HomeMy WebLinkAbout41-E0-1 GENERAL NOTES AND LEGENDSaSINGLE POLE TOGGLE SWITCH +4'-0", LOWER CASE (ie: a)LETTER DENOTES LIGHTING CONTROLDIMMER SWITCHD3-WAY TOGGLE SWITCH3WOS(a)VS(a)DUPLEX RECEPTACLE - MOUNTED 18" A.F.F. U.N.O.IG-ISOLATED GROUNDGFI-GROUND FAULT CIRCUIT INTERRUPTEDWP-WEATHER PROOFDED-DEDICATED CIRCUITGFIRECEPTACLE TO BE MOUNTED ABOVE COUNTERSPECIAL PURPOSE OUTLETJUNCTION BOXJCONCEALED CONDUIT AND WIRE RUNEXPOSED CONDUIT AND WIRE RUNGROUND WIREFLEXIBLE CONDUIT CONNECTION2x4 LIGHT FIXTURE2x2 LIGHT FIXTURE1x4 LIGHT FIXTURESTRIP LIGHT FIXTUREWALL MOUNTED EMERGENCY LIGHT UNITMOUNTED AT 8'-0" A.F.F. OR 1'-0" BELOW CEILING AS APPLICABLEEXIT SIGNSHADING INDICATES LIT FACE SIDEARROW INDICATES EXIT DIRECTIONSITE LIGHTING POLE LIGHTCEILING MOUNTED LIGHTING CONTROLVS-VACANCY SENSOROS-OCCUPANCY SENSORDL-DAYLIGHT SENSORMOTORMANUAL MOTOR STARTER WITH THERMAL OVERLOADTDISCONNECT SWITCHPANELBOARDDATA/PHONE OUTLET MOUNTED AT 18" A.F.F. U.N.O. WITH A 3/4"C RUN UPIN WALL AND STUBBED OUT ABOVE SUSPENDED CEILING, TERMINATEWITH INSULATED BUSHING, PROVIDE PULL WIREWALL MOUNTED SECURITY KEY PAD ROUGH-IN WITH 1" CONDUITBB1MECHANICAL EQUIPMENT TAGWALL MOUNTED VACANCY SENSOR SWITCH, LOWER CASE (ie: a) LETTERDENOTES LIGHTING CONTROLWALL MOUNTED OCCUPANCY SENSOR SWITCH, LOWER CASE (ie: a)LETTER DENOTES LIGHTING CONTROLLEGENDNOTE: NOT ALL ITEMS MAY BE USED.SYMBOLDESCRIPTIONKEYNOTE TAGREVISION TAG11VSOSDLIGDEDWPQUAD RECEPTACLEMOUNTED AT 18" A.F.F. U.N.O.AC ALTERNATING CURRENTADA AMERICAN DISABILITIES ACTADJ ADJUSTABLEAFF ABOVE FINISHED FLOORAHJAUTHORITY HAVING JURSIDICTIONAMP AMPERE (AMP, AMPS)ANSI AMERICAN NATIONAL STANDARDS INSTITUTEAPPROXAPPROXIMAT(E), (ELY)ARCH ARCHITECTAWG AMERICAN WIRE GAUGEC/BCIRCUIT BREAKERCKT CIRCUITCLG CEILINGCuCOPPERDEDDEDICATEDDIA DIAMETERDISC. DISCONNECTDSDAYLIGHT SENSORDWG DRAWINGEF EXHAUST FANELEC ELECTRICEUHELECTRIC UNIT HEATEREWC ELECTRIC WATER COOLEREXEXIT SIGNFACPFIRE ALARM CONTROL PANELFLEX FLEXIBLEFLR FLOORGALV GALVANIZEDGC GENERAL CONTRACTORGFCIGROUND FAULT CIRCUIT INTERRUPTERGNDGROUNDHP HORSEPOWERHRHOURHVAC HEATING, VENTILATING, AND AIR CONDITIONINGHZ FREQUENCYKW KILOWATTMAX MAXIMUMMCBMAIN CIRCUIT BREAKERMINMINIMUMMISC MISCELLANEOUSMLOMAIN LUG ONLYMTDMOUNTEDMTL METALNA NOT APPLICABLENIC NOT IN CONTRACTNLNIGHT LIGHTNTS NOT TO SCALEOSOCCUPANCY SENSORPCPHOTOCELLRECPT.RECEPTALCE(S)RM ROOMRTU ROOF TOP UNITSECT SECTIONSHT SHEETSWTSWITCHT.C.TIME CLOCKTRTAMPER RESISTANTTYPTYPICALUNO UNLESS NOTED OTHERWISEVA VOLT AMPEREVAR VARIABLEVERT VERTICALVSVACANCY SENSORWWIRE OR WATTW/ WITHW/O WITHOUTWPWEATHERPROOFABBREVIATIONSNOTE: NOT ALL ITEMS MAY BE