Loading...
HomeMy WebLinkAboutPacket for HO 06-27-22Powell Pool Variance Request 14436 Salem Drive East Carmel, IN 46033 Requested by: Kyle Powell Powell Pool Variances Docket No. PZ-2022-00094 V Docket No. PZ-2022-00095 V Project Introduction: We plan to install an in -ground pool which will be constructed by Pools of Fun. The liner pool will be 36' long X 16' wide. Concrete around the pool has been added to aid in maneuverability and enjoyment. An existing retaining wall will be demolished and re -constructed with new materials. Additionally, the angle of the retaining wall will be changed to avoid the in -place easement. Statement of Variance Request: Request variance of LIDO Section 5.02.7- Pool/decking setback must be 3 feet from any easement; 2 foot setback requested. When moving the existing retaining wall which currently encroaches upon the easement, this variance is requested so as not to change the symmetry of the concrete design. Request variance of LIDO Section 2.04- Maximum 35% lot cover allowed; 45.3% requested. We are requesting approval of a lot coverage increase because without it, we could not improve the backyard. The proposed plan is 576 SF of pool, with 1,069 SF of pool deck, making the requested lot coverage 45.3%. Statement of Support: We are seeking support of this project because it will improve our family's quality of life by helping us to enjoy quality time together. This forever home for our combined family was recently purchased in an established neighborhood and we are looking forward to making many memories here. This project will promote family bonding, time with friends, and physical and mental development for many years to come. From a community standpoint, we are hopeful that many neighbors will be able to enjoy the improvements as well. We are hopeful this proposal will be approved and look forward to making a positive impact on the Ashton community. Location Map and Reductions of Plans: • Aerial View • Location Map • Final Site Plan • Property Aerial View • Pool Design Details Findings of Fact Sheet: Included and completed Other Information: • HOA Approval • Pool Pump Specifications • Pool Filter Specifications Proof of Notice: Provided separately for the file, not part of the packet and includes: • Published Public Notice in the Current in Carmel • Mailed Public Notice to adjoining property Owners • Public Notice Sign r ' i Haze DeII�Pkwy �- r 7 Pk Hazel Dell � HazellDell�Pkw"` ` .i "-` vvy -Hazel Dell Pk Hai � a ro L] LS oSalem Dr E Mor— w 3r '�� r z o E a cn e, r i Bexley Dr Bexley Dr Bexley it IM _ ` J W a- c w W~W _ = m w g - a w le p w 1 z w a J Oz N Y D~ cUY N ��d J �a U w z a a W w Z a O F w 0 jj Ix {- m u7 J = (7 cFi c W W O i O C7 3 O Ja F O a O ,J a Z 7 O a W 0 a7 w w Ot O W a p d ZZdF W rr,� W} Z m W�W > IX. 0- o C7 ZQ m W (� Jj S !A W fp > U (A W (n = S VJ m ®a o -� ®lo e ° ] U 0 ..=9-.E .A-.9 paw o O 0 Fm ® A L �a a 4,L o� a 0 ,'k Y y U IZ Ly a NNO I b m I J Q W I Gov U W. _ -�O o' _ atu- _ �W U 00 a V _ wN Q J z„ a� x O m a� J W ^O CL U &UU }t}t0 O QOO U UU a �QO a K Y� O a W z J {9 K �. - JID �+ Ilk ►� _ .►1 1� K r _Sitr. g� r 0: ro 8wILI z 0: Z FQ (Dgg LU Z 0 Z 2 0 ILI :-r . 2 z 0 C, 111 0 0 W aou)�2, Ual OZ � LLJ Z O LU Q 03 :Z) * LL LU 1: ov)IX LL 04 C*4 : U, Lu Lu 0 ox� 4 Lu% WOO UIC M080 It =! Z �0:)Po 01. a � :, 0 0 IND 0 olp 6 U. m 0 C) Q00 a. I a U LL 0 90 3: mu- -W,, IV to r� 6 0 Lu w w w z z w LL U) 0 (a P CL U) 0 LO 0 It IL U) ci 'T co U. Iz,LL U'w m H0 N o. uj i C-4J 0 0 CL EDGE OF VATER The subject property is not located in a special Flood hazard area as :established by the FEDERAL EMERGENCY MANAGEMENT AGENCY -NATIONAL FLOOD INSURANCE PROGRAM, as per flood insurance rate rap 180081-0004c. NO TEI Sanitory and water laterals were unable to to locoted In the field- Shown herewith, the laterol connections nay differ In the field. LEGEND SCALE- 1'=30' B.C.= BACK OF CURB T.C.