Loading...
HomeMy WebLinkAbout06020122 Resubmittal Info BUILDER RE-SUBMITTAL For Incomplete permit submittals DATE OF RE-SUBMITTAL: r~- 1)- [g cg [g 0 ~? 0~~ ' !! ill =0 \ i!"- I I \ , I~~I APR 2 0 2006 uj/ I Name of Reviewer: ~ 't t-'- ;>.LJ BUILDER NAME: If ff . Contact #: /J1e/(/I.lC( -c:JY(,-2 '1(2 , Project Address: 7'-16'1 /11,.1/ J/,t{ ( pc Lot & Subdivision: 70 5'1a.. f'(jlv( flK Comments: (lct<.i'-l1- -If- ~ kev - ~6 ~ f' '---- e Vo-. ("" " ~ Ot22- . . ..~..... .~-, '. '~- '\ o ~~ (I Y Re-Review Fees: Residential $133.50 Commercial $267.00 D I s/pennits/Forms/Re-Submittal for Review ~t>-"T:.~ ~ ~'~~ ~t~~ J' Schneider This Plot Plan Prepared For: R.H. of Indiana Lot # 90 ,containing 8,273 SJ.:l:, in Stanford Pork Section # 1 INSTR. # 200500009385 P.C. # 3, Slide # sn CERllACATE of CORRECTION INSTR. # 200500044195 Cloy Twp, HamUton County Sec 29, Tl aN, RJE 3464 Millbroe Drive Carmel, IN 46074 Prepared Dote: 02/15/06: 8y: AMA Proposed Buyer(s): Colby Ross McCarkel The Schn,elder Corporation 8901 0Us Avenue Historic I'art RarriaoD Indlanapolll. Indiana 46216-1037 317-1126-7100 317-626-7200 Fl:t. Ent!neerio& 3urvOJin& Lmdscape Architecture GI3 .1J3 Geology Plot Plan Legend (50'RjW) []QQ]] Proposed Grades 000.0 Existing Grades __000.0-- Contour Grade * Approx. Lateral Location - . - Sanitary Sewer Lines -11'- Storm Sewer Lines - IJ - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) 11III Curb Inlet (Storm) D End Section (Storm) .... Fire Hydrant - 0 C C - 0 0 0 - Flow Line of swale - Building Line (BL / BSL) - - - - - - - Easement Une Community Restrictions: Side Yard =j' min. Rear Yard = N/A Aggregote = 6 (B.H.) Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 916.30 Downstream Manhole, TC=917.30 per plan. R.H. of Indiana Finished Floor Elevation Information Pad Grode = 917.1 per plan Pad Grade + 0.7' = Garage FFE (917.8) Garage FIT + 1.5' = Residentiol FFE (919.3) Residential FFE - 9.0' = Basement FFE (910.3) Note : The garage fllllshed itoor' elewtion is 1.5' above the curb at the drive, per plan. 915.0 N.P.=~08.80 ___ 100 YR.-912.52 ____ C.A. f13____ LAKE N3 VAR. D.U.&S.S.E. & S.L.E. & l.M.A.E.&R.D.E. & P.I.E.E. 75.13' Ground Cover Calculations Drive = 513 SF:!: Public Walk = 230 SF:!: Private Walk =44 SF:!: Hydroseeding =3.144 SF:!: Sod = 321 SY:!:, from Rear of residence 15' D.E. - -----, 43.6' 36.6' 1916.11 I I I w c; oi I ~ 8a soo 40.00 SOO KENSNGTON C I fRM&MSY I 1:l RESOENCE .,; I N 'ill ~ I SUMP 0 PUMP 12.00 Sidewalk to be placed l' from property line. 4' from bock of curb, per plan. 'ill ~ N P o q T ~ on '-' ~ .63' 5S' ~ TWO CAR ~ GARAGE 6.3' .62'8 20.7S' , G.B.l. oJ- TYPICAL SWAlE SEC110N .L. ;f OJ.E. 16' 26.0' DRIV[ 36.0' ~E ~U Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'). however a dw~ling may be increased in height to thirty-five feet (35') provided the side and rear yards-- are increased on additional one foot (1') for each ~ 30 0' one foot (1') the structure exceeds the first B~B twenty-five feet (25') In height 44.49' I 5' WALK TC-916.26 PER PLAN 916.4 .+-e- TC=917.30 PER PLAN 5lR. , 720 Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map # 18057 0205F for City of Carmel, Indiana (maps dated Februal)' 19, 2003). SGNA lURE : DAlE: SGNA lURE REPRESENTS CON~RMA nON OF RECEIPT OF PLOT PLAN BY CUSTOI.fER. Nate: This drawing is based on construction plans or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Controctars should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediotely: failing to do sa resuits in the contractors assumption of all liability. Note: The basement elevation, depicted hereon, has been determined and based upon the pod grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soli conditions, or son t)'pes has been provided or stated on said plans. It Is recommended that the basement finished floor elevations be at leost two feet (2') above the normal pool elevation of any adpining bodies of water, unless a study af facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional constructicn techniques should be incorporated b alleviate future pr,X)lems. Nate; Sump pump(s) to be placed by builder as needed. ,. Lot # 90 Vb06,0049078 ~ ~ =li3.= ~ Assumed North Scale : 1" = 30' 1915.51 r I I w c; oi ~ DetaR of Ground/ Storm Water flow pattern for individual lots. 0, U') '" - I t :M; ,WI 15.0' - -~ Note: Sunder to ensure positive drainage away from structure{s). REVlSON 11 NEW ElEVA nON PO , 29-28949 \b06.00S2379 04/13/06 III.A FLOOD HAZARD STATEMENT CERTIFICATION --- ,\\\\\\\\\11111/11111111/11. #"'~S L C, ~I/% #' ~ '\ ......:.... ;.p/~,~ >>~~ ." ST~ '" (h "" i!$<.:) ,"c,' ...F?J.... ".A~ ~ .'#'.' N <';,.. """-::;:::; $fc--... ....Q:-v 0 0\ A? ~~: . .."""~ I ( 50303 ! I .::; ":. : :::: ~ .... STATE OF.... ~ ~ /.... ....<\ tit ~{A '..!.J\tOIA""!':'" ~~~ ~..,#; .............t'\" ~ ~h/, SUR~ \.~# Wlllllllllllilll!\\!\\\\" Oc-l~ / ~ ,'.. , '- LARGE FORMAT PLANS