Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
C1.1 STAKING PLAN
XXXXXXXXXXR/W R/W R/W ESMT ESMT ESMT ESMT ESMT ESMT ES MT ESMT ESMT ESMT ESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMTESMT3.1' 8.2' ESMT ESMT ESMT ESM T ESMTESMTESMTESMTPL PL PL PLPLPLPLPLPL PLPL 50' Ex. R/WWetland HC HC HC HC HC VANPR. PIPE CULVERT INV. 882.00 R/W R/W 47' Preservation Easement Construction Limits Construction Limits Construction Limits 10 SPACES @ 9'=90'-0" 10 SPACES @ 9'=90'-0"18'-0"25'-0"18'-0"25'-0"9 SPACES @ 9'=82'-0"14 SPACES @ 9'=126'-0"25'-0"4 SPACES@ 9'=36'-0"5 SPACES @ 9'=45'-0"25'-0"9'5'9'9'9'9'5'8'18'-0" 18'-0" 1 2 3 4 25'-0"R20'-0"R2 0 ' - 0 " EXISTING BUILDING 5 5 5 5 55 5 PROPOSED BUILDING ADDITION 5' 7'-6" 4'-6" 5'-0" 10'-0" R/W Dedication 5 5 5 5 STAKING LEGEND EXISTING PROPOSED HC X 1. DIMENSIONS AND COORDINATES ARE GIVEN TO FACE OF CURB AND FACE OF BUILDING UNLESS OTHERWISE NOTED. 2. CURB AND SIDEWALK RADII SHALL BE 5'-0" UNLESS OTHERWISE NOTED. 3. PROVIDE STRIPING AND SYMBOLS AS SHOWN PER INDOT ITEM 808. TYPICAL LINE WIDTH SHALL BE 4 INCHES, COLOR WHITE. 4. STANDARD PARKING STALL DIMENSIONS ARE 9'-0" IN WIDTH BY 20'-0" IN LENGTH UNLESS OTHERWISE NOTED. 5. SAWCUT FULL DEPTH SIDEWALK AND PAVEMENT WHERE NEW WORK ABUTS EXISTING CONSTRUCTION. TAKE CARE TO PROVIDE NEAT STRAIGHT LINES. PROVIDE PAVEMENT SEALANT PER INDOT ITEM 401 AT JOINT BETWEEN EXISTING AND NEW ASPHALT. REMOVE CONCRETE TO NEAREST JOINT. PROVIDE 1 2" PREFORMED EXPANSION JOINT FILLER BETWEEN NEW AND EXISTING CONSTRUCTION. 6. ANY PROPERTY PINS DAMAGED AS PART OF CONSTRUCTION SHALL BE RESET BY AN INDIANA REGISTERED SURVEYOR. 7. PROVIDE 4 HANDICAP ACCESSIBLE PARKING SIGNS AND 1 VAN ACCESSIBLE PARKING SIGNS AS SHOWN ON DETAIL C/C1.2. FINAL LOCATION OF SIGNS TO BE DETERMINED BY ARCHITECT. 8. MAINTAIN PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT BUILDINGS AT ALL TIMES DURING CONSTRUCTION. 9. REFER TO ARCHITECTURAL DRAWINGS FOR ALL SITE SIGNAGE NOT SHOWN ON THIS SHEET. 10. BUILDING COORDINATES PROVIDED FOR BUILDING LOCATION ONLY. REFER TO ARCHITECTURAL PLANS FOR BUILDING LAYOUT. 11. PROVIDE CONTROL JOINTS PER DETAIL D/C1.2. PROVIDE ISOLATION JOINTS WHERE NEW CONCRETE ABUTS EXISTING STRUCTURES PER DETAIL E/C1.2 AND PER SPECIFICATIONS. 1. PROPOSED EMERGENCY GENERATOR. REFER TO ELECTRICAL SHEETS. 2. PROPOSED UTILITY SERVICE TRANSFORMER. REFER TO ELECTRICAL SHEETS. 3. PROPOSED MEDGAS ENCLOSURE. REFER TO ARCHITECTURAL SHEETS. 4. BICYCLE RACK PER DETAIL F/C1.2 (TYP. 2). 5. SAW-CUT EXISTING PAVEMENT WITH NEAT, STRAIGHT LINES. MATCH EXISTING PAVEMENT GRADE AT THIS POINT. 0 GRAPHIC SCALE SCALE IN FEET 30 60 90 GENERAL NOTES: CODED NOTES: STRAIGHT CURB PER STD. DWG. 10-16 PAVEMENT WALK SCORE CONSTRUCTION LIMITS PAINTED WHEELCHAIR SYMBOL HANDICAPPED PARKING SIGN PER DETAIL C/C1.2 LIGHT DUTY ASPHALT PER DETAIL B/C1.2 CONCRETE SIDEWALK PER STD. DWG. 10-18 OR 10-19 REFER TO TOPOGRAPHIC SURVEY REVISION: PROJECT NUMBER: 20297 Sheet Name: © 2021 M+A Architects 04 MARCH 2022 DATE: SHEET NUMBER:RENOVATION AND ADDITIONMEDVET CARMEL - ANIMALHOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032STATUS: PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: 2021-0012 STAKING PLAN C1.1AWM AWM JDB BUILDING/WALL PARKING CALCULATION USE SQUARE FOOTAGE MINIMUM VETERINARY HOSPITAL 30,305 SF 1:300 SF = 101 REQUIRED PARKING 101 EXISTING PARKING TO REMAIN 41 PROPOSED PARKING 56 TOTAL PARKING 97 REQUIRED ADA PARKING (VAN/TOTAL)1/5 PROPOSED ADA PARKING (VAN/TOTAL)1/5 HEAVY DUTY ASPHALT PER DETAIL A/C1.2 FENCE. REFER TO ARCHITECTURAL DETAILS GENERAL ZONING & PROJECT INFORMATION ADDRESS:650 MAYFLOWER PARK DR PARCEL NO.:17-13-07-00-09-002.000 EXISTING ZONING CLASSIFICATION/DISTRICT:I-1 TOTAL SITE AREA:4.52 AC FRONT BUILDING SETBACK:15' SIDE BUILDING SETBACK:5' REAR BUILDING SETBACK:15' PROPOSED BUILDING HEIGHT:35'-0" BUILDING USE:VETERINARY HOSPITAL EXISTING BUILDING AREA (SF):15,205 PROPOSED BUILDING ADDITION AREA (SF):15,100 TOTAL BUILDING AREA (SF):30,305 MAXIMUM LOT COVERAGE:90% EXISTING LOT COVERAGE 20.3% PROPOSED LOT COVERAGE:35.4% TOTAL PROJECT DISTURBANCE:1.30 AC IMPERVIOUS AREA ADDED:1.02 AC LIGHT FIXTURE. REFER TO ELECTRICAL SHEETS. MULTI-USE PATH PER STD. DWG. 10-20 HEAVY DUTY CONCRETE PER DETAIL G/C1.2 PT. OF THE SOUTHWEST 1 4, SECTION 7, TWP. 17 NORTH, RG. 3 EAST, 2ND P.M., CLAY TWP., HAMILTON COUNTY, INDIANA SITE LEGAL DESCRIPTION: 07/11/22