HomeMy WebLinkAboutIN0128 (1637) Carmel Dr Modification Design Drawings 02.15.2022.pdfSTRUCTURE INFORMATION:
CODE COMPLIANCE:
STRUCTURE DRAWINGS:
STRUCTURE HEIGHT:
STRUCTURE LOCATION:
LAT.:
LONG.:
REFERENCED ANALYSIS:
ANALYSIS DATE:
WIND SPEEDS:
ICE THICKNESS:
STRUCTURE CLASS:
EXPOSURE CATEGORY:
TOPO CATEGORY:
GOVERNING CODES:
COUNTY:
CLIENT #: IN0128
FA #: 10023984
CARMEL DR
STREET ADDRESS:
CITY, STATE ZIP: CARMEL, IN 46032
650 E CARMEL DR.
LAWSON/ELSER/PROJ. #: 1345
53'-0" ROOFTOP
39° 57' 44.00"
-86° 6' 55.09"
HAMILTON
GPD/PROJ. #: 2022723.16.1637.03
2/14/2022
MOUNT TYPE: ALPHA, BETA, & GAMMA SECTOR
FRAMES
QUALIFIED ENGINEERING SERVICES ARE AVAILABLE
FROM GPD TO ASSIST CONTRACTORS IN CLASS IV
RIGGING PLAN REVIEWS. FOR REQUESTING QUALIFIED
ENGINEERING SERVICES PLEASE CONTACT GPD AT
GPDMODS@GPDGROUP.COM.
SHEET INDEX:
T-01: TITLE SHEET
MI-01: MODIFICATION INSPECTION CHECKLIST
PROJECT CONTACTS:
USID #: 1637
N-01: PROJECT NOTES
TIA-222-G & 2014 INDIANA BUILDING CODE
115 MPH 3 SECOND GUST (ULTIMATE)
89 MPH 3 SECOND GUST (NOMINAL)
40 MPH 3 SECOND GUST (W/ ICE)
1"
II
C
1
N-02: ADDITIONAL PROJECT NOTES
S-01: ROOFTOP PLAN & MODIFICATION SCHEDULE
S-02: MODIFICATION DETAILS & SECTIONS
S-03: ADDITIONAL DETAILS & SECTIONS
S-04: ADDITIONAL DETAILS & SECTIONS
S-05: ADDITIONAL DETAILS & SECTIONS
S-06: ADDITIONAL DETAILS & SECTIONS
S-07: ADDITIONAL DETAILS & SECTIONS
S-08: ADDITIONAL DETAILS & SECTIONS
S-09: ADDITIONAL DETAILS & SECTIONS
2/15/22
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
MI-01
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
MODIFICATION INSPECTION
CHECKLIST
2/15/2022
-
-
-
MODIFICATION INSPECTION CHECKLIST
REQUIRED REPORT ITEM BRIEF DESCRIPTION
PRE-CONSTRUCTION
X MI CHECKLIST DRAWING THIS CHECKLIST SERVES AS A GUIDELINE FOR THE REQUIRED CONSTRUCTION DOCUMENTS AND INSPECTIONS
FOR THIS MODIFICATION
X EOR APPROVED SHOP DRAWINGS PRIOR TO FABRICATION, THE CONTRACTOR SHALL PROVIDE DETAILED ASSEMBLY DRAWINGS AND/OR SHOP
DRAWINGS TO THE EOR FOR APPROVAL.
X FABRICATION INSPECTION
A LETTER FROM THE FABRICATOR STATING THAT ALL FABRICATION (I.E. DRILLING, CUTTING, WELDING,
SHEARING, MILLING, GALVANIZING, ETC) HAS BEEN DONE ACCORDING TO INDUSTRY STANDARDS AND ALL
APPLICABLE ANSI/ASTM STANDARDS.
NA FABRICATOR CERTIFIED WELD INSPECTION A CWI SHALL INSPECT ALL FABRICATION WELDS IN ACCORDANCE WITH AWS D1.1 AND A REPORT DETAILING
THE RESULTS SHALL BE PROVIDED TO THE MI INSPECTOR FOR INCLUSION IN THE MI REPORT.
X MATERIAL TEST REPORTS (MTR) MATERIAL TEST REPORTS SHALL BE PROVIDED FOR ALL MATERIAL USED. MTR'S SHALL BE PROVIDED TO THE
MI INSPECTOR FOR INCLUSION IN THE MI REPORT.
NA FABRICATOR NDE INSPECTION REPORT
CRITICAL SHOP WELDS THAT REQUIRE ADDITIONAL TESTING ARE NOTED WITHIN THE MODIFICATION
DRAWINGS. A CERTIFIED NDT INSPECTOR SHALL PERFORM NON-DESTRUCTIVE EXAMINATION ON ALL PJP, CJP,
AND FILLET WELDS >5/16” IN ACCORDANCE WITH AWS D1.1 AND A REPORT DETAILING THE RESULTS SHALL BE
PROVIDED TO THE MI INSPECTOR FOR INCLUSION IN THE MI REPORT.
NA NDE OF MONOPOLE BASE PLATE A NDE OF THE POLE TO BASE PLATE CONNECTION IS REQUIRED AND A WRITTEN REPORT SHALL BE PROVIDED
TO THE MI INSPECTOR FOR INCLUSION IN THE MI REPORT.
X PACKING SLIPS PACKING/SHIPPING LIST FOR ALL MATERIAL USED DURING CONSTRUCTION OF THE MODIFICATION SHALL BE
PROVIDED.
DURING CONSTRUCTION
2/15/22 JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
N-01
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
PROJECT NOTES
2/15/2022
-
-
-
GENERAL NOTES
1. THIS DESIGN IS IN ACCORDANCE WITH THE GOVERNING PROVISIONS OF ALL LOCALLY ADOPTED BUILDING
CODES. MATERIALS, FABRICATION, INSTALLATION, AND ALL OTHER SERVICES PROVIDED BY THE
CONTRACTOR SHALL CONFORM TO THE ABOVE MENTIONED CODES AND THE CONTRACT SPECIFICATIONS.
2. THIS DESIGN ASSUMES THE EXISTING STRUCTURE HAS BEEN WELL MAINTAINED, IS IN GOOD CONDITION, AND
IS WITHOUT DEFECT. BENT MEMBERS, CORRODED MEMBERS, LOOSE BOLTS, CRACKED WELDS AND OTHER
MEMBER DEFECTS HAVE NOT BEEN CONSIDERED. THIS DESIGN IS BEING PROVIDED WITHOUT THE BENEFIT OF
A CONDITION ASSESSMENT BY GPD.
3. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING; ANY PROBLEMS WITH ACCESS, INTERFERENCE,
ETC. SHALL BE RESOLVED PRIOR TO MOBILIZATION. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND
NOTE ANY EXISTING CONDITIONS THAT ARE NOT REPRESENTED ON THESE DRAWINGS OR THAT INTERFERE
WITH THE CONTINUOUS INSTALLATION OF THE MODIFICATIONS. CONTRACTOR SHALL NOTE ALL ATTACHMENT
POINTS, ANTENNAS, MOUNTS, COAX, LIGHTING, CLIMBING SUPPORTS, STEP BOLTS, PORT HOLES, AND ANY
OTHER APPURTENANCES IN THE REGION OF THE MODIFICATIONS. GPD SHALL BE CONTACTED IMMEDIATELY
TO EVALUATE THE SIGNIFICANCE OF ANY DEVIATION PRIOR TO ORDERING MATERIAL.
4. ALL MATERIAL SPECIFIED FOR THIS PROJECT MUST BE NEW AND FREE OF ANY DEFECTS. ANY MATERIAL
SUBSTITUTIONS, INCLUDING BUT NOT LIMITED TO ALTERED SIZES AND/OR STRENGTHS, MUST BE REVIEWED
BY THE OWNER AND ENGINEER. CONTRACTOR SHALL PROVIDE DOCUMENTATION TO ENGINEER FOR
DETERMINING IF SUBSTITUTE IS SUITABLE FOR USE AND MEETS THE ORIGINAL DESIGN CRITERIA.
DIFFERENCES FROM THE ORIGINAL DESIGN, INCLUDING MAINTENANCE, REPAIR AND REPLACEMENT, SHALL BE
NOTED. ESTIMATES OF COSTS/CREDITS ASSOCIATED WITH THE SUBSTITUTION (INCLUDING RE-DESIGN COSTS
AND COSTS TO SUB-CONTRACTORS) SHALL BE PROVIDED TO THE ENGINEER.
5. CONTRACTOR IS RESPONSIBLE FOR ENGAGING A MODIFICATION INSPECTOR AT THE TIME OF AWARD TO
COORDINATE AN INSPECTION SCHEDULE AND ENSURE PROPER DOCUMENTATION IS RETAINED THROUGHOUT
THE PROJECT. REFER TO SHEET MI-01 FOR MODIFICATION INSPECTION CHECKLIST.
6. SPECIAL INSPECTIONS: UNLESS OTHERWISE SPECIFIED WITHIN THE PLANS OR REQUIRED BY THE BUILDING
OFFICIAL, SPECIAL INSPECTIONS AND TESTS ARE NOT REQUIRED FOR GROUP U OCCUPANCIES, BUT NOT
2/15/22 JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
N-02
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL
PROJECT NOTES
2/15/2022
-
-
-
RADIO FREQENCY (RF) TRANSPARENT FIBER
REINFORCING POLYMER (FRP) NOTES
1. ALL FRP SHEET AND STRUCTURAL COMPONENTS USED IN VISION SCREENS SHALL BE
TRANSPARENT TO ELECTRO-MAGNETIC RADIATION AT THE FREQUENCIES REQUIRED BY THE
OWNER. THE CONTRACTOR SHALL VERIFY RF TRANSPARENCY AT THE REQUIRED FREQUENCIES
WITH THE FRP MANUFACTURER PRIOR TO FABRICATION OF THE VISION SCREENS.
