HomeMy WebLinkAboutReflected Ceiling Plan Second Floor A202.pdfREFLECTED CEILING PLAN KEYNOTESREFLECTED CEILING PLAN LEGENDGENERAL REFLECTED CEILING NOTESA. PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDING CODES.B. CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND ALL APPLICABLE BUILDING CODES.C. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND RETURN AIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELY BALANCED AND EFFICIENT HEATING AND COOLING SYSTEM.D. HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED.E. MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING THERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE.F. PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS OTHERWISE NOTED.G. REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.H. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK.I. EXISTING CEILING HEIGHT THROUGHOUT THE SPACE IS TO REMAIN, UNLESS NOTED OTHERWISE.J. EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING.K. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.L. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN TILE, UNLESS NOTED OTHERWISE.M. COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTED OTHERWISE.N. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE.O. THERMOSTATS SHALL BE LOCATED ADJACENT TO LIGHT SWITCH AND WITHIN REACH RANGES OUTLINED IN ANSI A117.1-2009 SECTION 308 AND 309. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT.P. SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. Q. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE.R. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION.S. SPRINKLER SYSTEM IS EXISTING TO REMAIN. RELOCATED SPRINKLER HEADS AS NEEDED FOR NEW WALL LOCATIONS.NOT IN CONTRACT, IF APPLICABLEDENOTES NEW 2'x2' ACOUSTICAL CEILING GRID/TILEREUSE EXISTING CEILING, PROVIDE NEW TO MATCH AS REQUIREDDENOTES RELOCATED 2'x4' RECESSED ELECTRICAL FIXTUREDENOTES NEW RECESSED CAN LIGHT (BUILDING STANDARD OR EQUAL)NOTE: PANEL LOADS ARE EXISTING TO REMAIN.NOTE: ALL LIGHTING IS EXISTING TO REMAIN, UNLESS NOTED OTHERWISENOTE: MECHANICAL LOADS ARE EXISTING TO REMAIN. RELOCATE EXISTING DIFFUSERS FOR NEW OFFICE LOCATIONS.###RDENOTES EXISTING PENDANT, RELOCATEDRDENOTES NEW PENDANT: TECH LIGHTING - AKOVA X-LARGE PENDANT IN AGED BRASS/BRIGHT BRASSDENOTES NEW LINEAR PENDANT: ALDER & ORE - KAITLYN LINEAR SUSPENSION FIXTURE IN SATIN BRASSRDENOTES EXISTING WALL SCONCE, RELOCATEDDENOTES EXISTING 2'x2' ACOUSTICAL CEILING GRID/TILEREPAIR AND REPLACE EXISTING CEILING AFTER DEMOLITION AND ALIGN WITH ADJACENT CEILING GRID TO MAKE GRID CONTINUOUS. PROVIDE NEW TO MATCH AS REQUIREDDENOTES EXISTING 2'x2' ACOUSTICAL CEILING GRID/TILEEXPANSIONEXPANSIONEQEQ3' - 0"EQEQ5' - 0"RR211217210205206214214214210210RR2072111' - 0"1' - 0"1' - 0"6' - 6"2002082132132122162012103' - 7 1/2"9' - 9"8' - 5 1/4"209212209214R RRR217214214ALL IDEAS, DESIGNS AND PLANS (ORIGINAL WORKS OF AUTHORSHIP FIXED IN A TANGIBLE MEDIUM OF EXPRESSION) INDICATED OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF MITSCH DESIGN. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING.PRELIMINARY PRICING SETSTATE SUBMITTAL SETDRAWN BY:CHECKED BY:MD PROJECT #:REFLECTED CEILINGPLAN -SECOND FLOORA20221065111 CONGRESSIONAL BLVD, SUITE 100CARMEL, IN 46032SHEPHERD INSURANCESHEPHERD INSURANCE05.20.2204.15.22-CRESSTATE SUBMITTAL SETSCALE:3/32" = 1'-0"102_SECOND FLOOR REFLECTED CEILING PLAN200 NEW PENDANT LIGHTS IN THIS LOCATION; STAGGER HEIGHTS AT 7'-6" AND 8'-6" AFF.201 PROVIDE NEW EXIT LIGHTS IN THIS ROOM, CONFIRM STYLE WITH TENANT.205 SALVAGED PENDANT TO BE RELOCATED TO THIS LOCATION - MOUNT AT 6'-0" AFF. COORDINATE WITH TENANT ON FINAL LOCATION PRIOR TO ELECTRICALROUGH-IN AND MOUNTING.206 SALVAGED PENDANT TO BE RELOCATED TO THIS LOCATION - MOUNT AT 6'-6" AFF. COORDINATE WITH TENANT ON FINAL LOCATION PRIOR TO ELECTRICALROUGH-IN AND MOUNTING.207 SALVAGED SCONCES TO BE RELOCATED TO THIS LOCATION - REFER TO ELEVATION FOR LOCATIONS AND MOUNTING HEIGHTS. COORDINATE WITH TENANT ONFINAL LOCATION PRIOR TO ELECTRICAL ROUGH-IN AND MOUNTING.208 PROVIDE HEADER IN THIS LOCATION; HEADER TO BE 2" BELOW EXISTING CEILING GRID/TILE.209 NEW PENDANT LIGHT IN THIS LOCATION - MOUNT AT 6'-6".210 ADJUST EXISTING LIGHTING IN THIS LOCATION TO ACCOMMODATE NEW LAYOUT, IF REQUIRED.211 UTILIZE EXISTING CIRCUITRY AND SWITCHING IN AREA FOR RELOCATED FIXTURE.212 PROVIDE SWITCH FOR NEW PENDANT WITH EXISTING SWITCH FOR GENERAL LIGHTING IN AREA.213 PROVIDE NEW SWITCH FOR GENERAL LIGHTING AND PENDANT(S) IN THIS LOCATION.214 PROVIDE NEW SWITCH FOR GENERAL LIGHTING IN THIS LOCATION.216 PAINT CENTER CEILING BULKHEAD P-2.217 ADD NEW CAN LIGHTS TO EXISTING CIRCUITRY AND SWITCH FOR GENERAL LIGHTING IN THIS ROOM.REVISION SCHEDULE#DATEDESCRIPTION