13-A1-5 ROOF PLAN
SECTION 2 1_ 4[57mm]3 1_ 2[89mm] R R R R R REINFORCED EVERGUARD MEMBRANE 2" 2" ALTERNATE INSTALLATION SEE NOTE #2 EVERGUARD PREMOLDED VENT BOOT TARGET MADE FROM EVERGUARD TPO MEMBRANE HEAT WELDED LAP TMDRILL-TEC PLATES & SCREWS 4 PER STACK EVERGUARD PREMOLDED VENT BOOT GAF WATER BLOCK EVERGUARD GUN GRADE SEALANTR VENT STACK STAINLESS STEEL CLAMP ROOF DECK/SUBSTRATE NOTE: 1. DO NOT CUT PREMOLDED BOOT. IT MUST BE PULLED OVER VENT PIPE. 2. IF THE PLATES AND FASTENERS INTRUDE INTO BOOT FLANGE AREA, THEN A TARGET MUST FIRST BE INSTALLED OVER PLATES AND FASTENERS BEFORE BOOT INSTALLATION. 3. APPLY EVERGUARD TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES ( REFER TO DETAIL THIS SHEET). 1 A3-1 2 A3-1 A D C 4 1 3 A3-1 EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL BELOWBELOWBELOWBELOW ICE & WATER SHIELD @ ROOF ICE & WATER SHIELD @ ROOF ICE & WATER SHIELD @ ROOF ICE & WATER SHIELD @ ROOF PERIMETER, MIN. 24" FROM PERIMETER, MIN. 24" FROM PERIMETER, MIN. 24" FROM PERIMETER, MIN. 24" FROM INSIDE FACE OF EXTERIOR INSIDE FACE OF EXTERIOR INSIDE FACE OF EXTERIOR INSIDE FACE OF EXTERIOR WALLWALLWALLWALL9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"36' - 9"36' - 9"36' - 9"36' - 9" 38' - 5"38' - 5"38' - 5"38' - 5" 3' - 0"3' - 0"3' - 0"3' - 0" 3' - 0"3' - 0"3' - 0"3' - 0"31' - 2 1/4"31' - 2 1/4"31' - 2 1/4"31' - 2 1/4"64' - 9 5/8"64' - 9 5/8"64' - 9 5/8"64' - 9 5/8" TYP.TYP.TYP.TYP. 2' - 0"2' - 0"2' - 0"2' - 0" DS DS DS DS DS DS DS DS DS DS, LOWER ROOF BELOW DS, LOWER ROOF BELOW DS DS OVERFLOWOVERFLOW OVERFLOW OVERFLOW DRAINDRAINDRAINDRAIN R.D.R.D. B5" / 12"5" / 12"5" / 12" 5" / 12" 1/4" PER FT. 1/4" PER FT.1/4" PER FT.ALUM. ALUM. ALUM. ALUM. COPINGCOPINGCOPINGCOPING ROOF VENTS, TYP. ROOF VENTS, TYP. ROOF VENTS, TYP. ROOF VENTS, TYP. (10)(10)(10)(10)34' - 0"34' - 0"34' - 0"34' - 0"34' - 0"34' - 0"34' - 0"34' - 0"2 3 2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"DS 7" / 12"7" / 12" 7" / 12"7" / 12"7" / 12"7" / 12" 7" / 12"7" / 12"1/4" PER FT.7" / 12"ICE & WATER SHIELD ON ICE & WATER SHIELD ON ICE & WATER SHIELD ON ICE & WATER SHIELD ON ENTIRE OVERFRAME ROOF ENTIRE OVERFRAME ROOF ENTIRE OVERFRAME ROOF ENTIRE OVERFRAME ROOF SECTIONSECTIONSECTIONSECTION 3 A3-4 2.2 2.3 2.5 2.62.4 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12"68' - 0"68' - 0"68' - 0"68' - 0"157' - 0"157' - 0"157' - 0"157' - 0" DS TO LOWER ROOF BELOW A3-4 5 4'4'4'4'----0"'0"'0"'0"'4'4'4'4'----0"0"0"0" SEE PLAN BELOWSEE PLAN BELOWSEE PLAN