2. THE MATERIAL SPECIFIED SHALL BE FURNISHED BY A REPUTABLE AND QUALIFIED MANUFACTURER
OF DEMONSTRATED ABILITY WHO HAS ROUTINELY ENGAGED IN THE MANUFACTURE OF FIBER
REINFORCED POLYMER COMPOSITES.
3. SUBSTITUTION OF ANY COMPONENT OR MODIFICATION OF SYSTEM WILL BE MADE ONLY AFTER
APPROVAL BY THE ENGINEER.
4. ALL SYSTEMS, SUB-SYSTEMS, AND STRUCTURES WILL BE FACTORY-FABRICATED AND ASSEMBLED
TO THE BEST PRACTICAL SIZES FOR TRANSPORTATION.
5. ALL MATERIAL AND EQUIPMENT NECESSARY FOR THE FABRICATION AND INSTALLATION OF THE
FRP PRODUCTS WILL BE STORED BEFORE, DURING, AND AFTER SHIPMENT IN A MANNER TO
PREVENT CRACKING, TWISTING, BENDING BREAKING, CHIPPING OR DAMAGED OF ANY KIND TO THE
MATERIAL OR EQUIPMENT, INCLUDING ULTRAVIOLET DAMAGE.
6. MATERIAL USED IN THE MANUFACTURE OF FRP PRODUCTS SHALL BE OF THE QUALITY AND FREE
FROM DEFECTS AND IMPERFECTION THAT MAY AFFECT THE PERFORMANCE OF THE FINISHED
PRODUCT.
7. ALL FRP PRODUCTS WILL BE MANUFACTURED USING THE PULTRUSION MANUFACTURING PROCESS
WITH EITHER THERMOSET POLYESTER PR THERMOSET VINYLESTER RESINS INCLUDING
FLAMMABILITY AND ULTRAVIOLET (UV) INHIBITOR ADDITIVES. A SYNTHETIC SURFACE VEIL SHALL
BE THE OUTERMOST LAYER OF THE EXTERIOR SURFACE. ALL EXPOSED SURFACES SHALL BE
SMOOTH AND TRUE TO FORM. AFTER FABRICATION, ALL CUT ENDS, HOLES, AND ABRASIONS OF
FRP COMPOSITE PRODUCTS WILL BE SEALED WITH A COMPATIBLE RESIN COATING CONTAINING A
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-01
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ROOFTOP PLAN &
MODIFICATION SCHEDULE
2/15/2022
-
-
-
2/15/22
MODIFICATION SCHEDULE
SECTOR MEMBER
TYPE ELEVATION EXISTING MEMBER NEW MEMBER
REFERENCE
DETAIL/SHEET NOTES
ALPHA
SCREEN WALL
53'-0"±
STEEL SCREEN WALL FRP SCREEN WALL
PANEL
1/S-02
REPLACE STEEL SCREEN WALL WITH NEW
FRP MATERIAL.
BRACING - L4x4x3/8 FRP INSTALL NEW FRP BRACING BETWEEN
COLUMNS AND KICKERS.
TOP CHORD HSS2-1/2x2-1/2x1/4 2-1/2"x2-1/2"x1/4"
FRP TUBE
REPLACE EXISTING STEEL TOP CHORD WITH
NEW FRP MEMBERS.
COLUMNS VARIES (3) 4"x4"x1/4 FRP
TUBE
REPLACE EXISTING STEEL COLUMNS WITH
NEW FRP MEMBERS.
MOUNTING
FRAME - L4x4x1/4
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-02
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
MODIFICATION DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-02 SCALE: 3/16" = 1'-0"
1 ALPHA SECTOR
S-02 SCALE: 3/16" = 1'-0"
A SECTION
S-02 SCALE: 3/16" = 1'-0"
B SECTION
3'-0" 6'-3"±
(F.V.)
6'-3"±
(F.V.)
6'-3"±
(F.V.)
3'-0"
EQ.
(TYP.)
EQ.
(TYP.)
25'-3"±
(F.V.)
A
S-02
B
S-02
25'-3"±
(F.V.) F.V.
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-03
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-03 SCALE: 3/8" = 1'-0"
C SECTION
S-03 SCALE: 3/8" = 1'-0"
D SECTION
S-03 SCALE: 3/16" = 1'-0"
2 BETA SECTOR
9'-6"
(F.V.)
1'-8"
(F.V.)
2'-0"
(F.V.)
2'-8"
(F.V.)
2'-8"
(F.V.)
6"
(F.V.)
11"
1'-2"
(F.V.)
2'-7"
(F.V.)
4'-4"
(F.V.)
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-04
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-04 SCALE: 3/8" = 1'-0"
E SECTION
S-04 SCALE: 3/8" = 1'-0"
F SECTION
S-04 SCALE: 3/16" = 1'-0"
3 GAMMA SECTOR
1'-5"
TYP.
G*
TYP.
6"
1'-2"
(F.V.)
2'-7"
(F.V.)
5'-9"
(F.V.)
4'-8"
G* (F.V.)
G*
TYP.
4'-8"
(F.V.)
3'-0" 6'-3"±
(F.V.)
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-05
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-05 SCALE: 3/16" = 1'-0"
G SECTION
S-05 SCALE: 3/16" = 1'-0"
H SECTION
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
K
S-06
25'-2"
1'-8"
(F.V.)
2'-0"
(F.V.)
2'-8"
(F.V.)
2'-8"
(F.V.)
6"
(F.V.)
6'-2"±
(F.V.)
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-06
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-06 SCALE: 3/8" = 1'-0"
J SECTION
S-06 SCALE: 3/8" = 1'-0"
K SECTION
9'-6"
(F.V.)
1'-8"
(F.V.)
2'-0"
(F.V.)
2'-8"
(F.V.)
2'-8"
(F.V.)
6"
(F.V.)
11"
1'-2"
(F.V.)
2'-7"
(F.V.)
4'-4"
(F.V.)
5'-9"
(F.V.)
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-07
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-07 SCALE: 1-1/2" = 1'-0"
6 END CONNECTION
S-07 SCALE: 1-1/2" = 1'-0"
M SECTION
S-07 SCALE: 1-1/2" = 1'-0"
N SECTION
S-07 SCALE: 1-1/2" = 1'-0"
7 COLUMN CONNECTION S-07 SCALE: 1-1/2" = 1'-0"
P SECTION
M
S-07
P
S-07
2"
G*
G*
G*
1 1/4" 1 1/4"
G*
2" 2
G*
TYP.
NEW 4"x4"x1/4"
FRP TUBE
KICKER
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-08
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-08 SCALE: 1-1/2" = 1'-0"
8 KICKER TOP CONNECTION S-08 SCALE: 1-1/2" = 1'-0"
Q SECTION
S-08 SCALE: 1-1/2" = 1'-0"
9 HORIZONTAL CONNECTION
S-08 SCALE: 1-1/2" = 1'-0"
10 END CONNECTION
S-08 SCALE: 1-1/2" = 1'-0"
R SECTION
S-08 SCALE: 1-1/2" = 1'-0"
S SECTION
1 1/4" 1 1/4"
G*
2"
Q
S-08
G*
EQ. EQ.
1 1/4" 1 1/4"
G*
EQ. EQ.
G*
G*
TYP.
G*
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
S-09
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
ADDITIONAL DETAILS
& SECTIONS
2/15/2022
-
-
-
2/15/22
S-09 SCALE: 1-1/2" = 1'-0"
11 CHORD CONNECTION S-09 SCALE: 1-1/2" = 1'-0"
12 END CONNECTION
S-09 SCALE: 1-1/2" = 1'-0"
13 CORNER CONNECTION
S-09 SCALE: 1-1/2" = 1'-0"
14 HORIZONTAL CONNECTION
S-09 SCALE: 1-1/2" = 1'-0"
U SECTION
1 1/4" 1 1/4"
G*
EQ. EQ.
EQ. EQ.
G*
EQ. EQ.
1 1/4" 1 1/4"
S-09 SCALE: 1-1/2" = 1'-0"
T SECTION
G*
1'-2"
G*
G*
R
S-08
R
S-08
T
S-09
S-09 SCALE: 1-1/2" = 1'-0"
15 HORIZONTAL SPLICE
9 1/2"
7/8"
TYP.
1 1/2"
TYP.
7/8"
TYP.
TOP VIEW
FRONT VIEW
NEW 4"x4"x1/4"
FRP TUBE
KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
EXISTING FRP
COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
EXISTING FRP
KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
EXISTING COLUMN
EXISTING FRP
HORIZONTAL
TUBE
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
EXISTING FRP
COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
EXISTING FRP
MOUNTING BRACKET
(F.V. SIZE, NOTIFY EOR
OF FINDINGS)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
EXISTING FRP
COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
EXISTING FRP
MOUNTING BRACKET
(F.V. SIZE, NOTIFY EOR
OF FINDINGS)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
FIELD DRILL
13/16"Ø HOLE FOR
NEW THREADED
ROD (TYP.)
FIELD DRILL
13/16"Ø HOLE FOR
NEW END BOLT
(TYP.)