USED.ELECTRICAL NOTES AND SPECIFICATIONS1.ALL WORK SHALL COMPLY WITH ALL THE APPLICABLE LOCAL, MUNICIPAL AND FIRE CODES. THE WORK SHALLBE IN TOTAL COMPLIANCE WITH THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION.2.REVIEW ADOPTED CODES AND CODE AMENDMENTS WITH THE LOCAL GOVERNING AUTHORITIES AND BECOMEFAMILIAR WITH THE LOCAL REGULATIONS RELATING TO THE WORK.3.CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTION FEES AS REQUIRED FOR HISPORTION OF THE WORK.4.CONTRACTOR SHALL SUBMIT UTILITY COMPANY SERVICE APPLICATIONS.5.CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF FINALCOMPLETION.6.CONTRACTOR SHALL COORDINATE ALL WORK WITH THE RESPECTIVE TRADES AND VERIFY LOCATIONS FROMTHE ARCHITECTURAL DRAWINGS, FIELD MEASUREMENTS AND SUPPLIER SHOP DRAWINGS.7.COORDINATE EQUIPMENT VOLTAGE, PHASE, BREAKER SIZE, AND DISCONNECTING MEANS WITHSUBCONTRACTORS PROVIDING EQUIPMENT PRIOR TO ORDERING AND INSTALLATION OF ANY EQUIPMENT,PANELS, BREAKERS, CONDUIT AND WIRE, ETC.8.WORK REQUIRED OF ANY TRADE MAY BE SHOWN ANYWHERE ON ANY DRAWING OR IN ANY PART OF THESPECIFICATIONS.9.CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS OF ALL TRADES AND SHALL INCLUDE ANYELECTRICAL WORK INDICATED OR REQUIRED BY ANY TRADE. THE CONTRACTOR ACKNOWLEDGES BYSUBMITTING A BID THAT CONSTRUCTION DOCUMENTS HAVE BEEN REVIEWED, AND THAT THE INFORMATIONSHOWN AND DESCRIBED IS SUFFICIENT TO PREPARE A COMPLETE AND ACCURATE BID FOR A COMPLETE,FINISHED PROJECT. ANY CLARIFICATIONS, DISCREPANCIES, OMISSIONS, REQUEST FOR ADDITIONALINFORMATION, OR UNUSUAL CONDITIONS ARE TO BE BROUGHT TO THE ARCHITECT'S ATTENTION FORRESOLUTION IN WRITING PRIOR TO SUBMITTING BIDS.10.ALL DIMENSIONS TO BE VERIFIED IN THE FIELD AND WITH SHOP DRAWINGS.11.CONTRACTOR SHALL COMPLY WITH ALL IDENTIFICATION REQUIREMENTS OF THE NEC12.INDEPENDENT ELECTRICAL EQUIPMENT SUPPORT WIRES INSTALLED WITHIN A DROP CEILING SHALL BEDISTINGUISHED BY COLOR, TAG OR OTHER PERMANENT MEANS13.LAYOUT OF EQUIPMENT, ACCESSORIES AND WIRING ARE DIAGRAMMATIC AND DO NOT INDICATE EVERY BOX,CONDUIT, WIRING OR SIMILAR ITEMS FOR A COMPLETE INSTALLATION.14.CUTTING OF ANY STRUCTURAL MEMBER SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TOWORK BEING DONE.15.WHEREVER CIRCUIT CONDUCTORS ARE SPLICED IN A BOX, ANY EQUIPMENT GROUNDING CONDUCTORASSOCIATED WITH THESE CIRCUITS MUST BE BONDED (“PIGTAILED”) TO THE BOX.16.CIRCUIT NUMBERS GIVEN ON DRAWINGS ARE FOR CIRCUIT IDENTIFICATION ONLY. THE CONTRACTOR SHALLINSTALL CIRCUITRY AS GOVERNED BY FIELD CONDITIONS. CONTRACTOR SHALL KEEP A TYPED RECORDCORRELATING TO THE GIVEN AND ACTUAL CIRCUIT NUMBERS AND PROVIDE THIS INFORMATION ALONG WITHTHE TYPED WRITTEN PANEL DIRECTORIES.17.