BELOWSEE PLAN BELOW SLOPE1" PER FOOTSLOPE1" PER FOOTSLOPE1" PER FOOTSLOPE1" PER FOOT SLOPE 1" PER FOOTSLOPE 1" PER FOOTSLOPE 1" PER FOOTSLOPE 1" PER FOOT RUST RESISTANTRUST RESISTANT RUST RESISTANT RUST RESISTANT BOLTBOLTBOLTBOLT SINGLE PLY SEALING SINGLE PLY SEALING SINGLE PLY SEALING SINGLE PLY SEALING MASTICMASTICMASTICMASTIC SLOPESLOPESLOPESLOPE 1" PER FOOT1" PER FOOT1" PER FOOT1" PER FOOT CUT HOLE THROUGH MEMBRANE AT CUT HOLE THROUGH MEMBRANE AT CUT HOLE THROUGH MEMBRANE AT CUT HOLE THROUGH MEMBRANE AT LEAST THE SAME DIA. AS ROOF LEAST THE SAME DIA. AS ROOF LEAST THE SAME DIA. AS ROOF LEAST THE SAME DIA. AS ROOF DRAIN PIPEDRAIN PIPEDRAIN PIPEDRAIN PIPE CLAMP RINGCLAMP RINGCLAMP RINGCLAMP RING TPO FILED MEMBRANETPO FILED MEMBRANE TPO FILED MEMBRANE TPO FILED MEMBRANE FULLY ADHERED INTO FULLY ADHERED INTO FULLY ADHERED INTO FULLY ADHERED INTO DRAIN BOWLDRAIN BOWLDRAIN BOWLDRAIN BOWL FULLY ADHERED TPO FULLY ADHERED TPO FULLY ADHERED TPO FULLY ADHERED TPO MEMBRANEMEMBRANEMEMBRANEMEMBRANE TPO MEMBRANE TPO MEMBRANE TPO MEMBRANE TPO MEMBRANE ADHESIVE ADHESIVE ADHESIVE ADHESIVE STEEL DECKSTEEL DECKSTEEL DECKSTEEL DECK RIGID INSULATIONRIGID INSULATIONRIGID INSULATIONRIGID INSULATION TAPERED TOWARD DRAINTAPERED TOWARD DRAINTAPERED TOWARD DRAINTAPERED TOWARD DRAIN TAPERED DRAINTAPERED DRAINTAPERED DRAINTAPERED DRAIN SINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULK FASTENER 12" O.C. MAXFASTENER 12" O.C. MAXFASTENER 12" O.C. MAXFASTENER 12" O.C. MAX TERMINATION BARTERMINATION BARTERMINATION BARTERMINATION BAR SINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULKSINGLE PLY LVOC CAULK FASTENER 12" O.C. MAXFASTENER 12" O.C. MAXFASTENER 12" O.C. MAXFASTENER 12" O.C. MAX SINGLE PLY SEALING MASTICSINGLE PLY SEALING MASTICSINGLE PLY SEALING MASTICSINGLE PLY SEALING MASTIC 3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING TPO MEMBRANE FULLY ADHERED TO WALLTPO MEMBRANE FULLY ADHERED TO WALL TPO MEMBRANE FULLY ADHERED TO WALL TPO MEMBRANE FULLY ADHERED TO WALL W/ APPROVED MEMBRANE ADHESIVEW/ APPROVED MEMBRANE ADHESIVEW/ APPROVED MEMBRANE ADHESIVEW/ APPROVED MEMBRANE ADHESIVE 3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING3" METAL COUNTERFLASHING TPO MEMBRANE FULLY ADHERED TO WALL W/ TPO MEMBRANE FULLY ADHERED TO WALL W/ TPO MEMBRANE FULLY ADHERED TO WALL W/ TPO MEMBRANE FULLY ADHERED TO WALL W/ APPROVED MEMBRANE ADHESIVEAPPROVED MEMBRANE ADHESIVEAPPROVED MEMBRANE ADHESIVEAPPROVED MEMBRANE ADHESIVE HOT AIR WELDED SPLICEHOT AIR