Loading...
HomeMy WebLinkAbout05-G1-5 ACCEISSIBILITY STANDARDSMEN13141516MANUEVERING CLEARANCE @ DOORSPER ILLINOIS ACCESSIBILITY CODESECTION 400, ILLUSTRATION B, FIG. 25NOTE: Y= 48" MIN. IF DOOR HAS CLOSER.NOTE: Y= 54" MIN. IF DOOR HAS CLOSER.NOTE: Y=48" MIN. IF DOOR HAS BOTH LATCH AND CLOSER.NOTE: X=36" IF Y = 60" MIN.X= 42" IF Y = 54" MIN.NOTE: X=12" IF DOOR HASBOTH CLOSER AND A LATCHNOTE: (4.19.4 ADAAG) EXPOSED PIPES ANDSURFACES. HOT WATER AND DRAIN PIPES UNDERLAVATORIES SHALL BE INSULATED OR OTHERWISECONFIGURED TO PROTECT AGAINST CONTACT.THERE SHALL BE NO SHARP OR ABRASIVESURFACES UNDER LAVATORIES.BASE CABINETS: removable under the full 30 in. minimum frontage of the counter. The finished floor shall extend under the counter to the wall. See 400.360(d 5EPLUMBING: Where sinks are installed to be adjustable in height, rough-in plumbing shall be located to accept connections of supply and drain pipes for sinks mounted at the height of 28 in. See 400.360(d)5BOPENCLEAR FLOOR SPACE: A clear floor space at least 30 in. by 48 in. at all appliances in the kitchen, inc. the range, oven, refrigerator, dishwasher, and trash compactor. See 400.360(d) 2SINK: The depth of a bowl shall be no greater than 6-1/2 in. Only one bowl of double-bowl or triple-bowl sinks needs to meet this requirement. See SECT.400.360(d 5CROUTE:Accessible kitchens and their components shall be on an accessible route.CLEARANCE: Where counters provide the knee clearances specified in Section 400.310(n)(7)(B), clearances between those counters and all opposing base cabinets, countertops, appliances, or walls in kitchens shall be 40 in. min.except in U-shaped kitchens, where such clearances shall be 60 in.OPENCLEAR FLOOR SPACE: a clear floor space of 30 in. by 48 in. 19" max of the clear floor space may extend underneath the counter.The knee space shall have a min.clear width of 30 in. 400.360(d)4DSINK ANDCOUNTERSINK ANDCOUNTERELEVATIONPLANSCALE: 1/4"=1'-0"KITCHENWORK SURFACELOWEREDWORKSURFACEKITCHENWORK SURFACECLEARFLOORSPACECLEARFLOORSPACESINK and COUNTER: replaceable as a unit, or adjustable ht. btwn 28" and 36", or fixed ht of 34" or less. See SECT. 400.360(d) 5BFAUCET: lever operated or push-type operation. See 400.360(d)5DWORK SURFACE: at least (1)30" section of counter replaceable as a unit, or adjustable ht. btwn 28" and 36", or fixed ht of 34" or less. See 400.360(d)4AFLOORBASE CABINETS: removable under the full 30 in. minimum frontage of the counter. The finished floor shall extend under the counter to the wall. 400.360(d)4B234567891011CLEARCLEARCLEARCLEARFLOORFLOORFLOORFLOORSPACESPACESPACESPACECONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS NO MORE THAN 44 IN. ABOVE FLOOR.IAC-400.310N (ADAAG 4.16.5)NOTE: (4.19.4 ADAAG) EXPOSED PIPES AND SURFACES. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS NO MORE THAN 44 IN. ABOVE FLOOR. IAC-400.310N (ADAAG 4.16.5)CLEARFLOORSPACELobbySIDE WALLBACK WALLCLEAR FLOORCLEAR FLOORLAVATORIESPARALLELAPPROACHLAVATORYCLEARANCESINTERIORELEVATION ACLEARFLOOR SPACESIDE REACHHIGH AND LOWWALKING PARALLELTO A WALLVERTICALGRAB BAR42" MIN.18" CLR.56" MIN.60" MIN.(Y) 42" MIN.(Y) 48" MIN.