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE OTHER CONTRACTORS. RELOCATEEQUIPMENT AS REQUIRED TO AVOID CONFLICT WITH OTHER TRADES. ALL DEVIATIONS SHALL BE APPROVEDIN WRITING BY THE ARCHITECT PRIOR TO THE EXECUTION OF THE WORK.18.RACEWAYS SHALL BE A MINIMUM 3/4" EMT FOR LIGHTING AND APPLIANCE BRANCH CIRCUITRY AND MINIMUM1" EMT FOR TELEPHONE & DATA. ONE-HALF INCH EMT ALLOWED FOR SINGLE OUTLET AND SWITCHLOCATIONS.19.ALL LINE VOLTAGE CONDUCTORS SHALL BE COPPER, MINIMUM #12 GAGE, 98% CONDUCTIVITY WITH 600 VOLTINSULATION, SUITABLE FOR 60°C OPERATING TEMPERATURE, APPROPRIATE FOR DRY OR WET LOCATIONS,THW, THWN OR THHN FOR BRANCH CIRCUITS, SIZES #10 AND LARGER TO BE STRANDED. FEEDERS ANDMOTOR POWER CIRCUITS SHALL BE THW OR THHN, COPPER WITH 600 VOLT INSULATION, SUITABLE FOR 75°COPERATING TEMPERATURE AND APPROPRIATE FOR DRY OR WET LOCATIONS. LOW VOLTAGE CONDUCTORSSHALL BE MINIMUM #14 GAGE.20.RACEWAY FITTINGS SHALL BE GALVANIZED STEEL. EXTERIOR MOUNTED RACEWAYS SHALL BE GALVANIZEDRIGID STEEL WITH THREADED FITTINGS, PROTECTED WITH GALVANIZED COATING. EXTERIOR MOUNTEDDEVICES SHALL BE INSTALLED IN WEATHERPROOF ENCLOSURES.21.EXTERIOR MOUNTED CABINETS, ENCLOSURES, ETC. WHERE SUBJECT OT DAMP OR WET LOCATIONS, SHALLBE MOUNTED WITH MINIMUM ¼” AIRSPACE BETWEEN THE EQUIPMENT AND THE WALL OR OTHER SUPPORTINGSURFACE. EQUIPMENT INSTALLED IN WET LOCATIONS SHALL BE WEATHERPROOF.22.WHERE CONDUIT PASSES FROM THE INTERIOR TO THE EXTERIOR OR UNCONDITIONED SPACES THERACEWAY OR SLEEVE SHALL BE FILLED WITH AN APPROVED MATERIAL (POLYWATER FST OR EQUAL) TOPREVENT CIRCULATION OF WARM AIR TO A COLDER SECTION OF THE RACEWAY OR SLEEVE.23.INSTALL FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE RACEWAY CROSSES CONTROLAND EXPANSION JOINTS24.PROVIDE PULL WIRE IN ALL EMPTY CONDUITS.25.ALL BRANCH CIRCUITS SHALL BE GROUPED INTO PHASE BALANCED MULTIPLE CIRCUIT HOME RUNS. AMAXIMUM OF 4 CIRCUITS PER SINGLE HOME RUN.26.THE CONTRACTOR SHALL PROVIDE A COMPLETE CONDUCTOR AND RACEWAY SYSTEM FOR ALL CIRCUITDEVICES INDICATED ON THE PLANS EVEN THOUGH NOT DELINEATED.27.WIRES FOR 120 VOLT BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH FROM PANEL TO CENTER OF LOADSHALL NOT BE SMALLER THAN #10 AWG.28.INSTALLATION OF ALL LIGHTING FIXTURES SHALL INCLUDE ALL NECESSARY CONDUIT (SOLID OR FLEXIBLE),WIRING, JUNCTION BOXES, ETC., FOR CIRCUIT DEVICES.29.VERIFY ALL CEILING SYSTEM TYPES WITH ARCHITECTURAL PLANS PRIOR TO ORDERING LIGHTING FIXTURESAND PROVIDE REQUIRED HARDWARE AND FRAMES REQUIRED FOR CEILING TYPE.30.ALL CEILING MOUNTED