NEW L4x4x1/4
HORIZONTAL
BRACING
DRILL 9/16"Ø
HOLES FOR NEW
U-BOLT (TYP.)
NEW P2 STD PIPE
MOUNT
(2) NEW 1/2"Ø U-BOLT
CONNECTION, INSIDE
DIAMETER OF U-BOLT
SHALL MATCH
OUTSIDE DIAMETER
OF PIPE
NEW L4x4x1/4
HORIZONTAL
BRACING
NEW 3/4"Ø END
BOLTS, LENGTH
AS REQUIRED
(TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
END BOLT
(TYP.)
EXISTING
SCREEN WALL
HORIZONTAL
EXISTING
SCREEN WALL
HORIZONTAL
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
NEW 3/8" THICK
PLATE (TYP OF TOP
AND BOTTOM)
DRILL 9/16"Ø HOLE
FOR NEW
CONNECTION BOLT
(TYP.)
NEW 1/2"Ø
CONNECTION
BOLTS, LENGTH
AS REQUIRED
(TYP.)
FEILD DRILL 9/16"Ø
HOLE FOR NEW
CONNECTION BOLT
(TYP.)
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
NOTE:
1. ALL FIELD DRILLED HOLES SHALL BE
SOLVENT CLEANED AND TOUCHED UP WITH
TWO COATS OF BRUSH APPLIED ZRC ZINC
RICH COLD GALVANIZING PAINT.
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
SIDE VIEW
BOTTOM VIEW
8"
1 1/4"
TYP.
NEW L4x4x1/4
BACKER ANGLE
G*
DRILL 13/16"Ø
HOLES FOR BOLT
ASSEMBLY (TYP.)
NEW 3/4"Ø BOLTS
ASSEMBLY,
LENGTH AS
REQUIRED (TYP.)
S-09 SCALE: 1-1/2" = 1'-0"
16 TOP PLATE
6"
F.V.
2"
2"
1 1/4" MIN.
(F.V.)
2"
3/8" THICK FRP
PLATE
DRILL 13/16"Ø
HOLES FOR FRP
THREADED RODS
(TYP.)
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
1'-2"
NEW 4"x4"x1/4"
FRP TUBE
KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8 FRP
ANGLE (TYP.)
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
NEW 4"x4"x1/4" FRP
TUBE COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
2"
G*
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8 FRP
ANGLE (TYP.)
NEW 4"x4"x1/4"
FRP TUBE
COLUMN/ KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8 FRP
ANGLE (TYP.)
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
EXISTING COLUMN
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
EXISTING
KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
(TYP.)
R
S-08
EXISTING
KICKER
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
FIELD DRILL
13/16"Ø HOLE FOR
NEW THREADED
ROD (TYP.)
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
(TYP.)
EXISTING FRP
COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
*SEE WORKABLE ANGLE GAGE ON SHEET N-01 *SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01 *SEE WORKABLE ANGLE GAGE ON SHEET N-01
S
S-08
3/8" THICK FRP
PLATE (TYP. OF
BOTH SIDED), SEE
DETAIL 16/S-09
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8 FRP
ANGLE (TYP.)
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
(TYP.)
NEW 4"x4"x1/4"
FRP TUBE
KICKER
NEW L4x4x1/4
HORIZONTAL
BRACING
DRILL 9/16"Ø
HOLES FOR
NEW U-BOLT
NEW P2 STD PIPE
MOUNT
(2) NEW 1/2"Ø U-BOLT
CONNECTION, INSIDE
DIAMETER OF U-BOLT
SHALL MATCH
OUTSIDE DIAMETER
OF PIPE
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8 FRP
ANGLE (TYP.)
NEW/ EXISTING FRP
HORIZONTAL TUBE
NEW 4"x4"x1/4" FRP
TUBE COLUMN
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW 3/4"Ø FRP
THREADED ROD,
LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
NEW L4x4x3/8
FRP ANGLE
(TYP.)
NEW 4"x4"x1/4" FRP
TUBE COLUMN
NEW 2-1/2"x2-1/2"x1/4"
FRP HORIZONTAL
TUBE
DRILL 13/16"Ø
HOLE FOR NEW
THREADED ROD
(TYP.)
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
TOP VIEW
SIDE VIEW
NEW L4x4x1/4
BACKER ANGLE
8"
1 1/4"
TYP.
G*
DRILL 13/16"Ø
HOLES FOR BOLT
ASSEMBLY (TYP.)
NEW 3/4"Ø BOLTS
ASSEMBLY,
LENGTH AS
REQUIRED (TYP.)
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
F.V.
G*
TYP.
1'-2"
(F.V.)
2'-7"
(F.V.)
4'-4"
(F.V.)
5'-9"
(F.V.)
11"
1'-8"
(F.V.)
2'-0"
(F.V.)
2'-8"
(F.V.)
2'-8"
(F.V.)
6"
(F.V.)
9'-6"
(F.V.)
G*
TYP.
S-06 SCALE: 1-1/2" = 1'-0"
4 KICKER BASE
S-06 SCALE: 1-1/2" = 1'-0"
L SECTION
S-06 SCALE: 1-1/2" = 1'-0"
5 COLUMN BASE
S-08
8
S-07
6
S-06
4
S-06
5
S-07
7
S-08
10
S-09
11
S-08
9
L
S-06
REPLACE EXISTING SCREEN
WALL HORIZONTAL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL KICKER
WITH NEW 4"x4"x1/4" FRP TUBE
(F.V. REQUIRED LENGTH PRIOR
TO ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
NEW 3/4"Ø BOLT CONNECTION ,
LENGTH AS REQUIRED (TYP.)
REPLACE EXISTING SCREEN
WALL HORIZONTAL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
EXISTING SCREEN WALL KICKER
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
NEW 3/4"Ø BOLT CONNECTION ,
LENGTH AS REQUIRED (TYP.)
EXISTING SCREEN WALL
COLUMN
4"
EQ. EQ.
G*
4"
EQ. EQ.
G*
2"
1/4
ANGLE TO
HSS (TYP.)
1/4
ANGLE TO
HSS (TYP.)
1/4
1/4
ANGLE TO
HSS
1/4
HSS12x4x1/4
FRAME BASE
NEW L4x4x1/4
CLIP ANGLE
NEW 3/4"Ø END
BOLTS, LENGTH
AS REQUIRED
(TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
END BOLT
(TYP.)
NEW 4"x4"x1/4"
FRP TUBE
KICKER
HSS12x4x1/4
FRAME BASE
NEW L4x4x1/4
CLIP ANGLE
NEW 3/4"Ø END
BOLTS, LENGTH
AS REQUIRED
(TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
END BOLT
(TYP.)
NEW 4"x4"x1/4"
FRP TUBE
COLUMN
L
S-06
HSS12x4x1/4
FRAME BASE
NEW L4x4x1/4
CLIP ANGLE
NEW 3/4"Ø END
BOLTS, LENGTH AS
REQUIRED (TYP.)
DRILL 13/16"Ø
HOLE FOR NEW
END BOLT (TYP.)
NEW COLUMN/
KICKER
*SEE WORKABLE ANGLE GAGE ON SHEET N-01 *SEE WORKABLE ANGLE GAGE ON SHEET N-01
TYP.
TYP.
TYP.
TYP.
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-0"±
(TYP., F.V.)
1'-7"
TYP.
J
S-06
S-09
15
REPLACE EXISTING SCREEN
WALL HORIZONTAL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
REPLACE SCREEN WALL KICKER
WITH NEW 4"x4"x1/4" FRP TUBE
(F.V. REQUIRED LENGTH PRIOR
TO ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER, SEE
SECTION J/S-06
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER,
SEE SECTION K/S-06
REPLACE SECTION OF STEEL
SCREEN WALL WITH NEW FRP
SCREEN WALL, SCREEN WALL
TO BE DESIGNED BY OTHERS
(F.V. SIZE AND LOCATION),
DELIVERY AND INSTALLATION
COORDINATED BY
CONTRACTOR
EXISTING SCREEN WALL
COLUMN (TYP.)
EXISTING SCREEN WALL KICKER
(TYP.) NEW 8'-0" LONG P2 STD PIPE
MOUNT (TYP. OF 3)
TYP.
TYP. TYP.
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
6'-3"±
(F.V.)
6'-2"±
(F.V.)
3'-0
25'-2"±
(F.V.)
EQ.
TYP.
EQ.
TYP.
G
S-05
N
S-07
G*
TYP.
H
S-05
S-09
11
S-08
10
S-09
13
S-09
14
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
EXISTING SCREEN WALL KICKER
EXISTING SCREEN WALL
COLUMN
EXISTING SCREEN WALL
HORIZONTAL (TYP. OF 3)
NEW 3/4"Ø BOLT CONNECTION ,
LENGTH AS REQUIRED (TYP.)
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER
EXISTING FRP SCREEN WALL
HORIZONTAL (TYP. OF 3)
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
EXISTING SCREEN WALL
COLUMN
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
NEW 8'-0" LONG P2 STD PIPE
EXISTING FRP BRACING MOUNT (TYP. OF 3)
(TYP.)
REPLACE EXISTING OF SCREEN
WALL HORIZONTALS WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
REPLACE SCREEN WALL KICKER
WITH NEW 4"x4"x1/4" FRP TUBE
(F.V. REQUIRED LENGTH PRIOR
TO ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER, SEE
SECTION J/S-06
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER,
SEE SECTION K/S-06
*SEE WORKABLE ANGLE GAGE ON SHEET N-01 *SEE WORKABLE ANGLE GAGE ON SHEET N-01
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
S-09
12
TYP.