(Y) 42" MIN.54" MIN.5'-0" MIN.1'-3"MIN. CLEAR1'-3"3'-0"6 1/8""X""X""X""X"48" MIN."Y""Y""Y""Y"4" MAX.4" MAX.4" MAX.4" MAX.HIGHER THAN 27"HIGHER THAN 27"HIGHER THAN 27"HIGHER THAN 27"80" MIN.2' - 6"2' - 6"2' - 6"2' - 6"4' - 0"4' - 0"4' - 0"4' - 0"1' - 7"1' - 7"1' - 7"1' - 7"17"30"48"19" MAX.48"10"30"2' - 6"2' - 6"2' - 6"2' - 6"2' - 4"2' - 4"2' - 4"2' - 4"3' - 0"3' - 0"3' - 0"3' - 0"2"2"2"2"6 1/2"6 1/2"6 1/2"6 1/2"39"-41"39"-41"39"-41"39"-41"54"17"-19"19" MIN.12"42" MIN.33"-36"39"-41"18"4' - 0"4' - 0"4' - 0"4' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10"30"15" MIN48"2' - 6"2' - 6"2' - 6"2' - 6"2' - 4"2' - 4"2' - 4"2' - 4"3' - 0"3' - 0"3' - 0"3' - 0"2"2"2"2"B/MIRROR40" MAX.34" MAX.29" MIN.27" MIN.9" MIN.8" MIN.6" MAX.17" MIN.30"10"34" MAX.48" MAX24" MAX.30" MIN.17"-19"48" MIN.33"-36"12" MIN.12" MIN.36" MIN.36"PUSH SIDEPULL SIDEPUSH SIDEPUSH SIDEPULL SIDE(a) FRONT APPROACH60" MIN.PULL SIDE(b) HINGE SIDE APPROACH(c) LATCH SIDE APPROACHNOTE: ALL ILLUSTRATIONS HEREIN ARE INCLUDED AS REFERENCE ONLY. ALL DIMENSIONS AND CLEARANCES SHOULD BE VERIFIED WITH ADAAG CURRENT GUIDELINES. DISPLAY CONDITIONSINTERNATIONAL SYMBOL OF ACCESSIBILITYSWITCHRECEPTACLEOUTLETDOORTHRESHOLDCOMPRESSED CARPET 1/4" MAX. BELOW THRESHOLDFINISH FLOOR LEVELTHRESHOLD1/2"MAX.1/4"MAX.124' - 0"4' - 0"4' - 0"4' - 0"CLR.CLR.CLR.CLR.2' - 8"2' - 8"2' - 8"2' - 8"MIN.MIN.MIN.MIN.1' - 6"1' - 6"1' - 6"1' - 6"CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS1.THE MINIMUM, CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30 INCHES X 48 INCHES. THE MINIMUM CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE PART OF THE KNEE SPACE REQUIRED UNDER SOME OBJECTS.2.PROVIDE AN ADDITIONAL 12 INCHES WIDTH ON ONE SIDE FOR ALCOVES GREATER THAN 15 INCHES DEEP AND DESIGNED FOR SIDE APPROACH.3.PROVIDE AN ADDITIONAL 6 INCHES WIDTH ON ONE SIDE FOR ALCOVES GREATER THAN 24 INCHES DEEP AND DESIGNED FOR FRONTAL APPROACH. HAZARDS AND PROTRUDING OBJECTS1.OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 INCHES ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4 INCHES INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES.2.OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 INCHES ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT.3.FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG 12 INCHES MAXIMUM FROM 27 INCHES TO 80 INCHES ABOVE THE GROUND OR FINISHED FLOOR. 4. PROTRUDING OBJECTS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. 5. ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80 INCHES ABOVE THE WALKING SURFACE AS MEASURED TO THE BOTTOM OF THE OBSTRUCTION. PARKING 1.SURFACE SLOPES OF PARKING SPACES FOR THE PHYSICALLY DISABLED SHALL NOT EXCEED 1/4 INCH PER FOOT (2% GRADIENT) IN ANY DIRECTION.2.A DISABLED PARKING SPACE SHALL BE LOCATED SO AS NOT TO REQUIRE ITS USER TO WHEEL OR WALK BEHIND ANY OTHER DISABLED OR NON-DISABLED PARKING SPACE.3.IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED AND LOCATED TO PREVENT ENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS,4.EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT, IN WHITE ON DARK BLUE BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 SQUARE INCHES IN AREA AND, WHEN IN THE PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. SIGNS MAY ALSO BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 36 INCHES FROM THE PARKING SPACE FINISHED GRADE, GROUND, OR SIDEWALK. WALKS AND SIDEWALKS 1.WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2 INCHES, AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH.2.SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4 INCH PER FOOT.3.WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER POSSIBLE. GRID OPENINGS WITHIN GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS SHALL BE LIMITED TO 1/2 INCH IN THE DIRECTION OF THE TRAFFIC FLOW.4.WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL, IT SHALL COMPLY WITH THE PROVISIONS OF PEDESTRIANS RAMPS. ENTRANCES/DOORS 1.ALL PRIMARY ENTRANCES AND EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED.2.ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE (1) STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. UBC 1127B.3, 1117B.5 THROUGH 1117B.5.10.3.EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 36 INCHES IN WIDTH, AND NOT LESS THAN 80 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32 INCHES.4.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.5.LEVER HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44 INCHES MAXIMUM ABOVE THE FLOOR.6.THE FLOOR OR LANDING LENGTH ON EACH SIDE OF AN ENTRANCE OR A PASSAGE DOOR SHALL BE LEVEL AND CLEAR AT LEAST 60 INCHES IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48 INCHES OPPOSITE THE DIRECTION OF DOOR AS MEASURED AT RIGHT ANGLES TO THE FACE OF THE DOOR IN ITS CLOSED POSITION. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE WHICH THE DOOR SWINGS SHALL EXTEND A MINIMUM OF 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS, AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS. REFER TO DETAIL NO. 2 ON THIS DRAWING FOR ADDITIONAL CLEARANCE REQUIREMENTS.7.THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE LEVELED WITH A SLOPE NO GREATER THAN 1:2.8.THE BOTTOM 10 INCHES OF ALL DOORS (EXCEPT AUTOMATIC AND SLIDING) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 1 INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST.9.THE MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8-1/2 LBS. FOR EXTERIOR DOORS AND 5 LBS. FOR INTERIOR DOORS. SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY NOT EXCEED 15 LBS.STAIRWAYS1.STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE AND EVERY STAIRWAY REQUIRED TO BE MORE THAN 88 INCHES IN WIDTH SHALL BE PROVIDED WITH NOT LESS THAN ONE INTERMEDIATE HANDRAIL FOR EACH 88 INCHES OF REQUIRED WIDTH. INTERMEDIATE HANDRAILS SHALL BE SPACED APPROXIMATELY EQUALLY WITHIN THE ENTIRE WIDTH OF THE STAIRWAY.2.THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED PARALLEL TO AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP-RESISTANT AS THE TREADS OF THE STAIR.3.WHERE STAIRWAYS OCCUR OUTSIDE A BUILDING, THE UPPER APPROACH AND ALL TREADS SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OF LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP-RESISTANT AS THE TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE.4.ALL STAIR TREAD SURFACES SHALL BE SLIP-RESISTANT.HANDRAILS 1.HANDRAILS AT STAIRWAYS SHALL BE 34 INCHES TO 38 INCHES ABOVE THE NOSING OF THE TREADS.2.HANDRAILS AT STAIRWAYS SHALL EXTEND A MINIMUM OF 12 INCHES BEYOND THE TOP NOSING AND 12 INCHES PLUS THE TREAD WIDTH BEYOND THE BOTTOM NOSING.3.WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF THE STAIR RUN WOULD CREATE A HAZARD, THE EXTENSION SHALL BE MADE AT RIGHT ANGLES, ON THE FACE OF A RETURNING WALL. WHERE THE STAIRS ARE CONTINUOUS FROM LANDING TO LANDING, THE INNER RAIL SHALL BE CONTINUOUS AND NEED NOT EXTEND OUT INTO THE LANDING.4.HANDRAILS ARE REQUIRED ON RAMPS WHEN THE SLOPE EXCEEDS 