Loading...
HomeMy WebLinkAboutE001.0 - Lower Level ElectricalSTUDS 12" AIRSPACE CONCRETE WALL CONCRETE BLOCK WALLS CONSTRUCTION LEGEND FRAME WALLS 1. MATERIALS LEGEND BEARING WALLS CONCRETE WALLS SPW TYP. SOUNDPROOF WALL DETAIL 2x8 TOP & BOT. PLATE 2x6 STUDS STAGGERED 16" O.C. SOUNDPROOF INSUL. BATTS WEAVED AROUND STUDS INTERIOR DIMENSIONS TO FACE OF STUD WALLS EXTERIOR DIMENSIONS TO FACE OF SHEATHING STUD WALLS ALONG MASONRY FOUNDATION WALLS 2. DIMENSION NOTES GRAVEL FILL UNEXCAVATED GRAVEL FILL UNEXCAVATED WINDOW WELL UP 19 RISERS DISPLAY SHELFWINE CELLAR BEAM BEAM UNFINISHED BASEMENT HVAC AND STORAGE CRAWLSPACE CRAWLSPACE FINISHED STORAGE LIVING AREA - STONE WALLS - WOOD CEILING GRAVEL FILL UNEXCAVATED GRAVEL FILL UNEXCAVATED 3'0 " x 7 ' 0 "3'0"x7'0"1'8"x7'0" SIDELIGHT 1'8"x7'0" SIDELIGHT 312x312x14" STL. COL.THIN SETVENEERUCA3248 36" ACCESS3'0"x7' 0" 7'5"x7'0" OPENING THIN SETVENEER WINE CASE STORAGE GRAVEL FILL UNEXCAVATED BEAM BEAM3'0 "x7 '0 " COUNTER FULL HEIGHT REF. SUMP SUMP EJECT. W.H. W.S. W.S. R/O FURN.FURN. ERVDEHUM.WINE UNIT SUMP HUMID.HUMID. 200A PANEL200A PANELWTR. MANI. A/V A/V R R R R R R R R R R R R R R RR R R R R R R R R RR RR R B A/V A/V A/V A/V REF R/O SUMP SUMP SUMP FURN.FURN.GFCIGFCIWH WS WS FLOOR TV K K K KK K K K K K K K SSHUMIDIFIER HUMIDIFIERDEHUMIDIFIER ERV WINE UNIT L L L L L LL L CO2 S Date: 12-23-2021Plan number #210817Designed For:Craig House llc.H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720- Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignE2SCALE: 1/4"=1'-0"LOWER LEVEL ELECT. PLAN-HOUSE Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 06/29/22