TYP.
TYP.
TYP.
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
RE-USE OR REPLACE EXISTING
DIAGONAL BRACING WITH NEW
OF SAME LIKE KIND (TYP.)
5'-9"
(F.V.)
F.V.
1'-2"
(F.V.)
2'-7"
(F.V.)
4'-4"
(F.V.)
5'-9"
(F.V.)
11"
1'-8"
(F.V.)
2'-0"
(F.V.)
2'-8"
(F.V.)
2'-8"
(F.V.)
6"
(F.V.)
9'-6"
(F.V.)
1'-6"
17'-4±
(F.V.)
9'-9"±
(F.V.)
1 3/16"
TYP.
F.V. & MATCH
EXISTING
LOCATION
F
S-04
E
S-04
1'-5"
U
S-09
G*
TYP.
G*
TYP.
G*
TYP.
S-08
8
S-07
6
S-06
4
S-06
5
S-07
7
S-08
10
S-09
11
S-08
9
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL KICKER
WITH NEW 4"x4"x1/4" FRP TUBE
(F.V. REQUIRED LENGTH PRIOR
TO ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
EXISTING FRP SCREEN WALL
HORIZONTAL (TYP. OF 3)
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
NEW 3/4"Ø BOLT CONNECTION ,
LENGTH AS REQUIRED (TYP.)
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
EXISTING SCREEN WALL KICKER
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER
EXISTING FRP SCREEN WALL
HORIZONTAL (TYP. OF 3)
NEW 3/4"Ø FRP THREADED ROD
CONNECTION , LENGTH AS
REQUIRED (TYP.)
NEW 3/4"Ø BOLT CONNECTION ,
LENGTH AS REQUIRED (TYP.)
EXISTING SCREEN WALL
COLUMN
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER,
SEE SECTION F/S-04
EXISTING SCREEN WALL KICKER
EXISTING SCREEN WALL
COLUMN
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
S-09
15
TYP.
TYP.
TYP.
TYP.
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
REMOVE ALL STEEL AND
EQUIPMENT IN FRONT OF THE
ANTENNA POSITION
18'-6"±
(TYP., F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
6'-2"±
(F.V.)
D
S-03
C
S-03
N
S-07
G*
TYP.
1'-7"
TYP.
S-09
15
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
REPLACE SCREEN WALL
KICKER WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER, SEE
SECTION C/S-03
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER,
SEE SECTION D/S-03
REPLACE EXISTING TOP CHORD
OF SCREEN WALL WITH NEW
2-1/2"x2-1/2"x1/4" FRP TUBE (F.V.
REQUIRED LENGTH PRIOR TO
ORDERING MATERIAL)
REPLACE SCREEN WALL
COLUMN WITH NEW 4"x4"x1/4"
FRP TUBE (F.V. REQUIRED
LENGTH PRIOR TO ORDERING
MATERIAL)
REPLACE SCREEN WALL KICKER
WITH NEW 4"x4"x1/4" FRP TUBE
(F.V. REQUIRED LENGTH PRIOR
TO ORDERING MATERIAL)
INSTALL NEW L4x4x1/4
HORIZONTAL BRACING TO
SUPPORT NEW PIPE MOUNTS
(TYP. OF 2)
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN NEW
COLUMN AND NEW KICKER, SEE
SECTION C/S-03
INSTALL NEW L4x4x3/8 FRP
BRACING BETWEEN EXISTING
COLUMN AND EXISTING KICKER,
SEE SECTION D/S-03
REPLACE SECTION OF STEEL
SCREEN WALL WITH NEW FRP
SCREEN WALL, SCREEN WALL
TO BE DESIGNED BY OTHERS
(F.V. SIZE AND LOCATION),
DELIVERY AND INSTALLATION
COORDINATED BY
CONTRACTOR
EXISTING SCREEN WALL
COLUMN (TYP.)
EXISTING SCREEN WALL
KICKER (TYP.)
NEW 8'-0" LONG P2 STD PIPE
MOUNT (TYP. OF 3)
*SEE WORKABLE ANGLE GAGE ON SHEET N-01
TYP.
TYP.
TYP. TYP.
NOTE:
ALL FRP THREADED RODS ARE 3/4"Ø AND
FIBERBOLTS WITH (2) FIBERGLASS BUTS
UNLESS NOTED OTHERWISE.
INSTALL NEW ANGLE MOUNTING FRAME
BETWEEN KICKERS.
PIPE MOUNTS (3) P2 STD (3) P2 STD REPLACE EXISTING PIPE MOUNTS WITH
NEW.
KICKERS VARIES (3) 4"x4"x1/4 FRP
TUBE
REPLACE EXISTING STEEL KICKERS WITH
NEW FRP MEMBER.
BETA
MOUNTING
FRAME
53'-0"±
- L4x4x1/4
2/S-03
INSTALL NEW ANGLE MOUNTING FRAME
BETWEEN KICKER AND SCREEN WALL.
BRACING - L4x4x3/8 FRP INSTALL NEW FRP BRACING BETWEEN
COLUMNS AND KICKERS.
TOP CHORD HSS2-1/2x2-1/2x1/4 2-1/2"x2-1/2"x1/4"
FRP TUBE
REPLACE EXISTING STEEL TOP CHORD WITH
NEW FRP MEMBER.
EQUIPMENT - -
RELOCATE ALL EXISTING STEEL AND
EQUIPMENT IN FRONT OF ANTENNA TO NEW
FRAME.
PIPE MOUNT (1) P2 STD (1) P2 STD REPLACE EXISTING PIPE MOUNTS WITH
NEW.
GAMMA
SCREEN WALL
53'-0"±
STEEL SCREEN WALL FRP SCREEN WALL
PANEL
3/S-04
REPLACE STEEL SCREEN WALL WITH NEW
FRP MATERIALS.
BRACING - L4x4x3/8 FRP INSTALL NEW FRP BRACING BETWEEN
COLUMNS AND KICKERS.
HORIZONTALS (4) HSS2-1/2x2-1/2x1/4 (4) 2-1/2"x2-1/2"x1/4"
FRP TUBE
REPLACE EXISTING STEEL HORIZONTALS
WITH NEW FRP MEMBERS.
COLUMNS VARIES (3) 4"x4"x1/4 FRP
TUBE
REPLACE EXISTING STEEL COLUMN WITH
NEW FRP MEMBERS.
MOUNTING
FRAME - L4x4x1/4
INSTALL NEW ANGLE MOUNTING FRAME
BETWEEN KICKERS.
PIPE MOUNTS (3) P2 STD (3) P2 STD REPLACE EXISTING PIPE MOUNTS WITH
NEW.
EQUIPMENT - -
ABANDON EXISTING GAMMA MOUNTS AND
RELOCATE EXISTING EQUIPMENT TO NEW
FRAME.
KICKERS VARIES (3) 4"x4"x1/4 FRP
TUBE
REPLACE EXISTING STEEL KICKERS WITH
NEW FRP MEMBERS.
S-03
2
S-02
1
S-04
3
N.T.S.
ROOFTOP PLAN
NORTH
NEW
GAMMA
SECTOR
ALPHA
SECTOR
BETA
SECTOR
EXISTING
EQUIPMENT
SHELTER
EXISTING
PENTHOUSE
EXISTING
EQUIPMENT
PLATFORM
EXISTING
EQUIPMENT
PLATFORM
EXISTING
EQUIPMENT
PLATFORM
EXISTING
EQUIPMENT
PLATFORM
EXISTING
ROOFTOP
REPLACE EXISTING
SCREEN WALL SUPPORTS
AND SECTION OF SCREEN
WALL, SEE DETAIL 1/S-02
REPLACE EXISTING
SCREEN WALL TOP CHORD
AND RELOCATE
EQUIPMENT TO NEW
HORIZONTAL FRAMING, SEE
DETAIL 2/S-03
REPLACE EXISTING
SCREEN WALL
SUPPORTS AND
SECTION OF SCREEN
WALL, SEE DETAIL
3/S-04
RELOCATE ALL
EXISTING GAMMA
EQUIPMENT TO NEW
EQUIPMENT FRAME,
SEE DETAIL 3/S-04
NOTE:
1. ALL MATERIAL REMOVED FROM THE TOWER SHALL BE DISPOSED OF BY THE CONTRACTOR OFF SITE.
2. CONTRACTOR SHALL TEMPORALITY SUPPORT EXISTING EQUIPMENT DURING INSTALLATION OF NEW MODIFICATIONS.
3. 2. ANY SUBSTITUTION OF PARTS SPECIFIED IN THIS DESIGN PACKAGE SHALL REQUIRE ENGINEER APPROVAL PRIOR TO FABRICATION.
UV INHIBITOR TO PREVENT MOISTURE INFILTRATION.
8. ALL FIELD CUT AND DRILLED EDGES, HOLES, AND ABRASIONS SHALL BE SEALED WITH A
CATALYZED RESIN COMPATIBLE WITH THE ORIGINAL RESIN AS RECOMMENDED BY THE
MANUFACTURER OF THE FRP COMPONENT. THE SEALING RESIN SHALL CONTAIN A UV INHIBITOR.
9. COATINGS SHALL BE OF A TEXTURE AND COLOR TO MATCH NEARBY EXISTING SURFACES. PAINTED
COATING SHALL BE A TWO-COMPONENT UV STABILIZED URETHANE COATING COMPATIBLE WITH
THE FRP COMPONENTS IN THE VISION SCREEN. PAINTING AND COLOR REQUIREMENTS SHALL BE
CONFIRMED WITH THE OWNER.