1:20.5.HANDRAILS AT RAMPS SHALL RUN ALONG BOTH SIDES OF A RAMP, BE CONTINUOUS THE FULL LENGTH, EXTEND AT LEAST 12 INCHES BEYOND THE TOP AND BOTTOM OF THE RAMP, AND THE ENDS SHALL BE RETURNED.6.THE HANDRAIL GRIP SURFACE AT RAMPS SHALL BE MOUNTED BETWEEN 34 INCHES AND 38 INCHES ABOVE THE RAMP SURFACE.7.HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.8.HANDRAILS PROJECTED FROM A WALL SHALL HAVE AN ABSOLUTE CLEARANCE 1-1/2 INCHES BETWEEN THE WALL AND THE HANDRAIL.9.THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4 INCH NOR MORE THAN 1-1/2 INCH IN CROSS-SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN EQUIVALENT SMOOTH GRIPPING SURFACE WITH NO SHARP CORNERS. RAMPS 1.ALL RAMPS USED AS EXITS AND ANY PATH OF TRAVEL HAVING A SLOPE GREATER THAN 1:20 SHALL COMPLY WITH THE REQUIREMENTS OF THIS SECTION. RAMPS SHALL HAVE THE LEAST POSSIBLE SLOPE.2.PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES TO A BUILDING SHALL HAVE A MINIMUM WIDTH OF 48 INCHES. RAMPS SERVING AN OCCUPANCY LOAD GREATER THAN 300 SHALL HAVE A MINIMUM WIDTH OF 60 INCHES.3.ALL RAMPS IN AREAS ACCESSIBLE TO PERSONS WITH DISABILITIES ON A PATH OF TRAVEL OR SERVING EXITS SHALL HAVE A 1:12 MAXIMUM SLOPE WITH CROSS SLOPES NO GREATER THAN 1:50.4.THE LANDING WIDTH SHALL EXTEND PAST THE STRIKE EDGE OF ANY DOOR OR GATE AS SHOWN ON DETAIL NO. 2 ON THIS DRAWING.5.DOORS STANDING IN ANY POSITION SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP TO LESS THAN 42 INCHES OR THE REQUIRED WIDTH BY MORE THAN 3 INCHES.DOOR APPROACH CLEARANCESTOILET TISSUE & SEAT COVERFINISH FLOORTHERMOSTAT3' - 0"3' - 0"3' - 0"3' - 0"4' - 0"4' - 0"4' - 0"4' - 0"1' - 3"1' - 3"1' - 3"1' - 3"4' - 0"4' - 0"4' - 0"4' - 0"FIXTURE AND ACCESSORY MOUNTING HEIGHTS1DOORS IN SERIESSANITARY FACILITIES (GENERAL) 1.ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32 INCH CLEAR, UNOBSTRUCTED OPENINGS.2.ALL SINKS, FAUCET CONTROLS, AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. LEVER-OPERATED, PUSH-TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.3.LAVATORIES SHALL BE MOUNTED WITH A MINIMUM DISTANCE OF 18 INCHES FROM A WALL OR PARTITION TO THE CENTER LINE OF THE FIXTURE. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34 INCHES ABOVE THE FINISHED FLOOR.TOILET ROOM FIXTURES AND ACCESSORIES 1.THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHES AND A MAXIMUM OF 19 INCHES MEASURED TO THE TOP OF THE TOILET SEAT.2.PROVIDE 18 INCHES FROM THE CENTERLINE OF THE WATER CLOSET TO THE ADJACENT WALL.3.TOILET AND URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE OPEN (WIDE) SIDE OF THE TOILET STALL, NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS.4.WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR SPACE 30 INCHES WIDE X 48 INCHES LONG IN FRONT OF THE URINAL. AT LEAST ONE URINAL WITH A RIM PROJECTING A MINIMUM OF 14 INCHES FROM THE WALL AND A MAXIMUM OF 17 INCHES ABOVE THE FLOOR SHALL BE INSTALLED.5.A CLEAR FLOOR SPACE 30 INCHES WIDE X 48 INCHES LONG SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. CLEAR FLOOR AREAS MAY NOT OVERLAP THE DOOR SWING.6.LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30 INCHES IN WIDTH WITH 8 INCHES MINIMUM DEPTH AT THE TOP. TOE CLEARANCE SHALL BE THE SAME WIDTH AND SHALL BE A MINIMUM OF 9 INCHES HIGH FROM THE FLOOR AND A MINIMUM OF 17 INCHES DEEP FROM THE FRONT OF THE LAVATORY. PROVIDE 60" CLEAR FROM EDGE OF LAVATORY