HomeMy WebLinkAboutConstruction Plan First Floor A101.pdfUPUPGENERAL CONSTRUCTION NOTESCONSTRUCTION PLAN KEYNOTESCONSTRUCTION PLAN LEGENDA. CONTRACTOR TO PROVIDE BUILDING WINDOW BLINDS, UNLESS NOTED OTHERWISE. RE-USE EXISTING WHEN APPLICABLE.B. PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES WHEN APPLICABLE. PATCH AND REPAIR AS REQUIRED.C. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. REFER TO ELECTRICAL LOCATION PLANS FOR MORE INFORMATION.D. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), INTERNATIONAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.E. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.F. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR COMPLETION OF THIS PROJECT.G. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNERS F.F.E.H. DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.I. ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS, PREMIUM GRADE.J. CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES, BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.K. COORDINATE WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF EXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR CLEAN AIRFLOW, WRITTEN NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR, OWNER, AND FACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS DURING ALL PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.NOT IN CONTRACT, IF APPLICABLEEXISTING WALL OR ITEM TO REMAINNEW CONSTRUCTION ITEM###EQUIPMENT PLAN KEYNOTESX105110DWREF104115114116101RECEPTION100CONFERENCE101PRIVATEOFFICE102PRIVATEOFFICE103PRIVATEOFFICE104HUDDLE105PRIVATEOFFICE106PRIVATEOFFICE107BREAK/COFFEE108SERVER109PRIVATEOFFICE110PRIVATEOFFICE111PRIVATEOFFICE112OPENOFFICE113ZOOMROOM114ZOOMROOM115STORAGE116112A1012136136EQEQ6' - 11"A1013A1014139A60167DWREF119155BREAK/COFFEE1081195' - 0" CLEAR MIN6' - 11 1/2" ±7' - 9 3/8" ±1' - 6"130153150152A6015100123100115114116CONFERENCE101ZOOMROOM114ZOOMROOM115STORAGE11610113813613' - 4 1/2"EQEQ101131132131A10312A1033A103S4.11S4.40S4.11S4.10S4.11S4.40S4.40S4.11S4.11S4.11154132132A6011A601A6013425"2' - 6"5' - 0"2' - 0"1' - 0"4' - 3"3' - 8"6' - 0"2' - 6"5"2' - 0"1' - 0"4' - 11"2' - 0"1"4' - 10"1"11"11"1"4' - 2"1"ALL IDEAS, DESIGNS AND PLANS (ORIGINAL WORKS OF AUTHORSHIP FIXED IN A TANGIBLE MEDIUM OF EXPRESSION) INDICATED OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF MITSCH DESIGN. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING.PRELIMINARY PRICING SETSTATE SUBMITTAL SETDRAWN BY:CHECKED BY:MD PROJECT #:CONSTRUCTION PLAN -FIRST FLOORA10121065111 CONGRESSIONAL BLVD, SUITE 100CARMEL, IN 46032SHEPHERD INSURANCESHEPHERD INSURANCE05.20.2204.15.22-CRESSTATE SUBMITTAL SETSCALE:3/32" = 1'-0"1CONSTRUCTION PLAN100 24"D PLASTIC LAMINATE COUNTERTOP (PL-2) IN THIS LOCATION INSTALLED WITH HIDDEN BRACKETS, MOUNT AT 30" AFF.101 REUSE EXISTING GLAZING SYSTEM WITH WOOD MULLIONS IN THIS LOCATION104 PROVIDE NEW FLOOR CORE POWER AND DATA FOR MODULAR WORKSTATIONS WHERE NOT POSITIONED ADJACENT TO A WALL105 TENANT PROVIDED PRINTER/COPIER110 NEW CARPET AND VINYL BASE IN THIS LOCATION119 18"D PLASTIC LAMIANTE COUNTER WITH SS TRASH RING AND TRASH CABINET BELOW123 PROVIDE WATERLINE FOR COFFEE MAKER IN THIS LOCATION130 FILL IN WALL; WALL TYPE TO MATCH ADJACENT WALLS.131 ALIGN FINISH FACE OF WALL WITH OUTSIDE FACE OF STAIR STRINGER ABOVE132 EXTEND WALL TO BOTTOM OF STAIR STRUCTURE ABOVE AND SEAL136 PROVIDE FIRE-RETARDANT IN-WALL BLOCKING FOR PLASMA SCREEN.138 EXTEND WALLS IN THIS ROOM TO DECK OR STRUCTURE ABOVE; INSULATE WALLS AND PROVIDE SOUND ATTENUATION BLANKETS EXTENDED 2'-0"EACH SIDE OF PARTITION ABOVE CEILING.139 PROVIDE A GORDON MULLION MATE PARTITION GAP CLOSURE (OR SIMILAR) WHERE NEW WALL MEETS EXISTING WINDOW MULLION.SCALE:1/4" = 1'-0"4FIRST FLOOR BREAK ROOMSCALE:1/4" = 1'-0"3FIRST FLOOR CONFERENCE AND ZOOM ROOMSSCALE:1/2" = 1'-0"2FIRST FLOOR RECEPTION DESK150 SINK TO BE KOHLER VAULT 33"X22" SMART DIVIDE UNDER-MOUNT SINK WITH SINGLE FAUCET HOLE, ITEM #K-3838-1.152 FAUCET TO BE KOHLER SIMPLICE PULL-DOWN FAUCET IN VIBRANT STAINLESS, ITEM #K-596-VS.153 FULL HEIGHT REFRIGERATOR TO BE GE 36" WIDE FRENCH DOOR IN STAILESS STEEL, ITEM #GNE27EYMFS.154 UNDERCOUNTER REFRIGERATOR TO BE SUMMIT 24" ADA COMPLIANT, STAINLESS STEEL FINISH, ITEM #AL55CSS.155 EXISTING APPLIANCE TO BE REUSED.REVISION SCHEDULE#DATEDESCRIPTION