Loading...
HomeMy WebLinkAboutS001 - 241FA20"x10" THK. CONC. FTG W/(2)#4 BARS CONT. 36'-8"35'-8" 18'-4" 12'-8"8'-4" 17'-0"22'-4" 1'-4" 4'-6"4'-6" 2'-0" 1'-8"26'-8"13'-0"12'-4"6'-0" 43'-212" 18'-11" 19'-1012" 12'-8" 8" 10" 18'-412" 20'-7"19'-012"9'-4" 14'-8"4'-8"5'-4"11'-0"2'-8"18'-0"30'-8"24'-0"3'-0"3'-8"3'-8"3'-0"GRAVEL FILL UNEXCAVATED GRAVEL FILL UNEXCAVATED CRAWL SPACE GRAVEL FILL UNEXCAVATED W10x30# STL. BEAM W10x30# STL. BEAM 10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE10" POURED CONCRETE10" POURED CONCRETE10" POURED CONCRETE10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE24"x12" THK. CONC. FTG W/(2)#4 BARS CONT. 24"x12" THK. CONC. FTG W/(2)#4 BARS CONT. 24"x12" THK. CONC. FTG W/(2)#4 BARS CONT. 24"x12" THK. CONC. FTG W/(2)#4 BARS CONT. 8 11 1 8 2 9 1 8 2 9 3 8 10 4 5 10 5 10 7 10 7 10 11 8 9 11 FOOTING DETAIL 1 BFOOTING DETAIL 1 D FOOTING DETAIL 1 D BEAM PKT.8"13'-4"17'-4"10" POURED CONCRETE10" POURED CONCRETE10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE 8'-0"3'-8"10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE 10" POURED CONCRETE1'-414" 3'-3"13'-834" 1'-8" 3'-6" 16'-3"2'-0" 9'-3"4'-0" M.O. M.O. M.O.2'-0"3'-4"2'-0"3'-2316"4'-0"3'-978"10" POURED CONCRETE 10" POURED CONCRETE10" POURED CONCRETE10'-5" 6'-3" 70'-0" 8'-0" 1'-4" 6'-8" 41'-358" 14'-438"15'-758"8"3'-2"12'-814"12'-0" 15'-1014" 9'-512" 18'-4" 1'-8" 31 2x31 2x14" STL. COL. 31 2x31 2x14" STL. COL.3'-8"15'-21516"81316"4'-612"5'-934"5'-034" 23'-758"6'-118"4'-614"5'-014"6" POURED CONCRETE 31 2x31 2x14" STL. COL. 31 2x31 2x 14" STL. COL. 634" 634"16'-1012"634"712"7" 19'-5"7" 18'-4"10'-0"11'-0"6'-0"28'-4"GRAVEL FILL 31 2x312x 14" STL. COL. 31 2x31 2x 14" STL. COL.11'-712"12'-412"1'-8"5'-314"10 4 3 8 FOUNDATION DETAIL 1-A FD3 FOUNDATION DETAIL 1-A FD4 FOUNDATION DETAIL 1-A FD2FOUNDATION DETAIL 1-A FD1 FOUNDATION DETAIL 1-A FD5 36" CRAWL SPACE ACCESS 36" CRAWL SPACE ACCESS 113'-0"51'-4"10'-8"31 2x31 2x 14" STL. COL. 31 2x31 2x 14" STL. COL. 3'-034"12'-912" 3'-0 34 " 714"GRAVEL FILL 312"X312"X14" STL. COLUMN w/ 3 4"x12"x12" BASE PL. w/ (4) 34" HEADED ANCHOR ASTM A325 F1554 GRADE 36 SEE SCHEDULED FOR SIZE & REINFORCEMENT 3" CLEAR 3" CLEAR3" CLEAR1'-0"1. FOUNDATION DETAIL LEGEND INTERIOR COLUMN FOOTING DETAIL TYPICAL DETAIL INTERIOR COLUMN FOOTING SEE SCHEDULED FOR SIZE & REINFORCEMENT 3" CLEAR3" CLEAR 4 PLY BLOCKING ANCHORED TO FOUNDATION w/1 2" X 8" ANCHOR BOLTS DRILLED & EPOXY 48" o.c.Date: 06-15-2021Plan number #210113Designed For:Jim & Chris ThomasH. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignFTG. SIZE N0. REINFORCEMENT INTERIOR COLUMN FOOTING SCHEDULE 1'-0" VERIFY MECHANICAL ACCESSES THROUGH FOUNDATION WALL w/ CONTRACTOR & MECHANICAL CONTRACTOR ALL MASONRY LEDGES TO BE 4" UNLESS OTHERWISE NOTED A 54"X54"X12" (5)#4's E.W. B 48"X48"X12" (4)#4's E.W. C 42"X42"X12" (4)#4's E.W. D 36"X36"X12" (3)#4's E.W. E 30"X30"X12" (3)#4's E.W. TYPICAL FOOTING REINFORCINGTIMES STEP TWO STEP(SEE PLAN)POURED CONCRETE WALL BASED ON A SAFE ALLOWABLE BEARING PRESSURE OF 2000 psf ( TO BE FIELD VERIFIED ) 2. FOOTING STEP MASONRY PRECAST WALL DETAIL 3. FOUNDATION WALL MATERIAL CONCRETE BLOCK WALLS POURED CONCRETE WALLS 4. GENERAL NOTES SCALE: 1/4"=1'-0"FOUNDATION DETAILS "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 1Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER 06/29/22