10. MATERIAL PROPERTIES LENGTH WISE (LW) AND CROSSWISE (CW) OF THE FRP COMPONENTS
SHALL BE EQUAL TO OR GREATER THAN THE FOLLOWING:
11. ALL FRP MEMBERS SHALL BE STRONGWELL.
PROPERTY SERIES 500/525
MECHANICAL
TENSILE STRESS, LW 30,0000
TENSILE STRESS, CW 7,000
TENSILE MODULUS, LW 2.5
TENSILE MODULUS, CW 0.8
COMPRESSIVE STREE, LW 30,000
COMPRESSIVE STREE, CW 15,000
COMPRESSIVE MODULUS, LW 2.5
COMPRESSIVE STREE, CW 0.8
FLEXURAL STRESS, LW 30,000
FLEXURAL STRESS, CW 10,000
FLEXURAL MODULES, LW 1.6
FLEXURAL MODULES, CW 0.8
MODULUS OF ELASTICITY, LW 2.6
MODULUS OF ELASTICITY, LW 2.5
(W AND I SHAPES > 4")
SHEAR MODULUS, LW 0.425
SHORT BEAM SHEAR, LW 4,500
ULTIMATE BEARING STREE, LW 30,000
POISSON'S RATIO, LW 0.33
NOTCHED IZOD IMPACT, LW 25
NOTCHED IZOD IMPACT, CW 4
1
2
2
3
4 8
7 8
8
LIMITED TO, THOSE LISTED IN SECTION 312.1 (IBC SECTION 1704.2, EXCEPTION 2). CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING IF ANY SPECIAL INSPECTIONS ARE REQUIRED BY THE JURISDICTION HAVING
AUTHORITY. IF REQUIRED BY THE JURISDICTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
COORDINATION AND SCHEDULING OF THE SPECIAL INSPECTIONS WITH THE ENGINEER OF RECORD. IN THOSE
CASES, SPECIAL INSPECTIONS MUST BE COMPLETED PRIOR TO FINAL INSPECTION APPROVAL.
7. INSTALLATION OF THE PROPOSED LOADING IS BY OTHERS AND IS BEYOND THE SCOPE OF THESE DRAWINGS.
8. ALL CONTRACTORS AND LOWER TIER CONTRACTORS MUST ACKNOWLEDGE IN WRITING TO THE OWNER AND
GPD THAT THEY HAVE OBTAINED, UNDERSTAND, AND WILL FOLLOW THE OWNER STANDARDS OF PRACTICE,
CONSTRUCTION GUIDELINES, ALL SITE AND TOWER SAFETY PROCEDURES, ALL PRODUCT LIMITATIONS AND
INSTALLATION PROCEDURES USED ON SITE, AND PROPOSED MODIFICATIONS DESCRIBED. RECEIPT OF
ACKNOWLEDGMENT MUST OCCUR PRIOR TO BEGINNING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO PROVIDE THIS DOCUMENTATION FOR THE OWNER AND GPD ON COMPANY LETTERHEAD AND
IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO OBTAIN THIS DOCUMENTATION FROM LOWER TIER
SUBCONTRACTORS (ON SUBCONTRACTOR LETTERHEAD) AND DELIVER IT TO THE OWNER AND GPD.
9. STRUCTURAL MODIFICATION WORK SPECIFIED ON THESE PLANS SHALL BE ACCOMPLISHED BY
KNOWLEDGEABLE WORKMEN WITH CONSTRUCTION EXPERIENCE. THE CONTRACTOR SHALL SUBMIT
CERTIFICATIONS TO THE OWNER AND ENGINEER.
10. CONTRACTOR SHALL PERFORM ALL WORK IN SUCH A MANNER AS TO PROTECT THE EXISTING AND ADJACENT
STRUCTURES AND SHALL BE RESPONSIBLE TO PROPERLY REPAIR ANY DAMAGE THAT OCCURS AS A RESULT
OF THE WORK.
11. CEASE OPERATIONS AND NOTIFY OWNER AND ENGINEER IMMEDIATELY IF THE SAFETY OR INTEGRITY OF THE
STRUCTURE APPEARS TO BE ENDANGERED. PROPERLY BRACE AND SUPPORT STRUCTURE BEFORE
RESUMING OPERATIONS.
12. DO NOT CUT OR ALTER ANY STRUCTURAL MEMBERS WITHOUT WRITTEN AUTHORIZATION OF THE ENGINEER
UNLESS INDICATED ON THE STRUCTURAL DRAWINGS.
13. THESE DRAWINGS DO NOT INDICATE THE METHOD OF CONSTRUCTION. ANY TECHNIQUES OR PROCEDURES
IMPLIED BY THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE SUGGESTIONS ONLY. THE CONTRACTOR
SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION
METHODS, MEANS, TECHNIQUES, SEQUENCES, AND PROCEDURES.
14. THE CONTRACTOR AND ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE SAFETY OF THEIR WORK
FORCE, THE WORK AREA, ADJACENT AREA, AND ANY PROPERTY OCCUPANTS WHO MAY BE AFFECTED BY THE
WORK UNDER CONTRACT. THE CONTRACTOR SHALL REVIEW AND ABIDE BY ALL OWNER, PRIME
CONTRACTOR, CARRIER, OSHA, AND LOCAL SAFETY GUIDELINES. ALL WORKERS SHALL UTILIZE APPROPRIATE
FALL PROTECTION AND SAFETY EQUIPMENT THAT IS UP-TO-DATE AND INSPECTED PER OSHA AND INDUSTRY
GUIDELINES. ALL WORKERS SHALL BE TRAINED AND MONITORED TO ENSURE SAFE WORKING PRACTICES ARE
MAINTAINED.
15. CONTRACTOR IS RESPONSIBLE FOR TEMPORARILY REMOVING ALL COAX, T-BRACKETS, ANTENNA MOUNTS,
AND ANY OTHER APPURTENANCE THAT MAY INTERFERE WITH THE MODIFICATIONS. ALL APPURTENANCES
MUST BE REPLACED AND/OR RESTORED TO ITS ORIGINAL LOCATION. SOME ATTACHMENTS MAY REQUIRE
CUSTOM MODIFICATIONS TO PROPERLY FIT THE MODIFIED REGION OF THE STRUCTURE. THESE
CUSTOMIZATIONS ARE DESIGNED BY OTHERS AND MUST BE APPROVED BY THE ENGINEER PRIOR TO
REMOVING SUCH ATTACHMENTS. ANY CARRIER DOWNTIME MUST BE COORDINATED WITH THE OWNER IN
WRITING.
16. CONTRACTOR SHALL ONLY WORK WITHIN THE LIMITS OF THE OWNER'S PROPERTY OR LEASE AREA AND
APPROVED EASEMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY WORK IS WITHIN THESE
BOUNDARIES. CONTRACTOR SHALL EMPLOY A SURVEYOR AS REQUIRED. ANY WORK OUTSIDE THESE
BOUNDARIES SHALL BE APPROVED IN WRITING BY THE LAND OWNER PRIOR TO MOBILIZATION.
CONSTRUCTION STAKING AND BOUNDARY MARKING IS THE RESPONSIBILITY OF THE CONTRACTOR.
17. THE STRUCTURAL INTEGRITY OF THIS DESIGN EXTENDS TO THE COMPLETE CONDITION ONLY. THE
CONTRACTOR MUST BE COGNIZANT THAT THE REMOVAL OF ANY STRUCTURAL COMPONENT HAS THE
POTENTIAL TO CAUSE THE PARTIAL OR COMPLETE COLLAPSE OF THE STRUCTURE. ALL NECESSARY
PRECAUTIONS MUST BE TAKEN TO ENSURE THE STRUCTURAL INTEGRITY, INCLUDING, BUT NOT LIMITED TO,
ENGINEERING ASSESSMENT OF CONSTRUCTION STRESSES WITH INSTALLATION MAXIMUM WIND SPEED
AND/OR TEMPORARY BRACING AND SHORING.
18. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY LOCAL SHORING, TEMPORARY GLOBAL SHORING, AND
ALL SHORING OF SURROUNDING BUILDINGS, PADS, AND OTHER OUTDOOR SITE OBSTRUCTIONS. ALL
SHORING, TEMPORARY BRACING, AND TEMPORARY SUPPORTS ARE THE RESPONSIBILITY OF THE
CONTRACTOR.
19. FAA/FCC FILING AND LIGHTING MAY BE REQUIRED. ALL GOVERNMENTAL REGULATORY DETERMINATIONS AND
FILINGS BY OTHERS, NOT GPD.
20. CONTRACTOR SHALL TAKE NECESSARY ACTIONS TO PROVIDE SAFE WORKING CONDITIONS INCLUDING, BUT
NOT LIMITED TO, HAVING ANY FM SIGNALS TURNED OFF. CONTRACTOR SHALL HAVE PROPER RADMAN FOR
NOTIFICATION OF EXCESSIVE RF EXPOSURE FOR ALL INDIVIDUALS WORKING ON SITE IF FM ANTENNAS ARE
PRESENT. CONTRACTOR SHALL BE AWARE OF RF WARNING SIGNS AND TAKE PROPER PRECAUTIONS.