= TOP OF CASTING -W- = WATER LINE DRAINAGE FLOW= PL EI T PLAN - --- -- - - - - LOT #1'06 in ASHTOV, SECTION L a subdivision in Hamilton County, Indiana as per pia t thereof, recorded ,as Instrument #9100973, in Plat Cabinet #I, Slide #151 in the Office of the Recorder of Hamilton County, Indiana. DATED: MAY 13, 19.92 R _ �aN WEIHE ENGINEERS INC. z pRePa2Eb )=02 92= 63/0 —M q Lam- oaAWN Br ALL AN K INEINE, P E.1- 3 A' )�'(%tiL Hc��v �L.� a=r)�. C�l-2. 10505 N. COLLEGE AVENUE cNE `KEo e. INOIANAPOLIS, INDIANA 46280 PRESIDENT /. c•O. 317-846-6611 LoT$'/,0,6,,,:F4jr0A/,SEC. S, f7AMILrOAl CO-_ ONES-lp CViIEMGWEER3 . osonVE.oAs 1. ooufwEas - DEVELOPMENT STANDARDS VARIANCE CARMEL ADVISORY BOARD OF ZONING APPEALS (Petitioner to fill out 1-3 + first two blanks) Docket No.: I 22 Petitioner: �21 �- 2. 3. The approval of this variance will not be injurious to the public health, safety, morals and general welfare of the community because: T' The` s-'e aYid'value of the area adja`cent'to the adverse manner because: will not be affected in a substantially i 1; ie�W"A 1A W"f- q E OF.� oft the terms of the bnfed Development to the property will result in practical difficulties in the use of the pr..because:1 DECISION CISION IT IS THEREFORE the decision of the Cannel Board of Zoning Appeals that Development Standards Variance Docket No. _ - is granted, subject to any conditions stated in the minutes of this Board, which are incorporated herein by reference and made a part hereof. Adopted this day of , 20 HEARING OFFICER, Carmel Board of Zoning Appeals SECRETARY, Carmel Board of Zoning Appeals Conditions of approval of the Board, if any, are listed on the Letter of Grant. Page 7 of 11 File: Hearing Officer Development Standards Variance Handout 2022 Revised: 01/03/2022 Ashton Homeowners Association, Inc. Date: June 9, 2022 Kyle C. Powell Account No: 102001061 14436 Salem Dr. East Carmel, IN 46033 Re: Pool Approval Letter Dear Kyle C. Powell: Congratulations! Your architectural request to build an inground pool has been approved as submitted. The purpose of the review process is to promote and ensure a high level of quality, harmony and conformity throughout the neighborhood by using the rules set forth in the Covenants, Conditions and Restrictions (CCR) found in the Declaration. The Board appreciates your cooperation and due diligence in following this architectural review process. If you have any questions or comments please feel free to contact me at (317) 558-5361 or acarroll@ekirkpatrick.com. On behalf of Ashton Homeowners Association, Inc., Kirkpatrick Management Company, Agent Amanda Carroll Community Association Manager F ff ff ff AV VS RoPro 1.85 HP VARIABLE -SPEED PUMP -c::�J_4andys DUAL VOLTAGE. IDENTICAL PERFORMANCE. There's no need to sacrifice your pump's power. The ideal replacement for high energy -consuming single -speed pumps up to 1.5 HP, the 115v/230v dual voltage VS FloPro' 1.85 is the only variable -speed pump on the market that offers the same performance at both voltages. • 115v/230v Dual Voltage With the ability to provide the same head pressure and flow rates at both 115v and 230v, the VS FloPro 1.85 eliminates the need for expensive main power rewiring without compromising performance. • Add iOPUMP01 for Instant Automation Two auxiliary relays can be used to control other pool equipment, such as booster pumps and salt chlorinators, for easier installation and operation. No need for additional timeclocks! lAquaLink CONTROL A& sees,` • Lower Electricity Costs Save over $850' per year in energy costs! The variable -speed motor altows for dramatic energy savings and quieter operation. • Our Quietest Variable -Speed Pump Over 40% quieter than other Jandy variable - speed pumps, the VS FloPro 1.85 HP features proprietary sound dampening motor technology allowing it to operate with noticeably less noise. • Choose Your Own Controller Designed to work with the following Jandy� control systems for complete programmability and customization [controller sold separately): > Jandy AquaLinkm Automation Systems > i0PUMP01 with iAquaLink'App Control > JEP-R Controller • Additional Features > Adjustable base for seamless direct replacement of a