HomeMy WebLinkAboutWalls and Door Types and Schedule A000.pdfDOOR TYPESHARDWARE TYPES#1 PASSAGE LATCH (DBL DR)1 LEVER HANDLE PASSAGE LATCH SET2 DOOR STOP6 SILENCERS 1 CONST LATCHING BOLT(MATCH TO EXISTING)#2 OFFICE LOCKSET1 LEVER HANDLE OFFICE LOCKSET1 DOOR STOP3 SILENCERS(MATCH TO EXISTING)#4 PRIVACY LOCKSET1 LEVER HANDLE PRIVACY LOCKSET1 CLOSER1 DOOR STOP3 SILENCERS(MATCH TO EXISTING)7' - 0"3' - 0"3' - 0"7' - 0"10"TYPE #1SOLID WOOD(BIRCH).TYPE #2SOLID WOOD WITH LITE KIT (BIRCH)NOTES & SPECIFICATIONSFRAME TYPESDOOR SCHEDULEXXXGENERAL NOTES:1. DOOR, FRAME, HARDWARE, AND WINDOW MANUFACTURERS SHALL SUBMIT SHOP DRAWINGS FOR REVIEW.2. DO NOT SCALE DRAWINGS.3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO STARTING WORK AND ADVISE THE OWNER'S REPRESENTATIVE IN WRITING OF ANY DISCREPANCIES.4. REFER TO G051 FOR ARCHITECTURAL ABBREVIATIONS AS NEEDED.FRAME AND DOOR TYPE:1. ALL DOORS NOTED TO MATCH EXISTING STYLES AND CONTRACTOR TO FIELD VERIFY THE EXISTING DOOR FRAME AND MATCH.2. ALL OTHER DOORS AND FRAMES TO AND BE PAINTED AS INDICATED IN THE FINISH SCHEDULE.HARDWARE TYPE:1. HARDWARE SUPPLIER SHALL PROVIDE ALL HARDWARE ITEMS REQUIRED TO MAKE A COMPLETE AND FINISHED JOB INCLUDING HINGES, STOPS, LOCK SETS, LATCH SETS, COORDINATORS, PANIC DEVICES, HOLD OPENS, SMOKE GASKETS, WEATHERSTRIPPING, AND SILENCERS WHETHER SPECIFICALLY INDICATED ON HARDWARE LEGEND OR NOT.2. ALL HARDWARE (TYPE AND FINISH) TO MATCH TO EXISTING SUITE STANDARDS.3. PROVIDE PANIC AND EXISTING HARDWARE AS REQUIRED BY CODE.4. PROVIDE JUNCTION BOXES IF/AS REQUIRED FOR KEY FOB READERS AT ALL ENTRANCES. COORDINATE WITH TENANT SECURITY VENDOR.GLAZING:1. ALL DOOR GLAZING TO BE 1/4" INTERIOR, CLEAR, TEMPERED, PROVIDE FILM AT ALL DOOR GLAZING.2. ALL EXISTING SHADES/BLINDS AT EXTERIOR WINDOWS TO REMAIN UNLESS NOTED OTHERWISE. REPLACE DAMAGED SHADES/BLINDS IF/AS REQUIRED. CLEAN ALL BLINDS AS REQUIRED.3. FURNISH AND INSTALL NEW 1" METAL BLINDS ON ALL SIDELIGHTS IN EXPANSION AREA OF WORK, AND AT ALL NEW SIDELIGHTS.#3 STORAGE LOCKSET1 LEVER HANDLE STORAGE LOCKSET1 DOOR STOP3 SILENCERS(MATCH TO EXISTING)TTYPE #1SOLID WOODFRAME W/ SIDELIGHT(MATCH TO EXISTING)TYPE #2SOLID WOOD4"DR WIDTH4"DR HGTDR WIDTHTYPE #3SOLID WOODFRAME W/ SIDELIGHT(MATCH TO EXISTING)DR HGT4"2' - 6"4"WIDTHDR4"6"1' - 6"5' - 8"TTDR HGT4"TYPE #4HOLLOW METALDOUBLE DOORDR HGTWIDTHDR PANELWIDTHDR PANEL3 5/8" METAL STUDS 20 GA, 16" O.C. WITH 5/8"GYPSUM BOARD BOTH SIDESBASE - SEE SCHEDULE FOR SPECIFICATIONSCONTINUOUS ACOUSTICAL SEALANTFLOOR LINEUNDERSIDE OF SLAB OR STRUCTURE ABOVESECTIONSECTIONPLANCEILING AS SCHEDULED, REFER TOREFLECTED CEILING PLANVARIES - SEE REFLECTED CEILING PLAN FOR HEIGHTINSULATION IN WALL CAVITY3 5/8" METAL STUDS 20 GA, 16" O.C. WITH 5/8"GYPSUM BOARD BOTH SIDESCEILING AS SCHEDULED, REFER TOREFLECTED