TO WALL AT TOILET SIDE OF LAVATORY.7.HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.8.MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NOT MORE THAN 40 INCHES FROM THE FLOOR.9.LOCATE PAPER TOWEL DISPENSERS, SANITARY NAPKIN DISPENSERS, AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS NOT MORE THAN 40 INCHES FROM THE FLOOR.10.LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12 INCHES OF THE FRONT EDGE OF THE TOILET SEAT.MULTIPLE ACCOMMODATION TOILET FACILITIES1.A CLEAR SPACE MEASURED FROM THE FLOOR TO A HEIGHT OF 27 INCHES ABOVE THE FLOOR, WITHIN THE SANITARY FACILITY ROOM, OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESS THAN 60 INCHES, OR A CLEAR SPACE NOT LESS THAN 56 INCHES X 63 INCHES IN SIZE SHALL BE PROVIDED. DOORS OTHER THAN THE DOOR TO THE DISABLED TOILET COMPARTMENT, IN ANY POSITION, MAY ENCROACH INTO THIS SPACE BY NOT MORE THAN 12 INCHES.2.AN ACCESSIBLE INDIVIDUAL TOILET STALL SHALL PROVIDE AT LEAST 28 INCHES CLEAR SPACE FROM A FIXTURE OR 32 INCHES CLEAR SPACE FROM A WALL AT ONE SIDE OF THE WATER CLOSET. A 48 INCH LONG CLEAR SPACE IN FRONT OF THE WATER CLOSET SHALL BE PROVIDED IF THE COMPARTMENT HAS AN END OPENING DOOR (FACING THE WATER CLOSET). A 60 INCH LONG CLEAR SPACE SHALL BE PROVIDED IN A COMPARTMENT WHEN THE DOOR IS LOCATED AT THE SIDE. GRAB BARS SHALL NOT PROJECT MORE THAN 3 INCHES INTO THE CLEAR SPACES AS SPECIFIED ABOVE.3.WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC CLOSING DEVICE, AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WHEN LOCATED AT THE END AND 34 INCHES WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.4.EXCEPT FOR DOOR OPENING WIDTHS AND DOOR SWINGS, A CLEAR UNOBSTRUCTED ACCESS NOT LESS THAN 44 INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN 48 INCHES AS MEASURED AT RIGHT ANGLES TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.GRAB BARS 1.GRAB BARS SHALL BE LOCATED ON ONE SIDE AND THE BACK OF THE PHYSICALLY DISABLED TOILET STALL OR COMPARTMENT AND SHALL BE SECURELY ATTACHED 33 INCHES ABOVE AND PARALLEL TO THE FLOOR.2.GRAB BARS AT THE SIDE SHALL BE AT LEAST 42 INCHES LONG WITH THE FRONT END POSITIONED 54 INCHES FROM THE BACK OF THE STALL. GRAB BARS AT THE BACK SHALL NOT BE LESS THAN 36 INCHES LONG.3.PROVIDE A VERTICAL GRAB BAR AT SIDE WALL OF TOILET PER 18 INCHES MINIMUM IN LENGTH WITH THE BOTTOM OF TEH BAR LOCATED BETWEEN 39 INCNES AND 41 INCHES ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES FROM THE REAR WALL.4.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE 1-1/2 INCHES.5.A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. GRAB BAR EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH.6.GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.7.GRAB BARS SHALL BE DESIGNED TO SUPPORT A 250 POUND FORCE.TELEPHONES 1.PROVIDE A 30 INCH X 48 INCH CLEAR SPACE AT TELEPHONE. THE CLEAR SPACE MAY INCLUDE KNEE SPACE UNDER THE TELEPHONE.2.THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN 48 INCHES OF THE FLOOR IF FORWARD APPROACHED AND 54 INCHES IF SIDE APPROACHED.3.TELEPHONES MOUNTED DIAGONALLY IN A CORNER THAT REQUIRE WHEELCHAIR USERS TO REACH DIAGONALLY SHALL HAVE THE HIGHEST OPERABLE PART NO HIGHER THAN 54 INCHES ABOVE THE FLOOR.4.THE CORD FROM THE TELEPHONE TO THE HANDSET SHALL BE AT LEAST 29 INCHES LONG.5.IF BANKS OF PUBLIC TELEPHONES ARE PROVIDED, THEN A REASONABLE NUMBER, BUT ALWAYS AT