Loading...
HomeMy WebLinkAboutBLDG4-6-PARK-PLACE-C2-SITE A D A M S S T R E E T PHASE 4 0.337± Ac. LDI N G 2 716 A D A M S S T R E E T 7 U N I T B U I L D I N G BUIL D I N G 4 2-STO R Y M A S O N R Y OFFI C E B U I L D I N G 712 ADA M S S T R E E T 4,382 ± s q . f t. (FO O T P R I N T ) BUILDIN G 6 2-STORY M A S O N R Y OFFICE B U I L D I N G 708 ADAMS S T R E E T 5,255 ± sq.ft. (FOOTPR I N T ) NEW CT CABINET VERIFY TYPE, SIZE & LOCATION WIT H U T ILITY NEW CT C A B I N E T VERIF Y T Y P E , SIZE & L O C A T I O N W I T H U T I L ITY NEW GAS M E T ER VERIFY TYPE, SIZE & LO C A T ION WITH UTILITY NEW G A S M E T E R VERI F Y T Y P E , SIZE & LOC A T I O N W I T H UTILITY 33 L.F. NEW GAS SERVICE LATERAL BY UTILITY PROPOSED 141 L.F. - 5' CONCRETE SIDEWALK S E E D E T A I L O N S H E E T C 5 . 2 PROP O S E D 1 1 1 L . F . - 5 ' CONC R E T E SIDE WALK S E E DET A I L ON SHEET C5. 2 PROPOSED GAS VALVE AND CONNECTION VERIFY TYPE, SIZE AND LOCATION WITH UTILITY 32.67'2.00'34.67'2.00'32.67'45.00'31.46'2.00'37.08'2.00'31.46'45.00'10.7' 12.2 '27.3'31.46'44.0'31.46'2.00'49.75'2.00'4.00'31.46'44.00'31.46'PROPOSED 88 L.F. - 5'CONC. SIDEWALKEXISTING FIRE HYDRANT EXISTING WATER LINE EXISTING TRANSFORMER EXISTING PEDESTAL 49.75'4.00'28.0'15.0'CONCRE T E PATIOSEE DETAILS SHEET C6 . 1 16.0'15.0'CONC R E T E PATIOSEE DETAILSSHEET C6.1 41 L.F. NEW GAS SERVICE LATERAL BY UTILITY PROPOSED GAS VALVE AND CONNECTION VERIFY TYPE, SIZE AND LOCATION WITH UTILITY NEW 6'x15' CONCRETE BIKE PARKING SEE DETAIL 1/C6.1 NEW 12' - 6" PVC SANITARY LATERAL C.O. INV. = 840.27' SEE DETAIL ON SHEET C6.1 PROPOSED ADA SIDEWALK RAMP SEE DETAIL E604-SWCR-08 ON SHEET C5.2 PROVIDE 12' - (3)2" PVC CO N D U I T S TO CT CA BINET/METEREXISTING TRAN S FORMER PROVI DE 13' - (3)2" PVC COND U I TS TO CTCABINET/M E T E R EXISTING SANITARY EXISTING STORM WATER 27.1'20.9'21.7'PROPOSED CONCRETE AC PADS 4'x4' (TYP.) 41 L.F. OF NEW 1" DO M E S TIC SERVICE TO INSIDE SET METER, RPZ IN BUILDING. CONT R ACTO R TO VERIFY TYPE, SIZE & LOCA T I ON 50 L.F. O F N E W 1 " DOMESTIC SERVICE TO INSIDE SE T M E T E R, RPZ IN BUILDI N G . C O N T R A C T O R T O VERIFY TYPE, SIZE & L OCATIO N NEW 12' - 6" PVC SANITARY LATERAL C.O. INV. = 801.69' SEE DETAIL ON SHEET C6.1 PROPOSED ADA SIDEWALK RAMP SEE DETAIL E604-SWCR-08 ON SHEET C5.2 NEW ADA PARKING SIGN SEE DETAIL 6/C6.1 NEW ADA PARKING SIGN SEE DETAIL 6/C6.1 PROPOSED 21 L.F. - 5' CONC. SIDEWALK CONTRACTOR TO VERIFY TYPE AND SIZE OF EXISTING WATER CORP STOP WITH UTILITY. REMOVE EXISTING STUB AND CONNECT NEW SERVICE TO EXISTING CORP STOP CONTRACTOR TO VERIFY TYPE AND SIZE OF EXISTING WATER CORP STOP WITH UTILITY. REMOVE EXISTING STUB AND CONNECT NEW SERVICE TO EXISTING CORP STOP 1810-028 C2 PROPOSED SITE PLAN PARK PLACE CENTER BUILDINGSKEELER-WEBB ASSOCIATESLEGEND TAC SUBMITTAL12-19-2018SEE ARCH PLANS FOR INTERIOR LAYOUT, AND BUILDING DIMENSIONS NEW BUILDING DOMESTIC WATER CONNECTIONS TO EXISTING WATER MAIN WILL BE WET TAPPED PER CARMEL WATER SPECIFICATIONS. NEW WATER METERS AND RPZ TO BE INSIDE SET PER CARMEL WATER SPECIFICATIONS. SEE MECHANICAL DRAWINGS FOR DETAILS.TAC REVISIONS04-11-201911 1 1 EXTERIOR LIGHTING, PARKING LAYOUT AND SIGNAGE IS BASED ON PREVIOUS MASTER DEVELOPMENT PLAN FOR PARK PLACE CENTER HPR DECLARATION FROM 70-DP/ADLS & 71-99SP IN 1999. ALL AREAS OUTSIDE OF THE INDIVIDUAL BUILDING UNITS (I.E. BUILDING LINES) ARE CONSIDERED COMMON AREAS AND ARE ADMINISTERED BY THE COVENANTS, CONDITIONS, AND RESTRICTIONS OF PARK PLACE CENTER HPR. ALL FIRE HYDRANTS ARE EXISTING AND WERE INSTALLED AS PART OF THE MASTER DEVELOPMENT IN 1999. 1 1 1 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE 1 ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND BRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT ARE INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES AS NECESSARY OR AS REQUEST BY THE CITY TO ACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES, MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TO THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BE BORNE BY THE DEVELOPER DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY BUILDING FOOTPRINT REV.9-29-2021CONCRETE PATIOS ADDED10-13-2021BUILDING FOOTPRINT REV.01-12-2022DB KLAINCONSTRUCTION2159 Glebe StreetSuite 200Carmel, IN 46032(317) 846-9992CONTRACTOR TO CONTACT CENTERPOINT ENERGY FOR GAS SERVICE APPLICATION. 1-800-227-13763 TAC REVISIONS03-08-20223TAC REVISIONS02-22-202244 4 4 4 06/07/22