21. ALL MANUFACTURERS HARDWARE AND ASSEMBLY INSTRUCTIONS SHALL BE FOLLOWED EXACTLY. DEVIATION
FROM THE INSTRUCTIONS IS UNACCEPTABLE AND REQUIRES WRITTEN APPROVAL FROM ENGINEER.
22. DO NOT SCALE DRAWINGS.
23. ROOFTOP ACCESS, CLIMBING FACILITIES, SAFETY CLIMB AND ALL ASSOCIATED HARDWARE SHALL NOT BE
IMPEDED OR MODIFIED WITHOUT THE WRITTEN CONSENT OF GPD.
24. ANY WORK PERFORMED WITHOUT A PREFABRICATION MAPPING IS DONE AT THE RISK OF THE GC AND/OR
FABRICATOR.
25. IMPROPER FIT-UP OF NEW BOLTED HARDWARE DUE TO OVERSIZED , DOUBLE-PUNCHED, OR SLOTTED HOLES
FOUND ON THE EXISTING STRUCTURE SHALL BE REPORTED TO GPD AND THE TOWER OWNER IMMEDIATELY.
INSTALLATION OF SUCH HARDWARE WILL NOT BE ACCEPTABLE AND ALL COSTS ASSOCIATED WITH
REMEDYING THE INSTALLATION WILL BE THE RESPONSIBILITY OF THE GC.
STRUCTURAL STEEL NOTES
1. ALL NEW STEEL SHALL BE HOT-DIPPED GALVANIZED PER ASTM A123, ASTM A153/A153M, OR ASTM A653 G90, AS
APPLICABLE FOR FULL WEATHER PROTECTION. FOR HIGH STRENGTH STEEL FASTENERS WHERE HOT-DIPPED
GALVANIZING IS NOT PERMITTED MAGNI 565 COATING (OR ENGINEER APPROVED EQUIVALENT) SHALL BE
USED. IN ADDITION ALL NEW STEEL SHALL BE PAINTED TO MATCH EXISTING STEEL AND/OR BUILDING
MATERIAL. CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION TO PROTECT STEEL BY ANY OTHER MEANS.
2. ALL EXPOSED STRUCTURAL STEEL AS THE RESULT OF THIS SCOPE OF WORK INCLUDING, BUT NOT LIMITED
TO, DAMAGED MEMBERS, FIELD WELDS, FIELD CUT MEMBERS, FIELD DRILLED HOLES, AND SHAFT INTERIORS
(WHERE APPLICABLE), SHALL BE SOLVENT CLEANED AND HAVE TWO (2) COATS OF BRUSHED ON ZRC ZINC
RICH COLD GALVANIZING PAINT APPLIED AND SHALL BE PAINTED TO MATCH THE TOWER FINISH (WHERE
APPLICABLE). PHOTO DOCUMENTATION IS REQUIRED TO BE SUBMITTED TO THE MODIFICATION INSPECTOR.
3. ALL STRUCTURAL STEEL SHALL CONFORM TO THE LISTED REQUIREMENTS U.N.O. IN THESE DRAWINGS:
· STEEL ANGLE: ASTM A36 (Fy=36 KSI)
· SOLID ROUND: ASTM A36 (FY=36 KSI)
· PIPE (ROUND): ASTM A53 GRADE B (Fy=35 KSI)
· HSS TUBE (ROUND): ASTM A500 GRADE C (Fy=46 KSI)
· HSS TUBE (SQUARE): ASTM A500 GRADE C (Fy=50 KSI)
· W-SHAPES: ASTM A992 (Fy=50 KSI)
· CHANNELS: ASTM A36 (Fy=36 KSI)
· PLATE: ASTM A572 GRADE 50 (Fy=50KSI)
· ANCHOR RODS: ASTM A193 GRADE B7
· BOLTS: ASTM A325 TYPE 1
· U-BOLTS: ASTM A307 GRADE A
· NUTS: ASTM A563 GRADE DH
· NUTS (ANCHOR RODS): ASTM A194 GRADE 2H
· WASHERS (AS REQUIRED): ASTM F436 TYPE 1
· LOCKING DEVICES: PAL-NUT OR SPLIT WASHER
· WELDING ELECTRODES, SMAW: E70XX
· WELDING ELECTRODES, FCAW: E7XT-XX
4. ALL BOLT ASSEMBLIES FOR STRUCTURAL MEMBERS REPRESENTED IN THIS DRAWING REQUIRE LOCKING
DEVICES TO BE INSTALLED.
5. ALL BOLTS, INCLUDING U-BOLTS, SHALL BE TIGHTENED IN ACCORDANCE WITH AISC "SNUG TIGHT"
REQUIREMENTS, U.N.O.
6. ALL U-BOLTS SPECIFIED SHALL MEET THE REQUIREMENTS OF ASME B18.31.5-2011 BENT BOLTS.
7. ALL NEW BOLT ASSEMBLIES SHALL BE OF SUFFICIENT LENGTH TO ENSURE THE END OF THE BOLT IS FLUSH
WITH, OR PROTRUDES BEYOND, THE FACE OF THE NUT AFTER TIGHTENING IS COMPLETE.
8. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE PROVIDED TO ENGINEER FOR REVIEW PRIOR TO
FABRICATION.
9. UNLESS NOTED OTHERWISE, ALL NEW MEMBERS SHALL MAINTAIN THE EXISTING MEMBER WORK LINES AND
NOT INTRODUCE ECCENTRICITIES INTO THE STRUCTURE.
10. WELDING OF ANY KIND IS NOT PERMITTED ON SITE UNLESS SPECIFIED WITHIN THESE DRAWINGS. OXY FUEL
GAS WELDING OR BRAZING IS STRICTLY PROHIBITED. SPECIFICALLY, NO TORCH CUTTING OR OPEN FLAME IS
PERMITTED ON SITE. ALL HOLES SHALL BE CUT WITH A GRINDER.
ROOFING NOTES
1. THE SUBCONTRACTOR SHALL REPAIR ALL EXISTING FLOOR, ROOF, CEILING, AND WALL SURFACES AND
FINISHING DISTURBED DURING CONSTRUCTION. ALL EXTERIOR FINISHES ARE REQUIRED TO RESULT IN A
SMOOTH FINISH TO MATCH THE EXISTING CONDITIONS TO THE SATISFACTION OF THE OWNER.
2. PENETRATION OF THE ROOF MEMBRANE IS PROHIBITED EXCEPT WHERE DESIGNED AND WITH THE APPROVAL
OF THE BUILDING OWNER OR MANAGEMENT. COORDINATE MEMBRANE REPLACEMENT AND/OR REPAIR WITH
THE OWNER'S ROOFING CONSULTANT TO MAINTAIN EXISTING WARRANTY.
3. ROOFTOP HAS A SLIGHT SLOPE TOWARDS EXISTING ROOF DRAINS. ALL EXISTING ROOF DRAINS & ROOF
DRAINING PATTERNS SHALL NOT BE OBSTRUCTED OR DISTURBED (VERIFY IN FIELD). ANTENNA FRAMES AND
STRUCTURE SHALL BE PLUMB & LEVEL (SHIM AS REQUIRED).
ALLOWABLE ANGLE COPE
L
1.5xL
MAX.
BOLT HOLE
DO NOT COPE
BEYOND THIS LINE
COPED
ANGLE
COPED
ANGLE
LEG 4
WORKABLE GAGES
3-1/2 3 2-1/2 2 1-3/4
G 2-1/2 2 1-3/4 1-3/8 1-1/8 1
"G"
-DIMENSIONS GIVEN IN
INCHES
-MATCH EXISTING WHEN
APPLICABLE
-DIMENSIONS GIVEN IN INCHES
BOLT
DIAMETER
STANDARD
HOLE
BOLT SCHEDULE
9/16
11/16
13/16
1/2
3/4
1-1/8
15/16
SHORT SLOT
9/16x11/16
11/16x7/8
13/16x1
1-1/8x1-5/16
15/16x1-1/8
MIN. EDGE
DISTANCE
5/8
7/8
1
C-C SPACING
7/8
1-1/8
1-1/4
1-3/4
1-1/2
1-1/2
1-7/8
2-1/4
3
2-5/8
-SHORT SLOT HOLES SHALL ONLY
BE USED WHEN DEPICTED ON
THE PLANS
5
3
HEAVY HEX
NUT
LOCK
WASHER NEW/EXISTING
CONNECTED
MEMBERS
STRUCTURAL
BOLT
TYPICAL BOLT ASSEMBLY
C-C SPACING MIN. EDGE
DISTANCE
TYPICAL STITCH WASHER
F.V.
MATCH
ANGLE
HEIGHT
MATCH
ANGLE
HEIGHT
BOLTING DETAILS
6
3-1/2
1. ALL DIMENSIONS REPRESENTED IN THESE TABLES ARE AISC MINIMUM
REQUIREMENTS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN
FIELD AND NOTIFY ENGINEER IF DISTANCES ARE LESS THAN THOSE
PROVIDED.
2. THE DIMENSIONS PROVIDED ARE MINIMUM REQUIREMENTS. ACTUAL
DIMENSIONS OF PROPOSED MEMBERS WITHIN THESE DRAWINGS MAY VARY
FROM THE AISC MINIMUM REQUIREMENTS.
3. AS AN ALTERNATIVE TO USING A LOCK WASHER PAL-NUTS CAN BE INSTALLED
ABOVE THE HEX NUT. ALL BOLTS MUST HAVE LOCKING DEVICES INSTALLED
AS PART OF THE ASSEMBLY.
