Loading...
HomeMy WebLinkAboutA010.3 - SectionsDate: 12-03-2021Plan number #210817Designed For:Craig House llc.H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720- Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design* Seal all joints between dissimilar materials. * Metal flashing installed to all applicable areas * All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall flashing, etc.) shall be lapped to shed water to the outside of the building envelope * Ridge vents as per contractor/manufacturer specifications * 30# Asphalt sat. felt *7 16" Decking * All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per manufacturer specifications. * Gutter and downspout locations and install specifications. * Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to resist wind and seismic forces. * Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications. * Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications. * Flashing installed to wall/roof connections. * Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above). * Door flashing below the threshold. * Flashing and water proofing top of chimney structure before installing chimney cap. * Chimney exterior and interior metal flashing * Baffle stop insulation installed properly, with correct R-factor. * Low slope roofing material installed as per manufacturer specifications. * Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications. * Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor. * Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials. 3-PLYx1178LVL HDR. 2-PLYx117 8 LVL HDR. HER CLOSET MASTER BATH 2-PLYx117 8 FLUSH LVL HDR. W/JST. HANGERS 3'-1012"1'-234"12'-118"14" FL. JST @ 16" O.C. 3 4" OSB SUB. FL. 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL R-19 INSUL. BATTS OR EQUAL DRAFT STOP 1 FRAMING SECTION 12 7 PITCH 1'-712"11'-41316"1'-6" 18'-5" 18'-5"312" 1'-6"312" 2x8 RAFT E R S 1 6 " O. C. 2x8 CLG. JST @ 16" O.C. 12" INSUL. BATTS R-38 4'-0"POUREDCONCRETE WALL HEIGHTASPHALT SHINGLES 30# ASPHALT SAT. FELT 7 16" DECKING AIR SPACE BRICK VENEER 30# ASPHALT SAT. FELT OR EQUAL 1/2" O.S.B. SHEATHING WATERPROOFING AS SPECIFIED BY GENERAL CONTRACTOR GRAVEL FILL WRAP WASH GRAVEL BACKFILL w/LANDSCAPE FELT MAT'L. 24"x10" THK. CONC. FTG W/(2)#4 BARS CONT. 4" DIA. PERF PIPE w/SOCK 2x4 BRACING 32" O.C. SEAT CUT SEAT CUT 3" (MIN.) CONC. SLAB SLOPED TO DRAIN OR SUMP PIT VERIFY w/ CONTR. 1 3 4" X 1178" RIDGE BEAM TOP OF RIDGE BEAM 117 8" JST @ 16" O.C.218"6 MIL POLYETHYLENE VAPOR BARRIER SHOWER 1A 12 EAVE DETAILS INTERIOR AND EXTERIOR METAL FLASHING (AS PER CONTRACTOR) BOLT 31 2"x31 2"x 5 16" STL. ANGLE TO 2x6 RIBBON BOARD THAT FOLLOWS THE SLOPE OF THE ROOF w/ METAL FLASHING (AS A PER CONTRACTOR) BA BRICK ANGLE DETAIL NOT TO SCALE 2-PLYx11 7 8 FLUSH LVL HDR. W/ JST. HANGERS 2-PLYx117 8 LVL HDR. 2-PLYx117 8 LVL HDR. HIS CLOSET MASTER BEDROOM 3'-1012"1'-234"12'-118"14" FL. JST @ 16" O.C. 3 4" OSB SUB. FL. DRAFT STOP 2 FRAMING SECTION 1'-6" 312"21'-7" 21'-7"312" 1'-6"1'-712"13'-21516"2x8 CLG. JST @ 16" O.C. 12" INSUL. BATTS R-38 2x4 BRACING 32" O.C. 12 7PITCH SEAT CUT SEAT CUT 2x8 RA F T E R S 16" O. C. TOP OF RIDGE BEAM 2x4 BRACING 32" O.C. THINSET BRICK VENEER 10" CONC. WALL w/ VERT. #5 REBARS 14" o.c. & #5 HORZ. REBARS 12"o.c. 3" (MIN.) CONC. SLAB SLOPED TO DRAIN OR SUMP PIT VERIFY w/ CONTR. 6 MIL POLYETHYLENE VAPOR BARRIER12'-10"BOT. OF LOOKOUTS 6 FRAMING SECTION FITNESS GEAR AREA WINE CASE STORAGE11'-538"2'-0"20'-258"15'-512"11'-838"2-PLYx117 8 FLUSH LVL RIDGE. W/JST. HANGERS 2x8 RAFTE R S 16 " O.C. 2x8 CLG. JST @ 16" O.C. 2x6 CLG. JST @ 16" O.C. 12 12 PITCH 12 6 PITCH 12 12PITCH 2 x 8 R A F T E R S 1 6 " O. C . 