HomeMy WebLinkAboutDemolition Plan First Floor D101.pdfD04D03D02D02D01D06D06D06D06D06D06D06D06D06D11D08RECEPTIONMAILPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICECONFERENCE ROOMPRIVATEOFFICEPRIVATEOFFICEPRIVATEOFFICESERVERBREAK ROOMSTORAGECONFERENCED14D14D14D18D213' - 8"3' - 4"3' - 5"3' - 4"3' - 11 3/4"D21D21D21D21D16D22D15D18D13D02D34D32D33DEMOLITION PLAN LEGENDGENERAL DEMOLITION NOTESDEMOLITION PLAN KEYNOTESA. ALL DEMOLITION OR REMOVED ITEMS SHALL BE CONSIDERED PROPERTY OF THE OWNER UNTIL SUCH A TIME VERIFICATION HAS BEEN MADE AS TO ITEMS NOT TO BE RETAINED BY THE OWNER PRIOR TO REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED COMPLETELY FROM THE SITE BY THE CONTRACTOR.B. MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW SPECIFIED FINISHES AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECIFICATIONS, AND DETAILS FOR SPECIFIC INFORMATION REGARDING APPLICATION OF NEW MATERIAL.C. SALVAGE ALL REMOVED DOORS AND FRAMES. SAVE FOR RELOCATION IN THE SPACE OR DISPOSE OF AS APPROVED BY OWNER. IF CONDITION OF RELOCATING DOORS WILL ALLOW, REPAIR AND/OR REFINISH AS SPECIFIED.D. DURING THE ENTIRE PERIOD OF DEMOLITION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.E. ANY ABANDONED OR DISCONTINUED ELECTRICAL OR COMMUNICATIONS BOXES AND/OR SWITCHES REMAINING IN WALLS ARE TO BE REMOVED IN THEIR ENTIRETY AS REQUIRED.F. GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WALLS ABOVE CEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RELOCATED, FILL IN OPENINGS TO BE FLUSH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL.G. THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND/OR DOORS AS INDICATED ON THIS DEMOLITION PLAN, OR AS DEEMED NECESSARY BY THE ARCHITECT, OWNER, OR INSPECTOR. THEY SHALL BE MAINTAINED AND REPAIRED IMMEDIATELY IF ANY DAMAGE OCCURS. THESE DOOR ARE TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS.H. ALL WALLCOVERING TO BE REMOVED; PATCH/REPAIR WALLS TO LIKE NEW CONDITION, READY TO RECIEVE NEW FINISH AS SPECIFIED.I. REFER TO FINISH PLANS AND NEW CONSTRUCTION LAYOUT FOR DETAILS ON FINISH MATERIAL AND EQUIPMENT/FIXTURE DEMOLITION/REMOVAL.J. COORDINATE SALVAGE AND REUSE OF ALL WALL-MOUNTED EQUIPMENT WITH TENANT.K. WRAP ALL ABOVE CEILING PIPING WITH FIRE PROTECTION AS REQUIRED PER LOCAL AND STATE REQUIREMENTS.NOT IN CONTRACT, IF APPLICABLEEXISTING WALL OR ITEM TO BE REMOVED OR DEMOLISHEDEXISTING WALL OR ITEM TO REMAIN###ALL IDEAS, DESIGNS AND PLANS (ORIGINAL WORKS OF AUTHORSHIP FIXED IN A TANGIBLE MEDIUM OF EXPRESSION) INDICATED OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF MITSCH DESIGN. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING.PRELIMINARY PRICING SETSTATE SUBMITTAL SETDRAWN BY:CHECKED BY:MD PROJECT #:DEMOLITION PLAN -FIRST FLOORD10121065111 CONGRESSIONAL BLVD, SUITE 100CARMEL, IN 46032SHEPHERD INSURANCESHEPHERD INSURANCE05.20.2204.15.22-CRESSTATE SUBMITTAL SETSCALE:3/32" = 1'-0"1DEMOLITION PLAND01 REMOVE POWERPOLES IN THIS LOCATIOND02 REMOVE CASEWORK IN THIS LOCATIOND03 REMOVE WINDOWS AND GLAZING MULLIONS, REUSE IN NEW DESIGN AT FIRST FLOOR CONFERENCE ROOM AS APPLICABLED04 DEMOLISH RECEPTION DESK IN THIS LOCATIOND06 REMOVE FLOORING AND VINYL BASE IN THIS LOCATION; PREP FOR NEW MATERIALD08 REMOVE CARPETING ON STAIRS; PREP FOR NEW MATERIALD11 CONTRACTOR TO REMOVE ALL EXISTING WORKSTATIONS IN OPEN AREAD13 DISHWASHER TO REMAIN IN THIS LOCATION AND INCORPORATED INTO NEW CABINETSD14 LIGHT FIXTURE IN THIS LOCATION TO BE REMOVED AND RELOCATEDD15 REMOVE ALL WINDOW BLINDS AT INTERIOR SUITE WINDOWS LOOKING OUT TO BUILDING CORED16 REMOVE WALL-MOUNTED EQUIPMENT AND POWER/DATA IN THIS LOCATION DURING CONSTRUCTIOND18 REMOVE APPLIANCE, COORDINATE WITH TENANT ON DISPOSAL OR REUSED21 REMOVE ALL WOOD FLOOR BASE AT ENTRY AND COFFEE AREA AT FIRST FLOORD22 REMOVE WALL-MOUNTED LOGO, COORDINATE WITH TENANT ON REUSED32 REMOVE EXISTING DECAL LETTERING FROM GLAZINGD33 REROUTE EXISTING SPRINKLER LINE AS REQUIRED FOR NEW LAYOUT/ROOMS BELOW STAIR. ADD HEADS AS REQUIREDD34 RELOCATE WATER DISPENSER PER TENANT'S DIRECTIONREVISION SCHEDULE#DATEDESCRIPTION