WELDED SPLICEHOT AIR WELDED SPLICEHOT AIR WELDED SPLICE TPO MEMBRANETPO MEMBRANETPO MEMBRANETPO MEMBRANE MEMBRANE ADHESIVEMEMBRANE ADHESIVEMEMBRANE ADHESIVEMEMBRANE ADHESIVE APPROVED DECKAPPROVED DECKAPPROVED DECKAPPROVED DECK FASTENER 12" O.C. MAX. WITH FASTENER 12" O.C. MAX. WITH FASTENER 12" O.C. MAX. WITH FASTENER 12" O.C. MAX. WITH SEALANTSEALANTSEALANTSEALANT INSULATED METAL INSULATED METAL INSULATED METAL INSULATED METAL CURBCURBCURBCURB GASKETED FASTENER @ GASKETED FASTENER @ GASKETED FASTENER @ GASKETED FASTENER @ 12" O.C.12" O.C.12" O.C.12" O.C. P.T. WOOD NAILERP.T. WOOD NAILERP.T. WOOD NAILERP.T. WOOD NAILER TPO MEMBRANETPO MEMBRANETPO MEMBRANETPO MEMBRANE 1111----1/2" MIN. 1/2" MIN. 1/2" MIN. 1/2" MIN. CONTINUOUS WELDCONTINUOUS WELDCONTINUOUS WELDCONTINUOUS WELD TPO EDGE SEALANT, IF TPO EDGE SEALANT, IF TPO EDGE SEALANT, IF TPO EDGE SEALANT, IF REQ'DREQ'DREQ'DREQ'D STEEL DECKSTEEL DECKSTEEL DECKSTEEL DECK RTURTURTURTU 8" MIN8" MIN8" MIN8" MINTPO EDGE SEALANT, IF REQ'DTPO EDGE SEALANT, IF REQ'DTPO EDGE SEALANT, IF REQ'DTPO EDGE SEALANT, IF REQ'DSUBSTRATESUBSTRATESUBSTRATESUBSTRATE INSUL./COVER BOARDINSUL./COVER BOARDINSUL./COVER BOARDINSUL./COVER BOARD 3" - 8"3" - 8"3" - 8"3" - 8" INSUL. / COVER BOARDINSUL. / COVER BOARDINSUL. / COVER BOARDINSUL. / COVER BOARD ....6" SLOPESLOPESLOPESLOPE APPROVED FASTENER AND APPROVED FASTENER AND APPROVED FASTENER AND APPROVED FASTENER AND PLATEMIN 3/4" EMBEDMENT INTO PLATEMIN 3/4" EMBEDMENT INTO PLATEMIN 3/4" EMBEDMENT INTO PLATEMIN 3/4" EMBEDMENT INTO TOP FLUTETOP FLUTETOP FLUTETOP FLUTE CURB BASE FLASHING TERMINATION BAR W/ COUNTERFLASHING IN LAP FASTENING METHOD - STEEL DECK BILCO TYPE E ROOF SCUTTLE FRAME OPENING LENGTHFRAME OPENING LENGTHFRAME OPENING LENGTHFRAME OPENING LENGTH OVER ALLOVER ALLOVER ALLOVER ALL FRAME OPENING WIDTH FRAME OPENING WIDTH FRAME OPENING WIDTH FRAME OPENING WIDTHOVER ALLOVER ALLOVER ALLOVER ALLBILCLIP BILCLIP BILCLIP BILCLIP FLASHING SYSTEMFLASHING SYSTEMFLASHING SYSTEMFLASHING SYSTEM 3' - 0"3' - 0"3' - 0"3' - 0" 3' - 7"3' - 7"3' - 7"3' - 7" 3' - 0"3' - 0"3' - 0"3' - 0"3' - 7"3' - 7"3' - 7"3' - 7"1" [25] THICK FIBERGLASS1" [25] THICK FIBERGLASS1" [25] THICK FIBERGLASS1" [25] THICK FIBERGLASS COVER INSULATIONCOVER INSULATIONCOVER INSULATIONCOVER INSULATION COVERCOVERCOVERCOVER INSIDE & OUTSIDE HANDLES INSIDE & OUTSIDE HANDLES INSIDE & OUTSIDE HANDLES INSIDE & OUTSIDE HANDLES W/ PADLOCK HASPSW/ PADLOCK HASPSW/ PADLOCK HASPSW/ PADLOCK HASPS NEOPRENE GASKETNEOPRENE