13 4" X 24" RIDGE BEAM 1'-158"4'-51116"8'-11516"1'-6" 3 12 " 3'-7716" 17'-11916"10'-11"312" 1'-6" SEAT CUT SEAT CUT AIR SPACE BRICK VENEER 30# ASPHALT SAT. FELT OR EQUAL 1/2" O.S.B. SHEATHING STONE VENEER DRAFT STOP 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB W/ 6x6 #10 WWF FULL THK FRICTION FIT FIBERGL INSUL. BIBS R-13 2x6 STUDS 16" O.C. w/ 12" DRYWALL 12" INSUL. BATTS R-38 INSUL. BAFFLE STOP TOP OF RIDGE BEAM SLOPE MASONRY SILL 6'-0"13'-1112"BOT. OF LOOKOUTS 6A 9 EAVE DETAILS 2'-0"TOP OF MAIN LEVEL SUB FL.1'-634"FULL THK FRICTION FIT FIBERGL INSUL. BIBS R-13 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL 6 MIL POLYETHYLENE VAPOR BARRIER INSUL. BATTS 2" RIGID INSUL. 12"x18" GALVANIZED ANCHOR BOLT 22'-7" 3 FRAMING SECTION W18x40# FLUSH STL.BEAM W/JST. HANGERS 3-PLYx24 FLUSH LVL HDR. W/JST. HANGERS W24x62# STL.BEAM W/1 2"x101 4 STEEL PLATE WELDED TO BOTTOM FLANGE WITH STIFFNERS 1'-234"3'-1012"1'-6" 312"15'-7" 15'-7"3 12" 1'-6" SEAT CUT SEAT CUT 2x8 RA F TE R S 16" O. C. 10'-712"51 2" 1'-4 12"12'-2"112"112"SLOPESTEP12 7PITCH 12 1PITCH 3-PLYx18 LVL HDR. TOP OF RIDGE BEAM 1'-9716"9'-81516"2x4 BRACING 32" O.C.112"2916"SLOPESTEPGRAVEL FILL NOTE: EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR. GRAVEL FILL NOTE: EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR. 14" FL. JST @ 16" O.C. 3 4" OSB SUB. FL. 2-PLYx117 8 LVL HDR. 2-PLYx117 8 LVL HDR. 2x8 CLG. JST @ 16" O.C. 2x6 CLG. JST @ 16" O.C.11'-638"1'-6"2x6 RAFTERS @ 16" O.C.8'-0"1'-9716"BRICK PAVERS LAID ON 4" CONC. SLAB W/ 6x6 #10 WWF STONE PAVERS LAID ON 4" CONC. SLAB W/ 6x6 #10 WWF ASPHALT SHINGLES 30# ASPHALT SAT. FELT 7 16" DECKING TOP OF SECOND LEVEL SUB FLOOR ICE SHIELD UNDER LAYMENT OR EQUAL w/ RUBBER ROOF MEMBRANE AS PER CONTR. 3" (MIN.) CONC. SLAB SLOPED TO DRAIN OR SUMP PIT VERIFY w/ CONTR. 3-PLYx18 LVL HDR. 1'-118"NOTE: EXTERIOR WALL, ROOF FLASHING & WATERPROOFING AS PER CONTR.12'-10"BOT. OF LOOKOUTS23'-578"BOT. OF LOOKOUTS 3'-5"914"STEEL LINTEL AS SIZED BY MASONRY CONTRACTOR STEEL LINTEL AS SIZED BY MASONRY CONTRACTOR 21'-578"1'-118"1'-3" 3B 12 EAVE DETAILS 3A 12 EAVE DETAILS FULL THK FRICTION FIT FIBERGL INSUL. BIBS R-13 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL 6 MIL POLYETHYLENE VAPOR BARRIER 3 4" OSB SUB. FL. 14" FL. JST @ 16" O.C. 4 FRAMING SECTION10'-0"2-PLYx117 8 LVL HDR. W16x40# STL.BEAM KITCHEN CLUB ROOMDINING AREA BATHROOM SHOWER HVAC/ STORAGE BEDROOM #2 9'-118"1'-434"12'-118"1'-234"9'-912"VELUX 306 SKYLIGHTS 2x 8 RA F T E RS 16" O. C . 12 73 8 PITCH 8'-118"10" CONC. WALL w/ VERT. #5 REBARS 14" o.c. & #5 HORZ. REBARS 12"o.c.4" CONC. SLAB W/ 6x6 #10 WWF 4" (MIN.) GRAVEL FILL W14x26# STL.BEAM W/1 2"x101 4 STEEL PLATE WELDED TO BOTTOM FLANGE WITH STIFFNERS 12 7 PITCH BA 8 3-PLYx117 8 LVL HDR.11'-91116"1'-81 2" 512" 5'-10 12" SEAT CUT 10'-078"2x4's 12 12 PITCH 1'-6" 312" SEAT CUT 4'-0"POUREDCONCRETE WALL HEIGHT1'-812"1'-6"4316"27'-10316" 2x4's INSUL. BAFFLE STOP 17'-91116"TOP OF RIDGE BEAM 2x4'S @ 16" O.C. 34" OSB SUB. FL. 16" FL. JST @ 16" O.C. 91 4" FL. JST @ 16" O.C.10"2x4'S @ 16" O.C.2x8 RAFTERS 16" O.C.2x12 RAFT ERS 1 6" O.C. WATERPROOFING AS SPECIFIED BY GENERAL CONTRACTOR GRAVEL FILL WRAP WASH GRAVEL BACKFILL w/LANDSCAPE FELT MAT'L. 24"x10" THK. CONC. FTG W/(2)#4 BARS CONT. 4" DIA. PERF PIPE w/SOCK10'-0"POURED CONCRETE WALL HEIGHT13 4" X 1178" RIDGE BEAM SLOPE MASONRY SILL NOTE: EXTERIOR WALL, ROOF FLASHING & WATERPROOFING AS PER CONTR. LAY BRICK UP AND AROUND FRAMING VERIFY @ SITE 1'-91116"5A 9 EAVE DETAILS 4A 12 EAVE DETAILS 4B 12 EAVE DETAILS INSUL. BAFFLE STOP CLOSE CELL SPRAY FOAM INSULATION VERIFY w/ CONTR. 9SCALE: 1/4"=1'-0" FRAMING SECTIONS Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 06/29/22