HomeMy WebLinkAboutGN004 - 241FA* Seal all joints between dissimilar materials. * Metal flashing installed to all applicable areas * All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall flashing, etc.) shall be lapped to shed water to the outside of the building envelope * Ridge vents as per contractor/manufacturer specifications * 30# Asphalt sat. felt * 5 8" Decking * All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per manufacturer specifications. * Gutter and downspout locations and install specifications. * Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to resist wind and seismic forces. * Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications. * Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications. * Flashing installed to wall/roof connections. * Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above). * Door flashing below the threshold. * Flashing and water proofing top of chimney structure before installing chimney cap. * Chimney exterior and interior metal flashing * Baffle stop insulation installed properly, with correct R-factor. * Low slope roofing material installed as per manufacturer specifications. * Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications. * Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor. * Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials. GENERAL NOTES, AS PER CONTRACTOR Date: 06-15-2021Plan number #210113Designed For:Jim & Chris ThomasH. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design 4 FRAMING SECTION KITCHEN LIVING ROOM SCREENED IN PORCH 4'-0"3'-1112"1'-234"10'-118"POURED CONCRETE WALL HEIGHT2X12 CEILING JOIST 16" O.C. 14 JST @ 16" O.C. 34" PLYWOOD SUB FLOOR 2" (MIN.) CONC. SLAB SLOPED TO DRAINAGE AS PER CONTR. 6 MIL POLYETHYLENE VAPOR BARRIER 12 PITCH 10 12 PITCH 61 2 1'-612" 458"17'-818" 312"10'-014"9'-113 4" 312"18'-234" 412" 1'-612" 10'-7" 7'-1316"12'-0316"6'-2916" 1134"6'-5116"14'-538"24"x10" THK. CONC. FTG W/(2)#4 BARS CONT. NOTE: EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR.15'-158"12" INSUL. BATTS R-38 2x8 RA F T E R S 2 4 " O . C . 2x 8 R A F T E R S 2 4 " O . C. 4" DIA. PERF PIPE w/SOCK GRAVEL FILL WATERPROOFING AS SPECIFIED BY GENERAL CONTRACTOR10'-214"BOT. OF LOOKOUT 5/8" DECKING 30# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE ASPHALT SHINGLES 2" RIGID INSULATION SEAT CUT SEAT CUT SEAT CUT SEAT CUT TOP OF RIDGE BEAM 2x4 BRACING 32" O.C.1134"22'-101316"NOTE: SLOPED BRICK SILL, EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR. 12" INSUL. BATTS R-38 WINDOW HEAD DETAIL VERIFY w/ OWNER & CONTR. NOTE: SLOPED BRICK SILL, EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR. 11 7 8 I JST @ 16" O.C. 2X8 CEILING JOIST 16" O.C. 4"MASONRY LEDGE W10x17# STL. BEAM 5 FRAMING SECTION FLUSH 2-PLYx1178 LVL HDR. w/ METAL JST. HANGERS BATHROOM BEDROOM #3 GALLERY HALL 4'-0"POURED CONCRETE WALL HEIGHT10'-0"POURED CONCRETE WALL HEIGHTMASTER CLOSET GEAR AREA 9'-912"1'-234"10'-118"1'-058"9'-118"8'-118"2x8 JOIST 16" O.C. 14 JST @ 16" O.C. 34" PLYWOOD SUB FLOOR 4 MIL POLYETHYLENE VAPOR BARRIER 4" (MIN.) GRAVEL FILL 4" CONC. SLAB W/ 6x6 #10 WWF 12 PITCH 10 12 PITCH7 12" INSUL. BATTS R-38 11 7 8 I JST @ 16" O.C. 2-PLYx91 4 LVL HDR. 12 PITCH 5 2x 8 R A F T E R S 2 4 " O . C. 2x8 RAFT E R S 2 4" O. C . INSUL. BAFFLE STOP 1'-2"658" 17'-4316" 11'-414" 31516"10'-812"312"4'-5" 312" 1'-434" 31 2" SEAT CUT SEAT CUT SEAT CUT SEAT CUT 2x6 JOIST 16" O.C.1'-078"19'-4916"TOP OF RIDGE BEAM 9'-312"1'-712"2x6 RAFT E R S 24" O . C.834"10'-7"INSUL. BATTS 2x4 BRACING 32" O.C. 2x8 JOIST 16" O.C.5"1"STEPSLOPENOTE: SLOPED BRICK SILL, EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR.1038"7'-91316"BOT. OF RAFTER CUT 2X4 PLATE 6'-71116"10'-214"BOT. OF LOOKOUTS 934" 2" (MIN.) CONC. SLAB SLOPED TO DRAINAGE AS PER CONTR. 4"MASONRY LEDGE 3 CAR GARAGE STORAGE 7 FRAMING SECTION 6 MIL POLYETHYLENE VAPOR BARRIER 12 PITCH10 16 JST @ 16" O.C. TOP OF MAIN LEVEL SUB FL. 2" RIGID INSULATION 4" CONC. SLAB W/ 6x6 #10 WWF 1'-2" 4116"12'-7716" 12'-7716"4116" 1'-2" SEAT CUT SEAT CUT 10'-114"1'-512"11'-278"31 2" NAILER INSUL. BAFFLE STOP 2x8 R A F TER S 24" O.C. 2x6 JOIST 16" O.C.3'-0"30# ASPHALT SAT. FELT OR EQUAL 1/2" O.S.B. SHEATHING BRICK VENEER 1" MIN. AIR SPACE TOP OF RIDGE BEAM 1 34" X 11 78" RIDGE BEAM 2X4 PLATE 2X4 PLATE NOTE: SLOPED BRICK SILL, EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR. 4"MASONRY LEDGE SCALE: 1/4"=1'-0" FRAMING SECTIONS "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 10Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER 06/29/22