4. ADDITIONAL HARDENED FLAT WASHERS MAY BE REQUIRED IN CASES WHERE
OVERSIZED OR SLOTTED HOLES ARE PRESENT. EXISTING CONDITIONS SHALL
BE APPROVED BY THE EOR.
WELD NOTES
1. ALL WELDING SHALL BE DONE IN ACCORDANCE WITH AWS D1.1/D1.1M, "STRUCTURAL WELDING CODE-STEEL".
2. CONTRACTOR IS RESPONSIBLE FOR COMMISSIONING A THIRD PARTY CERTIFIED WELD INSPECTOR (CWI)
THROUGHOUT THE ENTIRETY OF THE PROJECT. A PASSING CWI REPORT SHALL BE PROVIDED TO THE
MODIFICATION INPECTOR UPON COMPLETION OF THE PROJECT.
3. WELDING CERTIFICATES MUST BE PROVIDED TO CWI AND GPD PRIOR TO WELDING CONTRACTOR BEGINNING
WORK ON SITE. CERTIFICATE WILL BE ASKED FOR AS PART OF INSPECTION PROCESS. ALL WELDING SHOULD
BE PERFORMED BY AN AWS QUALIFIED WELDER WHO HAS EXPERIENCE WITH GALVANIZED SURFACES AND IN
ACCORDANCE WITH ANSI/AWS D1.1 AND ANSI Z 49.1.
4. INSTALL 3000° (NFPA 701) FIRE BLANKET AROUND ALL COAX AT AND BELOW EACH WELDING PROCEDURE AND
ELEVATION. COAX IS FLAMMABLE AND CAN CATCH FIRE IF PROPER PRECAUTIONS ARE NOT MADE TO SHIELD
COAX FROM ALL WELDING PROCEDURES. IN ADDITION, COAX SHALL BE PUSHED AWAY FROM THE STRUCTURE
WHERE WELDING IS BEING PERFORMED.
5. CONTRACTOR SHALL EXERCISE CAUTION WHEN WELDING ON A GALVANIZED SURFACE. ADDITIONAL
SPLATTER AND SPARKS SHALL BE ANTICIPATED GIVEN THE PREVIOUSLY GALV. SURFACE. IF THE WELD
MATERIAL IS CONTAMINATED WITH ZINC IT DOES NOT PROVIDE A STRUCTURAL WELD. FUMES CREATED FROM
WELDING ON A PREVIOUSLY GALV. SURFACE CAN BE HAZARDOUS. PRIOR TO WELDING, ALL SURFACES SHALL
BE PROPERLY GROUND TO REMOVE GALVANIZING, SCALE, SLAG, RUST OR ANY OTHER MATERIAL TO
PREVENT PROPER WELDING.
6. ALL FIELD WELDS SHALL BE TOUCHED UP WITH TWO COATS OF COLD GALVANIZING PAINT (ZRC OR APPROVED
EQUIVALENT), INCLUDING THE INTERIOR OF MONOPOLE SHAFTS, WHERE ACCESS PERMITS, IN ANY AREAS
AFFECTED BY ANY WELDING. PHOTO DOCUMENTATION IS REQUIRED TO BE SUBMITTED TO THE MODIFICATION
INSPECTOR.
7. WATER SHALL BE ON SITE, OF ADEQUATE AMOUNT, AND AVAILABLE AT SHORT NOTICE AT ALL TIMES DURING
WELDING ACTIVITY. A MINIMUM OF 500 GAL. OF WATER SHALL BE PROVIDED. WATER SHALL BE CAPABLE OF
REACHING HEIGHT WHERE WELDING IS BEING PERFORMED. IN ADDITION, A MINIMUM OF SIX (6) 10 LB. CLASS
ABC MULTIPURPOSE FIRE EXTINGUISHERS FULLY CHARGED AND CAPABLE OF DISCHARGE WITHIN 30
SECONDS OF DETECTING A FIRE SHALL BE PROVIDED. FIRE EXTINGUISHERS SHALL BE STRATEGICALLY
LOCATED AROUND COMPOUND AND IN THE AIR (I.E. ON THE MAN LIFT WHERE WELDING IS BEING PERFORMED).
8. CLEAN OUT ALL DEBRIS TIN THE VICINITY OF WELDING OPERATIONS PRIOR TO WELDING.
9. THE CONTRACTOR SHALL TAKE COOLING EFFECTS OF THE WELDED MATERIAL INTO CONSIDERATION (I.E.
EXPANSION OF HOT MATERIAL AND CONTRACTION OF COOLED MATERIAL).
NA PRE-POUR REBAR INSPECTIONS A 3
RD PARTY VISUAL OBSERVATION OF THE EXCAVATION AND REBAR SHALL BE PERFORMED BEFORE PLACING THE
CONCRETE. A WRITTEN REPORT SHALL BE PROVIDED TO THE MI INSPECTOR FOR INCLUSION IN THE MI REPORT.
NA POST-INSTALLED REBAR AND/OR DOWEL INSPECTIONS PHOTOGRAPHIC DOCUMENTATION OF DRILL HOLE SIZES AND DEPTHS SHALL BE RECORDED BEFORE SETTING THE
POST INSTALLED REBAR AND DOWELS WITH EPOXY/GROUT.
NA CONCRETE COMP. STRENGTH & SLUMP TEST THE CONCRETE MIX DESIGN, SLUMP TEST, AND COMPRESSIVE STRENGTH TESTS SHALL BE PROVIDED AS PART OF
THE MI REPORT.
NA EARTHWORK: LIFT & DENSITY REPORT REPORT DETAILING SOIL COMPACTION TEST RESULTS TO BE INCLUDED IN THE MI REPORT.
NA MICROPILE/ROCK ANCHOR
MICROPILES AND ROCK ANCHORS SHALL BE INSPECTED BY A 3RD
PARTY. INSPECTION SHALL VERIFY ANCHOR SIZE,
STEEL GRADE, AND HOLE DEPTHS. PHOTOGRAPHIC DOCUMENTATION OF ALL MEASUREMENTS ALONG WITH THE
PULL TEST RESULTS SHALL BE INCLUDED IN THE MI REPORT.
NA HELICAL ANCHOR HELICAL INSTALLER SHALL SUBMIT FINAL SEALED HELICALS DESIGN, TORQUE LOGS, AND FINAL LOAD TEST
RESULTS TO BE INCLUDED IN THE MODIFICATION INSPECTION REPORT.
NA POST-INSTALLED ANCHOR ROD VERIFICATION
POST INSTALLED ANCHOR ROD VERIFICATION SHALL BE PERFORMED AND SHALL INCLUDE PHOTO VERIFICATION OF
HOLE DEPTH, HOLE CLEANOUT AND ROUGHENING, AND EPOXY LABELING. REPORT SHALL BE PROVIDED TO THE MI
INSPECTOR FOR INCLUSION IN THE MI REPORT.
X 3RD
PARTY FIELD CERTIFIED WELD INSPECTION A CWI SHALL CONDUCT A VISUAL INSPECTION OF ALL FIELD WELDS IN ACCORDANCE WITH AWS D1.1. CRITICAL
WELDS THAT REQUIRE ADDITIONAL TESTING ARE NOTED IN THE MODIFICATION DRAWINGS.
X ON-SITE COLD GALVANIZING VERIFICATION
THE GENERAL CONTRACTOR SHALL PROVIDE WRITTEN AND PHOTOGRAPHIC DOCUMENTATION TO THE MI
INSPECTOR VERIFYING THAT ANY ON-SITE COLD GALVANIZING WAS APPLIED PER MANUFACTURER
SPECIFICATIONS.
NA TENSION TWIST & PLUMB DELIVERABLES
THE GENERAL CONTRACTOR SHALL PROVIDE WRITTEN AND PHOTOGRAPHIC DOCUMENTATION TO THE MI
INSPECTOR VERIFYING THE STRUCTURE TWIST AND PLUMB CONDITION AS WELL AS THE WIRE TENSIONS (AS
REQUIRED). REPORT SHALL INCLUDE PRE-TENSION, PLUMB & TWIST RESULTS, POST-TENSION REPORT, POST
PLUMB AND TWIST REPORT, AND PHOTOS OF THE TENSION GAUGES FOR ALL GUY WIRES.
X GC AS-BUILT DRAWINGS
THE GENERAL CONTRACTOR SHALL SUBMIT A LEGIBLE COPY OF THE ORIGINAL DESIGN DRAWINGS EITHER STATING
"INSTALLED AS DESIGNED" OR NOTING ANY CHANGES THAT WERE REQUIRED AND APPROVED BY THE ENGINEER OF
RECORD. EOR/RFI FORMS APPROVING ALL CHANGES SHALL BE SUBMITTED.
NA BOLT PRE-TENSION VERIFICATION
TURN-OF-THE NUT METHOD IS THE DEFAULT METHOD FOR PRE-TENSIONING BOLTS. MATCH-MARKINGS SHALL BE
PRESENT ON EACH FASTENER FOR INSPECTION PURPOSES AND SHALL BE APPLIED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE RCSC SPECIFICATION. ALTERNATIVE PRE-TENSIONING METHODS ARE NOT ALLOWED
WITHOUT PRIOR EOR CONSENT.
POST-CONSTRUCTION
X CONSTRUCTION COMPLIANCE LETTER
A LETTER FROM THE GENERAL CONTRACTOR STATING THAT THE WORKMANSHIP WAS PERFORMED IN
ACCORDANCE WITH INDUSTRY STANDARDS AND THESE MODIFICATION DRAWINGS, INCLUDING LISTING ADDITIONAL
PARTIES TO THE MODIFICATION PROCESS.