variety of other pumps in the aftermarket > Zero Clearance TEFC Motor for cool, quiet operation in tight spaces > 2" unions included or utilize 2" internal threads > Easy Controller Setup auto detects connection to an automation system or a traditional controller, eliminating the need to adjust settings manually > RS485 Quick Connect Port for faster installation and maintenance > Dry Contact Relay Control > Tool -free lid for easy debris removal > Ergonomic easy -transport handle Jandy.com 1 1.800.822.7933 Base Fits Dimension Dimension Hayward" Super Pump• No Base Pentair•SuperFlo• 73/4" 123/4' Sta-Rite" SuperMax• Small Base Hayward Super 11' 8 7/8" 13 7/8" Jandy PlusHP and MaxHP Pumps Small Base Pentair WhisperFlo• 9 1/8" 14 1/8" w/Spacers Sta-Rite Dyna-Glas" Sta-Rite Max-E-Pro" Small Base Sta-RiteDura-Glasm 103/4" 153/4" +Large Base Sta-Rite Dura-Glas II Sta-Rite Max-E-Glass L- 6 VII -1 Bolt Nola, Center to Center 1tn• Front Edge of Union to Center of Bolt Holes Immum Max Union Rec. Carton Overall Model No. THP WEF' Voltage Watts Amps Size Pipe Size° Weight Length VSFHP185DV2A 1.85 8.5 230 VAC 1,700W 7.5 2"• 2- 1 1/2" - 2 1/2" 53 tbs. 24 1/2' ��� 115 VAC 1,800W 15.5 ■IFIrs7:JSI\. vsFRPtesovtA P.rmrra.au Car... so eo 3450 RPM c )e 3000 RPM E 2750 RPM so s ao 2400 RPM E a� 1730 RPM 20 )zoo_ RPM o 600 RPM o m w .o w w m eo so ,00 „• ,Ts tx r.o Raw R.t., Gs0— Per MNate (GPM) 0 NSF ��a ..�.,w... Interteir FSHMN f—I A—eml dMIMMOMIMM CV/CL SERIES Cartridge Filters r ff ff AV AV CV-CL SEriES I CARTRIDGE FILTER Jandy Pro Series CV & CL Cartridge Filters The CV and CL Cartridge Filters set the benchmark in cartridge filtration. Loaded with user-friendly features, Jandy Pro Series Cartridge Filters optimize surface area and help provide clean, sparkling water. They are constructed of durable and corrosion - resistant materials for maximum durability and are available in 340, 460 and 580 square foot models. The included Sweep Elbow and unions allow the filter to easily connect to nearly all Jandy Pro Series products 2" x 21/2" Universal Unions and easy grip handles make installation and cleaning easy Extra large 2" drain port allows for easy cleaning Unique pressure gauge features clean/dirty indicator that can be customized, making it easy to assess filter cartridge condition CV/CL SERIES c Cartridge Filters DIMENSIONS CL Filter £V Filter 11119:11.126INZ CV/CL Filter Head Loss Curves 28 26 24 22 20 18 Design 16 Head 14 Loss (It head) 12 10 8 6 4 2 0 12 10 8 Design Pressure 6 Drop tPe9 4 2 - CL340 CV340 CL460 CV460 0 CL580CV580 0 30 60 90 120 150 Flow Rate (gpm) • � 1 Specifications and Dimensions, CL & CV Series Fitters Model Number CL340 CL460 CL580 CV340 CV460 CV580 Filter Area Design Flow Rate 340 ft' .37 gpm/fl' 460 it' .33 gpm/ft' 580 fF .26 gpm/ft' 340 W .37 gpm/ft' 460 It' .33 gpm/ft' 580 fit .26 gpm/ft' Maximum Flow 127 gpm 150 gpm 150 gpm 127 gpm 150 gpm 150 gpm Six Hour Capacity Eight Hour Capacity 45,720 gallons 60.960 gallons 54.000 gallons 72,000 gallons 54,000 gallons 72,000 gallons 45.720 gallons 60,960 gallons 54.000 gallons 72.000 gallons 54.000 gallons 72.000 gallons Maximum Working Pressure 50 psi 50 psi 50 psi 50 psi 50 psi 50 psi Cartridges Required 4185ftt each) 41115ft' each) 41145ft7 each) 4 (85ft' each) 4(1151it' each) 41145ft' each) Shipping Weight 93 tbs. 95 tbs. 101 lbs. 106 lbs. 106 lbs. 112 tbs. Height)"A"I Footprint Distance Between Inlet and Outlet 41inches 25" dia. circle 8" 41inches 25" dia. circle 8" 47inches 25" dia. circle 8" 41inches 25" dia. circle Not Applicable 41inches 25" dia. circle Not Applicable 47inches 25" dia. circle Not Applicable Zodiac Pool Systems, Inc. Zodiac Pool Systems Canada, Inc. 2620 Commerce Way, Vista, CA 92081 2115 South Service Road West, Unit #3, Oakville, ON L6L 5W2 1.800.822.7933 1 www.ZodiacPoolSystems.com 1.888.647.4004 1 www.ZodiacPoolSystems.ca ZODIAC® FAMILY OF BRANDS I Heritage of Excellence 02016 Zodiac Pool Systems, Inc. ZODIACO is a reg stered trademark of Zodiac International. S.A.S.U., used under license. SL6257 Rev B 0316