Loading...
HomeMy WebLinkAboutC006.0-CivilDetailsSEE SITE PLAN FOR SIGN TYPE NOTES: 1. SIGN PROVIDED BY TESLA. TAMPER PROOF HARDWARE PROVIDED BY CONTRACTOR. 2. POST & CAP SHALL BE PROVIDED BY CONTRACTOR. 3. IF PAINT FINISH IS DAMAGED DURING INSTALLATION, CONTRACTOR SHALL REPAINT AS REQUIRED. 4. NON-ILLUMINATED POLE MOUNT PARKING SIGN FACES AND RETURNS TO BE 0.090" ALUMINUM PANELS WITH #680-82 RED REFLECTIVE VINYL APPLIED (VERIFY REFLECTIVITY WITH OWNER). 5. LOGO TO BE #280-10 REFLECTIVE WHITE VINYL (VERIFY REFLECTIVITY WITH OWNER). 6. SEE TYPICAL TESLA PARKING SIGNAGE DETAIL FOR SIGNAGE VARIATION (IF APPLICABLE). 7. CONTRACTOR SHALL MOUNT SIGN POST IN 8" DIA., 3'-0" DEEP CONCRETE FOUNDATION OR CONCRETE BOLLARD. SEE PLAN. 8. SIGN POST SHALL BE POWDER COATED, COLOR - MEDIUM/DARK GREY 9. SIGN POST SHALL BE PLUGGED/CAPPED TO PREVENT WATER INTRUSION FROM TOP. 10. SIGN SHALL BE MOUNTED TO LIGHT POLE OR BOLLARD WHERE APPLICABLE. SEE PLAN. #8 TAMPER PRROOF SCREWS (TYP.) SIGN PLATE MECHANICALLY FASTENED TO 2"x2"x1/8" CONTRACTOR SUPPLIED HSS STEEL POST (8' LONG, 6' ABOVE GRADE) 1'-0"1'-6"6'-0" TO GRADE1N.T.S 4 N.T.S 7 N.T.S 5N.T.S 2N.T.S TESLA CHARGING CABINET ANCHOR BOLT PLAN TESLA CHARGING CABINET DIMENSIONS 9 N.T.S 6 N.T.S 3N.T.S 12 N.T.S 8"SEE PLAN CONCRETE PAD NOTES & CONCRETE SPECIFICATIONS: 1. FOUNDATION AREA SHALL BE EXCAVATED TO THE DEPTH AND DIMENSIONS SHOWN ON THE PLANS. OTHER UNSUITABLE MATERIAL SHALL BE REMOVED AND LEGALLY DISPOSED OF OFF-SITE. THE SUBGRADE SHALL BE ROLLED WITH A 1-TON, VIBRATORY, WALK-BEHIND ROLLER AT A SPEED OF LESS THAN 2 FPS, 6 PASSES MINIMUM, TO PROVIDE UNYIELDING SURFACE. 2. UNDERCUT SOFT OR "WEAVING" AREAS A MINIMUM OF 12 INCHES DEEP. BACKFILL UNDERCUT AREA WITH FILL MEETING THE SPECIFICATIONS OF STRUCTURAL FILL. 3. CONCRETE TO HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH (f'c)=2500 psi. 4. REINFORCING BAR TO BE ASTM A615 GRADE 60. 5. ALL REINFORCING TO HAVE MINIMUM CONCRETE COVER PER ACI SPECIFICATIONS. 6. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO ACI 318-14 AND APPLICABLE STATE BUILDING CODE. 7. PAD SHALL BE A MINIMUM OF 8" IN THICKNESS. THICKNESS OF PAD SHALL INCREASE AS THE PERIMETER SOIL SURFACE SLOPES TO MAINTAIN A MINIMUM OF 6" OF SOIL COVER TO THE BOTTOM OF THE PAD. 6" MIN, COMPACTED FROST-FREE GRAVEL FILL #4 BARS @12" O.C. EACH WAY CENTERED IN SLAB PROPOSED CONCRETE UNDISTURBED SOIL OR PREPARED SUBGRADE (95% STANDARD PROCTOR) GRADE2"3"MIN1/2" CHAMFER A 11.05.21REV.DATEDESCRIPTIONDrawing Name: O:\2021\2021095\98 - TRT 18712 - Carmel, IN\dwg\2021095.98- Carmel, IN N Illinois - CD90.dwgJune 10, 2022 12:28 PM - jarchDESIGNERINSTALL MANAGER C-3 JOB NO. ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 2021095.98 ABRWILL CARTER11545 N ILLINOIS ST.(TESLA STATION) - TRT18712CARMEL, IN 46032B 11.19.21 ISSUED FOR 90% REVIEWC 04.25.22ISSUED FOR 90% REVIEWISSUED FOR SIGN AND SEALXXX XXX XXX XXX 1 2 3 4 C B A GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 1 06.10.22 REVISIONS FOR CITY COMMENTSCIVIL DETAILSTYPICAL PARKING SIGN DETAIL SWITCHGEAR MOUNTING DETAIL CONCRETE PAD DETAIL CHARGING POST ELEVATION TESLA CHARGING CABINET ENCLOSURE: INGRESS PROTECTION IP66 WEIGHT: 1110 kg, 2448 lbs. COMPLIANCE: UL 2202 NOTES: 1. CABINET SHOULD BE LIFTED USING ROOF MOUNTED EYE HOOKS. A FORKLIFT OR PALLET JACK CAN ALSO BE USED TO MOVE CABINET IF DONE PROPERLY. 2. VERIFY CABINET PART# AND ASSOCIATED DIMENSIONS PRIOR TO CONSTRUCTION52.76"89.5"54.72" 49.21"88.32"41.98" 37.8" 35.83"33.86"SIDE TOP VENT FAN DEADBACK DEADBACKNOTE: 1. TESLA PROVIDED TEMPLATE PLATE TO BE USED TO LAYOUT CHARGING CABINET ANCHORING BOLT LOCATIONS AND CONDUIT STUB UP LOCATIONS. 2. BOLT HOLES FOR REFERENCE ONLY. 3. USE DOTTIE DUCT SEAL COMPOUND PC 6130 (CAT NO LHD1) TO SEAL ENDS OF CONDUIT (TYP. ALL CONDUITS FOR CHARGING CABINETS AND CHARGE POSTS) 4. USE BELL FITTINGS ON ALL AC AND DC CONDUIT STUBS. OPENING FOR SHARED DC BUSS CONNECTIONS BETWEEN CABINETS 52.76"33.86"AC AC COMM BUS BUS BUS BUS BUS BUS BUS BUS BUS BUS BUS BUS POST A POST BPOST C POST D FRONT BACK 6.7"21.19"4.56" 14" 15.59" 24.84" 9.26"9.25" 10.83"0.65"21.84"24.4"33.86"INCOMING FROM SOURCE: (2) AC CONDUITS. STUB UP SHALL BE 6" OFF GROUND AND END IN FEMALE NPT THREADED COUPLING (SEE NOTE 4). SEE FEEDER SCHEDULE FOR CONDUIT SIZE/QUANTITY CAST-IN-PLACE FOUNDATION: (4) 5/8" DIA. HILTI KWIK BOLT TZ STAINLESS STEEL ANCHORS, 3-1/8" MIN. EMBEDMENT WITH 8" MIN. BOLT SPACING AND EDGE DISTANCE PROVIDED AND INSTALLED BY CONTRACTOR OUTGOING TO POSTS: STUB UP SHALL BE 6" OFF GROUND AND END IN FEMALE NPT THREADED COUPLING (SEE NOTE 4). SEE FEEDER SCHEDULE FOR CONDUIT SIZE/QUANTITY. DETAIL NOT USED 10 N.T.S CHARGING POST CONTINUOUS CURB AND WALL FOUNDATION DETAIL CHARGING POST CONTINUOUS CURB AND WALL REINFORCEMENT DETAIL NOTES: 1. REFER TO SWITCHGEAR MANUFACTURER DRAWINGS FOR MOUNTING HOLE LOCATIONS, SWITCHGEAR BAY DIMENSIONS, AND BASE CHANNEL DIMENSIONS. 2. MINIMUM EDGE DISTANCE FOR PROPOSED ANCHORAGE SHALL BE 8". TYPICAL BOTTOM VIEW LAYOUT. SEE NOTE 1 DETAIL 1 BOTTOM VIEW SEE NOTE 1 SEE NOTE 19/16" DIA. MOUNTING HOLES (TYP.) FRONT OF SWITCHGEAR PROPOSED SWITCHGEAR ASSEMBLY CABINET HEAVY DUTY NUT BELLEVILLE WASHER PROPOSED 1/2" HILTI KWIK BOLT TZ STAINLESS STEEL ANCHOR 3-1/4" EFFECTIVE EMBEDMENT MIN. (ESR#1917) PROPOSED CONCRETE SLAB HAND HOLE GROUND LUG BOLT COVER 3/4" CHAMFER