NA POST-INSTALLED ANCHOR ROD PULL TESTS POST-INSTALLED ANCHOR RODS SHALL BE TESTED BY A PULL TEST INSPECTOR AND A REPORT SHALL BE
PROVIDED INDICATING TESTING RESULTS.
X PHOTOGRAPHS
PHOTOGRAPHS SHALL BE SUBMITTED TO THE MI INSPECTOR. PHOTOS SHALL DOCUMENT ALL PHASES OF THE
CONSTRUCTION. THE PHOTOS SHALL BE ORGANIZED IN A MANNER THAT EASILY IDENTIFIES THE EXACT LOCATION
OF THE PHOTO.
NA FOUNDATION SEALER PHOTOGRAPHIC DOCUMENTATION OF THE FOUNDATION SEALING SHALL BE INCLUDED IN THE MI REPORT.
NA BOLT HOLE INSTALLATION VERIFICATION REPORT
THE MI INSPECTOR SHALL VERIFY THE INSTALLATION AND TIGHTNESS OF 10% OF ALL NON PRE-TENSIONED BOLTS
INSTALLED AS PART OF THE MODIFICATION. THE MI INSPECTOR SHALL LOOSEN THE NUT AND VERIFY THE BOLT
HOLE SIZE AND CONDITION. THE MI REPORT SHALL CONTAIN THE COMPLETED BOLT INSTALLATION VERIFICATION
REPORT, INCLUDING THE SUPPORTING PHOTOGRAPHS.
X MI INSPECTOR REDLINE OR RECORD DRAWING(S) THE MI INSPECTOR SHALL OBSERVE AND REPORT ANY DISCREPANCIES BETWEEN THE CONTRACTOR'S REDLINE
DRAWING AND THE ACTUAL COMPLETED INSTALLATION.
*THE MI CHECKLIST SHALL BE REVIEWED PRIOR TO THE START OF CONSTRUCTION. ALL PARTIES TO THE MODIFICATION SHALL UNDERSTAND ALL REQUIREMENTS AND INSPECTION/DOCUMENTATION THAT IS
APPLICABLE TO THE SCOPE OF WORK THEY ARE PERFORMING. ERRORS ON THE MI CHECKLIST SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURE/STRUCTURE OWNER AND EOR AS SOON AS POSSIBLE.
MODIFICATION INSPECTION NOTES
GENERAL
1. THE MI IS AN ON-SITE VISUAL AND HANDS-ON INSPECTION OF STRUCTURE MODIFICATIONS INCLUDING A REVIEW OF
CONSTRUCTION REPORTS AND ADDITIONAL PERTINENT DOCUMENTATION PROVIDED BY THE GENERAL CONTRACTOR
(GC), AS WELL AS ANY INSPECTION DOCUMENTS PROVIDED BY 3RD PARTY INSPECTORS. THE MI IS TO ENSURE THE
INSTALLATION WAS CONSTRUCTED IN ACCORDANCE WITH THE MODIFICATION DRAWINGS; IN ACCORDANCE WITH
APPLICABLE INDUSTRY STANDARDS; AND AS DESIGNED BY THE ENGINEER OF RECORD (EOR).
2. NO DOCUMENT, CODE OR POLICY CAN ANTICIPATE EVERY SITUATION THAT MAY ARISE. ACCORDINGLY, THIS CHECKLIST
IS INTENDED TO SERVE AS A SOURCE OF GUIDING PRINCIPLES IN ESTABLISHING GUIDELINES FOR MODIFICATION
INSPECTION.
3. THE MI IS TO CONFIRM INSTALLATION CONFIGURATION AND WORKMANSHIP ONLY AND IS NOT A REVIEW OF THE
MODIFICATION DESIGN ITSELF, AND THE MI INSPECTOR DOES NOT TAKE OWNERSHIP OF THE MODIFICATION DESIGN.
THE MI INSPECTOR SHALL INSPECT AND NOTE CONFORMANCE/NONCONFORMANCE AND PROVIDE TO THE
STRUCTURE/STRUCTURE OWNER AND EOR FOR EVALUATION.
4. TO ENSURE THAT THE REQUIREMENTS OF THE MODIFICATION INSPECTION ARE MET, IT IS VITAL THAT THE GENERAL
CONTRACTOR (GC) AND THE MI INSPECTOR BEGIN COMMUNICATING AND COORDINATING AS SOON AS A PO OR
PAYMENT IS RECEIVED. IT IS EXPECTED THAT EACH PARTY WILL BE PROACTIVE IN REACHING OUT TO THE OTHER
PARTY. CONTACT LISTED ON THE TITLE SHEET SHALL BE CONTACTED IF SPECIFIC INSPECTOR CONTACT INFORMATION
IS NOT KNOWN.
FAILING INSPECTION CORRECTIONS
1. IF THE MODIFICATION INSTALLATION WOULD FAIL THE MODIFICATION INSPECTION (“FAILED MODIFICATION
INSPECTION"), THE GC SHALL WORK WITH MI INSPECTOR TO COORDINATE A REMEDIATION PLAN IN ONE OF TWO WAYS:
· CORRECT FAILING ISSUES TO COMPLY WITH THE SPECIFICATIONS CONTAINED IN THE ORIGINAL
MODIFICATION DRAWINGS AND COORDINATE A SUPPLEMENT MODIFICATION INSPECTION.
· OR, WITH STRUCTURE OWNER'S APPROVAL, THE GC MAY WORK WITH THE ENGINEER OF RECORD TO
RE-ANALYZE THE MODIFICATION/REINFORCEMENT USING THE AS-BUILT CONDITION.
SERVICE LEVEL COMMITMENT
1. THE FOLLOWING RECOMMENDATIONS AND SUGGESTIONS ARE OFFERED TO ENHANCE THE EFFICIENCY AND
EFFECTIVENESS OF DELIVERING AN MI REPORT:
· THE GC SHALL PROVIDE A MINIMUM OF 5 BUSINESS DAYS NOTICE, PREFERABLY 10, TO THE MI INSPECTOR
AS TO WHEN THE SITE WILL BE READY FOR THE MI TO BE CONDUCTED.
· THE GC AND MI INSPECTOR COORDINATE CLOSELY THROUGHOUT THE ENTIRE PROJECT.
· WHEN POSSIBLE, IT IS PREFERRED TO HAVE THE GC AND MI INSPECTOR ON-SITE SIMULTANEOUSLY FOR
ANY GUY WIRE TENSIONING OR RE-TENSIONING OPERATIONS.
· WHEN POSSIBLE, IT IS PREFERRED TO HAVE THE GC AND MI INSPECTOR ON-SITE DURING THE MI TO HAVE
ANY MINOR DEFICIENCIES CORRECTED DURING THE INITIAL MI. THEREFORE, THE GC MAY CHOOSE TO
COORDINATE THE MI CAREFULLY TO ENSURE ALL CONSTRUCTION FACILITIES ARE AT THEIR DISPOSAL WHEN
THE MI INSPECTOR IS ON SITE.
· IT MAY BE BENEFICIAL TO INSTALL ALL STRUCTURE MODIFICATIONS PRIOR TO CONDUCTING THE
FOUNDATION INSPECTIONS TO ALLOW THE FOUNDATION AND MODIFICATION INSPECTION(S) TO COMMENCE
WITH ONE SITE VISIT.
REQUIRED PHOTOS
1. BETWEEN THE GC AND THE MI INSPECTOR THE FOLLOWING PHOTOGRAPHS, AT A MINIMUM, ARE TO BE TAKEN AND
INCLUDED IN THE MI REPORT:
· PRE-CONSTRUCTION GENERAL SITE CONDITION
· PHOTOGRAPHS DURING THE REINFORCEMENT MODIFICATION CONSTRUCTION/ERECTION AND INSPECTION
·· RAW MATERIALS
·· PHOTOS OF ALL CRITICAL DETAILS
·· FOUNDATION MODIFICATIONS
·· WELD PREPARATION
·· BOLT INSTALLATION
·· FINAL INSTALLED CONDITION
·· SURFACE COATING REPAIR
· POST CONSTRUCTION PHOTOGRAPHS
·· FINAL INFIELD CONDITION
· ANY OTHER PHOTOS DEEMED RELEVANT TO SHOW COMPLETE DETAILS OF THE MODIFICATIONS.
2. PHOTOS OF ELEVATED MODIFICATIONS TAKEN ONLY FROM THE GROUND SHALL BE CONSIDERED INADEQUATE.
2/15/22
JOB NO.
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
REV. DATE DESCRIPTION
PROJECT MANAGER APPROVED BY
ENGINEER DESIGNER
CJS
CARMEL DR
650 E CARMEL DR.
CARMEL, IN 46032
JRS MJS
TP
2022723.16.1637.03
DESIGN DRAWINGS
PREPARED FOR:
CARMEL DR
FA #: 10023984
CLIENT #: IN0128
0 2/15/22 INITIAL RELEASE
T-01
ERICSSON
GPD GROUP, INC. ®
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
TITLE SHEET
2/15/2022
-
-
-
CLIENT CONTACT:
(314) 706-0550
INDIANAPOLIS, IN 46204
55 MONUMENT CIRCLE
MICHAEL SIVORE
ENGINEER CONTACT:
FOR QUESTIONS PLEASE EMAIL:
GPDMODS@GPDGROUP.COM
(330) 572-2100
AKRON, OH 44311
520 SOUTH MAIN STREET, SUITE 2531
GPD GROUP, INC.