DAYLIGHT SENSORS, CEILING MOUNTED OCCUPANCY/VACANCY SENSORS, AND/ORWALL MOUNTED DIMMER SWITCHES AND OCCUPANCY/VACANCY SENSORS TO BE COMPATIBLE WITH THEFIXTURES INDICATED TO BE CONTROLLED AND SHALL BE INSTALLED AND WIRED IN ACCORDANCE WITHMANUFACTURER'S RECOMMENDATIONS.31.EMERGENCY BATTERY BACKUP LIGHT FIXTURES SHALL BE CIRCUITED TO LOCAL AREA LIGHTING CIRCUITAHEAD OF ANY SWITCHING UNLESS NOTED OTHERWISE.32.ALL PANELS POWERING EMERGENCY LIGHTING, EXIT SIGN, FIRE ALARM, OR AUTOMATIC DOOR CIRCUITSSHALL HAVE LISTED SURGE PROTECTION DEVICE.33.LAY-IN LIGHT FIXTURES: SHALL BE SECURED TO THE CEILING GRID. LIGHTING FIXTURES WEIGHING LESSTHAN 10 LB SHALL HAVE ONE, NO. 12 GAUGE SAFETY WIRE CONNECTED FROM THE FIXTURE HOUSING TO THESTRUCTURE ABOVE. LIGHTING FIXTURES WEIGHING GREATER THAN 10 LB BUT LESS THAN 56 LB SHALL HAVEIN ADDITION TWO NO. 12 GAUGE HANGER WIRES CONNECTED FROM THE FIXTURE HOUSING (NOT THEDETACHABLE END PLATES) TO THE STRUCTURE ABOVE. LIGHTING FIXTURES WEIGHING 56 LB OR MORE SHALLBE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. PENDENT-HUNGLIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING NO LESS THANNO. 9-GAUGE WIRE OR AN APPROVED ALTERNATIVE SUPPORT. THE CEILING SUSPENSION SYSTEM SHALL NOTPROVIDE ANY DIRECT SUPPORT. RIGID CONDUIT SHALL NOT BE USED FOR ATTACHMENT OF THE FIXTURES.34.ALL CIRCUITRY TO BE RUN CONCEALED UNLESS OTHERWISE INDICATED.35.ALL NEW MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHERRECOGNIZED TESTING LAB.36.ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS.37.WIRING DEVICES:A.RECEPTACLES SHALL BE PROVIDED WHERE SHOWN AND BE NEMA 5-20R, COMMERCIAL GRADE.B.SWITCHES SHALL BE PROVIDED WHERE SHOWN AND BE COMMERCIAL GRADE.C.COVER PLATES SHALL BE AS DIRECTED BY ARCHITECTD.RECEPTACLES LOCATED WITHIN TOILET ROOMS, WITHIN 6 FEET OF SINKS AND WATER SUPPLIES,SERVING WASHING MACHINES, WATER COOLERS, ETC., AND MOUNTED ON THE EXTERIOR SHALL BE GFCICOMMERCIAL GRADE.E.RECEPTACLES SHALL BE TAMPER-RESISTANT THROUGHOUTF.ALL WALL SWITCHES IN ROOMS WITH CEILING MOUTNED VACANCY SENSORS SHALL BE LOW VOLTAGEMOMENTARY TOGGLE SWITCH TYPE.38.ALL SINGLE PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 AMPS OR LESS, ANDTHREE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 AMP OR LESS INSTALLED IN ORSERVING BATHROOMS, KITCHENS, ROOFTOPS, DEDICATED MECHANICAL SPACES, OUTDOORS, WITHIN 6 FEETOF SINKS, INDOOR WET LOCATIONS, SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION .39.PROVIDE BONDING JUMPER AT EACH HOT WATER HEATER BETWEEN THE COLD AND HOT WATER PIPING.40.RECEPTACLES ON OPPOSITE SIDES OF A FIRE RATED WALL