HomeMy WebLinkAboutS200.0 - Second Level9'0" CEILING HEIGHT UNLESS OTHERWISE NOTED.
SECOND LEVEL FLOOR PLAN SYSTEM - 50LBS. P.S.F. TOTAL FLOOR LOAD
2. GENERAL NOTES
BEARING WALLS
1. MATERIALS LEGEND - NEW CONSTRUCTION
CONSTRUCTION LEGEND
FRAME WALLS
BRICK VENEER
2x10 BLOCKING
FLUSH w/ INSIDE
FACE OF STUDS
8"
4. WINDOW/DOOR HEAD FRAMING DETAIL (TYP.)6"INTERIOR DIMENSIONS TO FACE OF STUD WALLS
EXTERIOR DIMENSIONS TO FACE OF SHEATHING
3. DIMENSION NOTES
LVL HEADER (VERIFY
SIZING w/ LUMBER
MANUFACTURER)
ENTRY
(OPEN TO BELOW)
GREAT ROOM
(OPEN TO BELOW)
DOWN
23 RISERS
RAILING
LANDING
- 9'-0" CEILING HEIGHT
BATHROOM
- 9'-0" CEILING HEIGHT
CLOSET
SHOWER
SIT DOWN
VANITY
W.C.
L.
INTERIOR TRANSOM
HVAC/ STORAGE - 9'-0" CEILING HEIGHTBATHROOMSHOWER
L.
W.C.
STEPS TO
LOFT AREA
- OPEN CEILING w/ LOFT
AREA ABOVE
BEDROOM #2
- 9'-0" CEILING HEIGHTCLOSET- 9'-0" CEILING HEIGHT
BEDROOM #3
L.
W.C.
THE ROOM
- 9'-0" CEILING HEIGHTCLOSETSHOWER
PIVOTING
SHELF
PIVOTING
SHOE SHELF
- 9'-0" CEILING HEIGHT
BATHROOM
- OPEN CEILING
LOUNGE AREA
- 9'-0" CEILING HEIGHT
GUEST BEDROOM
TALL OPEN CEILING IN
GARAGE & FITNESS
- NO STORAGE ABOVE
GARAGE AREA
FITNESS
- TALL CEILING FOR CLIMBING WALL
SLOPE
CEILING
5x5x14"STL. COL.3-PLYx24 FLUSH
LVL HDR. W/JST. HANGERS
6 PLY SOLID
BLOCKING
6 PLY SOLID
BLOCKING
31
2x31
2x14"
STL. COL.
VELUX 306
SKYLIGHTS
W18x40# FLUSH
STL.BEAM W/JST.
HANGERS
HALLWAY
UDGRT 2847UDGRT 2847
UCA 3072-2 UCA 3072-2 UCA 3072-2
UCA 3072-2 UCA 3072-2 UCA 3072-2
UCA 3660-2 UCA 3660-2 UCA 3660-2
UCA 3664UCA 3660-2UCA 3664-2UCA 3264-36" 14'-1" 512"11'-2 12" 5 12" 14'-1" 6"
7'-612"13'-114" 13'-114" 7'-612" 5'-7" 8'-0" 8'-0" 6'-112"
41'-312" 27'-812"7'-514"9'-1134"5'-934"13'-212"9'-134"17'-5"10'-0"28'-2"13'-4"23'-4"9'-1"31'-10"8'-0"6'-1" 8'-0 1 2" 8'-0 12" 6'-1"
1'-1078" 1'-1078"1'-107 8" 1'-1078"
7'-638" 3'-93 4" 6'-1178" 6'-8 18 " 3'-934" 6'-818" 1'-2516"11'-1012" 6" 20'-912"
6" 8'-912"5 12"8'-4 12" 512" 14'-1" 6"
6"26'-512"1'-3" 5'-1"5 12"12'-4" 512"
2'-912"3'-212" 6" 6'-912" 512" 4'-1"512 " 6'-6"512" 4'-1" 5 12 " 9'-112" 512" 4'-1" 512" 7'-1"
4'-212" 6'-0"VOID3'-0"4'-1" 4'-7" 512 " 1'-512" 7'-112" 2'-512"
3'-0"
4'-7" 512 "3'-4" 5 12" 4'-1" 512" 4'-3"
2'-0"
2'-1" 512"22'-2"512" 2'-1" 6"
1'-1012" 6"5'-512"512"7'-618"9'-7"7'-618"914"7'-512"512"4'-1"512"4'-0"512"6'-1"512"16'-1112"6"1'-1012"512"6'-1"512"2'-112"512"16'-1112"13'-10"512"4'-1"512"4'-1"512"4'-7"512"10'-1"512"6'-7"512"3'-9"512"4'-1"1'-212"6"13'-4"3'-11"6'-2"1'-4"2'-3"512"3'-0"
2'-8"
2'-8"
3'0"x7'
0"3'0
"x7'0
"
3'0"x7'0"
3'0
"
x
7
'
0
"3'0"x7'0"PKT. DR.3'0"x7'0"
PKT. DR.
3'0"x7'0"
PKT. DR.
3'0"x7 '0"
3'0"x7'
0"3'0
"x7'0
"3'0
"x7
'0"3'0"x7
'0"2'-612"14'-1012"17'-10"5 12"4'-612"512"6'-512"CABINETS
8'-7" 8'-7" 8'-7" 8'-7"
17'-2" 40'-11" 17'-2"
VOIDVOID
412"
TYPICAL
1'-1"BA
8
UCART 5150 UCART 5150
8'-7"
UCART 5150
RUBBER
ROOF2:12PITCH1
9
1
9
2
9
3
9
2
9
3
9
4
9
4
9
5 5
10 10
9
6
9
6
9
10
9
10
8
10
8
7
10
7
10
10
12
10
12
Date: 12-03-2021Plan number #210817Designed For:Craig House llc.H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design4SCALE: 1/4"=1'-0"SECOND LEVEL FLOOR PLAN SHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction
of this work, its technical aspects or creative content without the express written consent
of H. G. McCullough Designers, Inc. This work is fully protected by copyright under
U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction details06/29/22