CEILING PLANBASE - SEE SCHEDULE FOR SPECIFICATIONSCONTINUOUS ACOUSTICAL SEALANTFLOOR LINEUNDERSIDE OF SLAB OR STRUCTURE ABOVEVARIES - SEE REFLECTED CEILING PLAN FOR HEIGHTSECTIONSECTIONPLANINSULATION ABOVE CEILING 2'-0"ON EACH SIDE OF WALLINSULATION IN WALL CAVITY3 5/8" METAL STUDS 25 GA, 16" O.C. WITH 5/8"GYPSUM BOARD BOTH SIDESCEILING AS SCHEDULED, REFER TOREFLECTED CEILING PLANBASE - SEE SCHEDULE FOR SPECIFICATIONSCONTINUOUS ACOUSTICAL SEALANTFLOOR LINEINSULATION ABOVE CEILING 2'-0"ON EACH SIDE OF WALLUNDERSIDE OF SLAB OR STRUCTURE ABOVEVARIES - SEE REFLECTED CEILING PLAN FOR HEIGHTSECTIONSECTIONPLANBASE - SEE SCHEDULE FOR SPECIFICATIONSFLOOR LINE3 5/8" METAL STUDS 25 GA, 16" O.C. WITH 5/8"GYPSUM BOARD BOTH SIDESUNDERSIDE OF STAIRSECTION SECTION1/2"3 5/8" METAL STUDS 16 GA, 12" O.C.. HILTI FASTEN TO UNDERSIDE OF STAIR STRINGER WITH WASHER. WITH 5/8" GYP BOARD ONE SIDEALL IDEAS, DESIGNS AND PLANS (ORIGINAL WORKS OF AUTHORSHIP FIXED IN A TANGIBLE MEDIUM OF EXPRESSION) INDICATED OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF MITSCH DESIGN. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING.PRELIMINARY PRICING SETSTATE SUBMITTAL SETDRAWN BY:CHECKED BY:MD PROJECT #:WALL AND DOORTYPES & SCHEDULEA00021065111 CONGRESSIONAL BLVD, SUITE 100CARMEL, IN 46032SHEPHERD INSURANCESHEPHERD INSURANCE05.20.2204.15.22-CRESSTATE SUBMITTAL SETNO.SINGLE/ PAIRPANEL SIZE DOOR FRAME HARDWAREREMARKS /COMMENTSWIDE HGT THICK TYPE FINISH RTG TYPE FINISH RTG TYPE FINISH101PAIR 3' - 0" M.E. 1 3/4" 2 M.E. N.R. 4 M.E. N.R. 1 M.E. PROVIDE WINDOW FILM ATGLASS112 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 1 M.E. N.R. 2 M.E.114SGL 3' - 0" M.E. 1 3/4" 2 M.E. N.R. 2 M.E. N.R. 4 M.E. PROVIDE WINDOW FILM ATGLASS115SGL 3' - 0" M.E. 1 3/4" 2 M.E. N.R. 2 M.E. N.R. 4 M.E. PROVIDE WINDOW FILM ATGLASS116 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 2 M.E. N.R. 3 M.E.201PAIR 3' - 0" 8' - 6" 1 3/4" 2 M.E. N.R. 4 M.E. N.R. 1 M.E. PROVIDE WINDOW FILM ATGLASS224 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 3 M.E. N.R. 2 M.E.226 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 3 M.E. N.R. 2 M.E.228 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 3 M.E. N.R. 2 M.E.E226 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 2 M.E. N.R. 3 M.E.E227SGL 3' - 0" M.E. 1 3/4" 2 M.E. N.R. 2 M.E. N.R. 2 M.E. PROVIDE WINDOW FILM ATGLASSE232 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 1 M.E. N.R. 2 M.E.E233 SGL 3' - 0" M.E. 1 3/4" 1 M.E. N.R. 1 M.E. N.R. 2 M.E.SCALE:3/4" = 1'-0"S4.10 PARTITION TO DECK (UNINSULATED)SCALE:3/4" = 1'-0"S4.11 PARTITION TO DECK (INSULATED)SCALE:3/4" = 1'-0"S4.21 PARTITION TO CEILING (INSULATED)SCALE:3/4" = 1'-0"S4.40 PARTIAL HEIGHT WALL (TYP)*NOTE: REFER TO A103 FOR MORE INFORMATIONREVISION SCHEDULE#DATEDESCRIPTION