Loading...
HomeMy WebLinkAboutA010.6 - SectionsDate: 12-03-2021Plan number #210817Designed For:Craig House llc.H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720- Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design* Seal all joints between dissimilar materials. * Metal flashing installed to all applicable areas * All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall flashing, etc.) shall be lapped to shed water to the outside of the building envelope * Ridge vents as per contractor/manufacturer specifications * 30# Asphalt sat. felt *7 16" Decking * All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per manufacturer specifications. * Gutter and downspout locations and install specifications. * Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to resist wind and seismic forces. * Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications. * Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications. * Flashing installed to wall/roof connections. * Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above). * Door flashing below the threshold. * Flashing and water proofing top of chimney structure before installing chimney cap. * Chimney exterior and interior metal flashing * Baffle stop insulation installed properly, with correct R-factor. * Low slope roofing material installed as per manufacturer specifications. * Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications. * Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor. * Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials. 5 8" X 7 1 4" LP FASCIA TRIM 5 8" SOFFIT TRIM 5 8" X 1 1 2" LP TRIM BAND 5 8" X 9 1 4" LP FRIEZE TRIM TRIMMED @ SITE 2X4'S METAL EDGING EAVE DETAIL 1A GUTTER 312"1'-6" SEAT CUT SIMPSON SEISMIC & HURRICANE TIES OR EQUAL 1'-712"SCALE: 1"=1'-0"878"SIMPSON SEISMIC & HURRICANE TIES OR EQUAL METAL EDGING GUTTER 5 8" X 7 1 4" LP FASCIA TRIM 5 8" SOFFIT TRIM 5 8" X 1 1 2" LP TRIM BAND 5 8" X 9 1 4" LP FRIEZE TRIM TRIMMED @ SITE 5A EAVE DETAIL 2X4'S SCALE: 1"=1'-0" 33 4" 1'-6" SEAT CUT 1'-614"SIMPSON SEISMIC & HURRICANE TIES OR EQUAL GUTTER 5 8" X 7 1 4" LP FASCIA TRIM 5 8" SOFFIT TRIM 5 8" X 1 1 2" LP TRIM BAND 5 8" X 9 1 4" LP FRIEZE TRIM TRIMMED @ SITE 4A EAVE DETAIL 2X4'S 4316" 1'-6" SEAT CUT SCALE: 1"=1'-0"412"1'-4"718"SIMPSON SEISMIC & HURRICANE TIES OR EQUAL METAL EDGING GUTTER 5 8" X 7 1 4" LP FASCIA TRIM 5 8" SOFFIT TRIM 5 8" X 1 1 2" LP TRIM BAND 5 8" X 9 1 4" LP FRIEZE TRIM TRIMMED @ SITE 6A EAVE DETAIL 2X4'S 312" 1'-6" SEAT CUT SCALE: 1"=1'-0"1'-6"312" 1'-6" SEAT CUT SIMPSON SEISMIC & HURRICANE TIES OR EQUAL 5 8" X 7 1 4" LP FASCIA TRIM METAL EDGING GUTTER 5 8" SOFFIT TRIM 5 8" X 3 1 2" LP TRIM BAND 5 8" X 11 1 4" LP FRIEZE TRIM TRIMMED @ SITE 2X4'S 3-PLYx9 1 4 LVL. HDR. LIMESTONE SOLDIER COURSE STEEL LINTEL AS PER MASONRY CONTRACTOR 3B EAVE DETAIL 1 1 16" X 1 3 4" LP BACK BAND1'-9716"1078"5 8" X 7 1 4" LP FASCIA TRIM METAL EDGING GUTTER 5 8" SOFFIT TRIM 5 8" X 3 1 2" LP TRIM BAND 5 8" X 7 1 4" LP FRIEZE TRIM TRIMMED @ SITE 2X4'S 1 1 16" X 1 3 4" LP BACK BAND 5 8" X 11 1 4" LP FRIEZE TRIM TRIMMED @ SITE 3-PLYx18 LVL HDR. 3'-5"914"8"512" 1'-412" SEAT CUT 3A EAVE DETAIL SCALE: 1"=1'-0" NOTE: EXTERIOR WALL, ROOF FLASHING & WATERPROOFING AS PER CONTR. LAY BRICK UP AND AROUND FRAMING 2X6'S 16" o.c. 2X6'S 16" o.c. 12 1PITCH ICE SHIELD UNDER LAYMENT OR EQUAL w/ RUBBER ROOF MEMBRANE AS PER CONTR. 8'-012" 412" WINDOW SILL AND WINDOW FLASHING AS PER CONTRACTOR 1'-4" 2'-9"4'-7516"8316"718"METAL RAILING DESIGN AS PER CLIENTS 5 8" X 7 1 4" LP FASCIA TRIM METAL EDGING 5 8" SOFFIT TRIM 5 8" X 1 1 2" LP TRIM BAND 5 8" X 11 1 4" LP FRIEZE TRIM TRIMMED @ SITE LIMESTONE SOLDIER COURSE EAVE DETAIL 4B STEEL LINTEL AS PER MASONRY CONTRACTOR GUTTER 512"1'-812" SEAT CUT 1'-75 8" SIMPSON SEISMIC & HURRICANE TIES OR EQUAL 3-PLYx117 8 LVL HDR. SCALE: 1"=1'-0"1'-21116" W14x26# STL.BEAM W/1 2"x101 4 STEEL PLATE WELDED TO BOTTOM FLANGE WITH STIFFNERS 3'-93 4 " SKYLIG H T R . O . 2X12'S 16" o.c . VELUX 306 SKYLIGHTS 3116"5 8" X 7 1 4" LP FASCIA TRIM METAL EDGING 5 8" X 1 1 2" LP TRIM BAND 5 8" X 7 1 4" LP FRIEZE TRIM TRIMMED @ SITE EAVE DETAIL 5B GUTTER 312 "1'-512" SEAT CUT SIMPSON SEISMIC & HURRICANE TIES OR EQUAL 5 8" SOFFIT TRIM 5 8" SOFFIT TRIM 1'-10"458"1'-4" 2-PLYx14 LVL HDR.2" W14x26# STL.BEAM W/1 2"x81 2 STEEL PLATE WELDED TO BOTTOM FLANGE WITH STIFFNERS 1'-3" 2X4'S SCALE: 1"=1'-0" 11SCALE: 1/4"=1'-0" FRAMING SECTIONS/EAVE DETAILS Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 06/29/22