ASSEMBLY SHALL BE HORIZONTALLY SEPARATEDBY NOT LESS THAN 24 INCHES OR SHALL BE PROTECTED WITH INTUMESCENT PUTTY PADS)41.CORING AND PENETRATIONS: FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS.ANY CUTTING, DRILLING OR CORING SHALL BE DONE WET TO MINIMIZE SPREAD OF DUST. WEATHERPROOFALL PENETRATIONS THRU FOUNDATION AND EXTERIOR WALLS. FIREPROOF ALL CONDUITS OPENINGSBETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION WALLS WITH AN APPROVED UL LISTED FIRERETARDANT MATERIAL.42.COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF MOTORS AND OTHER EQUIPMENT REQUIRINGPOWER.A.FINAL CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH "LIQUID TIGHT" FLEXIBLE STEEL CONDUIT, ¾"MINIMUM.B.PROVIDE LOCAL DISCONNECT FOR ALL MOTORS. VERIFY MANUFACTURE'S RECOMMENDED DISCONNECTSIZE PRIOR TO ORDERING AND INSTALLATION.C.PROVIDE STARTERS FOR ALL MECHANICAL EQUIPMENT WHICH REQUIRES INTERLOCKING. COORDINATESIZE AND LOCATION OF STARTERS WITH MECHANICAL CONTRACTOR.D.FOR ALL AC MOTORS NOT PROVIDED WITH BUILT-IN THERMAL OVERLOAD PROTECTION, PROVIDE MANUALMOTOR STARTERS WITH OVERLOAD HEATER ELEMENTS SIZED TO THE NAMEPLATE CURRENT RATING OFTHE MOTOR. SMALL AC MOTORS WITH BUILT-IN THERMAL OVERLOAD PROTECTION, PROVIDE HORSEPOWER RATED TOGGLE TYPE DISCONNECT SWITCH.43.ALL ELECTRIC DISTRIBUTION EQUIPMENT SHALL BE FULLY-RATED.44.ELECTRICAL PANELS SHALL HAVE BOLT-ON TYPE CIRCUIT BREAKERS WITH SHORT CIRCUIT INTERRUPTINGRATINGS TO EXCEED THE AVAILABLE SHORT CIRCUIT CURRENT.45.ALL 120 VOLT CIRCUITS SHALL HAVE A DEDICATED NEUTRAL46.FIRE ALARM SYSTEM:FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD. PROVIDE A COMPLETE ADDRESSABLE FIRE ALARM SYSTEMINSTALLED IN ACCORDANCE WITH ALL GOVERNING AUTHORITIES WHICH HAVE JURISDICTION OVER THISPROJECT. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO ALL EQUIPMENT, DETECTION DEVICES, HEATDETECTORS, SMOKE DETECTORS, DUCT SMOKE DETECTORS, REMOTE DUCT DETECTOR TEST SWITCHES,AUDIBLE/VISUAL DEVICES, FLOW/TAMPER SWITCH WIRING, PULL STATIONS, FIRE ALARM CONTROL PANEL,REMOTE ANNUNCIATOR PANEL, KNOX BOX, PROPER ADDRESSING OF EQUIPMENT, CONDUIT, BOXES, WIRE,ETC. AS REQUIRED FOR A COMPLETE SYSTEM. CONTRACTOR SHALL PROVIDE TELEPHONE CONNECTION FORFIRE ALARM PANEL AND COORDINATE WITH TELEPHONE SERVICE PROVIDER FOR CONNECTION47.LIGHTING SYSTEM FUNCTIONAL TESTING:A.FUNCTIONAL TESTING SHALL BE PERFORMED IN COMPLIANCE WITH THE IECC BY THE GENERALCONTRACTOR TO ENSURE THAT THE HARDWARE IS CALIBRATED, ADJUSTED, PROGRAMMED AND INPROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS ANDMANUFACTURER'S INSTALLATION INSTRUCTIONS.B.TESTING SHALL CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTS FOROCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE.C.CONFIRM THAT THE TIME SWITCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TOTURN THE LIGHTS OFF.D.CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTO SENSOR CONTROLSREDUCE ELECTRIC LIGHT BASED ON THE AMOUNT OF USABLE DAYLIGHT IN THE SPACE AS SPECIFIED.48.SUBSTITUTIONS: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DESIGN MODIFICATIONS RESULTING FROMEQUIPMENT SUBSTITUTED FROM THAT WHICH IS SPECIFIED. MODIFICATIONS INCLUDE BUT NOT LIMITED TO:REQUIRED WORKING AND CODE CLEARANCES; LOCATIONS AND DIMENSIONS OF OPENINGS; STRUCTURALCOORDINATION; BREAKER, WIRE, CONDUIT SIZES. SUBSTITUTIONS OF LIGHT FIXTURES SHALL BE VERIFIEDCOMPLIANT WITH THE ENERGY CODE BY THE CONTRACTOR.49.SHOP DRAWINGS:A.SUBMIT COORDINATED SHOP DRAWINGS FOR ALL EQUIPMENT, LIGHT FIXTURES, PANELS, SWITCHGEAR,ETC.B.SUBMIT ALL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO ARCHITECT'S OFFICE PRIOR TOPURCHASE, FABRICATION, AND INSTALLATION.C.CONTRACTOR SHALL HIGHLIGHT OR SUMMARIZE ANY DEVIATIONS IN THE SHOP DRAWING SUBMITTALSFROM THE CONTRACT DOCUMENTS.50.MANUALS: DOCUMENTS DESCRIBED BELOW SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYSOF THE DATE (U.N.O.) OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY:A.SUBMITTAL DATA STATING EQUIPMENT SIZE AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENTREQUIRING MAINTENANCEB.MANUFACTURER'S OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENTREQUIRING MAINTENANCE, EXCEPT EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIREDROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED.C.NAME AND ADDRESS OF AT LEAST ONE SERVICE AGENCYD.A NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING RECOMMENDED SET-POINTSE.AS-BUILT DRAWING(S) OF ELECTRICAL POWER SYSTEMS WITHIN 30 DAYS OF SYSTEM ACCEPTANCEKPELECTRIC STRIKE ROUGH-IN WITH 1" CONDUITESELECTRIC CONTACTOR ROUGH-IN WITH 1" CONDUITECSIMPLEX RECEPTACLEINFO@ALLENPEPA.COM TEL: (630) 578-1105 215 FULTON ST., GENEVA, IL 60134PROJECT NO.DRAWN BYCHECKED BYSHEETSchematic Design:Design Development Bidding: Permit:POST BID/PERMIT REVISIONS:ISSUE DATE:ALLEN+PEPA COPYRIGHTALLEN PEPA A R C H I T E C T S MGN CONSULTING ENGINEERS, INC. 635 BUTTERFIELD ROAD SUITE #310 OAKBROOK TERRACE, IL 60181 PHONE (630) 627-6078 WWW.MGN.ENGINEERING1/12/2022 8:09:09 AMC:\Users\Amanda Kerner\Documents\21-014 Higher Ground Carmel_akernerK6S8R.rvt HIGHER GROUND CARMEL CARMEL, IN 46033 21-0211/28/2212/30/21No.DateDescriptionOF 21FOR PERMIT1/28/22GENERAL NOTES& LEGENDSE0-115