GASKETNEOPRENE GASKETNEOPRENE GASKETGASKETGASKETGASKETGASKET (ALL AROUND COVER)(ALL AROUND COVER)(ALL AROUND COVER)(ALL AROUND COVER) SLAM LATCHSLAM LATCHSLAM LATCHSLAM LATCH COVER COVER COVER COVER LINERLINERLINERLINER ARM GUIDEARM GUIDEARM GUIDEARM GUIDE BRACKETBRACKETBRACKETBRACKET RED VINYL GRIPRED VINYL GRIPRED VINYL GRIPRED VINYL GRIP HOLD OPEN ARMHOLD OPEN ARMHOLD OPEN ARMHOLD OPEN ARM LOCK STRIKE LOCK STRIKE LOCK STRIKE LOCK STRIKE & & & & PADLOCK HASPPADLOCK HASPPADLOCK HASPPADLOCK HASP PINTLE HINGEPINTLE HINGEPINTLE HINGEPINTLE HINGE LIFTING MECHANISM W/LIFTING MECHANISM W/LIFTING MECHANISM W/LIFTING MECHANISM W/ REINFORCED COMPOSITEREINFORCED COMPOSITEREINFORCED COMPOSITEREINFORCED COMPOSITE TUBES & COMPRESSION TUBES & COMPRESSION TUBES & COMPRESSION TUBES & COMPRESSION SPRINGSSPRINGSSPRINGSSPRINGS 1" [25] RIGID FIBERBOARD1" [25] RIGID FIBERBOARD1" [25] RIGID FIBERBOARD1" [25] RIGID FIBERBOARD INSULATIONINSULATIONINSULATIONINSULATION FRAME W/ CAPFLASHINGFRAME W/ CAPFLASHINGFRAME W/ CAPFLASHINGFRAME W/ CAPFLASHING (CORNERS FULL WELDED)(CORNERS FULL WELDED)(CORNERS FULL WELDED)(CORNERS FULL WELDED)7 3/8"7 3/8"7 3/8"7 3/8"1' - 0"1' - 0"1' - 0"1' - 0"3 1/2"3 1/2"3 1/2"3 1/2" 16' - 11 7/8" 21' - 10 1/4" JM TPO COVER TAPE 6" (SELFJM TPO COVER TAPE 6" (SELFJM TPO COVER TAPE 6" (SELFJM TPO COVER TAPE 6" (SELF---- ADHERING) PRIME METAL & ADHERING) PRIME METAL & ADHERING) PRIME METAL & ADHERING) PRIME METAL & MEMBRANE W/ JM TPO MEMBRANE W/ JM TPO MEMBRANE W/ JM TPO MEMBRANE W/ JM TPO MEMBRANE PRIMERMEMBRANE PRIMERMEMBRANE PRIMERMEMBRANE PRIMER PREFINISHED METAL EDGING PREFINISHED METAL EDGING PREFINISHED METAL EDGING PREFINISHED METAL EDGING SET IN SEALANT AND M.F.SET IN SEALANT AND M.F.SET IN SEALANT AND M.F.SET IN SEALANT AND M.F. TAPERED INSULATION ON TAPERED INSULATION ON TAPERED INSULATION ON TAPERED INSULATION ON 5/8" CDX PLYWD. 5/8" CDX PLYWD. 5/8" CDX PLYWD. 5/8" CDX PLYWD. SHEATHINGSHEATHINGSHEATHINGSHEATHING 2x6 P.T. KNEE WALL W/ 1/2" 2x6 P.T. KNEE WALL W/ 1/2" 2x6 P.T. KNEE WALL W/ 1/2" 2x6 P.T. KNEE WALL W/ 1/2" CDX PLYWD. EA. SIDECDX PLYWD. EA. SIDECDX PLYWD. EA. SIDECDX PLYWD. EA. SIDE PREFINISHED ALUM. PREFINISHED ALUM. PREFINISHED ALUM. PREFINISHED ALUM. COPING ON PREFORMED COPING ON PREFORMED COPING ON PREFORMED COPING ON PREFORMED CLEATSCLEATSCLEATSCLEATS JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO WATERWATERWATERWATER----BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE ADHESIVEADHESIVEADHESIVEADHESIVE JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO WATERWATERWATERWATER----BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE ADHESIVE. WRAP FULL HEIGHT ADHESIVE. WRAP FULL HEIGHT ADHESIVE. WRAP FULL HEIGHT ADHESIVE. WRAP FULL HEIGHT UP SIDE WALLS OF RTU DECK UP SIDE WALLS OF RTU DECK UP SIDE WALLS OF RTU DECK UP SIDE WALLS OF RTU DECK AND OVER COPINGAND OVER COPINGAND OVER COPINGAND OVER COPING WOOD TRUSSES, SEE WOOD TRUSSES, SEE WOOD TRUSSES, SEE WOOD TRUSSES, SEE STRUCT. FRAMING PLANSTRUCT. FRAMING PLANSTRUCT. FRAMING PLANSTRUCT. FRAMING PLAN TAPERED INSULATION ON TAPERED INSULATION ON TAPERED INSULATION ON TAPERED INSULATION ON 3/4" CDX PLYWD. 3/4" CDX PLYWD. 3/4" CDX PLYWD. 3/4" CDX PLYWD. SHEATHING @ RTU DECKSHEATHING @ RTU DECKSHEATHING @ RTU DECKSHEATHING @ RTU DECK 24 GA (MIN.) MTL. CLEAT 24 GA (MIN.) MTL. CLEAT 24 GA (MIN.) MTL. CLEAT 24 GA (MIN.) MTL. CLEAT SET IN SEALING MASTIC @ SET IN SEALING MASTIC @ SET IN SEALING MASTIC @ SET IN SEALING MASTIC @ ALL PENETRATIONSALL PENETRATIONSALL PENETRATIONSALL PENETRATIONS JM SINGLE PLY LVOC CAULKJM SINGLE PLY LVOC CAULKJM SINGLE PLY LVOC CAULKJM SINGLE PLY LVOC CAULKJM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 JM TPO FLEECEBACKED 115 FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO FULLY ADHERED IN JM TPO WATERWATERWATERWATER----BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE BASED MEMBRANE ADHESIVEADHESIVEADHESIVEADHESIVE 5/8" CDX PLYWD. NAILING 5/8" CDX PLYWD. NAILING 5/8" CDX PLYWD. NAILING 5/8" CDX PLYWD. NAILING BASE @ PERIMETERBASE @ PERIMETERBASE @ PERIMETERBASE @ PERIMETER ARCHITECTURAL ROOF ARCHITECTURAL ROOF ARCHITECTURAL ROOF ARCHITECTURAL ROOF SHINGLES ON MANUF. SHINGLES ON MANUF. SHINGLES ON MANUF. SHINGLES ON MANUF. APPROVED UNDERLAYMENT APPROVED UNDERLAYMENT APPROVED UNDERLAYMENT APPROVED UNDERLAYMENT ON 5/8" CDX PLYWD. ON 5/8" CDX PLYWD. ON 5/8" CDX PLYWD. ON 5/8" CDX PLYWD. SHEATHING, TYP.SHEATHING, TYP.SHEATHING, TYP.SHEATHING, TYP. CONT. SCREENED WALL CONT. SCREENED WALL CONT. SCREENED WALL CONT. SCREENED WALL VENT AROUND INSIDE VENT AROUND INSIDE VENT AROUND INSIDE VENT AROUND INSIDE PERIMETER OF RTU DECK PERIMETER OF RTU DECK PERIMETER OF RTU DECK PERIMETER OF RTU DECK FOR REQ'D. ATTIC FOR REQ'D. ATTIC FOR REQ'D. ATTIC FOR REQ'D. ATTIC VENTILATIONVENTILATIONVENTILATIONVENTILATION 2.6 * DATE OF SIGNATURE: 1/28/22 EXP. 12/31/23 CARCTIEHRICEAEPP No. 12100080 TR EGISRE DANAINI D STATE OF TE MGN CONSULTINGENGINEERS, INC.635 BUTTERFIELD ROADSUITE #310OAKBROOK TERRACE, IL 60181PHONE (630) 627-6078WWW.MGN.ENGINEERINGDESIGN FIRM #184001114-0002INFO@ALLENPEPA.COMTEL: (630) 578-1105215 FULTON ST., GENEVA, IL 60134PROJECT NO. DRAWN BY CHECKED BY SHEET Schematic Design: Design Development Bidding: Permit: POST BID/PERMIT REVISIONS: ISSUE DATE: ALLEN+PEPA COPYRIGHT ALLEN PEPAA R C H I T E C T S2/18/2022 2:48:23 PMC:\Users\Amanda Kerner\Documents\21-014 Higher Ground Carmel_akernerK6S8R.rvtROOF PLANHIGHER GROUND CARMEL10216 N. MICHIGAN ROADCARMEL, INDIANA 46032FOR PERMIT 1/28/22 A1-5 21-021 AK EP OF 4713 1/28/22 12/30/21 1/8" = 1'-0"1 ROOF PLAN 1 1/2" = 1'-0"6 ROOF DRAIN SECTION 1 1/2" = 1'-0"4 TYP. ROOF DETAILS NTS5 ROOF HATCH DETAIL 1" = 1'-0" 3 PREMOLDED VENT BOOT FLASHING NOTE: 1. SEE MEP DRAWINGS FOR ADDITIONAL PENETRATIONS THROUGH ROOF. ROOF VENT CALCULATIONS NET ATTIC AREANET ATTIC AREANET ATTIC AREANET ATTIC AREA: 10,936 SQ. FT. x 1/300 = 36.5 SF (5,256 SQ. IN.) REQUIRED VENTILATION: 10,936 SQ. FT. x 1/300 = 36.5 SF (5,256 SQ. IN.) REQUIRED VENTILATION: 10,936 SQ. FT. x 1/300 = 36.5 SF (5,256 SQ. IN.) REQUIRED VENTILATION: 10,936 SQ. FT. x 1/300 = 36.5 SF (5,256 SQ. IN.) REQUIRED VENTILATION 1/2 REQ'D @ SOFFIT = 18.25 SF1/2 REQ'D @ SOFFIT = 18.25 SF1/2 REQ'D @ SOFFIT = 18.25 SF1/2 REQ'D @ SOFFIT = 18.25 SF 1/2 REQ'D @ RIDGE OR HIGH ATTIC = 18.25 SF1/2 REQ'D @ RIDGE OR HIGH ATTIC = 18.25 SF1/2 REQ'D @ RIDGE OR HIGH ATTIC = 18.25 SF1/2 REQ'D @ RIDGE OR HIGH ATTIC = 18.25 SF SOFFIT VENTINGSOFFIT VENTINGSOFFIT VENTINGSOFFIT VENTING: : : :9 SQ. IN./FT NFVA * 436 FT. = 27.25 SF > 18.25 SF : OKAY9 SQ. IN./FT NFVA * 436 FT. = 27.25 SF > 18.25 SF : OKAY9 SQ. IN./FT NFVA * 436 FT. = 27.25 SF > 18.25 SF : OKAY9 SQ. IN./FT NFVA * 436 FT. = 27.25 SF > 18.25 SF : OKAY HIGH VENTINGHIGH VENTINGHIGH VENTINGHIGH VENTING::::TEN (10)TEN (10)TEN (10)TEN (10)----VX25 SERIES STATIC ROOF VENTS = 1 SF * 10 = 10 SFVX25 SERIES STATIC ROOF VENTS = 1 SF * 10 = 10 SFVX25 SERIES STATIC ROOF VENTS = 1 SF * 10 = 10 SFVX25 SERIES STATIC ROOF VENTS = 1 SF * 10 = 10 SF PERIMETER WALL VENT = 9 SQ. IN./FT NFVA * 162 = 10.13 SFPERIMETER WALL VENT = 9 SQ. IN./FT NFVA * 162 = 10.13 SFPERIMETER WALL VENT = 9 SQ. IN./FT NFVA * 162 = 10.13 SFPERIMETER WALL VENT = 9 SQ. IN./FT NFVA * 162 = 10.13 SF TOTAL NFVA = 20.13 SF > 18.25 SF : OKAYTOTAL NFVA = 20.13 SF > 18.25 SF : OKAYTOTAL NFVA = 20.13 SF > 18.25 SF : OKAYTOTAL NFVA = 20.13 SF > 18.25 SF : OKAY 1 1/2" = 1'-0"2 FLAT ROOF & COPING DETAIL SECTION No. Date Description 06/07/22