CONTRACTOR SHALL COORDINATE WITH POLE MANUFACTURER FOR ANCHOR BOLTS #6 CU. BARE GROUND CONDUCTOR BRANCH CIRCUIT WIRING IN CONDUIT AT 24" (MINIMUM) BELOW GRADE 1" SPARE CONDUIT STUBBED INTO POLE BASE & CAPPED 12" FROM BASE 3/4"x10'-0" CU. CLAD GROUND ROD (6) #6 REBAR (VERTICAL) TIE-WIRED TO #4 REBAR TIES AT 12" ON CENTER, U.N.O. REINFORCED CONCRETE, 2500 PSI COMPRESSIVE STRENGTH ADDITIONAL #4 REBAR TIES @ 3" ON CENTER 13 2'-0" DIA. 3" CLEAR TYP. MEASURED FROM EDGE OF TIES 8'-0"GRADE 3" CLEARTYP.3'-0"11 9 8 5 4 3 3"3"2"1 2 3 4 5 6 7 8 10 11 12 13 14 9 2 1 7 14 6 12 10 EXISTING LIGHT POLE TO BE RELOCATED RUB CONCRETE TO REMOVE SONOTUBE FORM LINES AND FILL ALL HOLES FOR SMOOTH FINISH. WEATHERSEAL ALL EXPOSED CONCRETE. LIGHT POLE FOUNDATION DETAIL NOTES: 1. BOLLARD MUST BE FROM TESLA AND INCLUDE WELDED ON FIXTURE ATTACHMENT PADS. 2. THE 4.33W, 315mA COMBINED TESLA LOGO AND TASK LIGHT LED ASSEMBLIES DRAWS POWER FROM THE PROPOSED SUPERCHARGER. 3. CONTRACTOR TO FIT REAR SKIN DURING INSTALLATION AND REMOVE REAR SKIN UNTIL TESLA INSPECTION IS COMPLETED. 20" 25-15/16" 6-3/32" CONDUIT SIZE 3 INCH CAR SIDE 30"1/2"2"66-13/32"31-7/8" 30" CURB (1) WHITE, 55mA TASK LIGHT LED ASSEMBLY (SEE NOTE 2) (2) RED, 130mA "TESLA" LOGO LED ASSEMBLIES (SEE NOTE 2) CAR SIDE PAVEMENT NOTE: 1. SEE CURB LENGTH ON SITE PLAN. 2. CHARGING POSTS AND PROPOSED FOUNDATION SHALL FOLLOW GRADE AS EVENLY AS POSSIBLE. 3. REINFORCING BAR TO BE ASTM A615 GRADE 60. 4. ALL REINFORCING TO HAVE MINIMUM CONCRETE COVER PER ACI SPECIFICATIONS. 5. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO ACI 318-14 AND APPLICABLE STATE BUILDING CODE. #4 TIE EVERY 1'-6" MAX. #4 REBAR AT TOP & BOTTOM (TYP.)CHAIR REBAR (TYP.) 3" MIN.3"MIN.TOP OF CURB 2'-4"6"EX. CURB EXPANSION JOINT DETAIL 1'-2"#4 TIE EVERY 1'-6" MAX.#4 REBAR AT TOP & BOTTOM (TYP.)2'-4"3"3"PLAN R=1 /4 "TYP. ANCHORING NOTES: ANCHORS: (4) 5/8” DIAMETER HILTI KWIK BOLT TZ STAINLESS STEEL ANCHORS. 3-1/8” EFFECTIVE EMBEDMENT MIN. 6” EDGE DISTANCE MIN. (ESR#1917) FASTENERS: (2) TOTAL 5/8” NUTS AND (2) TOTAL 5/8” WASHERS PER ANCHOR NUT AND WASHER MATERIAL TYPE TO MATCH ANCHOR MATERIAL (2) 5/8” NUT AND WASHER ABOVE BOLLARD FLANGE, (1) BELOW. CONTRACTOR TO PROTECT EXISTING CURB AND PAVEMENT DURING INSTALLATION OF CONCRETE FOUNDATION. REPAIR OR REPLACE AS REQUIRED. CAR SIDE PAVEMENT PROPOSED 20" CONCRETE CURB 2'-4" FOR REBAR SPECIFICATIONS, SEE DETAIL THIS SHEET1'-2"6"COMPACTED AGGREGATE FOR REBAR SPECIFICATIONS, SEE DETAIL THIS SHEET2'-4"5"7"#4 VERT. DOWEL @ 12" O.C. (CENTERED IN CURB). 90° HOOK INTO PAD #4 REBAR (CONT.)3"3"2'-8"8" 8"2'-8"8"8"8"3" MIN. OPTIONAL CONSTRUCTION JOINT. ROUGHEN SURFACE #4 REBAR (CONT.)206/10/22 07/06/22