HomeMy WebLinkAboutE003.0-ElecDetails#1. " " DENOTES FEEDER REFERENCE. REFER TO SHEET E-2 FOR FEEDER/CIRCUIT SCHEDULE. 2. CONTRACTOR SHALL REFER TO CIVIL SHEETS FOR EXISTING LANDSCAPING TO REMAIN AND PROPOSED LANDSCAPING. 3. CONTRACTOR SHALL HAND DIG AROUND ALL EXISTING UTILITIES. 4. CONDUIT ELBOWS SHALL BE SIZED PER NEC. CONTRACTOR SHALL VERIFY MANUFACTURER ALLOWABLE FILL AND MINIMUM CONDUCTOR BENDING RADIUS. SEE FEEDER SCHEDULE FOR CONDUIT & CONDUCTOR SPECIFICATIONS. 5. ALL CONDUITS ACCESSIBLE TO THE PUBLIC OR WHICH CAN BE DAMAGED SHALL BE RIGID GALVANIZED STEEL. 6. PROPERTY LINE AND RIGHT-OF-WAY BOUNDARIES ARE SHOWN FOR REFERENCE ONLY. REFER TO SURVEY BY OTHERS FOR EXACT LOCATION. 7. UTILITY EQUIPMENT INSTALLATIONS AND PREP WORK SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER TO ENSURE ACCURACY OF INSTALLATION. 8. ALL PROPOSED CONDUITS MUST MEET MINIMUM DEPTH REQUIREMENTS AS OUTLINED IN TRENCH DETAILS, AS WELL AS MAINTAIN A MINIMUM OF 18" CLEAR OF ALL EXISTING OBSTRUCTIONS INCLUDING (BUT NOT LIMITED TO) STORM PIPES, SANITARY PIPES, WATER LINES AND OTHER UNDERGROUND UTILITIES. 9. PROPERTY LINE AND RIGHT-OF-WAY BOUNDARIES ARE SHOWN FOR REFERENCE ONLY. REFER TO SURVEY BY OTHERS FOR EXACT LOCATION. 10. FOR TRAFFIC CONTROL PROCEDURES (IF APPLICABLE), SEE TRAFFIC CONTROL NOTES ON SHEET GN-1.ELECTRICALEQUIPMENT PLANGENERAL SHEET NOTES 0' 10'5' SCALE: 1"=10'FULL SIZE A 11.05.21REV.DATEDESCRIPTIONDrawing Name: O:\2021\2021095\98 - TRT 18712 - Carmel, IN\dwg\2021095.98- Carmel, IN N Illinois - CD90.dwgJune 10, 2022 12:29 PM - jarchDESIGNERINSTALL MANAGER E-1 JOB NO. ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 2021095.98 ABRWILL CARTER11545 N ILLINOIS ST.(TESLA STATION) - TRT18712CARMEL, IN 46032B 11.19.21 ISSUED FOR 90% REVIEWC 04.25.22ISSUED FOR 90% REVIEWISSUED FOR SIGN AND SEALXXX XXX XXX XXX 1 2 3 4 C B A GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 1 06.10.22 REVISIONS FOR CITY COMMENTS PROVIDE PRIMARY SIDE BORING PROVIDE & INSTALL PRIMARY SIDE CONDUITS W/ PULLWIRE PROVIDE & INSTALL PRIMARY SIDE CONDUCTORS PROVIDE & INSTALL UTILITY POLE (RISER BY CONTRACTOR) PROVIDE & INSTALL UTILITY TRANSFORMER PAD PROVIDE UTILITY TRANSFORMER INSTALL UTILITY TRANSFORMER INSTALL CONNECTIONS AT UTILITY TRANSFORMER (PRIMARY) INSTALL CONNECTIONS AT UTILITY TRANSFORMER (SECONDARY) PROVIDE METER INSTALL METER PROVIDE SECONDARY SIDE TRENCHING PROVIDE & INSTALL SECONDARY SIDE CONDUITS W/ PULLWIRE PROVIDE ROAD CUTS / ROAD BORES PROVIDE & INSTALL PAVEMENT REPLACEMENT ELECTRICAL SCOPE OF WORK RESPONSIBILITIES PROVIDE & INSTALL PRIMARY SIDE OVERHEAD CONDUCTORS NOTE: SCOPE SHOWN ABOVE WAS PROVIDED BY AES. FIELD VERIFY PRIOR TO CONSTRUCTION. PROVIDE & INSTALL SECONDARY SIDE CONDUCTORS SCOPE BY UTILITY BY CONTRACTOR x x x x x x x x x x x x x x x x x PROVIDE CTs INSTALL CTs (INSIDE H-FRAME) x x AES ATTN: RODNEY JOHNSON (330) 261-5047 RODNEY.JOHNSON@AES.COM POWER COMPANY CONTACTS (8) PROPOSED TESLA CHARGING POSTS (TYP.)C-3 10 2 x x PROVIDE METER BASE AND CT CABINET INSTALL METER BASE 15'-0" EXISTING ELECTRICAL EASEMENT 15'-0"ELEC. EASEMENTAPPROXIMATE LOCATION ORDINANCE D-2116-12 SEE SURVEY 20'-0" BERM ENCROACHMENT EASEMENT 20'-0" LANDSCAPE BUFFER PROPOSED ELECTRICAL LINE EASEMENT 1A 1B 1C 1D 2A 2B 2C 2D 1 (2) PROPOSED TESLA CHARGING CABINETS (TYP.)C-3 2 (4) PROPOSED TESLA CHARGING POST CONDUITS (1 PER POST) 3 E-3 3 (4) PROPOSED TESLA CHARGING POST CONDUITS (1 PER POST) 3 E-3 3 PROPOSED UTILITY TRANSFORMER WITH TAPS, 480V/277V, 3Ø, 4W SECONDARY ON CONCRETE PAD. REFER TO SUPPLEMENTAL UTILITY PAD DETAIL PRIOR TO INSTALLATION PROPOSED UNDERGROUND PRIMARY CONDUITS & CONDUCTORS BY UTILITY. PROPOSED CT CABINET, PT & METER MOUNTED ON H-FRAME E-3 5 PROPOSED UNDERGROUND SERVICE LATERAL CONDUITS FROM PROPOSED TRANSFORMER TO PROPOSED CT CABINET PER POWER COMPANY REQUIREMENTS 1 E-3 1 PROPOSED SWITCHGEAR ASSEMBLY W/ INTEGRATED MASTER CONTROLLER - DEAD BACK PROPOSED UNDERGROUND SERVICE LATERAL CONDUITS FROM PROPOSED CT CABINET TO PROPOSED SWITCHGEAR PER POWER COMPANY REQUIREMENTS 1 E-3 1 (4) PROPOSED CONDUITS FROM SWITCHGEAR TO CHARGING CABINETS (2 PER CHARGING CABINET) ALONG WITH (2) CONDUITS FOR COMMUNICATION CABLES FROM MASTER CONTROLLER (1 PER CABINET) E-3 2 25 PROPOSED CONDUITS ROUTED FROM EACH CABINET TO CENTER CABINET FOR SHARED DC BUS CONNECTION 6 E-3 2 PROPOSED LOCATION FOR RELOCATED LIGHT ON CONCRETE FOUNDATION (TYPICAL OF 1) C-3 9 CONTRACTOR SHALL RELOCATE UNDERGROUND LIGHTING CIRCUIT TO PROPOSED LOCATION. PROVIDE HANDHOLE AND SPLICE & EXTEND CONDUIT & WIRING TO NEW LOCATION. MATCH SIZE AND MATERIAL. 06/10/22 07/06/22