LEAST ONE (1), IN A BUILDING OR FACILITY SHALL BE EQUIPPED WITH A VOLUME CONTROL.6.TELEPHONES SHALL HAVE PUSH-BUTTON CONTROLS WHERE SERVICE FOR SUCH EQUIPMENT IS AVAILABLE.ADDITIONAL REQUIREMENTS1.THE CENTER OF RECEPTACLE OUTLETS SHALL BE NOT LESS THAN 15 INCHES ABOVE THE FLOOR OR WORKING PLATFORM.2.THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE NOT LESS THAN 36 INCHES NOR MORE THAN 48 INCHES ABOVE THE FLOOR OR WORKING PLATFORM.3.THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48 INCHES ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK.4.THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595A.5.WHERE PERMANENT IDENTIFICATION IS PROVIDED OR WHERE SIGNAGE IS REQUIRED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH SECTIONS 1117B.5.6, 1117B.5.6.1, 1117B.5.6.2, AND 1117B.5.6.3. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATIONS SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE A DOOR.MIRRORMIRROR, SOAP DISPENSER12"ELECTRIC HAND DRYERSIDE WALL GRAB BAR, TOILET PAPER DISPENSER, SANITARY NAPKIN DISPOSALET.P.BACK WALL42" MAX.12"42"URINALIF MORE THAN 1 URINALURINALEWCMETAL CEILING HUNG BATHROOM PARTITION W/ROBE HOOKWALL MTD. URINAL SCREEN2'-0"58"DCBARECESSED PAPER TOWEL DISPENSER & WASTE RECEPTACLERECESSED NAPKIN/TAMPON VENDORSBABY CHANGING STATIONH.C.1'-5"24"RIMRIM12"4'-0"28"-34"<COAT HOOK ON BACK OF DOOR (STALL/ROOM)38"-40"HCFOUNTAIN <36"<A.F.F.33"-36"ACCESSIBLE SHOWER W/ FLEXIBLE HOSE SHOWER HEAD19"17"-3'-0"3'-0"33"-36"48"MAX.38"3'-0"18"24"DIVERTER VALVECONTROL VALVE2' - 10"2' - 10"2' - 10"2' - 10"4"4"4"4"2"2"2"2"3' - 0"3' - 0"3' - 0"3' - 0"3'-8" MAX3'-8" MAX3'-8" MAX3'-8" MAX3' - 4"3' - 4"3' - 4"3' - 4"MAXMAXMAXMAX3' - 4"3' - 4"3' - 4"3' - 4"3' - 4"3' - 4"3' - 4"3' - 4"1917TRANSITIONS24" PREFERRED24" PREFERRED24" PREFERRED24" PREFERRED18 MIN.18 MIN.18 MIN.18 MIN."X""X""X""X"22" MIN.22" MIN.22" MIN.22" MIN.24" MIN.24" MIN.24" MIN.24" MIN.24" MIN.24" MIN.24" MIN.24" MIN.12THRESHOLD5' - 0"5' - 0"5' - 0"5' - 0"WALL SIGNAGEF2' - 6"2' - 6"2' - 10"12" MAX48" MIN15" MAXGRAB BAR BLOCKINGBATHTUP SETION /ELEBVATION FOR GRAB BARSG33"-36"WALL BLOCK BEHIND33"-36"12" MIN9"2'-0"2'-11 3/4"6" MAX15" SEAT6'-3"2'-6"BATHTUB PLANSEAT15"-16"LOCATION OF CONTROLS4"4 1/4"18AGES 3 -4 (INCLUDE AGE 2)AGES 5 -8WATER CLOSET CLTOILET SEAT HEIGHTGRAB BAR HEIGHTDISPENSER HEIGHT12"12 -15"11 -12"12 -15"18 -20"20 -25"14"14 -17"NOTE: BOTH THE FEDERAL & STATE OF IL ACCESSIBILITY CODES DO NOT PROVIDE DIMENSIONS FOR AGE GROUPS BELOW 3 YEARS OLD. WE HAVE INCLUDED A SUMMARY FIXTURE MOUTNING DIMENSIONS CHART FOR REFERENCE.ADVISORY SPECS FOR WATER CLOSETS7" - 9"*DATE OF SIGNATURE: 1/28/22EXP. 12/31/23CARCTIEHRICEAEPPNo. 12100080TREGISREDANAINIDSTATE OFTEMGN CONSULTINGENGINEERS, INC.635 BUTTERFIELD ROADSUITE #310OAKBROOK TERRACE, IL 60181PHONE (630) 627-6078WWW.MGN.ENGINEERINGDESIGN FIRM #184001114-0002INFO@ALLENPEPA.COMTEL: (630) 578-1105215 FULTON ST., GENEVA, IL 60134PROJECT NO.DRAWN BYCHECKED BYSHEETSchematic Design:Design DevelopmentBidding:Permit:POST BID/PERMIT REVISIONS:ISSUE DATE:ALLEN+PEPA COPYRIGHTALLENPEPAA R C H I T E C T S2/18/2022 2:49:02 PMC:\Users\Amanda Kerner\Documents\21-014 Higher Ground Carmel_akernerK6S8R.rvtACCESSIBLITYSTANDARDSHIGHER GROUND CARMEL10216 N. MICHIGAN ROADCARMEL, INDIANA 46032FOR PERMIT 1/28/22G1-521-021AKEPOF 4751/28/2212/30/211/4" = 1'-0"1ADA REFERENCE INFORMATIONNo. Date Description