201H201H201H201H201 H201 H201H201An additional 8 PSF area dead load has been added to account for tile load MBA on this floor. There are different joist series of the same depth specified on this floor system.  Verify when installing that the proper TJI® joists are used in the appropriate area. Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior toconstruction. TJI 560 will be replaced with IB-700.