Loading...
HomeMy WebLinkAbout060300128 Site Plan - ~ The Schneider Corporation 8901 otis Avenue Historic Fort Harrison lndianapolia, Indiana. 46216-1037 317-826-7100 317-826-7200 FAX Engin..rlD& . -- Landscape Architecture GIS 'US Geology c.;ly This Plot Plan Prepared For. R.H. of Indiana Lot # 47 ,containing 6,622 S.F.:!:, in Stanford Par1< Section # 1 INSTR. # 200500009385 P.C. # 3. Slide # sn CERllACA TE of CORRECllON INSTR. # 200500044195 Oay Twp. HamDton County Sec 29. Tl8N. R3E 13688 Stonford Drive Carmel. IN .f6074 Prepared Date: 03/10/06 By: AMA Proposed Buyer(s): INVENTORY ( 50' R/W) Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregate = 6' (8,H.) R.H. of Indiana Finished Floor Elevotion Information Pod Grode = 915.5 per plan Pod Grode + 0.7' = Garage FFE (916.2) Garage FFE + 1.5' = Residential FFE (917.7) Residential FFE - 9.0' = Basement FFE (908.7) Note : The garage finished floor elevation is 1.5' above the curb at the drive, per plan. Ground Cover Calculations Drive = 513 SFf Public Walk = 194 SF f Private Walk = 52 SF f Hydroseedin9 = 2,348 SF f Sod = 222 SYf, from Rear of residence 'I '" o:! m wi '" o~1 w 0-1,,; '" '" Sidewalk to be placed " from property line, 4' from back of curb, per pion. z .~ o -f; 7 ~OPE:';':' "'~, S\..OpE. TYPICAL SWAL[ SECllON Plot Plan Legend []QQ&J Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grade * Appro,. Laterai LOGotion - . - Sanitary Sewer Lines -IT- Storm Sewer Lines - VI - Water Service lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Iniet (Storm) IIllI Curb Inlet (Storm) D End Section (Storm) .... Fire Hydrant - <> 0 <> _ <> <> <> _ Flow line of swale Building Line (8L / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Top of Costing Information Upstream Manhole, TC= 915.20 Downstream Manhole, TC=916.30 per pion. Detail of Ground/ Storm Water flow pattern for indi'viduallots. [Q] -M- -h- - - -- Note: Builder to ensure positive drainoge away from structure(s). 120.40' ~ ~ ~ 2.'"&' ...~ '" u< ~ ~~ ~ 12.00' i5 ~ o "" 0; 8 '" ~ ~ i!l ~ 100 ~ .00' ~ >- bl %~% 81il~~ ~12e::::w _ Vl L::: e::34.38, N ~ g; ~ 120.40' 5.5' 915. :;;: 21.04 .. 31.33 ~ % ...~ u< ~ Frood Hazard Statement: The aCClJracy of any flood hazard data shown on this report is subject 10 map scale uncertainty and to any other uncertainty in location or elevation on the referenced ffood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003). )l-yr:,-2'I (L Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The SGhneider Corporation does not warrant the occurocy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy foond on this drawing shouid be reported to The Schneider Corporation immediately. foiling to do so results in the contractors assumption of 011 liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided the side and rear yards ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. Note: The basement elevation, depicted hereon, has been determined and based upon the pad grades and/or cOntours taken from the construction pions for this subdivision, Unless stated, no information about fluctuating water tables, soil conditions, or soil twes hos been provided or stated 00 said plans. It is recommended that the basement finished floor elevations be at least two feet (2') above the normal pool elevation of any adjoining bodies of water, unless 0 study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement e1eV<ltion should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to olleviate future problems. Note: Sump pump(s) to be placed by builder os needed. Lot # 47 Vb06.0050287 ij ~ =li3.= TG-915.20 PER PLAN ij Assumed North Scale: 1- =: 30' . 915.2 26.0' . is ~ !l, vi a vi 0 ... ;:; '" ,,; i 'b '" '" .+m: --I 1 "-)> ~ [ 1 ~~ :z: II c.... .-, I ~~: ~ CJ I ... 1 ~ CJ: ::::0 I g -I D:: <: rrl 1 r 30.0' 8-B . " t ~~ TC-916.30 PER PlAN FLOOD HAZARD STAITMENT CERllFICA 1l0N ,\I\\\\\IIIIII1III//JIIII/ ~"''''\ L c, ~~ # ~'\ ......:.... ;Ph;%, ff t..~ ......0 's T E:~e-........ A~ ",~...",,'v No 0'..--:;:0'" I ( 50303 ) , ~ : ~ % \. STATE OF ..... ~ ~ ./ .... ....<\ ~ ~('~ ...;IyO'A~l>;'... ~~~ % '#; "'S"'U'''ii~i\. ~ ,# ~111. I\ ~ ~\~ /1111/11/1/1111111\\\\\\\\\ -\::L-"-f-fi ~GNA T\JRE : OATE: SiGNAT\JRE REPRESENTS CON~RMATION Of RECEIPT Of PLOT PLAN 8Y CUSTO~ER,