Loading...
HomeMy WebLinkAboutLife Safety Plan Second Floor G002.pdfUPMAXIMUM PATH OF TRAVEL = 291'-0"EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS6X8EXST WS8X8EXST WS8X8EXST WS6X8EXST WS6X8EXPANSIONEXPANSIONRECESSED CABINET OR WALL MOUNTED FIRE EXTINGUISHER DENOTES DIRECTION OF EGRESS TO EXIT/EXIT DISCHARGENOTE: COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH LOCAL FIRE CHIEF AS REQUIRED.NOTE: REFER TO REFLECTED CEILING PLAN AND OR ELECTRICAL ENGINEER DRAWINGS FOR ALL EMERGENCY AND EXIT LIGHT LOCATIONS.DESCRIPTIONPROPOSED USE OF FACILITYBUILDING CONSTRUCTION TYPEOCCUPANCY CLASSIFICATION(S)OCCUPANCY separations REQUIREDTOTAL OCCUPANTS PER LOAD FACTORSMAX ALLOWABLE/ACTUAL BLDG AREA(S)MAX ALLOWABLE/ACTUAL BLDG HEIGHTAUTOMATIC SPRINKLER SYSTEMPORTABLE FIRE EXTINGUISHERSFIRE ALARM SYSTEMSMOKE DETECTIONCOMMON PATH OF EGRESS TRAVELEXIT ACCESS TRAVEL DISTANCECORRIDOR FIRE-RESISTANCE RATINGENCLOSED EXIT ACCESS STAIRDEAD END CORRIDOR MAXMIN CORRIDOR WIDTH MIN/MAX DOOR WIDTHDOORSEXITS REQUIRED/PROVIDEDWATERCLOSETS REQUIRED/PROVIDEDLAVATORIES REQUIRED/PROVIDEDDRINKING FOUNTAINS REQUIRED/PROVIDED SERVICE SINK REQUIRED/PROVIDEDVARIANCE(S)RENOVATIONOFFICEIIA (EXISTING) (TABLE 601)B (SECT 302)EXISTING (TABLE 508.4)28,697 (SUITE) SF / 100 SF/PERSON = 287 OCCUPANTS (TABLE 1004.1.2)150,000 / 38,897 (EXISTING)TOTAL SQUARE FEET (TABLE 503)5 / 5 (EXISTING) STORIES (TABLE 503)EXISTING (SECT 903)MAX TRAVEL DISTANCE TO EXTINGUISHER = 75' (TABLE 906.3)EXISTING (SECT 907)EXISTING (SECT 907)100 FEET (TABLE 1014.3)300 FEET (TABLE 1016.2)EXISTING (TABLE 1018.1)EXISTING (SECT 1009)50 FEET (SECT 1018.4)44 INCHES (TABLE 1018.2)32/48 INCHES (SECT 1008.1.1)EGRESS DOOR MUST SWING TOWARDS EGRESS WHEN SERVING 50 OR MORE OCCUPANTS. MANUALLY OPERATED SLIDING DOORS ONLY PERMITTED FROM OCC LOAD SPACES OF 10 OR LESS. (SECT 1008.1.2) PANIC/FIRE EXIT HARDWARE IS ONLY REQUIRED WHEN SERVING 50 OR MORE OCCUPANTS. (SECT 1008.1.10)7 EXISTING (SECT 1015)M - 9 (EXISTING) W - 9 (EXISTING) (TABLE 2902.1)M - 6 (EXISTING) W - 6 (EXISTING) (TABLE 2902.1)6 (EXISTING) (TABLE 2902.1)EXISTING (TABLE 2902.1)NOT REQUIREDLIFE SAFETY LEGENDCODE ANALYSISAPPLICABLE BUILDING CODESCODEDESCRIPTIONCOMPRISED OFGENERAL ADMINISTRATION RULES(ENTIRE DOCUMENT)GENERAL ADMINISTRATION RULES(GAR) (UPDATED 08.01.2014) (AMENDED 12.01.2014)BUILDING CODE(INDIANA AMENDMENTS)FIRE CODE(INDIANA AMENDMENTS)PLUMBING CODE(INDIANA AMENDMENTS)ELECTRICAL CODE(INDIANA AMENDMENTS)MECHANICAL CODE(INDIANA AMENDMENTS)HANDICAP ACCESSIBILITY CODE(INDIANA AMENDMENTS)ENERGY CODE(INDIANA AMENDMENTS)2010 INDIANA ENERGY CONSERVATION CODE (IECC) -EFFECTIVE 05.07.20102014 INDIANA BUILDING CODECHAPTER 11 - ACCESSIBILITY 2014 INDIANA MECHANICALCODE (IMC) - EFFECTIVE 12.01.20142009 INDIANA ELECTRICALCODE (IEC) - EFFECTIVE 08.26.20092012 INDIANA PLUMBING CODE (IPC) - EFFECTIVE 12.24.20122014 INDIANA FIRE CODE (IFC) -EFFECTIVE 12.01.20142014 INDIANA BUILDING CODE(IBC) - EFFECTIVE 12.01.2014* ASHRAE 90.1 2007* 675 IAC 19.3* 675 IAC 13-2.6-12 CHAPTER 11* A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, 2009 EDITION* 2012 INTERNATIONALMECHANICAL CODE * 675 IAC 18-1.6* 2008 NFPA 70 * 675 IAC 17-1.8* 2006 INTERNATIONAL PLUMBING CODE* 675 IAC 16-1.4* 2012 INTERNATIONAL FIRE CODE* 675 IAC 22-2.5* 2012 INTERNATIONALBUILDING CODE * 675 IAC 13-2.6* 675 IAC 12FEELEVATOR SAFETY CODE 2011 INDIANA ELEVATOR SAFETY CODE (IESC) (UPDATED 09.28.2011)* 675 IAC 21, * ANSI/ASME A17.1,2007,* ANSI/ASME A90.1,2003, * ANSI/A10.4,2004, * ASME/ A18.1,2005, *A17.3,2005, *ASME QEI-1,2007DENOTES 1-HR RATED WALLDENOTES 2-HR RATED WALLNOT IN CONTRACT, IF APPLICABLEALL IDEAS, DESIGNS AND PLANS (ORIGINAL WORKS OF AUTHORSHIP FIXED IN A TANGIBLE MEDIUM OF EXPRESSION) INDICATED OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF MITSCH DESIGN. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING.PRELIMINARY PRICING SETSTATE SUBMITTAL SETDRAWN BY:CHECKED BY:MD PROJECT #:LIFE SAFETY PLAN -SECOND FLOORG00221065111 CONGRESSIONAL BLVD, SUITE 100CARMEL, IN 46032SHEPHERD INSURANCESHEPHERD INSURANCE05.20.2204.15.22-CRESSTATE SUBMITTAL SETSCALE:3/32" = 1'-0"1SECOND FLOOR LIFE SAFETY PLANREVISION SCHEDULE#DATEDESCRIPTION